ML13007A124

From kanterella
Jump to navigation Jump to search
Kld TR-481, Rev. 2, Perry Nuclear Power Plant Development of Evacuation Time Estimates, Part 5 of 6
ML13007A124
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 10/31/2012
From:
KLD Engineering, PC
To:
Office of Nuclear Reactor Regulation
References
L-12-441 KLD TR-481, Rev 2
Download: ML13007A124 (71)


Text

APPENDIX K Evacuation Roadway Network

K. EVACUATION ROADWAY NETWORK As discussed in Section 1.3, a link-node analysis network was constructed to model the roadway network within the study area. Figure K-1 provides an overview of the link-node analysis network. The figure has been divided up into 35 more detailed figures (Figure K-2 through Figure K-36) which show each of the links and nodes in the network.

The analysis network was calibrated using the observations made during the field survey conducted in November 2010. Table K-1 lists the characteristics of each roadway section modeled in the ETE analysis. Each link is identified by its road name and the upstream and downstream node numbers. The geographic location of each link can be observed by referencing the map number provided in Table K-1.

The term, "No. of Lanes" in Table K-1 identifies the number of lanes that extend throughout the length of the link.

Many links have additional lanes on the immediate approach to an intersection (turn pockets); these have been recorded and entered into the input stream for the DYNEV II System.

As discussed in Section 1.3, lane width and shoulder width were not physically measured during the road survey. Rather, estimates of these measures were based on visual observations and recorded images.

Table K-2 identifies each node in the network that is controlled and the type of control (stop sign, yield sign, pre-timed signal, actuated signal, traffic control point) at that node.

Uncontrolled nodes are not included in Table K-2.

Perry Nuclear Power Plant Evacuation Time Estimate K-1 KLD Engineering, P.C.

Rev. 2

Figure K-1. Perry Link-Node Analysis Network Perry Nuclear Power Plant Evacuation Time Estimate K-2 KLD Engineering, P.C.

Rev. 2

Figure K-2. Link-Node Analysis Network - Grid 1 Perry Nuclear Power Plant Evacuation Time Estimate K-3 KLD Engineering, P.C.

Rev. 2

Figure K-3. Link-Node Analysis Network - Grid 2 Perry Nuclear Power Plant Evacuation Time Estimate K-4 KLD Engineering, P.C.

Rev. 2

Lake t

Ene I

.. j."

(;r Ad 2

=

G Rd A

AN SOAh~a N Bend Rd

'T372 fthianD

'373 (jr-id 3 L0.e NC London Rd I

Subarn 4 544 52 EEIR d

Perry Nuclear Power Plant PNPP Subar.a Link-Node Analysis Network Figures 2, 5*.1*, 15 Mile ItIngs Grid 3 I.[.

ndex Grid Watr 0i..i2 L

I Figure K-4. Link-Node Analysis Network - Grid 3 Perry Nuclear Power Plant Evacuation Time Estimate K-5 KLD Engineering, P.C.

Rev. 2

Figure K-S. Link-Node Analysis Network - Grid 4 Perry Nuclear Power Plant Evacuation Time Estimate K-6 KLD Engineering, P.C.

Rev. 2

Figure K-6. Link-Node Analysis Network - Grid 5 Perry Nuclear Power Plant Evacuation Time Estimate K-7 KLD Engineering, P.C.

Rev. 2

Grid I i

Inado fOlOa Dr LakeI 1'57 V

45

!1 302 ah Al Subara I ~~ary*#r~'Smbere4 77 (irik/

la

~ 17j 521.

1 S

t

~

O 4~V 251 I

l~abh

/

24 7Toddh Orir i

a1 Ane 470 A

142 j 251 2455-a 1ý 14 h

a 74 C,4

U 237I~i%2~

rs I

ýW__

Angey Or.

?42 2)"

A

(;ri~4~

l~i 77 99 2. A Mei (41i4/6%

_I.n j

A.

9 6 a

/

ý.rSbae5 I

Legend Kf,.nap Perry Nuclear Power Plant PNPP Subarea Link-Node Analysis Network Figures Node Shadow Region U-,

Unk 2 5, 10, 15 Mile Rings Grid 6 In--edex Grid Wae r 0eK'r-1 Figure K-7. Link-Node Analysis Network - Grid 6 Perry Nuclear Power Plant K-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

Figure K-8. Link-Node Analysis Network - Grid 7 K-9 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-9 KLD Engineering, P.C.

Rev. 2

i Figure K-9. Link-Node Analysis Network - Grid 8 K-b KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-10 KLD Engineering, P.C.

Rev. 2

Figure K-10. Link-Node Analysis Network - Grid 9 Perry Nuclear Power Plant Evacuation Time Estimate K-11 KLD Engineering, P.C.

Rev. 2

Figure K-11. Link-Node Analysis Network - Grid 10 K-12 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-12 KLD Engineering, P.C.

Rev. 2

Figure K-12. Link-Node Analysis Network - Grid 11 Perry Nuclear Power Plant Evacuation Time Estimate K-13 KLD Engineering, P.C.

Rev. 2

Figure K-13. Link-Node Analysis Network - Grid 12 Perry Nuclear Power Plant Evacuation Time Estimate K-14 KLD Engineering, P.C.

Rev. 2

Figure K-14. Link-Node Analysis Network - Grid 13 K-iS KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-15 KLD Engineering, P.C.

Rev. 2

Figure K-15. Link-Node Analysis Network - Grid 14 Perry Nuclear Power Plant Evacuation Time Estimate K-16 KLD Engineering, P.C.

Rev. 2

Figure K-16. Link-Node Analysis Network - Grid 15 Perry Nuclear Power Plant Evacuation Time Estimate K-17 KLD Engineering, P.C.

Rev. 2

Figure K-17. Link-Node Analysis Network - Grid 16 Perry Nuclear Power Plant Evacuation Time Estimate K-18 KLD Engineering, P.C.

K-18 KLD Engineering, P.C.

Rev. 2

Figure K-18. Link-Node Analysis Network - Grid 17 Perry Nuclear Power Plant Evacuation Time Estimate K-19 KLD Engineering, P.C.

Rev. 2

Figure K-19. Link-Node Analysis Network - Grid 18 K-20 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-20 KLD Engineering, P.C.

Rev. 2

Figure K-20. Link-Node Analysis Network - Grid 19 Perry Nuclear Power Plant Evacuation Time Estimate K-21 KLD Engineering, P.C.

Rev. 2

Figure K-21. Link-Node Analysis Network - Grid 20 K-22 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-22 KLD Engineering, P.C.

Rev. 2

Z :2 y'starowst Rd

~Grid 10 857

'1-faod ý,

~0 D

3 0

C3 ai o

Do 1.,ai I t,ýaod A $ 72

-lomII St ~

oaks sarUjae o,

rtR 0a 0

Do.on CI Lnmrark Dr

,~

U FmdlAy 3

3 3

yorkshire D,-

flr Ia (0

Grid 21 850 10,

'4 Perry Nuclear Power Plant Link-Node Analysis Network Figures Grid 21 0

0.2 1.,

Figure K-22. Link-Node Analysis Network - Grid 21 Perry Nuclear Power Plant Evacuation Time Estimate K-23 KLD Engineering, P.C.

Rev. 2

Figure K-23. Link-Node Analysis Network - Grid 22 K-24 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-24 KLD Engineering, P.C.

Rev. 2

I

~

carpent0~2~~$

e or

~v5.r 600 41"anZ 4

D 0

fC t, 602 1Go G

r I

d't,622 I1 d

2S 011 Heoy' G

602' 6

Johr2yk

-d--

go 613 0

N

~6_m oi F

Brrchforri; a

626

(,24 23n.YD 27

/02 Merwra D,

A 1

1 620 3

eato PI (I

3347 V

3

.1 A

870-463 z(irid 23ijri LegeId K.*

Perry Nuclear Power Plant PNPP I3 Subarea Unk-Node Analysis Network Figures 6

Node Shadow Region ILI

]

UfIt Lnk 2, 5, 10, 15 Mile Rings Gi2 jJIndex Grid Water 0

0.25 g05 Figure K-24. Link-Node Analysis Network - Grid 23 Perry Nuclear Power Plant K-25 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

0

'a0-540 I A

,0WV Page Dr LV i44 Subarea 6

& S Sunshine Dr Ciark Rd IT¸ Perry Nuclear Power Plant Link-Node Analysis Network Figures 0

05 1

MR.

a...r~et sat Figure K-25. Link-Node Analysis Network - Grid 24 Perry Nuclear Power Plant Evacuation Time Estimate K-26 KLD Engineering, P.C.

Rev. 2

353 909 2

2

'R~

V 270

\\

0 3,

2

-4 23 Huntoon Rd Leroy Center Rd So Rd%

Ild Subarea 6 Grid 25 I3 0

->17 S

CIO Af.,

4837

- 83 IOakhUWs A,,e 'Q Q2 Grid 32 ?eo"R' Perry Nuclear Power Plant Link-Node Analysis Network Figures Grid 25

0.

I5 MA..

Figure K-26. Link-Node Analysis Network - Grid 25 Perry Nuclear Power Plant Evacuation Time Estimate K-27 KLD Engineering, P.C.

Rev. 2

Moseley Rd 6

7

--70-"

Rhmyo"RdL Leroy Center Rd Subarea 5 3

Subarea 6 Cý)

SQ I

( r CD 0 "1~Ies

'55-0~

3 Ce 9

Leggett Rd Hart Rd Perry Nuclear Power Plant Link-Node Analysis Network Figures I Grid 26 0

0.5 1

Figure K-27. Link-Node Analysis Network - Grid 26 K-28 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-28 KLD Engineering, P.C.

Rev. 2

Figure K-28. Link-Node Analysis Network - Grid 27 Perry Nuclear Power Plant Evacuation Time Estimate K-29 KLD Engineering, P.C.

Rev. 2

Figure K-29. Link-Node Analysis Network - Grid 28 Perry Nuclear Power Plant Evacuation Time Estimate K-30 KLD Engineering, P.C.

Rev. 2

Figure K-30. Link-Node Analysis Network - Grid 29 Perry Nuclear Power Plant Evacuation Time Estimate K-31 KLD Engineering, P.C.

