ML12339A706

From kanterella
Jump to navigation Jump to search
Official Exhibit - ENT00331K-00-BD01 - Appendix C - Geophysics Borehole Part 1
ML12339A706
Person / Time
Site: Indian Point  
Issue date: 03/29/2012
From:
Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
References
RAS 22129, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12339A706 (183)


Text

Project - Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 58 60 62 64 66 68 70 72 Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Page 1 ENT00331K Submitted: March 29, 2012 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

ENT00331K-00-BD01 10/15/2012 10/15/2012

74 76 78 80 82 84 86 88 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Page 2

90 92 94 96 98 100 102 104 106 Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Page 3

106 108 110 112 114 116 118 120 122 Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Page 4 1\\

I <'~4ii:'j'1 """~//

~


+~~

. j l---r~ __ 1-~--~~**~_J

~-I~"'-

~~~~

~~~-f~

~.~~

!-:"""~.

--+------r-;."

~~----1

~"

'.~,.' " ;,

-I ;;-t

. ~ j.

\\~

124 Well: GZA / Buchanan, NY - MW-53 acoustic televiewer log Page 5 II -, -

V r

.\\; r

\\

\\

\\

/

\\

/

Project - Well: GZA / Buchanan, NY - MW-54 conventional logs Depth 1in:14ft FTemp (deg C) 14.6 24.2 FRes (ohm-m) 6.7 8.3 caliper (inches) 3.4 5.4 Comments ambient flow (gpm)

-0.7 0.7 zero ambient flow

-0.7 0.7 pumping flow (gpm)

-0.7 0.7 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 all depths in feet below ground surface; a temporary stickup was approx. 0.75 feet above the floor level at the time of logging; steel casing to approximately 20.5 feet deep; water level near 7 feet deep at time of logging inflow while pumping entered between the casing bottom & 23 feet deep (probably at a small enlargement immediately below the casing); ambient downward inflow also originated in this depth interval inflow while pumping entered between 23 to 35 feet deep; minor downward ambient inflow also entered in this depth interval inflow while pumping entered between 35 to 45 feet deep (probably at several FRes inflections, & also at a minor caliper enlargement near 37.5 feet deep); weak ambient downward inflow also entered in this depth interval inflow while pumping entered between 52 to 62 feet deep (probably near the 54 & 59-foot deep FRes inflections); ambient downward flow also entered in this depth range weak inflow while pumping may have entered between 62 to 70 feet deep inflow while pumping entered between 120 to 130 feet deep; some downward ambient flow exited at a zone of lower hydraulic head in this depth interval weak inflow while pumping may have entered between 130 to 140 feet deep; weak ambient downward flow may also have exited at a zone of lower hydraulic head in this depth interval inflow while pumping entered between 140 to 150 feet deep (probably at the caliper enlargement near 145 feet); some downward ambient flow exited at a zone of lower hydraulic head in this depth interval inflow while pumping entered between 150 to 159 feet deep; some downward ambient flow also exited at a zone of lower hydraulic head in this depth interval weak inflow while pumping entered between 170 to 179 feet deep (probably at the caliper enlargement

& FRes inflection near 175 feet);

most remaining ambient downward flow also exited in this depth interval the remaining ambient downward flow exited at a zone of lower hydraulic head (probably at the 191-foot deep caliper enlargement &

FRes inflection) very weak inflow while pumping originated greater than 195 feet deep (possibly at FRes inflections near 196 to 201 feet deep) 105836 - mw54.wcl Well: GZA / Buchanan, NY - MW-54 conventional logs

Project - Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Depth 1in:1.5ft OBI40 image 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° ABI40 amplitude 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 20 22 24 26 28 30 32 34 36 38 40 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 1

42 44 46 48 50 52 54 56 58 60 62 64 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 2

66 68 70 72 74 76 78 80 82 84 86 88 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 3

90 92 94 96 98 100 102 104 106 108 110 112 114 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 4

116 118 120 122 124 126 128 130 132 134 136 138 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 5

140 142 144 146 148 150 152 154 156 158 160 162 164 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 6

166 168 170 172 174 176 178 180 182 184 186 188 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 7

190 192 194 196 198 200 202 204 Well: GZA / Buchanan, NY - MW-54 optical & acoustic televiewer logs Page 8

Project - Well: GZA / Buchanan, NY - MW-55 conventional logs Depth 1in:10ft FTemp (deg C) 17.6 22.6 FRes (ohm-m) 6 11 caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.8 0.8 zero flow (gpm)

-0.8 0.8 pumping flow (gpm)

-0.8 0.8 zero pumping flow

-0.8 0.8 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 all depths in feet below ground surface; steel casing to approximately 12 feet deep; water level near 10 feet deep at time of logging inflow while pumping entered between 14.5 to 19 feet deep (probably at the caliper enlargement & FRes inflection near 15.5 feet); very weak ambient downward flow may also have entered in this depth range inflow while pumping entered between 28 to 40 feet deep (probably at the FRes inflection near 33.5 feet deep); very weak downward ambient flow from above, & upward ambient flow from below, may also have exited at a zone of lower hydraulic head in this depth range most inflow while pumping entered between 40 to 48 feet deep; very weak upward ambient flow may also have entered in this depth range very weak inflow while pumping may have entered between 59 to 69 feet deep weak upward flow while pumping may have originated greater than 69 feet deep Well: GZA / Buchanan, NY - MW-55 conventional logs

