United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:
Entergy Nuclear Operations, Inc.
(Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:
Identified:
Admitted:
Withdrawn:
Rejected:
Stricken:
Other:
NYS000412-00-BD01 10/15/2012 10/15/2012 NYS000412 Submitted: June 29, 2012 c.\\.~p..p, REGUz.:,,,
l~\\
0
~
3:
~
i
........ 1-:
0' Entergy Originator: Benton Jr,Calvin D Originator Group: Maint Mech Staff IP3 Supenisor Name: Bouderau,Gregory Discovered Date: 04/1912011 12:01 Condition
Description:
CONDITION REPORT I CR-IP3-2011-02393 Originator Phone: 5520 Operability Required: N Reportability Required: N Initiated Date: 04/1912011 12:13 During the 3 month PM inspection of 31, 31A, and 3lB manholes under work orders 52316417, 52316418, and 52316412 respectively, the following was noted: All three manholes were filled to the top with water. 31 Manhole does not have any broken supports, but there appears to be cable lying in the bottom of the hole. It also looks like some of the cable has been cut off. 31A Manhole has a support that appears to have broken and is not supporting the cables in the center of the pit. 3lB Manhole appears to have all the supports intact, but they are heavily corroded. There appears to be a piece of channel lying in the bottom of the pit. Photos were taken and placed on the R Drive in the Manhole 31A Photos folder. There are previous photos in that folder depicting the same discrepancies as noted in this CR.
Immediate Action
Description:
Notified Supervisor and Engineering. Wrote CR.
Suggested Action
Description:
NOTE Pictures printed to pdf and attached to this section of the CR by CAA.
EQUIPMENT:
Tag Name MANHOLE 31 MANHOLE31A MANHOLE3lB REFERENCE ITEMS:
Type Code WON WON WON WON WON WON Tag Suffix Name Component Code Process System Code
?IRQ MANWAY MSCL
?IRQ MANWAY MSCL
?IRQ MANWAY MSCL Description 52316417 52316418 52316412 00274954 Y 00274955 Y 00274958 Y TRENDING (For Reference Purposes Only):
Trend Type INFO BINNING HEPFACTOR EM KEYWORDS KEYWORDS REPORT WEIGHT Attachments:
Suggested Action Description Pictures ref from R drive I PEC00235292 Trend Code ER3 E
ESSE KW -MATERIAL DEFICIENCY KW -SUPPORT PLATE
Entergy Initiated Date: 4/19/2011 12:13 Current
Contact:
Joe Reynolds Current Significance: C Closed by: Reynolds,JosephA Summary
Description:
ADMIN I CR-IP3-2011-02393 Owner Group: P&C Eng Component Mgmt IP3 4/28/2011 15:47 During the 3 month PM inspection of 31, 31A, and 3lB manholes under work orders 52316417,52316418, and 52316412 respectively, the following was noted: All three manholes were filled to the top with water. 31 Manhole does not have any broken supports, but there appears to be cable lying in the bottom of the hole. It also looks like some of the cable has been cut off. 31A Manhole has a support that appears to have broken and is not supporting the cables in the center of the pit. 3lB Manhole appears to have all the supports intact, but they are heavily corroded. There appears to be a piece of channel lying in the bottom of the pit. Photos were taken and placed on the R Drive in the Manhole 31A Photos folder. There are previous photos in that folder depicting the same discrepancies as noted in this CR.
Remarks
Description:
4/19/11: Per conversation with CR originator, Condition Description corrected. (cbh)
Closure
Description:
Per CAA review, acknowledge the CR owner (pC Eng Components) recommendation and approval to close the CR. The CR issue "During the 3 month PM inspection of 31, 31A, and 3lB manholes under work orders 52316417, 52316418, and 52316412 respectively, the following was noted: All three manholes were filled to the top with water. 31 Manhole does not have any broken supports, but there appears to be cable lying in the bottom of the hole. It also looks like some of the cable has been cut off. 31A Manhole has a support that appears to have broken and is not supporting the cables in the center of the pit. 3lB Manhole appears to have all the supports intact, but they are heavily corroded. There appears to be a piece of channel lying in the bottom of the pit. Photos were taken and placed on the R Drive in the Manhole 31A Photos folder. There are previous photos in that folder depicting the same discrepancies as noted in this CR." resolution was captured, therefore CAA noted the trend codes applied and then closed the CR.
I PEC00235293
Attachment Header Document Name:
- G~'t;t'i;d"""""""""""""""""""""'"........................................................................................................................................................................................................................................................................................................................................
Document Location
- 0U~Jy'SlU Action Description Attach
Title:
ref from R drive I PEC00235294
I PEC00235295
I PEC00235296
IPEC00235297
I PEC00235298
I PEC00235299
IPEC00235300
IPEC00235301
I PEC00235302
IPEC00235303
IPEC00235304
IPEC00235305
IPEC00235306
IPEC00235307
Entergy ASSIGNMENTS Version:
Significance Code: C Classification Code: CORRECT/ADDRESS Owner Group: P&C Eng Component Mgmt IP3 Performed By: Harrison,Christine B Assignment
Description:
IPEC00235308 04/21/2011 12:07 CR-IP3-2011-02393
Entergy I
CORRECTIVE ACTION CANumber:
1
.................................................. g~?~.p...................................................!
Assigned By: P&C Eng Component Mgmt IP3 Assigned To: P&C Eng Component Mgmt IP3 Sub assigned To: P&C Eng Component StaffIP3 Originated By: Zzip2crg Perlormed By: Manzione,Stephen J Subperlormed By: Lubrano,Louis Approved By:
Closed By: Manzione,Stephen J Current Due Date: 05/1212011 CAType: DISP - CA Plant Constraint: NONE CA
Description:
Initial Due Date:
Tesoriero,Michael V Manzione, Stephen J Lubrano,Louis 4121/2011 11:37:50 412712011 15:11:26 412712011 14:37:43 412712011 15:11:26 05/1212011 I CR-IP3-2011-02393 Name You have been assigned as the Responsible Manager for this Category "C", Non-Significant Condition Report by the CRG Address!correct the identified condition per EN -LI -102. Perform disposition review, investigate as needed, and ensure actions are assigned as applicable to correct the problem.
Response
See sub response. Recommend closure of this CR. There are no other open CAs for this CR.
Subresponse :
There has been previous documentations of the noted conditions in the manholes as found in past PMs. The responses to the past CRs include some repairs to the existing supports and pumping out of water. However, dewatering PM frequencies were never adjusted and the degraded supports have not been replaced. In the current conditions, there is no challenge to cable integrity since the cable is in supported condition. The following corrective actions have been performed 1 are recommended to achieve acceptable conditions:
- 1. Dewatering PM frequencies have been adjusted to accommodate water levels according to history:
Manhole 31 PM frequency adjusted to 1 month Manhole 31A PM frequency adjusted to 2 month Manhole 3lB PM frequency adjusted to 2 month
- 2. The following work orders have been generated to correct 1 repair degraded conditions found in the manholes:
Manhole 31 - 274954 Manhole 31A - 274955 Manhole 3lB - 274958 Closure Comments:
IPEC00235309