ML13088A164
| ML13088A164 | |
| Person / Time | |
|---|---|
| Site: | Vallecitos File:GEH Hitachi icon.png |
| Issue date: | 03/25/2013 |
| From: | Mcfadden A GE-Hitachi Nuclear Energy Americas |
| To: | Document Control Desk, NRC/FSME |
| References | |
| AEM 13-04 | |
| Download: ML13088A164 (5) | |
Text
0 HITACHI GE Hitachi Nuclear Energy Anthony McFadden Site Manager GEH Vallecitos Nuclear Center 6705 Vallecitos Rd Sunol, CA 94586 Ser: AEM 13-04
-444 anthony.mcfadden @ ge.com March 25, 2013 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001
Subject:
Annual Report for EVESR, 2012
Reference:
License DR-10, Docket 50-183
Enclosure:
Annual Report No. 45 Enclosed is the Annual Report No. 45 for the deactivated ESADA-Vallecitos Experimental Superheat Reactor (EVESR), located at Vallecitos Nuclear Center near Sunol, California.
If there are any questions, or additional information required, please contact me at the number above.
Sincerely, Aen Manager, Vallecitos Nuclear Center Cc: John Buckley, NRC (by e-mail)
Robert Evans, NRC Region IV (by e-mail)
/j
0 HITACHI GE Hitachi Nuclear Energy Vallecitos Nuclear Center Sunol, California ESADA-VALLECITOS EXPERIMENTAL SUPERHEAT REACTOR (DEACTIVATED)
ANNUAL REPORT NO. 45 FOR THE YEAR 2012 LICENSE DR-10 DOCKET 50-1.83 MARCH 2013
1 -1 EVESR Annual Report No. 45 ESADA-Vallecitos Experimental Superheat Reactor (Deactivated)
ANNUAL REPORT NO. 45 GE Hitachi Nuclear Energy (GEH) has maintained the ESADA Vallecitos Experimental Superheat Reactor (EVESR) in a deactivated status under the authority of Amendment No. 7 to License DR-10, Docket 50-183, issued December 1, 2008. In this annual report, a summary of the status of the facility for the period of January 1, 2012 to December 31, 2012 is presented, as required by Amendment 7, Appendix A, Technical Specifications, section C. 1.
1.0
SUMMARY
Component removal activities began in 2008 above the 549 foot level. Tech Spec changes issued in Amendment 7 December 1, 2008 authorize the removal of systems beside the reactor vessel and bio-shield below the 549 level. Component removal concluded (current scope) in 2010. Entry into the containment building was made for routine radiation surveys and a general examination of conditions throughout the building. In accordance with written procedures, the Facility Manager controls access to the containment building.
Radiation and contamination levels remain at acceptable levels.
2.0 STATUS OF FACILITY The facility continues to be in deactivated status. The plugs to the reactor vessel and head storage shield, the wooden cover over the fuel storage pool remain in place.
3.0 RADIATION AND CONTAMINATION Complete radiation and contamination surveys of the facility indicate that levels remain low. Results of the surveys are presented in Table 1. The radiation/contamination levels listed are representative but not necessarily maximum values.
4.0 ACTIVITIES Routine inspections were conducted during this report period.
The equipment disposal concluded during 2010.
Page 1 of 3
EVESR Annual Report No. 45 5.0 ORGANIZATION The organizational structure changed during 2012. The Site Manager remains A. E.
McFadden. The VBWR Facility Manager remains M. R. Schrag. The Manager, Regulatory Compliance and EHS is now E. F. Saito.
6.0 CONCLUSION
GE Hitachi Nuclear Energy concludes that the deactivated ESADA-Vallecitos Experimental Superheat Reactor is being maintained in a safe shutdown condition.
The inspections, access control, and administratively controlled activities ensure maximum protection for the public health and safety. The procedures will be continued to maintain this high level of protection.
GE Hitachi Nuclear Energy Vallecitos Operations Al.agrc FVa d den n Manager Vallecitos Nuclear Center Page 2 of 3
EVESR Annual Report No. 45 Table 1 Radiation and Contamination Level Data ESADA-Vallecitos Experimental Superheat Reactor (Deactivated)
Contamination Levels Surface Smears Airborne Radiation Beta-Gamma Beta-Gamma'.
Levels (dpm/ft2)
(pCi/cc x 10-10)
(mR/h Beta-(decayed)
Gamma)
Report Year 2011 2012 2011 2012 2011 2012 Reactor Enclosure Top of spent fuel pool
<1
<1 100 100 (main floor) 549-ft level (main floor)
<1
<1 100 100 0.007 0.02 534-ft level 16**
14**
500 100 519-ft level
<1
<1 500 500 0.16 0.13 503-ft level (maximum
<1
<1 750 pipe reading) 487-ft level (basement)
<1
<1 1,000 2,000 0.007 0.30 Note:
Radiation levels, surface smears, and air samples may vary from survey to survey as they are taken in general areas rather than at specific locations.
- - taken at the EC valve area Survey Dates: