Dr. Manuel Lagunas-Solar Associate Director, Radioisotope Sciences & Developments NRC/UC Davis Public Meeting December 18, 2012

Agenda Introduction - Dr. Barry M. Klein, Director MNRC Presentation - Dr. Manuel Lagunas-Solar

Background

- General UC Davis MNRC Plan in the Nuclear Sciences

- Method, Facility, and Procedures for Production of Iodine-125 (60 d)

Accident Analysis (SAR Chapter 13)

On-Site Target Transfer

- Procedure

- Portable Radiation Shield

- Accident Analysis Conclusions NRC Public Meeting - Dec. 18, 2012 2

General UC Davis/MNRC Plan in the Nuclear Sciences Current funded efforts by DOE and NNSA (research & education)

Potential NSF funded Science & Technology Center (CBiNS) (Under Final Review)

Development of Radioisotope Science Facility (RSF) at MNRC (In Progress)

- Radioactive Material License from CDPH-Radiological Health Branch (In Progress)

- Part 50 NRC License Amendment Application for R-130 (Under Preparation)

- Large-scale production of Iodine-125 (New Batch Process)

- Application, SAR, Environmental Report (In Progress)

- Revision of MNRC Tech Specs (In Progress)

NRC Public Meeting - Dec. 18, 2012 3

Method: Batch production of I-125 using the 124Xe (n,)125Xe (17.1 h) 125I (60 d) thermal neutron reaction with enriched Xe-124 gas targets.

Production method uses an Al 6061 T6 thick wall (1/8-in. each) double-contained pressurized (200 psi) Xe-124 gas target for < 14 h irradiation at the existing central irradiation facility at the 2.0 MW TRIGA at UC Davis MNRC.

The irradiated target with ~ 4,235 Ci of Xe-125 is then transferred to an adjacent building (see below) for processing.

Facility: A new Radioisotope Science Facility (RSF) adjacent to MNRC Reactor will house a dedicated laboratory and equipment to process irradiated Xe-124 targets for the production and distribution of I-125. An adjacent QA/QC laboratory will support the I-125 production effort. Other RSF laboratory facilities will be used for R&D and educational activities, pursuant to CDPH Agreement State license.

Procedures: Target handling/transfer to RSF for processing and back to Reactor building for a new irradiation cycle uses a Portable Pb Radiation Shield, while Xe-124 recycling and I-125 radiochemistry use an entirely robotic operation in well-shielded, vented, filtered and monitored newly-designed radioisotope boxes. The processing of Xe-124 targets is to take place in a dedicated I-125 laboratory. The whole procedure involves a 16-step process each of which has been analyzed for potential accident event scenarios (AES).

Accident Analysis: The 16-step process was analyzed and evaluated for credible accident scenarios and Maximum Hypothetical Accidents (MHA) using frequency (including quantitative probabilities) and consequence rationales and countermeasures or mitigating factors. MHAs (assumed worst-case scenarios) were identified and analyzed and used as non-credible references. It is estimated that 45 (once per week) to 90 (twice per week) I-125 batches may be produced annually. (1) US Patent Pending NRC Public Meeting - Dec. 18, 2012 4

NRC Public Meeting - Dec. 18, 2012 5

Reusable (<12 runs), pressurized, double containment, enriched Xe-124 gas target1 (1) US Patent Disclosure

NRC Public Meeting - Dec. 18, 2012 6

1 10 100 1000 10000 0

50 100 150 200 250 300 Radioactivities (Ci)

Xe-124 Load Pressure (psig)

Neutron Irradiation Time = 14 h Thermal Flux CIF= 1.5x1013 n/cm2s Production of Iodine-125: Radioactivity vs. Xe-124 Load Pressure I-125 yield produced (lost) in target during irradiation Xe-125 yield at EOB (with decay during irradiation)

I-125 yield after 5-d Xe-125 Xe-125 remaining in Xe gases after 5-d Maximum Intended Production Levels Production Information I-125 = ~ 47 Ci/batch at End-of-Processing (EOP) (in 0.1N NaOH);

Xe-125 = ~ 4,235 Ci at End-of-Bombardment (EOB);

I-125 lost in target (Xe-125 decay during 14-h irradiation) = ~ 16 Ci; Xe-125 after 5-d decay = ~ 32 Ci (0.6%).