Rev. 2

i.* v-i

~C..

9&352

(,ri5l2 IKA-i<d9 2

Gria ri

j2 g

26 3450 Or 2A f

!24 mNd St I q

N: S0I~5 Kirtland Rd

\\16 IN "62 oe`

N~

r

2) 0 Wait Hill
Rdg, 0

ztd 8NR

-9a-

~

W~ttEagletd R

Eagl Mil t.l vi IiAlin

'~

Rd dogM,10R 0

idd Sk oýh r

0.dob

,Rd M0t~

"'Locust or

~Bar Rd Brolah,-0 1 TrI Dr -

Kirkwood Or Cranwocd 0r Rolle (tot c~lialgitbt Count r~~jnrbtodL U)k(ottt Countyt K

n' U

Legend Perry Nuclear Power Plant PNPP Subarea Unk-Node Analysis Network Figures 0

NodO Shadow Regoon SUnk 2,5, 10, 15 Mile Rings Gridr~jj Z30~

t~

A] IndetGrid Water Figure K-31. Link-Node Analysis Network - Grid 30 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-32 KLD Engineering, P.C.

Rev. 2

Figure K-32. Link-Node Analysis Network - Grid 31 Perry Nuclear Power Plant Evacuation Time Estimate K-33 KLD Engineering, P.C.

Rev. 2

4 61e P~khust Ave Sbrs6 Ik W

RadcIMOT KU' I

~~,Grid 25

~2W Cherýy I,0 215\\

92 821*

20i622,1,.

A~

_In IS.~d 04 VO, 713A 623\\

A.

SO,.e 15 6244 3216

~

-S Grijl 31&3S N

e33m STh Ave,.~-

It3

~

j~~D 31A Y

-0 15Jlifiles--

J 631 63 29

.222 c

-T2 S HaH,0 bde0St 975 I

i 1a1-do0 Rd

_fV 4?

2 220~

c S22W_4~4i rhmnog Rdc-JWoodtebo~k RdI~

Legend Perry Nuclear Power Plant SPNPp Subarea Unk-Node Analysis Network Figures Node Shad" Rat°"on I

-o-e Unrix 2,5,10,1 sMil o

Rinp

.j

.l' Grid 32 Inde Grd Watr

___0_

_jB..w~.

O Figure K-33. Link-Node Analysis Network - Grid 32 Perry Nuclear Power Plant K-34 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

Figure K-34. Link-Node Analysis Network - Grid 33 K-35 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-35 KLD Engineering, P.C.

Rev. 2

Figure K-35. Link-Node Analysis Network - Grid 34 K-36 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-36 KLD Engineering, P.C.

Rev. 2

Figure K-36. Link-Node Analysis Network - Grid 35 Perry Nuclear Power Plant Evacuation Time Estimate K-37 KLD Engineering, P.C.

Rev. 2

Table K-1. Evacuation Roadway Network Characteristics Steam Strea Lengt No of Lane Shole Flo Flo Map 1

1 342 SR 84 Collector 1939 1

12 4

1700 45 24 2

1 344 Chillicothe Rd Collector 1408 1

12 4

1700 45 24 3

2 31 SR 534 Local Roadway 554 1

12 4

1575 35 8

4 2

49 SR 534 Collector 2665 1

12 4

1575 35 8

5 2

447 US-20 Local Roadway 489 1

12 4

1575 35 8

6 2

450 US-20 Local Roadway 865 1

12 4

1575 35 8

7 3

364 1-90 Freeway 1234 2

12 8

2250 70 9

8 3

953 1-90 Freeway 4553 2

12 8

2250 70 9

9 4

5 1-90 Freeway 5654 2

12 8

2250 70 8

10 4

364 1-90 Freeway 4790 2

12 8

2250 70 9

11 5

4 1-90 Freeway 5652 2

12 8

2250 70 8

12 5

6 1-90 Freeway 14874 2

12 8

2250 70 8

13 6

5 1-90 Freeway 14874 2

12 8

2250 70 8

14 6

362 1-90 Freeway 1209 2

12 8

2250 70 8

15 7

8 1-90 Freeway 7416 2

12 4

2250 70 7

16 7

362 1-90 Freeway 7799 2

12 4

2250 70 7

17 8

7 1-90 Freeway 7412 2

12 4

2250 70 7

18 8

9 1-90 Freeway 7356 2

12 4

2250 70 7

19 9

8 1-90 Freeway 7356 2

12 4

2250 70 7

20 9

10 1-90 Freeway 4096 2

12 4

2250 70 7

21 10 9

1-90 Freeway 4095 2

12 4

2250 70 7

22 10 11 1-90 Freeway 1377 2

12 4

2250 70 17 1-90 off-ramp onto SR 23 10 361 528 Freeway Ramp 589 1

12 4

1714 40 17 Perry Nuclear Power Plant Evacuation Time Estimate K-38 KLD Engineering, P.C.

Rev. 2

Up Do-n uro Fre ri Link

  1. 5 Node Nod Rodwya e

RodayTp (ft.

Lae Wit Wit Rat Spee Nube 24 11 10 1-90 Freeway 1377 2

12 4

2250 70 17 1-90 off-ramp onto SR 25 11 95 528 Freeway Ramp 734 1

12 4

1714 40 17 26 11 360 1-90 Freeway 6145 2

12 4

2250 70 16 27 12 13 1-90 Freeway 2729 2

12 4

2250 70 16 28 12 360 1-90 Freeway 8192 2

12 4

2250 70 16 29 13 12 1-90 Freeway 2729 2

12 4

2250 70 16 30 13 14 1-90 Freeway 4362 2

12 4

2250 70 16 31 14 13 1-90 Freeway 4362 2

12 4

2250 70 16 32 14 15 1-90 Freeway 3013 2

12 4

2250 70 16 33 15 14 1-90 Freeway 3013 2

12 4

2250 70 16 34 15 16 1-90 Freeway 2787 2

12 4

2250 70 16 35 16 15 1-90 Freeway 2787 2

12 4

2250 70 16 36 16 17 1-90 Freeway 5395 2

12 4

2250 70 15 37 17 16 1-90 Freeway 5395 2

12 4

2250 70 15 38 17 18 1-90 Freeway 4137 2

12 4

2250 70 15 39 18 17 1-90 Freeway 4138 2

12 4

2250 70 15 40 18 359 1-90 Freeway 2353 2

12 4

2250 70 15 41 19 357 1-90 Freeway 7607 2

12 4

2250 70 15 42 19 359 1-90 Freeway 995 2

12 4

2250 70 15 43 20 21 1-90 Freeway 6557 2

12 4

2250 55 24 44 20 357 1-90 Freeway 8387 2

12 4

2250 70 25 45 21 20 1-90 Freeway 6557 2

12 4

2250 70 24 SR 44 on-ramp from 46 21 206 1-90 Freeway Ramp 978 1

12 4

1700 40 24 47I1 21 1966 1-90 Freeway 1763 2

12

[

4

[2250 70 24 Perry Nuclear Power Plant K-39 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

49 22 210 1-90 Freeway 12549 4

2250 24 50 23 22 1-90 Freeway 5999 2

12 4

2250 65 24 51 23 24 1-90 Freeway 4382 2

12 4

2250 65 24 52 24 23 1-90 Freeway 4382 2

12 4

2250 65 24 53 24 25 1-90 Freeway 2876 2

12 4

2250 65 23 54 25 24 1-90 Freeway 2876 2

12 4

2250 65 23 55 25 352 1-90 Freeway 2237 3

12 4

2250 65 23 56 26 27 1-90 Freeway 4293 3

12 4

2250 65 23 57 26 352 1-90 Freeway 2233 3

12 4

2250 65 23 58 27 26 1-90 Freeway 4293 3

12 4

2250 65 23 59 27 28 1-90 Freeway 644 3

12 4

2250 65 23 60 28 27 1-90 Freeway 644 3

12 4

2250 65 23 61 28 29 1-90 Freeway 2381 3

12 4

2250 65 30 1-90 off-ramp to SR 62 28 951 306 Freeway Ramp 1285 1

12 4

1700 30 22 63 29 28 1-90 Freeway 2381 3

12 4

2250 65 30 64 29 354 1-90 Freeway 875 3

12 4

2250 65 30 1-90 off-ramp to SR 65 29 952 306 Freeway Ramp 1288 1

12 4

1700 30 30 1-90 on-ramp from SR 66 30 6

534 Freeway Ramp 704 1

12 4

1700 40 8

67 30 35 SR 534 Collector 1635 1

12 4

1700 45 8

68 31 2

SR 534 Local Roadway 554 1

12 4

1575 35 8

69 31 392 SR 534 Collector 1605 1

12 4

1575 35 8

70 32 33 SR 534 Collector 611 1

12 4

1700 45 8

Perry Nuclear Power Plant K-40 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

Strea Strea Lengt No of Lane Shule Flo Flo Map.