Project - Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 12 14 16 18 20 22 24 Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Page 1

26 28 30 32 34 36 38 40 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Page 2

42 44 46 48 50 52 54 56 58 0° 180° Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Page 3

60 62 64 66 68 70 72 74 Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Page 4

76 Well: GZA / Buchanan, NY - MW-55 optical & acoustic televiewer logs Page 5

Project - Well: GZA / Buchanan, NY - MW-56 conventional logs Depth 1in:8ft FTemp (deg C) 15.3 19.9 FRes (ohm-m) 6 9

caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.3 0.3 pumping flow (gpm)

-0.3 0.3 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 all depths in feet below ground surface; steel casing to approximately 30.5 feet deep; water level near 48 feet deep at time of logging weak ambient inflow entered less than 51 feet deep, & flowed downward; inflow while pumping likely entered less than 55 feet deep (the 51-foot pumping flowmeter test could not be performed, due to insufficient room for the pump & probe with the water level lowered to almost 49 feet deep) inflow while pumping entered between 55 to 60 feet deep (possibly at the FRes inflections near 56 to 57 feet) weak ambient downward flow from above, & weak ambient upward flow from below, exited at a zone of lower hydraulic head between 66 to 74 feet deep (possibly at the FRes inflections near 69 & 73.5 feet deep); inflow while pumping also entered in this depth range inflow while pumping entered between 74 to 83 feet deep (probably at the FRes inflections near 75 & 76 feet deep) weak upward flow entered during both ambient & pumping conditions, greater than 83 feet deep (possibly at the 84-foot deep FRes inflection) 105836 - mw56.wcl Well: GZA / Buchanan, NY - MW-56 conventional logs

Project - Well: GZA / Buchanan, NY - MW-56 optical & acoustic televiewer logs Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar features 0° 0° 180° 90° 270° planar features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 26 28 30 32 34 36 38 40 Well: GZA / Buchanan, NY - MW-56 optical & acoustic televiewer logs Page 1

42 44 46 48 50 52 54 56 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-56 optical & acoustic televiewer logs Page 2

58 60 62 64 66 68 70 72 0° 180° Well: GZA / Buchanan, NY - MW-56 optical & acoustic televiewer logs Page 3

74 76 78 80 82 84 86 Well: GZA / Buchanan, NY - MW-56 optical & acoustic televiewer logs Page 4

Project - Well: GZA / Buchanan, NY - MW-57 conventional logs Depth 1in:8ft FTemp (deg C) 19.3 23.6 FRes (ohm-m) 6 8

caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.4 0.4 zero ambient flow

-0.4 0.4 pumping flow (gpm)

-0.4 0.4 zero pumping flow

-0.4 0.4 tilt-corrected planar features 0

90

-5 0

5 10 15 20 25 30 35 40 45 all depths in feet below ground surface; steel casing to approximately 6 feet deep; water level near 6.5 feet deep at time of logging weak ambient upward flow apparently exited at a zone of lower head very close to the casing bottom; an FRes inflection suggests that the 8-foot deep caliper enlargement is hydraulically active most inflow while pumping entered between 10 to 18 feet deep (probably near the caliper enlargement & FRes inflection near 11 feet, &/or the FTemp slope change near 12.5 feet);

weak ambient upward inflow also entered in this depth interval weak upward flow during pumping conditions entered between 18 to 22 feet deep (probably at the 20-foot deep FRes inflection); weak ambient downward flow also entered in this depth interval weak downward flow while pumping may have entered between 31 to 37.5 feet deep (possibly at the subtle FRes inflection near 33.5 feet) weak downward flow while pumping may have exited at a zone of lower hydraulic head between 37.5 to 42 feet deep (possibly at the very subtle FRes inflection near 38 feet) weak ambient downward flow exited at a zone of lower hydraulic head greater than 42 feet deep 105836 - mw57.wcl Well: GZA / Buchanan, NY - MW-57 conventional logs

Project - Well: GZA / Buchanan, NY - MW-57 acoustic televiewer log Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 6

8 10 12 14 16 18 Well: GZA / Buchanan, NY - MW-57 acoustic televiewer log Page 1 r 1"'--- / V II I ~

20 22 24 26 28 30 32 34 36 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-57 acoustic televiewer log Page 2

38 40 42 44 46 Well: GZA / Buchanan, NY - MW-57 acoustic televiewer log Page 3

Project - Well: GZA / Buchanan, NY - MW-58 conventional logs Depth 1in:7ft FTemp (deg C) 16.9 20.9 FRes (ohm-m) 6 14 caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.6 0.6 zero ambient flow

-0.6 0.6 pumping flow (gpm)

