ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
U N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-227 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
91
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-227 Observed duct tape on fire pipe header support, although not good housekeeping practices, it is not a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 92
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-227 Area # AUX, 5, CAL-AB-227 8-7-12 212 Area # AUX, 5, CAL-AB-227 8-7-12 213 Area # AUX. 5. CAL-AB-227 8-7-12 214 Area # AUX. 5. CAL-AB-227 8-7-12 215 Area # AUX, 5, CAL-AB-227 8-7-12 216 Area # AUX, 5, CAL-AB-227 8-7-12 217 93 I
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-227 Area # AUX, 5, CAL-AB-227 8-7-12 218 Area #AUX, 5, CAL-AB-227 8-7-12 219 94
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: rT N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-228 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
The fixed end of HX12 seems to be a sliding type detail see photo. Based on a review of FSK-C-0084, section A l-A 1, the fixed end connection is considered fixed, therefore not a concern.
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes 95
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M-] N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 5, CAL-AB-228 Observed seismic-rated scaffold in area.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
(7* ~
gr-A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # AUX, 5, CAL-AB-228 8-7-12 188 Area WAUA, ), LAL-ALS-WS tJ-[-1Z 1UV 96
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area: AUX, 5, CAL-AB-228 Area #AUX, 5, CAL-AB-228 8-7-12 190 Area #AUX. 5. CAL-AB-228 8-7-12 191 Area #AUX, 5, CAL-AB-228 8-7-12 192 Area # AUX, 5, CAL-AB-228 8-7-12 193 97
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: AUX, 5, CAL-AB-228 xM Area # AUX, 5, CAL-AB-228 8-7-12 195 Area # AUX. 5. CAL-AB-228 8-7-12 196 Area # AUX, 5, CAL-AB-228 8-7-12 197 Area # AUX, 5, CAL-AB-228 8-7-12 198 98 I
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-512 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
Tubing support has dislodged from its wall and some tubing is no longer clipped into its supports, however the tubing is very light and flexible and judged to be adequately supported, therefore not a seismic concern.
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Cable tray and conduit supports are attached to building steel and judged acceptable.
Ducts in area are hung off braced frames and rods; no seismic concern noted.
- 4.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Masonry block walls, identified as A, B, C, ZZ and A 1 on drawing A-260, are safety-related and thus seismically rated per IE Bulletin 80-11.
An overhead light near AHU #11 is supported by clamping to an overhead duct. The clamp surface is slightly sloped such that clamps may fall (i.e. slip off) and light will potentially strike duct, and remain suspended from conduit, either way the light will not adversely affect the AHU. Judged not to be a seismic concern, but SWEs recommend correcting this condition.
- 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
99
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-512
- 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Observed an unrestrained step ladder but it is far from equipment and judged not a seismic concern.
A Tall ladder is restrained below its center of gravity, but equipment is protected by steel in the path of ladder movement and thus is not a seismic concern.
A smoke detector attachment was found on a Gaitronics Box, however it is not a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 100
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area : AUX, 70, CAL-AB-512 Area #AUX, 70, CAL-AB-512 8-17-12 041 101
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Area: AUX, 70, CAL-AB-512 Area 1;AUA, NU, UAL-Ab-01 Z U-1 (-1 Z U44 Area # AU, Area #AUX, 70, CAL-AB-512 8-17-12 045 Area #AUX, 70, CAL-AB-512 8-17-12 046 102
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-512 A----
.U Al IW A^f
^
B A"
- d'ltldJ
- l A
^~
Area # AUX, 70, CAL-AB-512 8-17-12 049 Area # AUX, 70, CAL-AB-512 8-17-12 050 103
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: AUX, 70, CAL-AB-512 Area #AUX, 70, CAL-AB-512 8-17-12 051 Area # AUX, 70, CAL-AB-512 8-17-12 052 104
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-524 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Need to determine if overhead lights are seismically adequate.
10/3/12 - Overhead lights were deemed not a credible seismic concern due to their lightweight and to typical construction practices. Also, they have been previously evaluated by CCNPP and found seismically acceptable.
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes 105
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-524 Found unrestrained ladders leaning against equipment and a square washer resting on a concrete pad, although not good housekeeping practices, judged not to be a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments
/)A!,
Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 106
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M* N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-524 Area # AUX, 70, CAL-AB-524 8-10-12 142 Area # AUX, 70, CAL-AB-524 8-10-12 143 Area #AUX, 70, CAL-AB-524 8-10-12 144 Area ;; Au
'U, UAL-Ab-OZ4 t5-1 U-1 2 140 107
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: AUX, 70, CAL-AB-524 i
no~v Area # AUX, 70, CAL-AB-524 8-10-12 147 108
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: FY N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-525 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1.
Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Tubing and flex conduit for valve 1CV3820 crosses the building separation, however it is judged to have adequate flexibility. A 2" pipe crosses the building gap, however the first support is vertical only and therefore also judged to have adequate flexibility. Judged not a seismic concern.
- 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
109
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-525 Observed portable ventilation unit with locked wheels and a portable tool cabinet with clamped wheels, both not a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
/ 9 A
A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 hoý -
V Area # AUX, 70, CAL-AB-525 8-9-12 126 110
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-525 Area # AUX, 70, CAL-AB-525 8-9-12 125 Area # AUX, 70, CAL-AB-525 8-9-12 130 L
Aran 22 Al IX
/[I
(:AI -AK-!VJM M-A-LJ 1-41 Area # AUX, 70, CAL-AB-525 8-9-12 132 Area F AUA, IV, UAL-Ab-OZO O-W-1 Z I133 111
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Area # AUX, 70, CAL-AB-525 8-9-12 134 Area # AUX, 70, CAL-AB-525 8-9-12 137 Area # AUX, 70, CAL-AB-525 8-9-12 138 112
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-525 Area # AUX, 70, CAL-AB-525 8-9-12 139 113
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M--* N U
Area Walk-By Checklist (AWC)
Area : AUX, 70, CAL-AB-525 114
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways. and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes Yes 115
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # AUX, 70, CAL-AB-ARF 8-13-12 002 Area # AUX, 70, CAL-AB-ARF 8-13-12 003 116
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Area # AUX, 70, CAL-AB-ARF 8-13-12 006 Area # AUX. 70. CAL-AB-ARF 8-13-12 005 Area #AUX, 70, CAL-AB-ARF 8-13-12 012 Area # AUX, 70, CAL-AB-ARF 8-13-12 013 117
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Area # AUX, 70, CAL-AB-ARF 8-13-12 015 Area # AUX, 70, CAL-AB-ARF 8-13-12 019 118
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Area # AUX, 70, CAL-AB-ARF 8-13-12 026 Area # AUX, 70, CAL-AB-ARF 8-13-12 029 119
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Area #AUX, 70, CAL-AB-ARF 8-13-12 030 Area # AUX, 70, CAL-AB-ARF 8-13-12 031 120
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : AUX, 70, CAL-AB-ARF Area # AUX, 70, CAL-AB-ARF 8-13-12 033 Area # AUX, 70, CAL-AB-ARF 8-13-12 035 121
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: r-Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB102 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
122
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB102 Observed scaffolding without a seismic tag near the starting air receiver, however 3 of the 4 scaffold legs are hooked to the floor grating, one corner is braced to Platform steel, one side is wedged to wall via pipe section, and the platform is braced. SWEs judged the platform may shift and bounce, but will not hit air receivers or associated tubing and devices and therefore not an adverse seismic condition. This condition is similar to Air Receivers 1A2.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
/7 A. Karavoussianis Date:
11/09/2012 z
C. Figliolini 11/09/2012 123
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB102 Area # DG, 45, CAL-DGB1-DB102 8-15-12 049 Area # DC
-mm I Area # DG, 45, CAL-DGB1-DB102 8-15-12 051 Area # DG, 45, CAL-DGB1-DB102 8-15-12 052 124
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F--
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB102 Area # DG, 45, CAL-DGB1-DB102 8-15-12 053 125
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F]
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB104 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes 126
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB104 Ops and maintenance equipment are staged in one comer without proper seismic restraint. The equipment will shift and fall to the floor but will not cause an adverse seismic condition and therefore judged acceptable.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 127
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB104 Area # DG, 45, CAL-DGB1-DB104 8-15-12 056 Area # DG, 45, CAL-DGBI-DB104 8-15-12 057 Area # DG, 45, CAL-DGB1-DB104 8-15-12 063 Area # DG, 45, CAL-DGB1-DB104 8-15-12 062 128
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB104 Area # DG, 45, CAL-DGB1-DB104 8-15-12 064 129
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: [-Y N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB106 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes Yes Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes 130
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGBI-DB106 Craft tools were found in certain areas indicating work is in progress, however this was judged not a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 Area # DG, 45, CAL-DGB1-DB106 8-15-12 067 131
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M---
N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 45, CAL-DGB1-DB106 Area # DG, 45, CAL-DGB1-DB106 8-15-12 069 132
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC) 45, CAL-DGB1-DB106 Area 1; UU, 40, t.;AL-UUb1 -UtJ1 UO 0-10-1 Z V f,1 Area # DG, 45, CAL-DGB1-DB106 8-15-12 074 133 I
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Area # DG, 45, CAL-DGB1-DB106 8-15-12 076 Area ;F uu, 4o, L;AL-UUt$1-Ut$1UO U-10-1Z UfO 134
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: F-].N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 74, CAL-DGB1-DB206 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1.
Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes Yes Yes Yes Yes Yes Yes 135
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M-I N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 74, CAL-DGB1-DB206
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
4 A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 Area # DG, 74, CAL-DGB1-DB206 8-15-12 078 Area # DG, 74, CAL-DGB1-DB206 8-15-12 080 136
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
T N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 77, CAL-DGB1-DB207 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concern for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
137
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 77, CAL-DGB1-DB207
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments
/7
/
Evaluated by:
/1
~~-'~--
A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # DG, 77, CAL-DGB1-DB207 8-15-12 082 Area # DG, 77, CAL-DGB1-DB207 8-15-12 083 138
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
I fru-finn fRi:ln IPlou PrI mlA
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y] N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 89, CAL-DGB1-DB307 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions
.that could cause flooding or spray in the area?
Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes Yes 140
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: E N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: DG, 89, CAL-DGB1-DB307 Observed a scaffold storage area far from equipment. Scaffold parts are stored in tube steel bin and within scaffold frame therefore both are judged adequate.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments
(~4~Zs~
Evaluated by:
A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # DG, 89, CAL-DGB1-DB307 8-15-12 101 Area # DG, 89, CAL-DGB1-DB307 8-15-12 102 141
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Blds. Elev. Room/Area):
Area: DG. 89. CAL-DGB1-DB307 Area # DG, 89, CAL-DGB1-DB307 8-15-12 103 142
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y W1 U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Intake, -7, CAL-ISPR-INT1 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes No 143
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y Fj U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Intake, -7, CAL-ISPR-INT1 Observed a scaffold staging area. The scaffolds part are stored in racks and far enough from equipment, judged not a seismic concern.
Tools and fall protection is being stored in ladder that is lying flat on the ground. This condition is not a seismic concern.
Potential seismic concerns:
Portable flow monitors are close to pump pit, so that they may fall in and possibly strike small bore piping in pit. Refer to SWC & CR-2012-009091 for 1PUMPSW11 & IPUMPSW12 CR-2012-008387 UNO There is a scaffold that may shift and strike JB 1JO25B.
Observed a ladder in close proximity to tube for 1-PT5221.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments A/
/
1/.
-~--
Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 Area # Intake, 8-7, CAL-ISPR-INTI 8-16-12 194 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 195 144
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
YUR U Area Walk-By Checklist (AWC)
I rwvafinn 1Rlrin I9:1xhu PrumlAra
-7, CAL-ISPR-INT1 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 197 Area iw Inmae, 0- f, UAL-I5rI(-IN I IU1 (jT-1 Z 9b Aw I
3 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 202 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 203 145
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y E U Area Walk-By Checklist (AWC)
Vrea):
Area: Intake, -7, CAL-ISPR-INT1 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 204 Area a IntaKe, U-1, UAL-ISIR-IN 11 U-15-12 205 146
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y [-R] U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area: Intake, -7, CAL-ISPR-INT1 Area a IntaKe, a-7, UAL-IbPX-IN 11 5-16-12 20U Area # IntaKe, U-7, CAL-ISPR-INT1 U-16-12 207 147
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Y E U
Area Walk-By Checklist (AWC)
Area: Intake, -7, CAL-ISPR-INT1 Area # Intake, 8-7, CAL-ISPR-INT1 8-16-12 209 A~rea
- inTaKe, O-f, UL-IRW(-Ir 11 0-10-1Z /_?