0 71 32 80 SR 84 Collector 660 1

12 4

1700 40 8

72 32 154 SR 84 Collector 2690 1

12 4

1700 40 8

73 33 32 SR 534 Collector 611 1

12 4

1700 45 8

74 33 34 SR 534 Collector 2196 1

12 4

1700 45 8

75 34 33 SR 534 Collector 2196 1

12 4

1700 45 8

76 34 396 SR 534 Collector 3004 1

12 4

1700 45 8

77 35 30 SR 534 Collector 1628 1

12 4

1700 45 8

78 35 36 SR 534 Collector 1721 1

12 4

1700 60 8

79 36 35 SR 534 Collector 1714 1

12 4

1700 40 8

80 36 762 SR 534 Collector 237 1

12 4

1700 45 8

81 37 38 SR 534 Collector 1704 1

12 4

1700 60 18 82 38 39 SR 534 Collector 2362 1

12 4

1700 60 18 83 39 40 SR 534 Collector 1259 1

12 4

1700 60 18 84 40 41 SR 534 Collector 4103 1

12 4

1700 60 18 85 41 400 SR 534 Collector 4761 1

12 4

1700 60 18 86 42 43 SR 534 Collector 5949 1

12 4

1700 60 18 87 43 44 SR 534 Collector 7447 1

12 4

1700 60 28 88 44 45 SR 534 Collector 6028 1

12 4

1575 35 28 89 45 46 SR 534 Collector 6610 1

12 4

1700 60 28 90 45 402 CR 12 Collector 7809 1

12 4

1700 60 28 91 46 47 SR 534 Collector 1348 1

12 4

1700 60 28 92 47 48 SR 534 Collector 7435 1

12 4

1700 60 28 Exit Link 48 8048 SR 534 Collector 1701 1

12 4

1700 35 35 93 49 2

SR 534 Local Roadway 2666 1

12 4

1575 35 8

94 49 50 SR 534 Collector 580 1

12 4

1575 35 8

Perry Nuclear Power Plant K-41 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

95 50 49 SR 534 Collector 580 1

12 4

1575 35 8

96 50 51 SR 534 Collector 1858 1

12 4

1575 35 8

97 51 50 SR 534 Collector 1864 1

12 4

1575 35 8

98 51 52 SR 534 Collector 2771 1

12 4

1700 40 3

99 52 51 SR 534 Collector 2770 1

12 4

1700 40 3

100 52 53 SR 534 Collector 2666 1

12 4

1700 50 3

101 53 52 SR 534 Collector 2676 1

12 4

1700 50 3

102 53 54 SR 534 Collector 2557 1

12 4

1700 50 3

103 54 53 SR 534 Collector 2528 1

12 4

1700 50 3

104 54 55 SR 534 Collector 930 1

12 4

1700 50 3

105 55 54 SR 534 Collector 898 1

12 4

1700 50 3

106 55 56 SR 534 Collector 2233 1

12 4

1700 50 3

107 56 55 SR 534 Collector 2226 1

12 4

1700 50 3

108 56 57 SR 534 Collector 2535 1

12 4

1700 50 2

109 57 56 SR 534 Collector 2534 1

12 4

1700 50 2

110 57 373 SR 534 Collector 511 1

12 4

1700 50 2

111 58 59 SR 531 Local Roadway 1510 1

12 4

1350 30 2

112 58 372 SR 534 Local Roadway 531 1

12 4

1350 30 2

113 59 58 SR 531 Local Roadway 1509 1

12 4

1350 30 2

114 59 60 SR 531 Local Roadway 352 1

12 4

1125 25 3

115 60 59 SR 531 Local Roadway 352 1

12 4

1125 25 3

116 60 370 SR 531 Local Roadway 1583 1

12 4

1125 25 3

117 61 62 SR 531 Local Roadway 403 1

12 4

1125 25 3

118 62 369 SR 531 Local Roadway 1681 1

12 4

1125 25 3

119 63 368 SR 531 Local Roadway 285 1

12 4

1350 30 3

Perry Nuclear Power Plant Evacuation Time Estimate K-42 KLD Engineering, P.C.

Rev. 2

120 64 65 SR 531 Collector 3569 1

1 4

1575 35 121 65 66 SR 531 Collector 2988 1

12 4

1700 45 3

122 66 67 SR 531 Collector 4404 1

12 4

1700 45 3

123 67 68 SR 531 Collector 1282 1

12 4

1700 45 3

124 68 69 SR 531 Collector 3569 1

12 4

1700 45 3

125 69 70 SR 531 Collector 3204 1

12 4

1700 45 4

126 70 435 SR 531 Collector 1723 1

12 4

1700 45 4

127 72 449 S Eagle St Local Roadway 1694 1

12 4

1125 25 8

128 73 445 US-20 Collector 1510 1

12 4

1575 35 8

129 73 447 US-20 Local Roadway 1152 1

12 4

1575 35 8

130 74 75 US-20 Minor Arterial 3679 2

12 4

1900 50 8

131 74 445 US-20 Collector 2285 1

12 4

1575 35 8

132 75 74 US-20 Minor Arterial 3679 2

12 4

1900 50 8

133 75 76 US-20 Minor Arterial 4089 2

12 4

1900 50 8

134 75 86 CR 9 Collector 3980 1

12 4

1700 40 8

135 76 75 US-20 Minor Arterial 4090 2

12 4

1900 50 8

136 76 77 US-20 Minor Arterial 6207 2

12 4

1900 50 3

137 77 76 US-20 Minor Arterial 6208 2

12 4

1900 50 3

138 77 443 US-20 Minor Arterial 2931 2

12 4

1900 50 3

139 78 434 SR 45 Collector 3384 1

12 4

1700 50 4

140 78 440 SR 45 Collector 1355 1

12 4

1700 50 4

141 78 442 US-20 Minor Arterial 1133 2

12 4

1900 50 4

142 78 993 US-20 Minor Arterial 2787 1

12 4

1900 45 4

143 79 993 US-20 Minor Arterial 4261 2

12 4

1900 50 4

Exit Link 79 8079 US-20 Minor Arterial 1488 2

12 4

1900 35 4

Perry Nuclear Power Plant Evacuation Time Estimate K-43 KLD Engineering, P.C.

Rev. 2

144 80 32 SR 84 Collector 660 1

12 4

1700 40 8

145 80 753 SR 84 Collector 1842 1

12 4

1700 40 8

146 81 82 SR 84 Collector 926 1

12 4

1700 40 8

147 81 753 SR 84 Collector 708 1

12 4

1700 40 8

148 82 81 SR 84 Collector 926 1

12 4

1700 40 8

149 82 83 SR 84 Local Roadway 876 1

12 4

1350 30 8

150 83 82 SR 84 Local Roadway 874 1

12 4

1350 30 8

151 83 84 SR 84 Collector 1362 1

12 4

1700 40 8

152 84 83 SR 84 Collector 1368 1

12 4

1700 40 8

153 84 85 SR 84 Collector 2793 1

12 4

1700 50 8

154 85 84 SR 84 Collector 2793 1

12 4

1700 50 8

155 209 837 SR 44 Collector 2754 1

12 4

1700 60 24 156 210 22 1-90 Freeway 12549 2

12 4

2250 70 24 157 210 966 1-90 Freeway 821 2

12 8

2250 55 24 1-90 on-ramp from SR 158 211 21 44 Freeway Ramp 727 1

12 4

1125 25 24 SR 44 on-ramp from 159 211 207 1-90 Freeway Ramp 468 1

12 4

1700 40 24 SR 44 on-ramp from 160 212 196 SR 2 Freeway 1618 2

12 4

2250 45 13 SR 2 on-ramp from 161 213 182 SR 44 Freeway Ramp 1418 1

12 4

1700 45 13 SR 2 on-ramp from 162 213 183 SR 44 Freeway Ramp 2204 1

12 4

1700 45 13 163 214 215 SR 44 Collector 6366 1

12 4

1700 60 24 164 215 216 SR 44 Collector 3509 1

12 4

1700 60 31 165 216 217 SR 44 Collector 2007 1

12 4

1700 60 32 Perry Nuclear Power Plant Evacuation Time Estimate K-44 KLD Engineering, P.C.

Rev. 2

Up Don urto Fre 0Grid 166 198 199 SR 44 Freeway 2605 2

12 4

2250 60 14 SR 44 off-ramp to SR 167 198 486 20 Freeway Ramp 919 1

12 4

1700 40 14 168 199 198 SR 44 Freeway 2605 2

12 4

2250 55 14 169 199 200 SR 44 Freeway 1241 2

12 4

2250 60 14 170 200 199 SR 44 Freeway 1241 2

12 4

2250 60 14 171 200 201 SR 44 Freeway 3043 2

12 4

2250 55 24 172 226 8226 SR 44 Collector 1440 1

12 4

1575 35 32 173 227 228 US-20 Minor Arterial 4152 2

12 4

1900 50 5

174 227 243 US-20 Minor Arterial 3690 2

12 4

1900 50 5

175 228 227 US-20 Minor Arterial 4154 2

12 4

1900 50 5

176 228 229 US-20 Minor Arterial 1467 2

12 4

1900 50 5

177 229 228 US-20 Minor Arterial 1467 2

12 4

1900 50 5

178 229 230 US-20 Minor Arterial 1546 2

12 4

1900 50 5

179 229 974 Lane Rd Collector 1928 1

12 4

1700 40 5

180 230 229 US-20 Minor Arterial 1546 2

12 4

1900 50 5

181 230 231 US-20 Minor Arterial 1418 2

12 4

1900 50 15 182 231 230 US-20 Minor Arterial 1418 2

12 4

1900 50 15 183 231 232 US-20 Minor Arterial 1809 2

12 4

1900 50 15 184 232 231 US-20 Minor Arterial 1809 2

12 4

1900 50 15 185 232 235 SR 2 Collector 1710 1

12 4

1700

,45 15 186 232 466 US-20 Collector 1537 1

12 4

1700 45 15 187 I 233 I232 1US-20 Minor Arterial 1 3851 2

12 4

1900 50 1 15 188 233 24 US-20 Minor Arterial 992 2

12 4

1900 501 15 189 234 j 233 US-20 Minor Arterial 992 2

12 4

1900 50 15 190 734 j 537 Water_____St_

Local Roadway 304 1

12 4

900 20 11 Perry Nuclear Power Plant K-45 KID Engineering, P.C.