NRC Public Meeting - Dec. 18, 2012 7

The overall space available for RSF is

~ 13, 400 ft2.

The east side of the facility has 6 800-1,000 ft2 laboratory spaces and 5 200-300 ft2 support rooms.

The west side of the facility has a class room, 9 offices, and 5 additional rooms that will be utilized as support shops (electronics, machining, etc.) and storage areas.

NRC Public Meeting - Dec. 18, 2012 8

Target In/Out NRC Public Meeting - Dec. 18, 2012 9

NRC Public Meeting - Dec. 18, 2012 10

Table 1. Iodine -125 Production Process Flow Chart (Hazard Analysis & Critical Control Points)

Step (HACCP)

Time (day)

Location Process Phase Description 1

-1 RSF Xe-124 target testing. Radiochemistry system preparation and testing (6-8 h) 2

-1 MNRC Xe-124 target transport (from RSF) and loading in Reactor (1 h) 3 1-2 MNRC Xe-124 target irradiation to produce Xe-125 (< 14 h) 4 1-2 MNRC Xe-124/Xe-125 target removal from reactor & loading to Pb transport shield (0.5 h) 5 1-2 MNRC &

RSF Xe-124/Xe-125 target/portable PB radiation shield transport to RSF (0.3 h) and placement into Box 1 processing system (0.2 h) 6 1-2 RSF Xe-124/Xe-125 target connection to Box 1 processing system and connectivity assessment (Robotic operation) (< 0.1 h) 7 1-2 RSF Robotic-controlled cryogenic transfer of Xe-125/Xe-124 gases into Decay/Storage Vessel (< 0.1 h) 8 3-5 RSF Decay of Xe-125 to I-125 in Decay/Storage Vessel (tmax ~ 3.5 d).

9 3-5 RSF Recovery of Xe-124 gas (with Xe-125) to new target/shield system for a subsequent irradiation (< 0.1 h) 10 3-5 RSF Remote-control automatic removal (recovery) of I-125 and transfer into Box 2 processing system (< 0.1 h) 11 3-5 RSF Formulation of I-125 into final aqueous solution and fractionation in Box 2 processing system (< 1 h) 12 3-5 RSF QA/QC and final certification of I-125 solution for transfer to licensed users (~ 2 h) 13 4-6 RSF Release of authorized shipments to licensed users under DOT regulations (MNRC RSO supervision) (1 h) 14 4-6 RSF Finalize documentation of I-125 batch (0.5 h) 15 4-6 RSF Preparation of I-125 processing system (Box 1 and Box 2) for subsequent production (include waste management) (4 h) 16 4-6 RSF Secure storage of new Xe-124 target/shield system in Box 1 for next production run (1 h).

NRC Public Meeting - Dec. 18, 2012 11

Reactor Production of Iodine-125 from Enriched Xenon-124 Targets ACCIDENT ANALYSIS REPORT (AAR)byMNRC AARIC INTERNAL COMMITTEE Gerry Westcott, EH&S (gdwestcot@ucdavis.edu)

Jeff Ching, EH&S (jkching@ucdavis.edu)

Burton Mehciz, MNRC (bjmehciz@ucdavis.edu)

Tim Essert, MNRC (tkessert@ucdavis.edu)

Charles W. Dresser (Graduate Student) (dressercharles@gmail.com)

Walter (Guy) Steingass, MNRC (wgsteingass@ucdavis.edu)

Wesley D. Fry, MNRC (wesfry@ucdavis.edu)

Manuel Lagunas-Solar, MNRC (mlagunassolar@ucdavis.edu)

OUTSIDE CONSULTANT Dr. Steve Reese, Oregon State University (steve.reese@oregonstate.edu)

CDPH-RADIOLOGICAL HEALTH BRANCH LIAISON James Thomas, CDPH - Radiological Health Branch (James.Thomas@cdph.ca.gov)

NRC Public Meeting - Dec. 18, 2012 12

Reactor Production of Iodine-125 from Enriched Xenon-124 Targets Table 2. Criteria and Rationale for Accident Analysis (Based upon a Single Batch Production Mode)

Accident Event (Stages)

Defines a type of failure in the I-125 production system involving an accidental release (loss of containment) of radioactivity (mostly Xe-125; I-125 and others) in the following stages (1) System Pre-Validation; (2) Target Irradiation; (3) Target Transfer; (4) Processing and (5) Distribution Frequency (Probability)

Defines how often an accident event is anticipated (i.e. very Unlikely (1/10,000; 0.01%); remote (1/1,000; 0.1%); likely [occasional] (1/100; 1%); and frequent (1/10; 10%).