-0.6 0.6 zero pumping flow

-0.6 0.6 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 all depths in feet below ground surface; steel casing to approximately 14 feet deep; water level near 6 feet deep at time of logging very weak ambient upward flow may have exited at a zone of lower hydraulic head between the casing bottom & 18 feet deep (possibly at the 17-foot deep FRes slope change) inflow while pumping entered between 18 to 22 feet deep (probably at the 20-foot deep FRes inflection); very weak ambient inflow also entered in this depth interval inflow while pumping entered between 22 to 32 feet deep (possibly at the subtle FRes slope changes near 29 or 31.5 feet) inflow while pumping entered between 32 to 37 feet deep (probably at the FRes inflection near 34.5 feet); downward ambient flow also entered in this depth interval inflow while pumping entered betwen 37 to 45 feet deep (possibly at the subtle FRes slope changes near 38 & 42 feet) most inflow while pumping entered between 45 to 53 feet deep (probably at the FRes slopes change near 46 &/or 48 feet); weak ambient downward inflow also entered in this depth interval inflow while pumping entered between 53 to 61 feet deep (possibly near the 54-foot deep open planar fracture); ambient downward flow also exited at a zone of lower hydraulic head in this depth interval very weak inflow while pumping originated between 61 to 67 feet deep (possibly at the subtle FRes slope changes near 62 to 64 feet deep) 105836 - mw58.wcl Well: GZA / Buchanan, NY - MW-58 conventional logs

Project - Well: GZA / Buchanan, NY - MW-58 acoustic televiewer log Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 14 16 18 20 22 24 26 Well: GZA / Buchanan, NY - MW-58 acoustic televiewer log Page 1

28 30 32 34 36 38 40 42 44 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-58 acoustic televiewer log Page 2

46 48 50 52 54 56 58 60 Well: GZA / Buchanan, NY - MW-58 acoustic televiewer log Page 3

62 64 66 68 70 Well: GZA / Buchanan, NY - MW-58 acoustic televiewer log Page 4

Project - Well: GZA / Buchanan, NY - MW-59 conventional logs Depth 1in:6ft FTemp (deg C) 18 25.5 FRes (ohm-m) 2 13 caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-1 1

zero flow (gpm)

-1 1

pumping flow (gpm)

-1 1

zero pumping flow

-1 1

tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 all depths in feet below ground surface; steel casing to approximately 18 feet deep; water level near 13 feet deep at time of logging very weak ambient downward flow entered between the casing bottom &

19.5 feet deep most inflow induced by pumping entered between 19.5 to 26 feet deep (probably at the 21-foot deep FRes inflection & nearby caliper enlargements); very weak ambient downward flow from above, &

upward ambient flow from below, also exited at a zone of lower hydraulic head in this depth range some inflow while pumping may have entered between 26 to 35 feet deep (probably at the caliper enlargements near 27 to 30.5 feet deep, or the subtle FTemp & FRes inflections near 31 to 32 feet); some ambient upward flow may also have exited at a zone of lower hydraulic head in this depth interval inflow (during both ambient &

pumping conditions) entered between 35 to 45 feet deep (probably at the FRes inflections near 41 to 45 feet) inflow (during both ambient &

pumping conditions) entered between 54 to 64 feet deep (possibly at the numerous FRes inflections near 55 to 62 feet) upward flow (during both ambient &

pumping conditions) entered between 64 to 73 feet deep (possibly at the subtle FRes slope changes near 68 &/or 73 feet) 105836 - mw59.wcl Well: GZA / Buchanan, NY - MW-59 conventional logs

Project - Well: GZA / Buchanan, NY - MW-59 optical & acoustic televiewer log Depth 1in:1ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 18 20 22 24 26 28 30 Well: GZA / Buchanan, NY - MW-59 optical & acoustic televiewer log Page 1

32 34 36 38 40 42 44 46 48 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-59 optical & acoustic televiewer log Page 2

50 52 54 56 58 60 62 64 Well: GZA / Buchanan, NY - MW-59 optical & acoustic televiewer log Page 3

66 68 70 72 74 76 Well: GZA / Buchanan, NY - MW-59 optical & acoustic televiewer log Page 4

Project - Well: GZA / Buchanan, NY - MW-60 conventional logs Depth 1in:15ft FTemp (deg C) 12.6 20.4 FRes (ohm-m) 4 15 caliper (inches) 3.5 5.5 Comments ambient flow (gpm)

-0.3 0.3 zero ambient flow

-0.3 0.3 pumping flow (gpm)

-0.3 0.3 zero pumping flow

-0.3 0.3 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 all depths in feet below ground surface; steel casing to approximately 8.5 feet deep; water level near 11 deep feet at time of logging weak inflow while pumping may have entered between 21 to 25 feet deep FRes inflections suggest a hydraulically active zone between 34 to 42 feet deep (probably the 37-foot deep open fracture) most inflow while pumping entered between 50 to 65 feet deep (probably at the FRes decrease & caliper enlargements between 52 to 56 feet) inflow while pumping entered between 65 to 80 feet deep (probably at an FRes slope change near 70 feet, & an FRes inflection near 77 feet) inflow while pumping may have entered between 80 to 92 feet deep inflow while pumping may have entered between 92 to 106 feet deep inflow while pumping may have entered between 106 to 121 feet deep inflow while pumping entered between 149 to 165 feet deep (probably at the caliper enlargement near 156 feet) inflow while pumping originated between 180 to 196.5 feet deep 106914 - mw60.wcl Well: GZA / Buchanan, NY - MW-60 conventional logs