Evacuation Time Estimate Rev. 2

191 735 551 SR 535 Collector 352 1

12 4

1700 40 12 192 736 549 SR 535 Collector 1022 1

12 4

1700 40 12 193 737 546 Hardy Rd Collector 1150 1

12 4

1700 40 15 194 738 737 Hardy Rd Local Roadway 178 1

12 4

900 20 15 195 739 555 SR 535 Collector 412 1

12 4

1700 40 15 196 740 741 SR 535 Local Roadway 144 1

12 4

900 20 15 197 741 557 SR 535 Collector 647 1

12 4

1700 40 15 198 742 558 Bacon Rd Collector 3099 1

12 4

1700 45 5

199 743 234 CR 305 Collector 2048 1

12 4

1575 35 15 200 743 744 CR 305 Local Roadway 204 1

12 4

900 20 15 201 744 743 CR 305 Local Roadway 204 1

12 4

900 20 15 202 744 745 CR 305 Collector 682 1

12 4

1575 35 15 203 745 744 CR 305 Collector 682 1

12 4

1575 35 15 204 745 746 CR 305 Collector 294 1

12 4

1575 35 15 205 746 745 CR 305 Collector 294 1

12 4

1575 35 15 206 746 747 CR 305 Collector 2257 1

12 4

1575 35 15 207 747 291 CR 305 Collector 683 1

12 4

1575 35 15 208 747 746 CR 305 Collector 2257 1

12 4

1575 35 15 209 748 284 Madison Ave Collector 2090 1

12 4

1700 40 15 210 748 749 Madison Ave Local Roadway 203 1

12 4

900 20 15 211 749 283 Madison Ave Collector 1203 1

12 4

1700 40 15 212 749 748 Madison Ave Local Roadway 203 1

12 4

900 20 15 213 750 254 SR 84 Collector 2773 1

12 4

1700 50 6

214 750 751 SR 84 Collector 5414 1

12 4

1575 35 6

215 750 991 Dayton Rd Collector 447 1

12 4

1700 40 6

Perry Nuclear Power Plant Evacuation Time Estimate K-46 KLD Engineering, P.C.

Rev. 2

Up Don urto Fre Grid0 Strea Stea LengthN.

ofLn Shole Flo Flo Map 216 751 98 SR 84 Local Roadway 616 1

12 4

1575 35 7

217 751 750 SR 84 Collector 5410 1

12 4

1575 35 6

218 752 97 Saxton St Local Roadway 749 1

12 4

1125 25 7

219 753 80 SR 84 Collector 1850 1

12 4

1700 40 8

220 753 81 SR 84 Collector 717 1

12 4

1700 40 8

221 754 753 Sherman St Local Roadway 737 1

12 4

1125 25 8

222 755 430 SR 307 Collector 1765 1

12 4

1700 40 9

223 756 755 SR 307 Collector 419 1

12 4

1575 35 9

224 757 756 SR 307 Collector 4348 1

12 4

1700 60 8

225 758 757 SR 307 Collector 269 1

12 4

1700 45 8

226 902 903 SR 608 Collector 2606 1

12 4

1700 40 33 227 903 8903 SR 608 Collector 613 1

12 4

1700 40 33 228 904 905 SR 86 Collector 1311 1

12 4

1700 40 15 229 905 906 SR 86 Collector 1373 1

12 4

1700 40 25 230 906 907 SR 86 Collector 1441 1

12 4

1700 40 25 231 907 908 SR 86 Collector 1020 1

12 4

1700 40 25 232 908 909 SR 86 Collector 5205 1

12 4

1700 40 25 233 909 910 SR 86 Collector 3154 1

12 4

1700 55 25 234 910 270 SR 86 Collector 4613 1

12 4

1700 55 25 235 911 854 Center St Collector 330 1

12 4

1575 35 10 236 911 912 Hendricks Rd Collector 1640 1

12 4

1700 40 10 237 912 323 Hendricks Rd Collector 3625 1

12 4

1700 40 10 238 85 86 SR 84 Collector 1505 1

12 4

1700 50 8

239 86 75 CR 9 Collector 3980 1

12 4

1700 40 8

240 86 85 SR 84 Collector 1508 1

12 4

1700 50 8

Perry Nuclear Power Plant Evacuation Time Estimate K-47 KLD Engineering, P.C.

Rev. 2

241 86 87 SR 84 Collector 1504 1

12 4

1700 55 8

242 87 86 SR 84 Collector 1504 1

12 4

1700 50 8

243 87 88 SR 84 Collector 943 1

12 4

1700 55 8

244 88 87 SR 84 Collector 943 1

12 4

1700 55 8

245 88 89 SR 84 Collector 2159 1

12 4

1700 55 8

246 89 88 SR 84 Collector 2159 1

12 4

1700 55 8

247 89 90 SR 84 Collector 5948 1

12 4

1700 55 8

248 90 89 SR 84 Collector 5948 1

12 4

1700 55 8

249 90 91 SR 84 Collector 3714 1

12 4

1700 55 9

250 91 90 SR 84 Collector 3714 1

12 4

1700 55 9

251 91 444 SR 84 Collector 846 1

12 4

1700 45 9

252 92 93 SR 84 Collector 991 1

12 4

1700 55 9

253 92 444 SR 84 Collector 959 1

12 4

1700 40 9

254 93 92 SR 84 Collector 992 1

12 4

1700 45 9

255 93 94 SR 84 Collector 2076 1

12 4

1700 55 9

256 94 93 SR 84 Collector 2074 1

12 4

1700 55 9

257 94 433 SR 45 Collector 1073 1

12 4

1700 55 9

258 94 439 SR 84 Collector 1397 1

12 4

1700 55 4

259 94 441 SR 45 Collector 3602 1

12 4

1700 50 4

1-90 on-ramp from SR 260 95 10 528 Freeway Ramp 910 1

12 4

1700 40 17 261 95 136 SR 528 Collector 1134 1

12 4

1700 40 17 262 96 361 SR 528 Collector 889 1

12 4

1700 40 7

263 97 96 SR 528 Collector 2325 1

12 4

1700 40 7

264 97 98 SR 528 Local Roadway 848 1

12 4

1575 35 7

265 98 97 SR 528 Local Roadway 848 1

12 4

1575 35 7

Perry Nuclear Power Plant Evacuation Time Estimate K-48 KLD Engineering, P.C.

Rev. 2

266 98 99 SR 84 Local Roadway 799 1

12 4

1575 35 7

267 98 751 SR 84 Local Roadway 620 1

12 4

1575 35 7

268 99 98 SR 84 Local Roadway 799 1

12 4

1575 35 7

269 99 164 SR 84 Local Roadway 2367 1

12 4

1575 35 7

Exit Link 99 775 SR 528 Local Roadway 972 1

12 4

1350 30 7

270 100 101 SR 528 Collector 1337 1

12 4

1575 35 7

271 100 777 SR 528 Collector 2413 1

12 4

1575 35 7

272 101 100 SR 528 Collector 1337 1

12 4

1575 35 7

273 101 778 SR 528 Collector 2478 1

12 4

1700 40 7

274 101 988 CR 22 Collector 2598 1

12 4

1575 35 7

275 102 109 US-20 Minor Arterial 4571 2

12 4

1900 35 7

276 102 456 US-20 Minor Arterial 828 2

12 4

1900 35 7

277 102 778 SR 528 Collector 2056 1

12 4

1700 40 7

278 103 102 CR 7 Collector 6431 1

12 4

1700 40 7

279 103 108 CR 26 Collector 4469 1

12 4

1700 40 7

280 104 103 CR 7 Collector 5995 1

12 4

1700 40 2

281 105 104 CR 30 Local Roadway 1290 1

12 4

1125 25 2

282 106 105 CR 30 Collector 1355 1

12 4

1575 35 2

283 106 107 CR 30 Collector 2104 1

12 4

1575 35 2

284 107 108 CR 5 Collector 6670 1

12 4

1700 40 2

285 108 109 CR 5 Collector 7263 1

12 4

1700 40 7

286 108 133 CR 26 Collector 4488 1

12 4

1700 40 7

287 109 102 US-20 Minor Arterial 4571 2

12 4

1900 35 7

288 109 128 US-20 Minor Arterial 4425 2

12 4

1900 45 7

289 110 106 Davista Ave Local Roadway 2051 1

12 4

1125 25 2

Perry Nuclear Power Plant Evacuation Time Estimate K-49 KLD Engineering, P.C.

Rev. 2

Up Don urto Fre Grida 290 ill 112 CR 30 Collector 1265 1

12 4

1575 35 1

291 112 113 CR 30 Collector 2000 1

12 4

1575 35 1

292 113 104 CR 30 Local Roadway 894 1

12 4

1125 25 1

293 114 111 Red Bird Rd Collector 1776 1

12 4

1575 35 1

294 114 116 Red Bird Rd Collector 2363 1

12 4

1575 35 6

295 115 114 Maxwell Dr Local Roadway 792 1

12 4

1125 25 6

296 116 103 CR 26 Collector 3551 1

12 4

1700 40 6

297 116 117 CR 26 Collector 3434 1

12 4

1575 35 6

298 117 116 CR 26 Collector 3434 1

12 4

1575 35 6

299 117 118 CR 13 Collector 6681 1

12 4

1575 35 6

300 118 458 L.1-20 Minor Arterial 2229 12 12 4

1900 50 6

301 282 784 E Walnut St Collector 686 1

12 4

1575 35 15 302 282 785 SR 86 Collector 1256 1

12 4

1575 35 14 303 282 786 SR 86 Collector 1058 1

12 4

1575 35 14 304 283 261 Madison Ave Collector 1928 1

12 4

1700 40 15 305 283 749 Madison Ave Collector 1202 1

12 4

1700 40 15 306 284 285 Madison Ave Collector 5927 1

12 4

1700 40 15 307 284 291 County Hwy 305 Collector 2230 1

12 4

1575 35 15 308 284 748 Madison Ave Collector 2089 1

12 4

1700 40 15 309 285 286 Main St Collector 1012 1

12 4

1700 40 15 310 286 287 Main St Collector 828 1

12 4

1575 35 15 311 287 288 Main St Collector 726 1

12 4

15S7 35 14 312 181 182 SR 2 Freeway 4326 2

12 4

2250 55 14 313 182 181 SR 2 Freeway 4326 2

12 4

2250 55 14 314 182 183

,SR 2 Freeway 2658 2

12 4

2250 55 13 Perry Nuclear Power Plant K-5O KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

SR 2 off-ramp to SR 45 315 182 212 144 Freeway Ramp 2071 1

12 4

1700 13 316 183 182 SR 2 Freeway 2658 2

12 4

2250 55 13 317 183 184 SR 2 Freeway 2496 2

12 4

2250 55 13 SR 2 off-ramp to SR 318 183 212 44 Freeway Ramp 1433 1

12 4

1700 45 13 319 184 183 SR 2 Freeway 2496 2

12 4

2250 55 13 320 184 185 SR2 Freeway 2044 2

12 4

2250 55 13 SR 2 off-ramp to 321 184 510 Heisley Rd Freeway Ramp 704 1

12 4

1700 40 13 322 185 184 SR 2 Freeway 2044 2

12 4

2250 55 13 323 185 186 SR 2 Freeway 1454 2

12 4

2250 55 13 Heisley Rd on-ramp 324 185 509 from SR 2 Freeway Ramp 781 1

12 4

1700 40 13 325 186 185 SR 2 Freeway 1453 2

12 4

2250 55 13 326 186 187 SR 2 Freeway 6843 2

12 4

2250 55 24 327 187 186 SR 2 Freeway 6843 2

12 4

2250 55 24 328 187 188 SR 2 Freeway 1591 2

12 4

2250 55 24 329 188 187 SR 2 Freeway 1595 2

12 4

2250 55 24 330 188 189 SR 2 Freeway 4031 2

12 4

2250 55 21 331 189 188 SR 2 Freeway 4031 2

12 4

2250 55 21 332 189 190 SR 2 Freeway 2066 2

12 4

2250 55 21 SR 2 off-ramp to SR 333 189 641 615 Freeway Ramp 1252 1

12 4

1700 40 21 334 190 189 SR 2 Freeway 2071 2

12 4

2250 55 21 335 190 191 SR 2 Freeway 2387 2

12 4

2250 55 21 Perry Nuclear Power Plant Evacuation Time Estimate K-51 KLD Engineering, P.C.