Consequences Defines the overall effects on worker, public, and environmental health as catastrophic (non-reversible), critical; high; medium; minor; and none.

Risk Assessment Defines overall risk level as high, medium and low based upon frequency, countermeasures, and consequence factors. Includes an accident credibility assessment as credible and non-credible (Maximum Hypothetical Accident, MHA) for every type of accident event.

Countermeasures Indicates availability of accident controlling (mitigating) factors associated with design & engineering, material specifications; and operation features including administrative controls to react to and/or to control an accidental event. Includes MNRC Emergency Plan.

NRC Public Meeting - Dec. 18, 2012 13

Accident Analysis Process Overview Description of Accident Event Scenario Accident Stage Parameters

  • Hazards
  • Material at Risk
  • Potential Causes
  • Detection Capabilities Determination of Frequency and Assumed Probability Countermeasures (Mitigating Factors)
  • Design & Engineering
  • Materials
  • Procedures (Operational Restrictions)
  • Administrative Controls Analysis of Consequences Risk Assessment and Credibility AARIC Conclusions NRC Public Meeting - Dec. 18, 2012 14

AARIC Conclusions Summary of AARIC Analyses Accident Scenario Frequency Consequence Risk Assessment AARIC Voting

1. Target/System Testing Very unlikely Low Low/Credible Unanimous
2. Target Transport/Loading Very unlikely Low Low/Credible Unanimous
3. Reactor Target Irradiation Very unlikely Critical Low/Credible Unanimous
4. Target Removal/Loading Very unlikely Low Low/Credible Unanimous
5. Target Transfer Reactor to RSF Remote Critical Low/Non-Credible Unanimous
6. Target System Connection Very Unlikely High Low/Credible Unanimous
7. Target Processing Remote Low Low/Credible Unanimous
8. Xe-125/I-125 Decay Period Very unlikely Low Low/Credible Unanimous
9. Xe-124 Recovery Remote Low Low/Credible Unanimous
10. I-125 Recovery Transfer to Box 2 Remote Low Low/Credible Unanimous
11. I-125 Product Formulation-Box2 Very unlikely Low Low/Credible Unanimous
12. QA/QC Certification Very unlikely Low Low/Credible Unanimous
13. Release for Distribution Very unlikely None Low/Non-Credible Unanimous
14. Final Documentation N/A N/A N/A Unanimous
15. System Prep Next Run Very unlikely Low Low/Non-Credible Unanimous
16. Secure Storage Target/Pb Shield Very unlikely Low Low/Non-Credible Unanimous NRC Public Meeting - Dec. 18, 2012 15

NRC Public Meeting - Dec. 18, 2012 16

NRC Public Meeting - Dec. 18, 2012 17

Target Transfer Information*Only between MNRC Reactor and MNRC RSF (RT)*Target always inside Portable Pb Radiation Shield *RSF-to-Reactor (Step 2) -Cold Target/Low Radiation*Reactor-to-RSF (Step 5) -Hot Target/High Radiation*MNRC wide transfer announcement*Secured corridor (controlled area) fenced and concrete barriers (i.e. K-rails)*Radiation monitoring during entire process*Distance: 420 ft. (128 m) maximum*Estimated transit time: 2-3 min at 2-3 miles/h (walking speed)*Estimated transfer process time: 10-15 min *Certified forklift operator with back up (2 person)*Receiving area ready and secured*Documented procedure including change in supervision from Reactor Operation to Radioisotope Staff (chain of custody) or vice versa.Target Transfer NRC Public Meeting - Dec. 18, 2012 18

Accident Event Scenario # 5 Day 1 or 2 MNRC & RSF Xe-124 target/shield transport to RSF (0.3 h) and placement into Box 1 Processing system (0.2 h)

Accident Stage Parameters Hazards

Accidental radiation exposure to personnel and members of the public from a Xe-125 release