148
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
Y w U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Intake, -7, CAL-ISPR-INT1 Area # Intake, 8-7, CAL-ISPR-lI1 Area; winTaKe, 0-f, U.SL-IZWK-IN I 1 6-10-1Z Z1 149
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status:
YEW] u Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Intake, -7, CAL-ISPR-INT1 Area P inzaKe, t$-t, L.AL-Itil--IN I 1 U-W-iU 21 150
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: TURB, 12, CAL-AFWPR-603 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially Yes adverse seismic conditions (if visible without necessarily opening cabinets)?
- 2.
Does anchorage of equipment in the area appear to be free of significant Yes degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and Yes HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4.
Does it appear that the area is free of potentially adverse seismic spatial Yes interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Need to determine if lights are seismically adequate.
10/3/12 - Overhead lights were deemed not a credible seismic concern due to their lightweight and to typical construction practices. Also, they have been previously evaluated by CCNPP and found seismically acceptable.
- 5.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause flooding or spray in the area?
The overhead threaded fire piping is judged to be adequately supported and not a concem for spray or flooding.
- 6.
Does it appear that the area is free of potentially adverse seismic interactions Yes that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions Yes associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
151
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: TURB, 12, CAL-AFWPR-603
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
//..A is.
-'i 4~44-h A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # TURB, 12, CAL-AFWPR-603 8-10-12 032 Area # TURB, 12, CAL-AFWPR-603 8-10-12 033 152
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: FT N U Area Walk-By Checklist (AWC)
I n*.tinn MRein Flov RPnnmlAra Area: TURB, 12, CAL-AFWPR-603 Area # TURB, 12, CAL-AFWPR-603 8-10-12 034 153
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-21FOSTBLDG Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes Yes Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
154
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M-I N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-21FOSTBLDG Observed a wrench left on a tank base, but it is not a concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments A.
&~
Evaluated by:
A. Karavoussianis Date:
11/09/2012 (C.
Figliolini 11/09/2012 155
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: FVY N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-21FOSTBLDG Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 077 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 078 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 079 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 080 156
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/A,rea): Area : Yard, 45, CAL-21FOSTBLDG Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 081
. CAL-21FOSTBLDG 8-13-12 082 157
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC) n (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-21FOSTBLDG Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 084 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 083 158
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Elev, Room/Area):
Area: Yard, 45, CAL-21FOSTBLDG Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 085 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 159
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Area: Yard, 45, CAL-21FOST A~rs2 3z Yom a- !
(:ni jT_'I i
i KNi4I i(. m4
,4U timm llg!
2YOMf A.% (:11, _711-f IN I 141 I It.; X4-1T4-17 (MU Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 090 Area # Yard, 45, CAL-21FOSTBLDG 8-13-12 091 160
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: Mi N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-TKFROOM Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Observed corrosion on a conduit support base angle, however it is judged not to be a seismic concern.
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
Yes Yes
- 4.
Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Observed a Victaulic coupling, however judged not to be a seismic concern.
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
Yes Yes
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes Yes 161
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : Yard, 45, CAL-TKFROOM Observed a Hazmat storage area with equipment that is not tied off, however judged not to be a seismic concern.
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments Evaluated by:
/
A A. Karavoussianis C. Figliolini Date:
11/09/2012 11/09/2012 Area # Yard, 45, CAL-TKFROOM 8-15-12 003 Area # Yard, 45, CAL-TKFROOM 8-15-12 004 162
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI-N U
Area Walk-By Checklist (AWC)
Area # Yard, 45, CAL-TKFROOM 8-15-12 007 Area # Yard, 45, CAL-TKFROOM 8-15-12 006 163
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-TKFROOM Area # Yard, 45, CAL-TKFROOM 8-15-12 008 Area # Yard, 45, CAL-TKFROOM 8-15-12 010 Area # Yard, 45, CAL-TKFROOM 8-15-12 011 Area # Yard, 45, CAL-TKFROOM 8-15-12 012 164
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
I nrofinn (RIRln IPlow Pnm/Ar=mo" Art=m
- Vorri AS (f'AI _TLICPPnrR It J
.4-Area # Yard, 45, CAL-TKFROOM 8-15-12 014 Area v Yara, 4b, UAL-IKP-KOUM U-15-12 U13 165
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N U
Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-TKFROOM Area # Yard, 45, CAL-TKFROOM 8-15-12 016 166
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Area: Yard, 45, CAL-TKFROOM 167
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-YARD-OCA Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.