Project - Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Depth 1in:1.5ft OBI40 image 0° 0° 180° 90° 270° ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected ABI40 features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 6

8 10 12 14 16 18 20 22 24 26 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 1

28 30 32 34 36 38 40 42 44 46 48 50 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 2

52 54 56 58 60 62 64 66 68 70 72 74 76 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 3

78 80 82 84 86 88 90 92 94 96 98 100 0° 180° Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 4

102 104 106 108 110 112 114 116 118 120 122 124 126 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 5

128 130 132 134 136 138 140 142 144 146 148 150 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 6

152 154 156 158 160 162 164 166 168 170 172 174 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 7

176 178 180 182 184 186 188 190 192 194 196 198 200 Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 8

Well: GZA / Buchanan, NY - MW-60 optical & acoustic televiewer logs Page 9 I I IIIII I

Project - Well: GZA / Buchanan, NY - MW-62 conventional logs Depth 1in:14ft FTemp (deg C) 13.8 16.1 FRes (ohm-m) 13 25 caliper (inches) 3.5 5.5 Comments ambient flow (gpm)

-0.6 0.6 zero flow (gpm)

-0.6 0.6 pumping flow (gpm)

-0.6 0.6 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 all depths in feet below ground surface; steel casing to approximately 40.5 feet deep; water level near 11.5 feet deep at time of logging weak ambient downward inflow entered between the casing bottom & 45 feet deep inflow while pumping entered between 45 to 57 feet deep (probably at the minor caliper enlargement near 55 feet); weak ambient downward flow from above also exited at a zone of lower hydraulic head in this depth interval inflow while pumping entered between 70.5 to 80 feet deep weak inflow while pumping entered between 80 to 92 feet deep (possibly at the FRes inflections near 82 &/or 86 feet deep) inflow while pumping entered between 92 to 107 feet deep weak inflow while pumping entered between 107 to 120 feet deep inflow while pumping entered between 120 to 135 feet deep (possibly at the FRes inflection near 127 feet deep) inflow while pumping entered between 135 to 149 feet deep (possibly at the FTemp slope change near 139 feet) inflow while pumping entered between 149 to 163 feet deep inflow while pumping entered between 163 to 179 feet deep inflow while pumping entered between 179 to 194 feet deep (probably at the FRes inflection near 182 feet) inflow while pumping originated greater than 194 feet deep 105836 - mw62.wcl Well: GZA / Buchanan, NY - MW-62 conventional logs

Project - Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Depth 1in:1.5ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected ABI40 features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 40 42 44 46 48 50 52 54 56 58 60 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 1

62 64 66 68 70 72 74 76 78 80 82 84 86 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 2

88 90 92 94 96 98 100 102 104 106 108 110 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 3

112 114 116 118 120 122 124 126 128 130 132 134 136 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 4

138 140 142 144 146 148 150 152 154 156 158 160 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 5

162 164 166 168 170 172 174 176 178 180 182 184 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 6

186 188 190 192 194 196 198 200 Well: GZA / Buchanan, NY - MW-62 oprical & acoustic televiewer logs Page 7

Project - Well: GZA / Buchanan, NY - MW-63 conventional logs Depth 1in:14ft FTemp (deg C) 13.7 15.7 FRes (ohm-m) 12 30 caliper (inches) 3.5 5.5 Comments ambient flow (gpm)

-0.5 0.5 pumping flow (gpm)

-0.5 0.5 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 all depths in feet below ground surface; steel casing to approximately 36 feet deep; water level approximately 12.5 feet deep at time of logging; the minor decreases in diameter may represent casing joints near 15 &

32 feet deep inflow entered during both ambient & pumping conditions between 47.5 to 58 feet deep (probably at subtle FRes inflections near 52 to 54 feet) weak inflow entered during both ambient & pumping conditions between 70.5 to 84 feet deep inflow entered during both ambient & pumping conditions between 84 to 100.5 feet deep (probably at the numerous caliper enlargements between 87 to 98 feet) inflow entered during both ambient & pumping conditions between 110 to 119.5 feet deep (probably at subtle FRes inflections near 112 to 115 feet) weak inflow entered during both ambient & pumping conditions between 119.5 to 132.5 feet deep (possibly at numerous FRes &

FTemp inflections between 123 to 132.5 feet) inflow entered during both ambient & pumping conditions between 153 to 168 feet deep (possibly at the subtle FTemp slope change & FRes inflections near 159 to 164 feet) inflow entered during both ambient & pumping conditions between 168 to 180 feet deep (probably at the FRes inflections near 175 to 178 feet, or the FTemp slope change near 172 feet) inflow while pumping entered between 180 to 191 feet deep upward flow entered during both ambient & pumping conditions, greater than 191 feet deep 105836 - mw63.wcl GZA / Buchanan, NY - MW-63 conventional logs

Project - Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Depth 1in:1.5ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected ABI40 features 0

90 34 36 38 40 42 44 46 48 50 52 54 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 1

