12Q0108.50-R-002, Rev. 1, Seismic Walkdown Report in Response to the 50.54(f) Information Request Regarding Fukushima Near-Term Task Force Recommendation 2.3: Seismic for the LaSalle County Station, Unit 2, Part 12 of 16
ML12353A220
Person / Time
Site: LaSalle 
(NPF-018)
Issue date: 11/01/2012
From: Delaney M
Stevenson & Associates
To:
Exelon Generation Co, Office of Nuclear Reactor Regulation
References
RS-12-163 12Q0108.50-R-002, Rev 1
Download: ML12353A220 (26)


Text

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 1 of 9 Status: F N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-18 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4. Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment inthe area (e.g., ceiling tiles and lighting)?

Overhead light fixtures judged to be acceptable.

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Permanent scaffolds adequately restrained to gallery and support auxiliary steel.

Ladders acceptably chained to stair landing handrail.

D-63

1200108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 2 of 9 Status: [Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-18 Cart stored away from soft targets and judged to be acceptable.

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Seismic Walkdown Team: D. Carter & J. Griffith - 8/30/2012 Evaluated by:

Q,-Jý Ik David Carter Date:

10/17/2012 Ae James Griffith 10/17/2012 Photos D-64

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 3 of 9 Status: -Y' N U Area Walk-By Checklist (AWC) 1I D-65

12Q0108.50-R-002 Rev 1 Correspondence No.: RS-12-163 Sheet 4 of 9 Status: F N U Area Walk-By Checklist (AWC)

L D-66

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 5 of 9 Status: F N U Area Walk-By Checklist (AWC) 1-D-67

12QO108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 6 of 9 Status: F-1 N U Area Walk-By Checklist (AWC) 1-18 L

D-68

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 7 of 9 Status: F N

U Area Walk-By Checklist (AWC)

D-69

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 8 of 9 Status: F N U Area Walk-By Checklist (AWC) 1 1-Labaiie a-D-70

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 9 of 9 Status:

Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-18 D-71

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 1 of 4 Status: Fjj N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-19 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1.

Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?

2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

Minor lack of thread engagement at some anchors in the area judged to be acceptable.

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Overhead light fixtures judged to be acceptable.

Tube in contact with flexible conduit judged to be acceptable.

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Handrail rack stored acceptably.

D-72

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 2 of 4 Status: [Y7 N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-19

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Seismic Walkdown Team:

D. Carter & J. Griffith - 8/29/2012 D. Carter & J. Griffith - 9/4/2012 Evaluated by:

David Carter Date:

10/25/2012 James Griffith 10/25/2012 Photos D-73

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 3 of 4 Status: EVI, N U Area Walk-By Checklist (AWC) 1-19 D-74

12Q0108.50-R-002 Rev. 1 Correspondence No: RS-12-163 Sheet 4 of 4 Status: F N U Area Walk-By Checklist (AWC)

L D-75

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 1 of 8 Status: [-1 N U

Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-20 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1.

Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?

2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Valve 2E12-F049B handwheel contacts insulation on valve 2E12-F048B. Per

.Operations, handwheel does not rise during manual operation of valve. Judged to be of no concern.

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Ladder on floor not near soft targets judged to be acceptable.

Wooden 2x4 lodged between pipes above valve 2E12-F098B. No soft targets in vicinity below. Judged to be acceptable. See IR 1406885:

D-76

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 2 of 8 Status: rY N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-20

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Seismic Walkdown Team:

D. Carter & J. Griffith - 8/29/2012 D. Carter & J. Griffith - 8/30/2012 Evaluated by:

.Q-)4'Qk David Carter Date:

10/17/2012 4

James Griffith 10/17/2012 Photos L

D-77

12Q0108 50-R-002 Rev 1 Correspondence No.: RS-12-163 Sheet 3 of 8 Status: F N U Area Walk-By Checklist (AWC) 1-20 L

D-78

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 4 of 8 Status: LY7 N U Area Walk-By Checklist (AWC) 1 D-79

12Q0108 50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 5 of 8 Status: -Y' N U Area Walk-By Checklist (AWC) 1 L

D-80

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 6 of 8 Status: FYI N U Area Walk-By Checklist (AWC) 1-D-81

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 7 of 8 Status: r N U Area Walk-By Checklist (AWC)

I D-82

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 8 of 8 Status: F N U Area Walk-By Checklist (AWC) 1-LE D-83

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 1 of 5 Status: F-* N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-21 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.

Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
2.

Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?

3.

Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,

condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

4.

Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Overhead light fixtures judged to be acceptable.

5.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?

6.

Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?

7.

Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffold material observed near soft targets during walk-by. Scaffold material was subsequently relocated to an acceptable location and restrained to grating floor by Maintenance department.

D-84

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 2 of 5 Status: Y N U Area Walk-By Checklist (AWC)

Location (Bldg, Elev, Room/Area):

Area Walk-by 1-21

8.

Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?

Comments Seismic Walkdown Team: D. Carter & J. Griffith - 8/29/2012 Evaluated by:

  • ,JAJk David Carter Date:

10/17/2012 James Griffith 10/17/2012 D-85

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 3 of 5 Status:

I N U Area Walk-By Checklist (AWC) 1 D-86

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 4 of 5 Status: F N U Area Walk-By Checklist (AWC) 1-21 D-87

12Q0108.50-R-002 Rev. 1 Correspondence No.: RS-12-163 Sheet 5 of 5 Status:

Y N U Area Walk-By Checklist (AWC) 1-21 L

D-88