Rev. 2

Up Don urto Fre Grid5.

Strea Stea Legt No.

of Lane Shole Flo Flo Map SR 2 off-ramp to SR 336 190 642 615 Freeway Ramp 725 1

12 4

1700 40 21 337 191 190 SR 2 Freeway 2387 2

12 4

2250 55 21 338 191 192 SR 2 Freeway 2117 2

12 4

2250 55 21 339 192 191 SR 2 Freeway 2116 2

12 4

2250 55 21 340 192 193 SR 2 Freeway 7695 2

12 4

2250 55 21 341 193 192 SR 2 Freeway 7695 2

12 4

2250 55 21 342 193 194 SR 2 Freeway 1774 2

12 4

2250 55 22 SR 2 off-ramp to SR 343 193 687 306 Freeway Ramp 640 1

12 4

1700 40 22 344 194 193 SR 2 Freeway 1774 2

12 4

2250 55 22 345 194 195 SR 2 Freeway 1877 2

12 4

2250 55 22 SR 306 on-ramp from 346 194 688 SR 2 Freeway Ramp 672 1

12 4

1700 40 22 347 195 194 SR 2 Freeway 1877 2

12 4

2250 55 22 348 195 8195 SR 2 Freeway 1761 2

12 4

2250 55 22 349 196 197 SR 44 Freeway 1202 2

1 12 4

2250 60 1

13 SR 44 off-ramp to SR 350 196 213 2

Freeway Ramp 1470 2

12 4

2250 45 13 351 197 196 SR 44 Freeway 1202 2

12 4

2250 60 13 352 197 198 SR 44 Freeway 1558 2

12 4

2250 55 14 353 198 197 SR 44 Freeway 1558 2

12 4

2250 60 14 354 234 293 US-20 Minor Arterial 1810 2

12 4

1900 40 15 355 234 743 County Hwy 305 Collector 2048 1

12 4

1575 35 15 356 235 174 SR 2 Freeway 1537 2

12 8

2250 55 15 US-20 on-ramp from 357 235 232 SR 2 Freeway Ramp 1822 1

12 4

1700 50 15 Perry Nuclear Power Plant K-52 Evacuation Time Estimate KLD Engineering, P.C.

Rev. 2

358 236 237 CR 106 Collector 2399 1

12 4

1700 40 5

359 236 967 CR 115 Collector 2400 1

12 4

1700 40 5

360 237 238 CR 106 Collector 2361 1

12 4

1700 40 6

361 238 239 CR 106 Collector 2698 1

12 4

1700 40 6

362 239 780 CR 106 Collector 1743 1

12 4

1700 40 6

Exit Link 240 241 CR 106 Collector 1780 1

12 4

1700 40 16 363 241 253 SR 84 Collector 3961 1

12 4

1700 50 16 364 241 256 SR 84 Collector 2810 1

12 4

1700 50 16 365 242 236 CR 115 Collector 3355 1

12 4

1700 40 5

366 242 244 CR 22 Collector 2461 1

12 4

1700 40 5

367 243 170 US-20 Minor Arterial 1358 2

12 4

1900 50 5

368 243 227 US-20 Minor Arterial 3690 2

12 4

1900 50 5

369 244 245 CR 22 Collector 2300 1

12 4

1700 40 6

370 245 238 CR 109 Collector 3326 1

12 4

1714 40 6

371 245 246 CR 22 Collector 4721 1

12 4

1700 40 6

372 246 247 CR 22 Collector 2393 1

12 4

1700 40 6

373 247 165 CR 19 Collector 3610 1

12 4

1700 40 6

Exit Link 247 252 CR 19 Freeway 6638 1

12 4

1575 35 6

374 118 460 US-20 Minor Arterial 6103 2

12 4

1900 50 6

375 119 117 CR 13 Collector 1100 1

12 4

1575 35 6

376 120 119 Douglas Dr Local Roadway 966 1

12 4

1125 25 6

377 121 120 Meadows Rd Local Roadway 2369 1

12 4

1125 25 1

378 121 122 Shore Dr Local Roadway 531 1

12 4

1125 25 1

379 122 111 Shore Dr Collector 2234 1

12 4

1575 35 1

K-53 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-53 KLD Engineering, P.C.

Rev. 2

380 123 121 Shore Dr Local Roadway 966 1

24 1125 251 381 124 452 US-20 Collector 2487 1

12 4

1700 40 8

382 124 725 US-20 Minor Arterial 1389 2

12 4

1900 50 7

383 125 725 US-20 Minor Arterial 983 2

12 4

1900 50 7

384 125 980 US-20 Minor Arterial 2738 2

12 4

1900 45 7

385 126 127 US-20 Minor Arterial 3510 2

12 4

1900 45 7

386 126 980 US-20 Minor Arterial 1554 2

12 4

1900 50 7

387 127 126 US-20 Minor Arterial 3510 2

12 4

1900 45 7

388 127 128 US-20 Minor Arterial 3753 2

12 4

1900 45 7

389 127 987 CR 141 Local Roadway 3784 1

12 4

1575 35 7

390 128 109 US-20 Minor Arterial 4425 2

12 4

1900 45 7

391 128 127 US-20 Minor Arterial 3753 2

12 4

1900 45 7

392 129 107 CR 5 Collector 1112 1

12 4

1575 35 2

393 130 129 CR 32 Collector 4054 1

12 4

1575 35 2

394 130 131 CR 32 Collector 2327 1

12 4

1575 35 2

395 131 134 CR 1 Collector 469 1

12 4

1575 35 2

396 132 133 CR 1 Collector 1951 1

12 4

1700 40 7

397 132 976 Cunningham Rd Collector 3907 1

12 4

1700 40 7

398 133 128 CR 1 Collector 7932 1

12 4

1700 40 7

399 133 132 CR 1 Collector 1951 1

12 4

1700 40 7

400 134 132 CR 1 Collector 5875 1

12 4

1700 40 2

401 135 130 Maple Ave Local Roadway 1278 1

12 4

1125 25 2

402 136 137 SR 528 Collector 3720 1

12 4

1700 40 17 403 136 773 SR 307 Collector 762 1

12 4

1700 40 17 404 137 138 SR 528 Collector 2572 1

12 4

1700 40 17 Perry Nuclear Power Plant K-54 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

405 138 139 SR 528 Collector 1188 1

12 4

1700 40 17 406 139 140 SR 528 Collector 977 1

12 4

1700 40 17 407 140 141 SR 528 Collector 3618 1

12 4

1700 40 17 408 141 142 SR 528 Collector 3354 1

12 4

1700 40 17 409 142 143 SR 528 Collector 3716 1

12 4

1700 40 17 410 143 144 SR 528 Collector 1573 1

12 4

1700 40 17 411 144 145 SR 528 Collector 3621 1

12 4

1700 40 17 412 145 146 SR 528 Local Roadway 777 1

12 4

1125 25 27 413 389 721 Township Hwy 211 Collector 1069 1

12 4

1700 40 2

414 390 387 Lake Rd W Collector 572 1

12 4

1700 40 2

415 391 387 Driveway Local Roadway 255 1

12 4

900 20 2

416 392 31 SR 534 Collector 1605 1

12 4

1575 35 8

417 392 393 SR 534 Local Roadway 153 1

12 4

600 15 8

418 247 986 CR 22 Collector 2647 1

12 4

1575 35 6

419 248 249 CR 22 Collector 1528 1

12 4

1575 35 6

420 249 250 CR 22 Collector 1824 1

12 4

1575 35 6

421 250 459 CR 22 Collector 1666 1

12 4

1575 35 6

422 251 101 CR 22 Collector 2453 1

12 4

1575 35 6

423 252 247 CR 19 Collector 6638 1

12 4

1575 35 6

424 252 253 CR 19 Collector 1704 1

12 4

1700 40 6

425 253 241 SR 84 Collector 3961 1

12 4

1700 50 16 426 253 252 CR 19 Collector 1705 1

12 4

1700 40 6

427 253 255 SR 84 Collector 4740 1

12 4

1700 50 6

428 254 255 SR 84 Collector 1558 1

12 4

1700 50 6

429 254 750 SR 84 Collector 2773 1

12 4

1700 50 6

Perry Nuclear Power Plant Evacuation Time Estimate K-55 KLD Engineering, P.C.

