ML13018A207

From kanterella
Jump to navigation Jump to search
Response to Notice of Violation NRC Inspection Report 05000285/2012005
ML13018A207
Person / Time
Site: Fort Calhoun 
(DPR-040)
Issue date: 01/18/2013
From: Replogle G
NRC/RGN-IV/DRS/PSB-2
To: Cortopassi L
Omaha Public Power District
References
EA-12-174 IR-12-005
Download: ML13018A207 (2)


See also: IR 05000285/2012005

Text

January 18, 2013

EA-12-174

Lou Cortopassi, Vice President

and Chief Nuclear Officer

Omaha Public Power District

Fort Calhoun Station FC-2-4

P.O. Box 550

Fort Calhoun, NE 68023-0550

Subject:

RESPONSE TO NOTICE OF VIOLATION AND NRC INSPECTION

REPORT 05000285/2012005

Dear Mr. Cortopassi:

Thank you for your letter, dated December 13, 2012, in which you responded to our

November 13, 2012, Integrated Inspection Report 05000285/2012005 and Notice of Violation.

The violation involved the failure to update your Updated Safety Analysis Report concerning

your steam generator storage facility. We will review the implementation of your corrective

actions during a future inspection to determine that full compliance has been achieved and will

be maintained.

Sincerely,

/RA/

George Replogle, Acting Chief

Plant Support Branch 2

Division of Reactor Safety

Docket: 50-285

License: DPR-40

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION IV

1600 EAST LAMAR BLVD

ARLINGTON, TEXAS 76011-4511

ML13018A207

DAMS

No

X Yes

X SUNSI Review Complete

Reviewer Initials: GDR

Category

X Publicly Available

X Non-sensitive

Category

Non-publicly Available

Sensitive

KEYWORD:

Sensitive:

SRI:DRS/PSB2

C:PSB2

LCarson

GReplogle

GDR for

/RA/

01/18/2013

01/18/2013