(Secondary Effect). Radiation exposure to personnel and members of the public from I-125 produced in

the decay of Xe-125

(Secondary Effect) Biological uptake of I-125 by personnel or members of the public

(Secondary Effect) I-125 contamination in uncontrolled areas Material at Risk

Up to 4,235 Ci Xe-125 Potential Causes of the Event

Rupture of Pb shield exposing the irradiated target

Release of Xe-125 due to target containment failure Detection Capabilities

Hand-held radiation meters

Airborne radioactivity measurement system (Required for accident assessment)

Countermeasures Design &

Engineering:

Double encapsulation of Xe-124 inside the target during transport

Two (2) welded SS bellow valves with metallic seals

An additional cap over the target gas access point provides further access restriction to the target contents

Elastomer seals on all Pb shield openings for additional leak mitigation

Radiation shielding remains effective if target containment is compromised as long as Xe-125 is contained inside the shield cavity

SS cladding - 0.25 in. surrounding Pb shield

Pb shield weight (~ 5,000) lb, low center of gravity (~24-in above base), and Pb thickness (>7.5-in thickness >18-in outside diameter) make toppling the shield difficult

Short distance between Reactor and RSF buildings requires short transport time (< 30 min)

Fenced and secured transport corridor between Reactor and RSF buildings keeps public > 3 m away from the target Operational Restrictions:

All process steps will be conducted by properly certified/trained personnel under close, direct supervision

The fenced corridor between the Reactor and RSF buildings will be secured and controlled by MNRC personnel before the transfer takes place

Box 1 at the RSF building will be prepared and ready to receive the target prior to its transport to the RSF building

The transfer between buildings will not begin until the target/Pb shield is properly secured to the fork-lift at MNRC staging area

The transfer operation will be conducted using well-known, documented, and practiced procedures with the use of all prescribed countermeasures, controls, and oversight

The Reactor Operations staff (2 supervisory level personnel) will release the target/Pb shield to the supervisory level Radioisotope Staff member in the MNRC staging area only with the approval of the MNRC RSO or trained representative

The RSO or his designee will approve transfer only after all health physics operational guidelines are met and the transfer documentation is completed

A certified fork-lift operator accompanied by the supervisory level Radioisotope Staff member will drive the loaded fork-lift at a walking speed to the RSF building using the secured corridor

When the target/Pb shield reaches the RSF building, it will be placed inside Box 1 AARIC Final Vote Frequency:

Remote Consequence:

Critical Risk Assessment:

Low Credibility:

Non-Credible Conclusions AARIC Recommendation: Potentially catastrophic consequences, but remote likelihood with many of the associated methods of failure considered as non-credible (such as multiple, simultaneous valve failure or complete, sudden loss of radiation shielding). Design and engineering and operational restrictions are sufficient to mitigate potential risks and operate safely and reliably.

NRC Public Meeting - Dec. 18, 2012 19

Maximum TEDE and CEDE Radiation Dose Estimates for Target Transfer (AES # 5)

Radiation Source (Ci)

Location Release Fraction

(%)

Total Emission (Ci)

Max TEDE (Rem)

Positions (1: 1m; 2: 2m; 3: 6m)

Max CEDE-Thyroid (Rem) Positions Observations Xe-125 (A)

During transfer from MNRC to RSF 4,235 MNRC to RSF 100 4,235

1. 2.52E+02
2. 2.63E+02
3. 2.41E+02 N/A Non-Credible (MHA) 4,235 MNRC to RSF 10 424
1. 2.52E+01
2. 2.63E+01
3. 2.41E+01 N/A Credible 4,235 MNRC to RSF 1

42.4

1. 2.52E+00
2. 2.63E+00
3. 2.41E+00 N/A Credible 4,235 MNRC to RSF 0.1 4.24
1. 2.52E-01
2. 2.63E-01
3. 2.41E-01 N/A Credible 4,235 MNRC to RSF 0.01 0.424
1. 2.52E-02
2. 2.63E-02
3. 2.41E-02 N/A Credible 4,235 MNRC to RSF 0.001 0.0424
1. 2.52E-03
2. 2.63E-03
3. 2.41E-03 N/A Credible (A)

During placement into Box 1 at RSF 4,235 I-125 Lab 100 4,235

1. 1.10E+02 N/A Non-Credible (MHA) 4,235 I-125 Lab 10 424
1. 1.10E+01 N/A Credible 4,235 I-125 Lab 1