56 58 60 62 64 66 68 70 72 74 76 78 80 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 2

82 84 86 88 90 92 94 96 98 100 102 104 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 3

106 108 110 112 114 116 118 120 122 124 126 128 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 4

130 132 134 136 138 140 142 144 146 148 150 152 154 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 5

156 158 160 162 164 166 168 170 172 174 176 178 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 6

180 182 184 186 188 190 192 Well: GZA / Buchanan, NY - MW-63 optical & acoustic televiewer logs Page 7

Project - Well: GZA / Buchanan, NY - MW-65 conventional logs Depth 1in:8ft FTemp (deg C) 13.9 20.9 FRes (ohm-m) 4.2 5.2 caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.2 0.2 pumping flow (gpm)

-0.2 0.2 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 all depths in feet below ground surface; steel casing to approximately 34 feet deep; water level near 35.5 feet deep at time of logging ambient inflow entered less than 40 feet deep, & flowed downward towards a zone of lower hydraulic head FRes inflections near 41.5 &

possibly 43 to 44 feet deep may represent hydraulically active zones inflow while pumping entered between 46 to 50 feet deep inflow while pumping entered between 60 to 65 feet deep (possibly at a subtle FRes slope change near 61 feet deep) inflow while pumping entered between 65 to 70 feet deep (probably at the FRes inflection near 69.5 feet, or the subtle FRes slope change near 66 feet), &

flowed both up (toward the pump)

& down (toward a zone of lower hydraulic head) downward flow (during both ambient & pumping conditions) exited at a zone of lower hydraulic head greater than 80 feet deep 105836 - mw65.wcl Well: GZA / Buchanan, NY - MW-65 conventional logs

Project - Well: GZA / Buchanan, NY - MW-65 optical & acoustic televiewer logs Depth 1in:1.5ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 32 34 36 38 40 42 44 46 48 50 52 0° 180° Well: GZA / Buchanan, NY - MW-65 optical & acoustic televiewer logs Page 1

54 56 58 60 62 64 66 68 70 72 74 76 78 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-65 optical & acoustic televiewer logs Page 2

80 82 Well: GZA / Buchanan, NY - MW-65 optical & acoustic televiewer logs Page 3

Project - Well: GZA / Buchanan, NY - MW-66 conventional logs Depth 1in:14ft FTemp (deg C) 14 17.7 FRes (ohm-m) 11 17 caliper (inches) 3.5 4.5 Comments ambient flow (gpm)

-0.6 0.6 zero flow (gpm)

-0.6 0.6 pumping flow (gpm)

-0.6 0.6 tilt-corrected planar ABI features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 all depths in feet below ground surface; steel casing to approximately 37.5 feet deep; the water level was near 13 feet deep at the time of logging; very weak upward ambient flow observed at 35 feet deep may have exited at a zone of lower hydraulic head (e.g.

a casing joint less than 35 feet deep) weak inflow while pumping may have entered between the casing bottom & 41 feet deep (probably at the caliper enlargement immediately below the casing) most inflow while pumping entered between 41 to 48.5 feet deep (probably at the distinct caliper enlargement &

FRes/FTemp inflections near 43.5 feet; most upward ambient flow also exited at a zone of lower hydraulic head in this depth interval weak inflow while pumping may have entered between 48.5 to 62 feet deep (possibly at the 50.5-foot minor caliper enlargement; some upward ambient flow may also have exited at a zone of lower hydraulic head in this depth range a FRes inflection suggests a hydraulically active zone near 89 feet deep (not detected by flowmeter testing) inflow (during both ambient &

pumping conditions) may have entered between 92 to 106 feet deep (possibly at numerous FRes

&/or FTemp inflections, including 97, & 100 to 102 feet) inflow (during both ambient &

pumping conditions) entered between 106 to 122 feet deep (probably at FRes inflections &/or FTemp slope changes near 110 &

118 feet inflow while pumping entered between 122 to 137 feet deep (probably at numerous FRes inflections, including those near 125, 131.5, & 135 feet deep);

upward inflow while pumping also entered in this depth interval very weak inflow while pumping may have entered between 137 to 163 feet deep (the low pumping flow rate measured at 152 feet deep was repeatable, but appears to be incorrect due to water bypassing the diverter petals) weak inflow (during both ambient

& pumping conditions) may have entered between 163 to 177 feet deep (possibly at the FRes inflections near 165 &/or 170 feet) inflow while pumping entered between 177 to 192 feet deep (possibly at the FRes inflections near 182 to 184 feet); upward ambient inflow also originated in this depth range very weak upward flow while pumping originated greater than 192 feet deep 105836 - mw66.wcl Well: GZA / Buchanan, NY - MW-66 conventional logs

Project - Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Depth 1in:1.5ft ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° OBI40 image 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 36 38 40 42 44 46 48 50 52 54 56 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 1

58 60 62 64 66 68 70 72 74 76 78 80 82 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 2

84 86 88 90 92 94 96 98 100 102 104 106 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 3

108 110 112 114 116 118 120 122 124 126 128 130 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 4

132 134 136 138 140 142 144 146 148 150 152 154 156 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 5