Rev. 2

I 430 255 253 SR 84 Collector 4740 1

12 4

1700 50 6

431 255 254 SR 84 Collector 1558 1

12 4

1700 50 6

432 256 241 SR 84 Collector 2810 1

12 4

1700 50 16 433 256 970 SR 84 Collector 1987 1

12 4

1700 50 16 434 257 258 SR 84 Collector 4553 1

12 4

1700 50 15 435 257 970 SR 84 Collector 3135 1

12 4

1700 50 16 436 258 257 SR 84 Collector 4553 1

12 4

1700 50 15 437 258 259 SR 84 Collector 3716 1

12 4

1700 50 15 438 259 258 SR 84 Collector 3716 1

12 4

1700 50 15 439 259 260 SR 84 Collector 4247 1

12 4

1700 50 15 440 260 259 SR 84 Collector 4247 1

12 4

1700 50 15 441 260 261 SR 84 Collector 1883 1

12 4

1700 50 15 442 261 260 SR 84 Collector 1880 1

12 4

1700 50 15 443 261 271 CR 227 Local Roadway 209 1

12 4

1350 30 15 444 261 272 SR 84 Collector 547 1

12 4

1700 40 15 445 261 283 Madison Ave Collector 1934 1

12 4

1700 40 15 446 262 263 CR 227 Collector 606 1

12 4

1575 35 15 447 263 264 CR 227 Local Roadway 684 1

12 4

1350 30 15 448 264 265 CR 227 Local Roadway 631 1

12 4

1350 30 15 449 265 266 CR 227 Collector 601 1

12 4

1375 35 15 450 266 267 CR 227 Collector 3072 1

12 4

1700 40 15 451 267 268 CR 227 Collector 1696 1

12 4

1700 40 15 1-90 on-ramp from CR 452 268 19 227 Freeway Ramp 695 1

12 4

1575 35 15 453 268 358 CR 227 Collector 695 1

12 4

1700 40 15 454 269 270 CR 227 Collector 5094 1

12 4

1700 40 15 Perry Nuclear Power Plant Evacuation Time Estimate K-56 KLD Engineering, P.C.

Rev. 2

455 270 701 SR 86 Collector 9622 1

12 4

1700 60 25 456 271 262 CR 227 Local Roadway 585 1

12 4

1350 30 15 457 272 261 SR 84 Collector 547 1

12 4

1700 50 15 458 288 289 Main St Collector 861 1

12 4

1575 35 14 459 289 290 Main St Local Roadway 685 1

12 4

1125 25 14 460 290 299 SR 86 Local Roadway 1312 1

12 4

1125 25 14 461 290 476 Main St Local Roadway 404 1

12 4

1125 25 14 462 290 804 SR 86 Local Roadway 673 1

12 4

1125 25 14 463 291 284 County Hwy 305 Collector 2230 1

12 4

1575 35 15 464 291 747 County Hwy 305 Collector 683 1

12 4

1575 35 15 465 292 273 Mountainside Dr Collector 606 1

12 4

1575 35 15 466 293 234 US-20 Minor Arterial 1810 2

12 4

1900 40 15 467 293 294 US-20 Minor Arterial 1425 2

12 4

1900 45 15 US-20 off-ramp to SR 468 293 300 2

Collector 1191 1

12 4

1700 40 15 469 294 293 US-20 Minor Arterial 1423 2

12 4

1900 40 15 470 294 470 US-20 Minor Arterial 1383 2

12 4

1900 45 15 471 295 296 US-20 Collector 612 1

12 4

1575 35 15 472 295 471 US-20 Minor Arterial 1491 2

12 4

1900 45 15 473 296 295 US-20 Collector 602 1

12 4

1575 35 15 474 296 472 US-20 Local Roadway 537 1

12 4

1350 30 15 475 297 472 US-20 Collector 2486 1

12 4

1700 40 15 476 297 473 US-20 Collector 926 1

12 4

1575 35 14 477 298 299 US-20 Collector 1738 1

12 4

1575 35 14 478 298 473 US-20 Local Roadway 249 1

12 4

1125 25 14 479 299 290 SR 86 Local Roadway 1312 1

12 4

1125 25 14 Perry Nuclear Power Plant Evacuation Time Estimate K-57 KLD Engineering, P.C.

Rev. 2

Stra

  • Stra Lengt No of LaneS.

Shole Flo Flo Map 480 299 298 US-20 Collector 1738 1

12 4

1575 35 14 481 299 474 N State St Local Roadway 220 1

12 4

1125 25 14 482 299 475 US-20 Local Roadway 575 1

12 4

1125 25 14 483 300 293 SR 535 Collector 1190 1

12 4

1700 40 15 SR 2 on-ramp from 484 300 301 US-20 Collector 708 1

12 4

1575 35 15 SR 2 on-ramp from 485 301 175 US-20 Freeway Ramp 861 1

12 4

1575 35 15 486 302 309 Liberty St Minor Arterial 380 2

12 4

1900 35 14 487 302 475 US-20 Local Roadway 1228 1

12 4

1125 25 14 488 302 477 SR 535 Collector 542 2

12 4

1900 35 14 489 302 478 US-20 Collector 811 1

12 4

1575 35 14 490 303 478 US-20 Collector 333 1

12 4

1575 35 14 491 303 480 US-20 Collector 1528 1

12 4

1575 35 14 492 304 305 US-20 Collector 1058 2

12 4

1575 35 14 458 288 289 Main St Collector 861 1

12 4

1575 35 14 459 289 290 Main St Local Roadway 685 1

12 4

1125 25 14 460 290 299 SR 86 Local Roadway 1312 1

12 4

1125 25 14 461 290 476 Main St Local Roadway 404 1

12 4

1125 25 14 462 290 804 SR 86 Local Roadway 673 1

12 4

1125 25 14 463 291 284 County Hwy 305 Collector 2230 1

12 4

1575 35 15 464 291 747 County Hwy 305 Collector 683 1

12 4

1575 35 15 465 292 273 Mountainside Dr Collector 606 1

12 4

1575 35 15 466 293 234 US-20 Minor Arterial 1810 2

12 4

1900 40 15 467 293 294 US-20 Minor Arterial 1425 2

12 4

1900 45 15 Perry Nuclear Power Plant Evacuation Time Estimate K-58 KLD Engineering, P.C.

Rev. 2

US-20 off-ramp to SIR 468 293 300 2

Collector 1191 2

12 4

1700 40 15 469 294 293 US-20 Minor Arterial 1423 2

12 4

1900 40 15 470 294 470 US-20 Minor Arterial 1383 2

12 4

1900 45 15 471 295 296 US-20 Collector 612 1

12 4

1575 35 15 472 295 471 US-20 Minor Arterial 1491 2

12 4

1900 45 15 473 296 295 US-20 Collector 602 1

12 4

1575 35 15 474 296 472 US-20 Local Roadway 537 1

12 4

1350 30 15 475 297 472 US-20 Collector 2486 1

12 4

1700 40 15 476 297 473 US-20 Collector 926 1

12 4

1575 35 14 477 298 299 US-20 Collector 1738 1

12 4

1575 35 14 478 298 473 US-20 Local Roadway 249 1

12 4

1125 25 14 479 299 290 SR 86 Local Roadway 1312 1

12 4

1125 25 14 480 299 298 US-20 Collector 1738 1

12 4

1575 35 14 481 299 474 N State St Local Roadway 220 1

12 4

1125 25 14 482 299 475 US-20 Local Roadway 575 1

12 4

1125 25 14 483 300 293 SR 535 Collector 1190 1

12 4

1700 40 15 SR 2 on-ramp from 484 300 301 US-20 Collector 708 1

12 4

1575 35 15 SR 2 on-ramp from 485 301 175 US-20 Freeway Ramp 861 1

12 4

1575 35 15 486 302 309 Liberty St Minor Arterial 380 2

12 4

1900 35 14 487 302 475 US-20 Local Roadway 1228 1

12 4

1125 25 14 488 302 477 SR 535 Collector 542 2

12 4

1900 35 14 489 302 478 US-20 Collector 811 1

12 4

1575 35 14 490 303 478 US-20 Collector 333 1

12 4

1575 35 14 K-59 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-59 KLD Engineering, P.C.

Rev. 2

491 303 480 US-20 Collector 1528 1

12 4

1575 35 14 492 304 305 US-20 Collector 1058 2

12 4

1575 35 14 458 288 289 Main St Collector 861 1

12 4

1575 35 14 459 289 290 Main St Local Roadway 685 1

12 4

1125 25 14 460 290 299 SR 86 Local Roadway 1312 1

12 4

1125 25 14 461 290 476 Main St Local Roadway 404 1

12 4

1125 25 14 462 290 804 SR 86 Local Roadway 673 1

12 4

1125 25 14 463 291 284 County Hwy 305 Collector 2230 1

12 4

1575 35 15 464 291 747 County Hwy 305 Collector 683 1

12 4

1575 35 15 465 292 273 Mountainside Dr Collector 606 1

12 4

1575 35 15 466 293 234 US-20 Minor Arterial 1810 2

12 4

1900 40 15 467 293 294 US-20 Minor Arterial 1425 2

12 4

1900 45 15 US-20 off-ramp to SR 468 293 300 2

Collector 1191 1

12 4

1700 40 15 469 294 293 US-20 Minor Arterial 1423 2

12 4

1900 40 15 470 294 470 US-20 Minor Arterial 1383 2

12 4

1900 45 15 471 295 296 US-20 Collector 612 1

12 4

1575 35 15 472 295 471 US-20 Minor Arterial 1491 2

12 4

1900 45 15 473 296 295 US-20 Collector 602 1

12 4

1575 35 15 474 296 472 US-20 Local Roadway 537 1

12 4

1350 30 15 475 297 472 US-20 Collector 2486 1

12 4

1700 40 15 476 297 473 US-20 Collector 926 1

12 4

1575 35 14 477 298 299 US-20 Collector 1738 1

12 4

1575 35 14 478 298 473 US-20 Local Roadway 249 1

12 4

1125 25 14 479 299 290 SR 86 Local Roadway 1312 1

12 4

1125 25 14 480 299 298 US-20 Collector 1738 1

12 4

1575 35 14 K-60 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-60 KLD Engineering, P.C.