42.4

1. 1.10E+00 N/A Credible 4,235 I-125 Lab 0.1 4.24
1. 1.10E-01 N/A Credible 4,235 I-125 Lab 0.01 0.424
1. 1.10E-02 N/A Credible 4,235 I-125 Lab 0.001 0.0424
1. 1.10E-03 N/A Credible NRC Public Meeting - Dec. 18, 2012 20

Table 12. Maximum TEDE (Rem) and CEDE-Thyroid (Rem) for Accident Event Scenario # 5 (Xe-124 Target Transfer to RSF and Placement in Box 1) - Event Time 5 min Radiation Source (Ci)

Location Release Fraction (%)

Total Emission (Ci)

Max TEDE (Rem)

Positions Max CEDE-Thyroid (Rem) Positions Observations I-125 (A)

During transfer from MNRC to RSF 26 MNRC To RSF 100 26

1. 3.80E+03 (1 m)
2. 3.23E+03 (2 m)
3. 2.27E+03 (6 m)
1. 3.80E+03
2. 3.23E+03
3. 2.26E+03 Non-Credible (MHA) 26 MNRC To RSF 10 2.6
1. 3.80E+02
2. 3.23E+02
3. 2.27E+02
1. 3.80E+02
2. 3.23E+02
3. 2.26E+02 Non-Credible 26 MNRC To RSF 1

0.26

1. 3.80E+01
2. 3.23E+01
3. 2.27E+01
1. 3.80E+01
2. 3.23E+01
3. 2.26E+01 Credible 26 MNRC To RSF 0.1 0.026
1. 3.80E+00
2. 3.23E+00
3. 2.27E+00
1. 3.80E+00
2. 3.23E+00
3. 2.26E+00 Credible 26 MNRC To RSF 0.01 0.0026
1. 3.80E-01
2. 3.23E-01
3. 2.27E-01
1. 3.80E-01
2. 3.23E-01
3. 2.26E-01 Credible 26 MNRC To RSF 0.001 0.00026
1. 3.80E-02
2. 3.23E-02
3. 2.27E-02
1. 3.80E-02
2. 3.23E-02
3. 2.26E-02 Credible (A)

During placement into Box 1 at RSF 26 I-125 Lab 100 26

1. 1.23E+02 (1 m)
1. 1.23E+02 Non-Credible (MHA) 26 I-125 Lab 10 2.6
1. 1.23E+01
1. 1.23E+01 Non-Credible 26 I-125 Lab 1

0.26

1. 1.23E+00
1. 1.23E+00 Credible 26 I-125 Lab 0.1 0.026
1. 1.23E-01
1. 1.23E-01 Credible 26 I-125 Lab 0.01 0.0026
1. 1.23E-02
1. 1.23E-02 Credible 26 I-125 Lab 0.001 0.00026
1. 1.23E-03
1. 1.23E-03 Credible NRC Public Meeting - Dec. 18, 2012 21

NRC Public Meeting - Dec. 18, 2012 22 CONCLUSIONS (1) A new batch method for the production of I-125 using enriched Xe-124 gas targets will be used.

(2) Thermal neutron irradiation of a single Xe-124 target at the MNRC 2-MW Reactor will follow with a short distance (128 m) and short duration (< 15 min; < 3 min in transit) target transfer to the Radioisotope Science Facility (RSF). At RSF, newly-developed radiochemistry laboratories will be solely dedicated to processing Xe-125 radioactivity to produce I-125 in solution in a 5-6 day process. Iodine-125 is to be distributed only to properly licensed users (commercial and research).

(3) The overall process has been analyzed and evaluated for risks associated with radiological consequences (airborne releases and radiation dose) and found to be safe to operate based upon design & engineering, material specifications, procedures and administrative controls.

(4) No environmental impact is expected based on loss of containment of gaseous Xe-125 (mixed with Xe-124) due to large dispersion factors under any atmospheric conditions. Direct Iodine-125 releases are not expected because of the binding of I-125 with metal surfaces and once in solution, because of its stability in no-carrier-added radiochemical forms in strongly basic solutions.

(5) A State of California Radioactive Material License (research & education) and an amended NRC license are required for full compliance before operating RSF and producing I-125.