158 160 162 164 166 168 170 172 174 176 178 180 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 6

182 184 186 188 190 192 194 196 198 Well: GZA / Buchanan, NY - MW-66 optical & acoustic televiewer log Page 7

Project - Well: GZA / Buchanan, NY - MW-67 conventional logs Depth 1in:13ft FTemp (deg C) 12.8 16.7 FRes (ohm-m) 7 15 caliper (inches) 3 5

Comments ambient flow (gpm)

-0.5 0.5 pumping flow (gpm)

-0.5 0.5 tilt-corrected planar features 0

90 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 all depths in feet below ground surface; steel casing to approximately 32.5 feet deep; water level near 13 feet deep at time of logging; note that strong upward ambient flow was observed within the casing, near 30 feet deep (it probably exited at a shallower casing joint, e.g. near 22 or 27 feet) inflow (during both ambient & pumping conditions) entered between the casing bottom & 38 feet deep (probably at the caliper enlargements between 33 to 36 feet) inflow while pumping entered between 38 to 45 feet deep (probably at the 40 to 43-foot deep caliper enlargement);

some upward ambient flow also exited at a zone of lower hydraulic head in this depth interval weak inflow while pumping entered between 45 to 60 feet deep; some upward ambient flow also exited in this depth range weak inflow while pumping may have entered between 60 to 74 feet deep (possibly at the subtle FTemp inflections near 61 &/or 66 feet, or at a subtle FRes slope change near 73 feet) inflow (during both ambient & pumping conditions) entered between 88 to 102 feet deep (probably at the FRes &/or FTemp inflections near 90 to 92, &/or 97 to 101 feet) inflow (during both ambient & pumping conditions) entered between 102 to 115 feet deep (probably at the 106 &

110-foot caliper enlargements, &

corresponding FRes &/or FTemp inflections) some upward flow may have exited at a zone of lower hydraulic head (during both ambient & pumping conditions) between 115 to 127 feet deep inflow (during both ambient & pumping conditions) entered between 127 to 132 feet deep weak inflow while pumping may have entered between 132 to 145 feet (probably at several FTemp &/or FRes inflections, including near 133 & 139 feet) weak inflow while pumping may have entered between 145 to 160 feet deep (possibly at subtle FTemp & FRes inflections near 148 to 149 feet, &/or a very subtle FRes slope change near 154 feet) ambient inflow may have entered between 160 to 175 feet deep (possibly at the FRes inflections near 162 &/or 173 feet) inflow while pumping may have entered between 175 to 190 feet deep (possibly at the FRes inflection near 176 feet)

Page 1 Well: GZA / Buchanan, NY - MW-67 conventional logs

200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 inflow (during both ambient & pumping conditions) entered between 205 to 215 feet deep inflow while pumping entered between 215 to 221 feet deep (probably at the FRes inflections near 216 to 219 feet) numerous FTemp & FRes inflections suggest possible hydraulically active zones between 222 to 242 feet deep (not confirmed by flowmeter testing) inflow (during both ambient & pumping conditions) entered between 250 to 264 feet deep (probably at the FRes inflections near 253 to 260 feet) inflow (during both ambient & pumping conditions) entered between 264 to 275 feet deep (probably at the caliper enlargement & FRes inflection near 269 feet) strong inflow (during both ambient &

pumping conditions) entered between 275 to 290 feet deep (probably at the FTemp slope changes & FRes inflections near 277 to 279, & possibly 282 to 284 feet) inflow while pumping may have entered between 290 to 300 feet deep (possibly at the FRes inflections near 294 &/or 300 feet) inflow (during both ambient & pumping conditions) entered between 300 to 315 feet deep (possibly at the FRes slope changes near 300, 304, &/or 307 feet) inflow while pumping may have entered between 315 to 330 feet deep (possibly near the 316, 323, &/or 329-foot FRes slope changes) upward flow (during both ambient &

pumping conditions) originated greater than 330 feet deep 105836 - mw67.wcl Page 2 Well: GZA / Buchanan, NY - MW-67 conventional logs

Project - Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Depth 1in:1.5ft OBI40 image 0° 0° 180° 90° 270° ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° planar ABI40 features 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere 30 32 34 36 38 40 42 44 46 48 50 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 1

52 54 56 58 60 62 64 66 68 70 72 74 76 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 2

78 80 82 84 86 88 90 92 94 96 98 100 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 3

102 104 106 108 110 112 114 116 118 120 122 124 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 4

126 128 130 132 134 136 138 140 142 144 146 148 150 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 5

152 154 156 158 160 162 164 166 168 170 172 174 0° 180° Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 6

176 178 180 182 184 186 188 190 192 194 196 198 200 0° 180° 0° 180° Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 7

202 204 206 208 210 212 214 216 218 220 222 224 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 8

226 228 230 232 234 236 238 240 242 244 246 248 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 9

250 252 254 256 258 260 262 264 266 268 270 272 274 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 10

276 278 280 282 284 286 288 290 292 294 296 298 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 11

300 302 304 306 308 310 312 314 316 318 320 322 324 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 12