Additional space is provided at the end of this checklist for documenting other comments.
- 1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
Yes
- 2.
Does anchorage of equipment in the area appear to be free of significant degraded conditions?
Yes
- 3.
Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g.,
condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?
- 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
Yes Yes Yes
- 5.
Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?
- 6.
Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?
Yes
- 7.
Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?
Yes 168
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: MI N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-YARD-OCA
- 8.
Have you looked for and found no other seismic conditions that could Yes adversely affect the safety functions of the equipment in the area?
Comments
/7
/
/7.
v~~-
Evaluated by:
A. Karavoussianis Date:
11/09/2012 C. Figliolini 11/09/2012 Area # Yard, 45, CAL-YARD-OCA 8-13-12 103 169
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area: Yard, 45, CAL-YARD-OCA Area # Yard, 45, CAL-YARD-OCA 8-13-12 104 Area # Yard, 45, CAL-YARD-OCA 8-13-12 105 Area # Yard, 45, CAL-YARD-OCA 8-13-12 106 170
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N U Area Walk-By Checklist (AWC)
Area # Yard, 45, CAL-YARD-OCA 8-13-12 107 Area # Yard, 45, CAL-YARD-OCA 8-13-12 109 Area # Yard, 45, CAL-YARD-OCA 8-13-12 110 171
ATTACHMENT 4 AREA WALK-BY CHECKLIST Status: M N
U Area Walk-By Checklist (AWC)
Location (Bldg, Elev, Room/Area):
Area : Yard, 45, CAL-YARD-OCA
,or 1
Area # Yard, 45, CAL-YARD-OCA 8-13-12 111 172
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW E
Plan for Future Seismic Walkdown of Inaccessible Equipment As shown in the SWEL for Calvert Cliffs Unit I in Attachment 2, several items have been deferred until the next refueling outage (RFO).
Table E-1 summarizes the reasons each item is inaccessible during normal plant operation, and notes the planned Seismic Walkdown date. There are also Area Walk-Bys associated with these items.
All items will be walked down during the next RFO, scheduled for completion on March 11, 2014. An updated submittal report will be provided on June 15, 2014.
Table 0-1: Summary of Deferred Equipment SWE L
Reason for Item Component ID Description Location Inaccessibility 5
0HXHVACCRE 12 12 CONT ROOM CLG EVAP CAL-AB-512 d.
19 ICV3938 STM GEN 11 ATMOS DUMP VLV CAL-AB-428 b.
20 ICV39380P 11 MS S/G ADV OPERATOR CAL-AB-428 b.
21 ICV3939 STM GEN 12 ATMOS DUMP CAL-AB-428 b.
VALVE 26 1CV4150 CNTMT SPRAY HDR 11 ISOL CAL-CTMT-230 a.
VALVE 27 1CV4151 CNTMT SPRAY HDR 12
]SOL CAL-CTMT-230 a.
VALVE CAL-CTMT-34 1ERV402 PZR PWR OP RV 230E a.
230E 39 IFANHVACCTCLRI 1 CONTAINMENT COOLER 11 FAN CAL-AB-ARF a.
40 1FANHVACCTCLRI4 CONTAINMENT COOLE 14 FAN CAL-AB-ARF a.
114 IFL1999 11 SPENT FUEL POOL FILTER CAL-AB-320 c.
51 1M1447 CR POST LOCI FILTER FAN 11 CAL-AB-512 d.
89 IPUMPSW1 1 11 SALT WATER PUMP CAL-ISPR-INTI e.
90 IPUMPSWI2 12 SALT WATER PUMP CAL-ISPR-INT1 e.
Inaccessibility code:
- a.
Inspection requires entry into Primary Containment. (Walkdown performed at full power.)
- b.
Inspection requires access to environmental enclosure.
- c.
Inspection requires access to locked high radiation area.
- d.
Inspection requires access to air handling unit.
- e.
Inspection requires entry into confined space. (Inspection of non-anchorage items performed.)
Table E-2 includes the list of equipment items that require supplemental internal inspections because they were not opened during the walkdowns. Cabinets that have been identified as requiring these supplemental internal inspections are those with doors or panels with latches or thumbscrews and can be readily opened during normal maintenance activities. Also provided for each cabinet is a proposed schedule for performing these internal inspections.