Rev. 2

481 299 474 N State St Local Roadway 220 1

24 1125 2514 482 299 475 US-20 Local Roadway 575 1

12 4

1125 25 14 483 300 293 SR 535 Collector 1190 1

12 4

1700 40 15 SR 2 on-ramp from 484 300 301 US-20 Collector 708 1

12 4

1575 35 15 SR 2 on-ramp from 485 301 175 US-20 Freeway Ramp 861 1

12 4

1575 35 15 486 302 309 Liberty St Minor Arterial 380 2

12 4

1900 35 14 487 302 475 US-20 Local Roadway 1228 1

12 4

1125 25 14 488 302 477 SR 535 Collector 542 2

12 4

1900 35 14 489 302 478 US-20 Collector 811 1

12 4

1575 35 14 490 303 478 US-20 Collector 333 1

12 4

1575 35 14 491 303 480 US-20 Collector 1528 1

12 4

1575 35 14 492 304 305 US-20 Collector 1058 2

12 4

1575 35 14 493 272 273 SR 84 Collector 5049 1

12 4

1700 45 15 494 273 272 SR 84 Collector 5049 1

12 4

1700 45 15 495 273 274 SR 84 Collector 1298 1

12 4

1700 45 15 496 274 273 SR 84 Collector 1298 1

12 4

1700 45 15 497 274 275 SR 84 Collector 2084 1

12 4

1700 45 15 1-90 off-ramp to SR 498 364 363 45 Collector 609 1

12 4

1700 40 9

499 365 363 SR 45 Collector 1503 1

12 4

1700 40 9

500 620 645 SR 615 Minor Arterial 2087 2

12 4

1900 35 21 Shopping Center 501 621 605 Driveway Local Roadway 437 1

12 4

1125 25 23 502 622 606 US-20 Minor Arterial 2182 2

12 4

1900 35 23 K-61 KLD Engineering, P.C.

Perry Nuclear Power Plant Evacuation Time Estimate K-61 KLD Engineering, P.C.

Rev. 2

Stea StemLnt

  • o f

Ln Shole Flo Flo Ma.p 503 622 624 US-20 Minor Arterial 1428 2

12 4

1900 35 23 504 623 622 Sharonlee Dr Local Roadway 967 1

12 4

1125 25 23 505 624 622 US-20 Minor Arterial 1428 2

12 4

1900 35 23 506 624 625 Garfield Rd Collector 1527 1

12 4

1575 35 23 507 624 626 US-20 Minor Arterial 858 2

12 4

1900 35 23 508 625 624 1 Garfield Rd Collector 1527 1

12 4

1575 35 23 509 625 659 SR 84 Collector 3392 1

12 4

1700 40 23 510 625 665 SR 84 Collector 304 1

12 4

1700 40 23 511 626 624 US-20 Minor Arterial 858 2

12 4

1900 35 23 512 626 628 US-20 Minor Arterial 873 2

12 4

1900 35 23 513 627 626 Lucretia Ct Local Roadway 400 1

12 4

1125 25 23 514 628 626 US-20 Minor Arterial 873 2

12 4

1900 35 23 515 628 629 US-20 Minor Arterial 1279 2

12 4

1900 35 23 516 146 147 SR 528 Collector 2702 1

12 4

1700 40 27 517 147 148 SR 528 Collector 6247 1

12 4

1700 40 27 518 148 149 SR 528 Collector 8543 1

12 4

1700 40 27 519 148 699 CR 12 Collector 1891 1

12 4

1700 60 27 520 148 954 SR 166 Collector 6380 1

12 4

1700 60 26 521 149 150 SR 528 Collector 5584 1

12 4

1700 40 27 522 150 151 SR 528 Collector 7147 1

12 4

1700 40 34 523 151 152 SR 528 Collector 4999 1

12 4

1700 40 34 524 151 708 US-6 Collector 2224 1

12 4

1700 60 34 525 151 718 US-6 Collector 10207 1

12 4

1700 60 34 526 152 153 SR 528 Collector 2910 1

12 4

1700 40 34 527 152 710 SR 86 Collector 5164 1

12 4

1700 60 34 Perry Nuclear Power Plant Evacuation Time Estimate K-62 KLD Engineering, P.C.

Rev. 2

Stea StemLnt o

f Ln Shole Flo Flo Map 528 153 8153 SR 528 Collector 1968 1

12 4

1575 35 34 529 154 32 SR 84 Collector 2690 1

12 4

1700 40 8

530 154 155 SR 84 Collector-1174 1

12 4

1700 40 8

531 155 154 SR 84 Collector 1173 1

12 4

1700 40 8

532 155 156 SR 84 Collector 933 1

12 4

1700 40 8

533 156 155 SR 84 Collector 915 1

12 4

1700 40 8

534 156 157 SR 84 Collector 1691 1

12 4

1700 40 7

535 157 156 SR 84 Collector 1691 1

12 4

1700 40 7

536 157 158 SR 84 Collector 2349 1

12 4

1700 55 7

537 158 157 SR 84 Collector 2349 1

12 4

1700 55 7

538 158 159 SR 84 Collector 3680 1

12 4

1700 55 7

539 159 158 SR 84 Collector 3680 1

12 4

1700 55 7

540 159 160 SR 84 Collector 2335 1

12 4

1700 55 7

541 160 159 SR 84 Collector 2335 1

12 4

1700 55 7

542 160 161 SR 84 Collector 1035 1

12 4

1700 50 7

543 161 160 SR 84 Collector 1035 1

12 4

1700 50 7

544 161 162 SR 84 Collector 5202 1

12 4

1700 50 7

545 161 768 CR 141 Collector 7555 1

12 4

1575 35 7

546 161 987 CR 141 Collector 3205 1

12 4

1575 35 7

547 162 161 SR 84 Collector 5202 1

12 4

1700 50 7

548 162 163 SIR 84 Collector 773 1

12 4

1700 50 7

549 163 162 SIR 84 Collector 773 1

12 4

1700 50 7

550163 164 1SIR84 Collector 1418611 12 4

117001 401 7

551 164 199 1SIR84 Local Roadway 123671 1

12 4

j1575 35 7

552 164 J163 SR R84 JCollector J41861 1 J12 4

1700 [40 7___

Perry Nuclear Power Plant K-63 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

553 165 166 US-20 Minor Arterial 4831 2

12 4

1900 50 6

554 165 247 CR 19 Collector 3611 1

12 4

1700 40 6

555 165 460 US-20 Minor Arterial 2818 2

12 4

1900 50 6

556 166 165 US-20 Minor Arterial 4831 2

12 4

1900 50 6

557 166 984 US-20 Minor Arterial 2427 2

12 4

1900 50 6

558 167 168 US-20 Minor Arterial 1254 2

12 4

1900 50 6

559 167 984 US-20 Minor Arterial 1067 2

12 4

1900 50 6

560 201 200 SR44 Freeway 3043 2

12 4

2250 60 24 561 201 202 SR 44 Freeway 1555 2

12 4

2250 60 24 SR 84 on-ramp from 562 201 318 SR 44 Freeway Ramp 735 1

12 4

1700 40 24 563 202 201 SR 44 Freeway 1555 2

12 4

2250 55 24 564 202 203 SR 44 Freeway 1619 2

12 4

2250 60 24 SR 44 off-ramp to SR 565 202 317 84 Freeway Ramp 1035 1

12 4

1700 40 24 566 203 202 SR 44 Freeway 1619 2

12 4

2250 60 24 567 203 204 SR 44 Freeway 1893 2

12 4

2250 60 24 568 204 203 SR 44 Freeway 1893 2

12 4

2250 60 24 569 204 205 SR 44 Freeway 3585 2

12 4

2250 60 24 570 205 204 SR 44 Freeway 3585 2

12 4

2250 60 24 571 205 206 SR 44 Freeway 745 2

12 4

1900 60 24 572 206 205 SR 44 Freeway 745 2

12 4

1900 60 24 573 206 207 SR 44 Minor Arterial 1091 2

12 4

1900 45 24 1-90 on-ramp from SR 574 206 210 44 Freeway Ramp 870 1

12 4

1700 45 24 575 207 206 SR 44 Minor Arterial 1091 2

12 4

1900 45 24 Perry Nuclear Power Plant Evacuation Time Estimate K-64 KLD Engineering, P.C.

Rev. 2

Stra Stra Legt No.

ofLn hudr lw Foa SR 44 off-ramp to I-576 207 211 90 Freeway Ramp 468 1

12 4

1700 40 24 577 207 838 SR 44 Minor Arterial 845 2

12 4

1900 45 24 578 208 209 SR 44 Minor Arterial 2233 2

12 4

1900 60 24 579 208 838 SR 44 Minor Arterial 2417 2

12 4

1900 60 24 580 209 208 SR 44 Minor Arterial 2233 2

12 4

1900 60 24 581 217 886 SR 44 Collector 6920 1

12 4

1700 60 32 582 218 835 SR 44 Collector 2163 1

12 4

1575 35 32 583 336 337 Chillicothe Rd Collector 2226 1

12 4

1575 35 24 584 336 506 US-20 Minor Arterial 1208 2

12 4

1900 35 24 585 336 792 US-20 Minor Arterial 1094 2

12 4

1900 35 24 586 337 336 Chillicothe Rd Collector 2226 1

12 4

1575 35 24 587 337 340 Chillicothe Rd Collector 1071 1

12 4

1700 40 24 588 223 226 SR 44 Collector 1772 1

12 4

1575 35 32 589 223 827 US-6 Collector 1475 1

12 4

1575 35 32 590 223 975 S Hambden St Minor Arterial 3452 1

12 4

1575 35 32 591 225 982 Co Rd 4 Collector 872 1

12 4

1700 40 31 592 225 983 US-6 Collector 791 1

12 4

1575 35 31 593 365 429 SR 45 Collector 2715 1

12 4

1575 35 9

594 366 432 SR 45 Collector 2371 1

12 4

1700 55 9

595 367 64 SR 531 Local Roadway 338 1

12 4

1350 30 3

596 368 367 SR 531 Local Roadway 588 1

12 4

1350 30 3

597 369 63 SR 531 Local Roadway 1613 1

12 4

1350 30 3

598 370 60 SR 531 Local Roadway 1583 1

12 4

1125 25 3

599 370 61 SR 531 Local Roadway 2127 1

12 4

1125 25 3

600 371 370 1Golf Ave Local Roadway 694 1

12 4

1125 25 3

Perry Nuclear Power Plant K-65 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