326 328 330 332 334 336 338 Well: GZA / Buchanan, NY - MW-67 optical & acoustic televiewer logs Page 13

Project - Well: GZA / Buchanan, NY - RW-1 conventional logs Depth 1in:10ft FTemp (deg C) 17.9 21.4 FRes (ohm-m) 0 12 caliper (inches) 5 7

Comments ambient flow (gpm)

-0.6 0.6 zero ambient flow

-0.6 0.6 pumping flow (gpm)

-0.6 0.6 tilt-corrected planar features 0

90 5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 all depths in feet below top of casing; logging work was performed on a scaffold, elevated approximately 7 feet above the ground elevation as of 1/25/07; steel casing to 12 feet deep; concrete to approximately 30 feet deep; water level near 70 feet deep at time of logging weak ambient downward flow entered less than 77 feet deep (possibly at the 73-foot deep FRes inflection); some inflow while pumping also likely entered less than 77 feet deep weak inflow while pumping entered between 77 to 83 feet deep; weak ambient downward flow from above,

& upward flow from below, also exited at a zone of lower hydraulic head in this depth range inflow while pumping entered between 83 to 93 feet deep (probably at the distinct FRes inflection near 91.5 feet); weak ambient upward inflow may also have entered in this depth interval inflow while pumping entered between 93 to 98 feet deep (probably at the subtle FRes inflection near 96 feet) most inflow while pumping entered between 98 to 107 feet deep (probably at the 100.5-foot deep FRes & FTemp inflections); weak downward ambient inflow also entered in this depth range inflow while pumping entered between 107 to 118 feet deep (possibly at a small FTemp inflection near 114 to 115 feet); ambient downward flow also entered in this depth interval inflow while pumping entered between 118 to 128 feet deep; downward ambient flow exited at a zone of lower hydraulic head in this depth interval weak inflow while pumping entered between 128 to 136.5 feet deep; very weak ambient downward flow also entered in this depth range inflow while pumping originated greater than 136.5 feet deep; very weak downward ambient flow also exited at a zone of lower hydraulic head below this depth 105836 - rw1.wcl Well: GZA / Buchanan, NY - RW-1 conventional logs

Project - Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Depth 1in:1.5ft OBI40 image 0° 0° 180° 90° 270° ABI40 amplitude 0° 0° 180° 90° 270° ABI40 traveltime 0° 0° 180° 90° 270° planar ABI features (OBI above water) 0° 0° 180° 90° 270° less-open feature rose Azimuth Count - Percent Interval open feature rose Azimuth Count - Percent Interval stereoplot Schmidt Plot - Lower Hemisphere planar ABI features (OBI above water) 0° 0° 180° 90° 270° tilt-corrected planar features 0

90 6

8 10 12 14 16 18 20 22 24 26 Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 1

28 30 32 34 36 38 40 42 44 46 48 50 52 Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 2

54 56 58 60 62 64 66 68 70 72 74 76 0° 180° 0° 180° 0° 180° Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 3

78 80 82 84 86 88 90 92 94 96 98 100 Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 4

102 104 106 108 110 112 114 116 118 120 122 124 126 Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 5

128 130 132 134 136 138 140 142 Well: GZA / Buchanan, NY - RW-1 optical & acoustic televiewer logs Page 6

Appendix B Planar-feature Orientations Measured from Acoustic Televiewer Logs

Fracture Orientations Interpreted from MW-46 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw46i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 6.64 9.9 55.3 less-open 6.87 21.3 57.9 open Note that down-dip compass azimuth 7.17 17.0 61.5 less-open is perpendicular to the strike direction.

7.51 9.6 41.9 less-open 7.73 23.9 42.9 less-open Note that interpreted down-dip compass 8.12 14.7 47.1 less-open azimuths are with respect to 8.32 11.2 55.7 less-open magnetic north.

8.65 132.2 72.6 less-open 8.69 353.6 61.3 less-open Down-dip azimuths & dip angles were 8.91 358.9 54.9 less-open corrected for borehole deviation from 9.06 355.1 54.1 less-open vertical.

9.18 348.1 53.9 less-open 9.27 349.0 53.4 less-open 9.63 25.9 51.0 less-open 9.82 30.5 61.4 less-open 10.09 42.2 57.5 less-open 10.27 67.8 40.7 open 10.47 355.3 45.8 less-open 10.82 337.3 61.9 less-open 11.22 8.3 55.8 less-open 11.98 74.7 58.5 less-open 12.14 135.6 43.2 less-open 12.57 129.1 62.8 less-open 13.15 137.7 63.2 less-open 14.10 359.5 49.3 less-open 14.44 358.5 51.0 less-open 14.82 127.3 75.7 less-open 15.66 354.4 41.6 less-open 15.96 135.3 47.7 less-open 17.01 161.6 63.1 less-open 17.34 174.9 54.7 less-open 17.57 120.1 58.0 less-open 17.61 9.6 41.2 less-open 18.68 0.8 54.3 less-open 19.10 356.9 66.4 less-open 19.34 176.8 55.4 less-open 19.51 174.19 57.57 less-open 20.27 159.25 51.82 less-open 20.70 172.5 60.4 less-open 21.62 343.2 70.2 less-open 22.65 307.8 74.2 less-open 23.66 288.6 62.1 less-open 25.74 339.5 75.2 less-open 26.59 317.3 71.9 less-open Page 1 of 2

Fracture Orientations Interpreted from MW-46 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw46i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 26.87 170.5 58.6 less-open 27.80 325.8 68.9 less-open 29.58 154.7 89.9 less-open 29.83 182.1 89.5 less-open 30.10 160.7 89.5 less-open Page 2 of 2

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw53i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.49 212.0 35.9 less-open 59.87 91.4 66.4 less-open Note that down-dip compass azimuth 60.26 9.2 22.5 less-open is perpendicular to the strike direction.

