ML13044A001

From kanterella
Jump to navigation Jump to search
Reed College - Acknowledgement of Response to Notice of Violation, NRC Inspection Report No. 50-288-12-201
ML13044A001
Person / Time
Site: Reed College
Issue date: 02/13/2013
From: Gregory Bowman
Research and Test Reactors Branch B
To: Krahenbuhl M
Reed College
Bassett, Craig
References
IR-12-201
Download: ML13044A001 (3)


See also: IR 05000288/2012201

Text

February 13, 2013

Dr. Melinda Krahenbuhl, Director

Reed Reactor Facility

Reed College

3203 S.E. Woodstock Boulevard

Portland, OR 97202-8199

SUBJECT:

REED COLLEGE - ACKNOWLEDGEMENT OF RESPONSE TO NOTICE OF

VIOLATION (NRC INSPECTION REPORT NO. 50-288/2012-201)

Dear Dr. Krahenbuhl:

Thank you for your response of January 30, 2013, to our Notice of Violation issued on

January 2, 2013, concerning activities conducted at your TRIGA Mark-I Reed Research Reactor

facility. We have evaluated your response and found that it meets the requirements of Title 10 of

the Code of Federal Regulations Section 2.201. We will examine the implementation of your

correctives action during a future inspection.

We appreciate your cooperation in this matter.

Sincerely,

/RA/

Gregory T. Bowman, Chief

Research and Test Reactors Oversight Branch

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Docket No. 50-288

License No. R-112

cc:

See next page

Reed College

Docket No. 50-288

cc:

Mayor of City of Portland

1220 Southwest 5th Avenue

Portland, OR 97204

Reed College

ATTN: Dr. Patrick McDougal

Dean of the Faculty

3203 S.E. Woodstock Boulevard

Portland, OR 97202-8199

Reed College

ATTN: Mr. John Kroger

President

3203 S.E. Woodstock Boulevard

Portland, OR 97202-8199

Oregon Department of Energy

ATTN: David Stewart-Smith, Director

Division of Radiation Control

625 Marion Street, N.E.

Salem, OR 97310

Test, Research, and Training

Reactor Newsletter

University of Florida

202 Nuclear Sciences Center

Gainesville, FL 32611

February 13, 2013

Dr. Melinda Krahenbuhl, Director

Reed Reactor Facility

Reed College

3203 S.E. Woodstock Boulevard

Portland, OR 97202-8199

SUBJECT:

REED COLLEGE - ACKNOWLEDGEMENT OF RESPONSE TO NOTICE OF

VIOLATION (NRC INSPECTION REPORT NO. 50-288/2012-201)

Dear Dr. Krahenbuhl:

Thank you for your response of January 30, 2013, to our Notice of Violation issued on

January 2, 2013, concerning activities conducted at your TRIGA Mark-I Reed Research Reactor

facility. We have evaluated your response and found that it meets the requirements of Title 10 of

the Code of Federal Regulations Section 2.201. We will examine the implementation of your

correctives action during a future inspection.

We appreciate your cooperation in this matter.

Sincerely,

/RA/

Gregory T. Bowman, Chief

Research and Test Reactors Oversight Branch

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Docket No. 50-288

License No. R-112

cc:

See next page

DISTRIBUTION:

PUBLIC

RTR R/F

RidsNrrDpr

RidsNrrDprPrta

RidsNrrDprPrtb

CBassett, NRR

GLappert, NRR

Gwertz, NRR

XYin, NRR

Accession No. ML13044A001

  • concurrence via e-mail

NRR-106

OFFICE

NRR/DPR/PROB/RI

NRR/DPR/PROB/LA

NRR/DPR/PROB/BC

NAME

CBassett (*)

GLappert (*)

GBowman

DATE

2/12/2013

2/13/2013

2/13/2013

OFFICAL RECORD COPY