601 372 58 SR 534 Local Roadway 531 1

24 1350 302 602 372 373 SR 534 Collector 983 1

12 4

1700 50 2

603 373 57 SR 534 Collector 511 1

12 4

1700 50 2

604 373 372 SR 534 Collector 983 1

12 4

1700 50 2

605 375 376 Lake Rd Local Roadway 500 1

12 4

900 20 2

606 376 380 Lake Rd Local Roadway 529 1

12 4

1350 30 2

607 377 376 Driveway Local Roadway 304 1

12 4

900 20 2

608 378 379 Township Hwy 211 Local Roadway 2405 1

12 4

1350 30 2

609 379 56 Lake Rd Local Roadway 4054 1

12 4

1350 30 2

610 379 389 Township Hwy 211 Collector 633 1

12 4

1700 40 2

611 380 378 Lake Rd Local Roadway 836 1

12 4

1350 30 2

612 381 380 Driveway Local Roadway 336 1

12 4

900 20 2

613 382 375 Driveway Local Roadway 458 1

12 4

900 20 2

614 383 1 379 1 Lake Rd W I Collector 416 1

12 4

1700 40 2

615 384 383 Lake Rd W Collector 956 1

12 4

1700 40 2

616 385 384 Lake Rd W Collector 2018 1

12 4

1700 40 2

617 386 385 Lake Rd W Collector 508 1

12 4

1700 40 2

618 387 386 Lake Rd W Collector 290 1

12 4

1700 40 2

619 388 386 Driveway Local Roadway 542 1

12 4

900 20 2

620 629 628 US-20 Minor Arterial 1279 2

12 4

1900 35 23 621 629 630 US-20 Minor Arterial 747 2

12 4

1900 35 23 622 630 629 US-20 Minor Arterial 747 2

12 4

1900 35 23 623 630 631 US-20 Minor Arterial 1839 2

12 4

1900 35 23 624 631 630 US-20 Minor Arterial 1839 2

12 4

1900 35 23 625 631 948 US-20 Minor Arterial 2182 2

12 4

1900 35 22 Perry Nuclear Power Plant K-66 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 2

626 632 948 US-20 Minor Arterial 891 2

12 4

1900 35 22 627 632 8632 US-20 Minor Arterial 799 2

12 4

1900 35 22 Great Lakes Mall 628 633 629 Driveway Minor Arterial 459 2

12 4

1125 25 23 Great Lakes Mall 629 634 628 Driveway Minor Arterial 637 2

12 4

1125 25 23 Great Lakes Mall 630 635 633 Driveway Local Roadway 663 1

12 4

1125 25 23 Great Lakes Mall 631 635 634 Driveway Local Roadway 786 1

12 4

1125 25 23 632 636 631 Middlesex Rd Local Roadway 386 1

12 4

1125 25 22 633 637 638 SR 615 Minor Arterial 602 2

12 4

1900 35 21 634 637 667 SR 615 Collector 3036 1

12 4

1700 40 10 635 638 637 SR 615 Minor Arterial 602 1

12 4

1900 35 21 636 638 639 SR 615 Minor Arterial 1855 2

12 4

1900 35 21 637 639 638 SR 615 Minor Arterial 1855 2

12 4

1900 35 21 638 639 640 SR 615 Minor Arterial 1793 2

12 4

1900 35 21 639 640 639 SR 615 Minor Arterial 1793 2

12 4

1900 35 21 640 640 641 SR 615 Minor Arterial 288 2

12 4

1900 40 21 SR 2 on-ramp from 641 641 190 SR 615 Freeway Ramp 868 1

12 4

1700 40 21 642 641 640 SR 615 Minor Arterial 288 2

12 4

1900 35 21 643 641 642 SR 615 Minor Arterial 563 2

12 4

1900 40 21 SR 2 on-ramp from 644 642 189 SR 615 Collector 1426 1

12 4

1700 40 21 645 642 641 SR 615 Major Arterial 563 3

12 4

1900 40 21 646 642 643 SR 615 Minor Arterial 1028 2

12 4

1900 40 21 Perry Nuclear Power Plant Evacuation Time Estimate K-67 KLD Engineering, P.C.

Rev. 2

647 643 642 SR 615 Major Arterial 1028 3

12 4

1900 40 21 648 643 644 SR 615 Minor Arterial 590 2

12 4

1900 35 21 Exit Link 644 620 SR 615 Minor Arterial 2314 2

12 4

1900 35 21 649 644 643 SR 615 Minor Arterial 590 2

12 4

1900 40 21 650 645 606 SR 615 Minor Arterial 998 2

12 4

1900 35 23 651 645 620 SR 615 Minor Arterial 2087 2

12 4

1900 35 21 652 646 638 Munson Rd Local Roadway 508 1

12 4

1125 25 21 653 647 639 Fairfax Dr Local Roadway 778 1

12 4

1125 25 21 654 648 643 Tyler Blvd Collector 430 1

12 4

1575 35 21 655 649 648 Tyler Blvd Collector 481 1

12 4

1575 35 21 656 650 651 Twinbrook Rd Collector 834 1

12 4

1575 35 21 657 651 649 Tyler Blvd Collector 1394 1

12 4

1575 35 21 658 651 652 Tyler Blvd Collector 1617 1

12 4

1575 35 21 659 652 653 Tyler Blvd Minor Arterial 929 2

12 4

1900 35 21 660 653 654 Hopkins Rd Collector 379 1

12 4

1575 35 21 661 653 917 Munson Rd Collector 1429 1

12 4

1575 35 21 662 654 655 Hopkins Rd Collector 844 1

12 4

1575 35 24 663 655 656 Hopkins Rd Collector 1103 1

12 4

1575 35 24 664 656 598 Hopkins Rd Collector 835 1

12 4

1575 35 24 665 657 599 Hopkins Rd Collector 2014 1

12 4

1700 40 24 666 658 341 Hopkins Rd Collector 1934 1

12 4

1575 35 24 667 659 606 SR 615 Minor Arterial 2693 2

12 4

1900 45 23 668 393 392 SR 534 Local Roadway 153 1

12 4

600 15 8

669 393 394 SR 534 Collector 956 1

12 4

1575 35 8

670 394 32 SR 534 Collector 2596 1

12 4

1700 40 8

Perry Nuclear Power Plant Evacuation Time Estimate K-68 KLD Engineering, P.C.

Rev. 2

671 394 393 SR 534 Collector 956 1

12 4

1575 35 8

672 395 394 Commerce PI Collector 1045 1

12 4

1575 35 8

673 396 30 SR 534 Collector 1772 1

12 4

1700 45 8

674 396 34 SR 534 Collector 3004 1

12 4

1700 45 8

Sport Complex 675 397 396 Driveway Local Roadway 838 1

12 4

900 20 8

Sport Complex 676 398 397 Driveway Local Roadway 901 1

12 4

900 20 8

677 399 37 SR 534 Collector 2189 1

12 4

1700 60 8

678 400 42 SR 534 Collector 963 1

12 4

1700 40 18 679 401 403 CR 12 Collector 4009 1

12 4

1700 60 27 680 402 404 CR 12 Collector 650 1

12 4

1700 45 28 681 403 45 CR 12 Collector 6641 1

12 4

1700 60 27 682 404 405 CR 12 Collector 1615 1

12 4

1700 45 28 683 405 406 CR 12 Collector 561 1

12 4

1700 45 28 684 406 407 CR 12 Collector 1382 1

12 4

1700 45 28 685 407 408 CR 12 Collector 343 1

12 4

1700 45 28 686 408 409 CR 12 Collector 1394 1

12 4

1700 55 28 687 409 410 CR 12 Collector 405 1

12 4

1700 55 28 688 410 411 CR 12 Collector 2082 1

12 4

1700 60 28 689 411 412 CR 12 Collector 6743 1

12 4

1700 60 28 690 412 413 CR 12 Collector 1354 1

12 4

1700 60 29 691 413 414 CR 12 Collector 1003 1

12 4

1575 35 29 692 414 415 CR 12 Local Roadway 910 1

12 4

1125 25 29 693 415 416 CR 12 Local Roadway 1642 1

12 4

1125 25 29 694 415 418 SR 45 Local Roadway 1165 1

12 4

1125 25 29 Perry Nuclear Power Plant K-69 Evacuation Time Estimate KLD Engineering, P.C.

Rev. 2

695 416 8416 CR 12 Local Roadway 809 1

12 4

1125 25 29 696 417 415 SR 45 Local Roadway 1759 1

12 4

1125 25 29 697 418 8418 SR 45 Local Roadway 2589 1

12 4

1125 25 29 698 419 417 SR 45 Collector 2947 1

12 4

1700 60 29 699 420 419 SR 45 Collector 1224 1

12 4

1700 60 29 700 421 420 SR 45 Collector 3977 1

12 4

1700 60 29 701 422 421 SR 45 Collector 8976 1

12 4

1700 60 19 702 423 422 SR 45 Collector 2706 1

12 4

1700 60 19 703 424 423 SR 45 Collector 4464 1

12 4

1700 60 19 704 425 424 SR 45 Collector 8057 1

12 4

1700 60 19 705 426 425 SR 45 Collector 4382 1

12 4

1700 60 9

706 427 426 SR 45 Collector 1586 1

12 4

1700 40 9

707 428 427 SR 45 Collector 947 1

12 4

1575 35 9

708 428 429 SR 45 Collector 940 1

12 4

1575 35 9

709 428 431 SR 307 Collector 2302 1

12 4

1575 35 9

710 429 365 SR 45 Collector 2715 1

12 4

1575 35 9

711 429 428 SR 45 Collector 940 1

12 4

1575 35 9

712 430 428 SR 307 Collector 1289 1

12 4

1575 35 9

713 431 8431 SR 307 Collector 829 1

12 4

1575 35 9

714 432 363 SR 45 Collector 2827 1

12 4

1700 40 9

715 433 366 SR 45 Collector 6530 1

12 4

1700 55 9

716 434 437 SR 45 Collector 3445 1

12 4

1700 50 4

717 435 436 SR 531 Collector 997 1

12 4

1700 45 4

718 436 8436 SR 531 Collector 1063 1

12 4

1700 45 4

719 437 438 SR 45 Collector 3977 1

12 4

1700 50 4

Perry Nuclear Power Plant Evacuation Time Estimate K-70 KLD Engineering, P.C.

Rev. 2