1
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW The Seismic Walkdown Checklists (SWC) for the 2 components identified in Table E-2 that can be opened for internal inspections will be revised at the time of the supplemental walkdown to indicate the results of these internal inspections.
Table 0-2: Summary of Equipment Subject to Supplemental Internal Inspection Planned SWE Planned Pdated L
Walkdown Updated item Component ID Description Location
/ Walk-By Submittal Date Report Date 9
lBKRI52-1110(N°le 1) HIGH PRESSURE SAFETY CAL-AB-317 INJECTION PUMP 13 48 1L1561 lA COND STORAGE TANK 12 CAL-AB-430 Notes:
- 1) Additional internal anchorage also needs verification during this supplementary walkdown.
In addition there are eleven (11) equipment items that were not opened during the walkdowns and do not have maintenance scheduled. To remove these from service an entire safety related bus must be de-energized, which puts the plant at significant risk. It is unsafe to open these while they are in service.
Table 0-3: Summary of Inaccessible Equipment SWEL Component ID Description Location Impact Code Item #
11 IBUSIBOIB 480V BUS lIB CAL-AB-317 a.
12 IBUSID01 125VDC BUS I 1 CAL-AB-306 b.
CAL-DGBl1-13 1CHGRI6 125V DC BATT CHGR 16 c.
13 DB104 61 1NB 102 CNTMT COOL FAN I
CAL-AB-429 c.
CONTROLLER 70 PNL B
DG LOCAL CONTROL CAL-AB-421 a.
PANEL 71 IPNL1C62C 11B DG LOCAL CONTROL CAL-AB-421 b.
PANEL 73 IPNLID1I 125VDC PNL DCI1 IDlI CAL-AB-306 a.
93 IRYI50G/T14A 480V SERV XFMR U-440-14A CAL-AB-430 b.
94 IRYI50G/TI4B 480V SERV XFMR U-440-14B CAL-AB-430 b.
95 iRYiY03A/64/B13 1Y03 INVERTER CAL-AB-306 c.
111 IXU-440-1 IA 480V XFMR U-440-1 IA CAL-AB-317 a.
2
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW Table 0-3: Summary of Inaccessible Equipment SWEL Component ID Description Location Impact Code Item #I Impact Code:
- a.
Internal anchorage is inaccessible, condition and compliance with licensing basis cannot be established.
Cabinet is inaccessible for internal inspection. SWC questions 2, 3, 4, 5 and I I cannot be assessed and have been answered., "No".
- b.
Internal anchorage is inaccessible and condition cannot be established (not a configuration verification item). Cabinet is inaccessible for internal inspection. SWC questions 2, 3, 4 and 11 cannot be assessed and have been answered, "No".
- c.
Cabinet is inaccessible for supplemental internal inspection. SWC question II cannot be assessed and has been answered, "No".
3
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW F
Peer Review Checklists Peer Review Checklist for SWEL - Calvert Cliffs Nuclear Power Plant Unit I Instructions for Completing Checklist This peer review checklist may be used to document the review of the Seismic Walkdown Equipment List (SWEL) in accordance with Section 6: Peer Review. The space below each question in this checklist should be used to describe any findings identified during the peer review process and how the SWEL may have changed to address those findings. Additional space is provided at the end of this checklist for documenting other comments.
- 1. Were the five safety functions adequately represented in the SWEL I selection?
YZ ND
- 2.
Does SWEL I include an appropriate representation of items having the following sample selection attributes:
- a.
Various types of systems?
YZ ND
- b.
Major new and replacement equipment?
YZ NEI
- c.
Various types of equipment?
YZ NEI 1
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW Peer Review Checklist for SWEL - Calvert Cliffs Nuclear Power Plant Unit 1
- d.
Various environments?
YN N-I
- e.
Equipment enhanced based on the findings of the IPEEE (or equivalent) program?
Y[9 NO
- f.
Were risk insights considered in the development of SWEL I?
YZ NO
- 3. For SWEL 2:
- a.
Were spent fuel pool related items considered, and if applicable included in YZ N-SWEL 2?
- b.
Was an appropriate justification documented for spent fuel pool related items not YZ NF included in SWEL 2?
2
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW Peer Review Checklist for SWEL - Calvert Cliffs Nuclear Power Plant Unit 1
- 4. Provide any other comments related to the peer review of the SWELs.
- 5. Have all peer review comments been adequately addressed in the final SWEL?
YE N[-]
Peer Reviewer #1:
Date: 07/30/2012 O
jor Date: 08/02/2012 Peer Reviewer #2:
3
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW G
SWEL 2 Development Screen 4 - SFP Rapid Drain Down The process to identify SSCs that could cause rapid drain-down of the SFP is identified in Screen #4 of the Seismic Walkdown Guidance [Reference I].
Per the Guidance, rapid drain-down is defined as lowering the water level to the top of the fuel assemblies within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after an earthquake.
Determination of the potential for rapid drain-down includes the following assessment:
Determine whether there are SFP penetrations below about 10 ft above the top of the fuel assemblies.
The top of the fuel assemblies are at elevation 44'-2.5".
Therefore the SFP will be checked for penetrations below elevation 54'-2.5". A review of the SFP liner drawings [References 16 - 18] indicates pipe embedments exist for SFP Cooling at elevation 65'-1 I". Also, penetrations for the SFP skimmers are located at elevation 63'-8" [References 24 - 26]. These penetrations are located above the elevation range of concern and will not be considered.
The only penetrations in the range of concern are the fuel transfer tubes at elevation 35'-6" [References 16 & 19]. The transfer tubes are isolated on the SFP side with 36-inch gate valves. The valves are seismically installed and are designed not to fail during a seismic event. The isolation valves are locked shut in Modes I - 4 per Reference 27. The transfer tubes are sealed on the Refueling Pool side with blind flanges. The blind flanges are leak tested per Reference 28. Based on the transfer tube assembly's seismic capacity and the fact that it is inaccessible for a walkdown, the transfer tubes will be eliminated from the scope of SWEL 2. The transfer tubes have component names 1PEN42 and 2PEN42, which are considered part of the Containment Structure (System 059).
Deep suction lines exist in the SFP that were originally designed to drain the pool for maintenance or decommissioning. The two lines are part of the normal SFP Cooling System; however, the deep lines are isolated with valves that are locked shut. Goose neck siphon breaks are installed on the deep lines that are designed to prevent inadvertent draining of the pool. The use of this line-up is procedurally controlled by Reference 28. The lines are open ended at elevation 34'-6" however they penetrate the pool at elevation 65'-11", which is out of the range of concern.
SFP Cooling return lines also exist that have a similar configuration to the deep suction lines. These 2 lines are open ended at elevation 30'-6" and penetrate the pool at elevation 65'- 11 ", which is out of the range of concern. Siphon breaks exist on these lines to prevent inadvertent draining of the pool.
The SFP is designed to preclude the loss of structural integrity. If a leak from the SFP were to occur, the capabilities for controlling the leak are as follows:
Makeup water can be supplied indefinitely to the SFP at a rate of at least 150 gpm. It can usually be supplied at a greater rate for a period of many days, but this depends upon plant conditions.
Abnormal Operating Procedures (AOP) and Severe Accident Management Guidelines address loss of and restoration of SFP level.
A 3/16-inch stainless steel liner is installed on the inside of the SFP for leak tightness. All of the liner plate welds have leak-test channels welded to the outer side. The channels are grouped into 10 zones, each with its own detector pipe to localize leaks in the liner seams [Reference 30].
1
ATTACHMENT 5 INACCESSIBLE EQUIPMENT AND PEER REVIEW The Tech Spec LCO [Reference 23] states the SFP water level shall be > 21.5 ft over the top of the irradiated fuel assemblies seated in the storage racks, and > 19.8 ft over the top of fuel assemblies seated on rack spacers in the storage racks for reconstitution activities.
This LCO is applicable during movement of irradiated fuel assemblies in the SFP.
2
ATTACHMENT (6)
REGULATORY COMMITMENTS CONTAINED IN THIS CORRESPONDENCE
ATTACHMENT 6 REGULATORY COMMITMENTS CONTAINED IN THIS CORRESPONDENCE The following table identifies actions committed to in this document by Calvert Cliffs Unit 1. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
REGULATORY COMMITMENT DUE DATE Perform followup of internal inspection of electrical By the end of the Calvert Cliffs Unit I cabinets as listed in Table E-I of Attachment 4.
refueling outage in Spring 2014 Submit an updated seismic walkdown report.
June 15, 2014