61.46 186.0 21.4 less-open 61.52 239.1 80.2 less-open Note that interpreted down-dip compass 62.51 246.1 76.4 less-open azimuths are with respect to 63.02 234.1 16.3 less-open magnetic north.

63.35 243.8 76.1 less-open 63.96 248.8 80.1 less-open Down-dip azimuths & dip angles were 64.71 249.7 81.5 less-open corrected for borehole deviation from 64.93 210.7 23.7 less-open vertical.

65.30 200.0 20.3 less-open 66.26 110.1 55.4 less-open 66.92 208.2 30.9 less-open 66.93 243.4 73.6 less-open 67.07 49.5 58.9 less-open 67.58 339.7 16.7 less-open 68.22 244.1 78.7 less-open 68.89 101.2 50.7 less-open 69.39 298.0 17.5 less-open 70.71 81.8 43.0 less-open 72.16 225.0 45.6 less-open 72.43 72.0 46.6 less-open 72.64 60.7 44.5 less-open 72.87 81.0 37.1 less-open 72.97 304.5 65.7 less-open 73.11 81.7 46.4 less-open 73.29 267.3 10.4 less-open 73.32 113.4 37.6 less-open 73.64 331.3 32.8 less-open 73.84 83.1 63.7 less-open 73.94 88.7 64.5 less-open 74.26 93.2 52.8 less-open 74.36 96.8 53.6 less-open 74.47 84.6 56.2 less-open 74.69 73.1 50.8 less-open 75.09 94.2 56.8 less-open 75.44 94.9 57.8 less-open 75.55 86.8 52.7 less-open 75.73 127.6 57.6 less-open 76.20 90.8 59.6 less-open 76.35 84.4 35.3 less-open 76.39 80.7 43.6 less-open 76.80 79.2 43.2 less-open Page 1 of 3

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw53i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 77.26 97.1 49.9 less-open 77.98 97.1 63.4 less-open 78.86 91.5 57.9 less-open 79.55 81.3 48.3 less-open 79.68 249.3 26.5 less-open 79.73 67.2 40.1 less-open 83.82 283.3 39.1 less-open 83.96 227.8 20.0 less-open 85.22 175.8 82.8 less-open 85.75 181.8 83.3 less-open 87.78 173.7 48.7 less-open 87.98 176.5 18.1 less-open 90.57 278.43 42.81 less-open 90.66 71.17 34.2 less-open 91.50 282.7 76.7 less-open 91.51 124.3 49.1 less-open 92.29 291.9 39.2 less-open 92.76 223.0 23.4 less-open 93.80 300.7 27.2 less-open 94.12 231.0 32.9 less-open 94.51 296.7 54.3 less-open 95.00 165.6 64.2 less-open 95.28 149.3 65.6 less-open 95.92 98.0 50.1 less-open 96.21 213.5 34.0 less-open 96.82 97.5 78.3 less-open 98.29 73.3 75.0 less-open 100.16 86.8 44.0 less-open 100.81 317.7 47.0 less-open 101.34 307.4 39.5 less-open 101.65 285.6 57.5 less-open 103.35 78.0 68.3 less-open 103.37 319.5 42.8 less-open 103.62 241.3 41.6 less-open 103.96 75.8 70.4 less-open 104.57 72.8 68.2 less-open 104.65 273.2 39.4 less-open 104.85 272.8 47.8 less-open 105.48 302.7 24.8 less-open 105.75 281.5 22.7 less-open 106.77 299.6 24.6 less-open 106.85 270.3 26.6 less-open 108.23 176.1 63.2 less-open 109.11 169.84 47.02 less-open Page 2 of 3

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw53i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 109.67 0.31 31.98 less-open 110.19 310.4 33.0 less-open 110.61 302.7 42.1 less-open 110.80 313.3 39.0 less-open 111.13 301.4 36.0 less-open 111.56 281.4 30.2 less-open 113.18 282.1 36.0 less-open 113.37 266.8 29.7 less-open 114.51 294.1 17.0 less-open 114.95 321.5 38.6 less-open 116.43 306.7 46.2 less-open 116.66 318.2 42.1 less-open 117.27 312.4 39.0 less-open 117.44 281.6 33.8 less-open 117.78 257.5 27.7 less-open 118.40 306.9 19.2 less-open 119.38 309.7 35.5 less-open 119.61 61.3 90.0 less-open 124.11 161.2 9.3 less-open Page 3 of 3

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 20.71 47.8 68.3 less-open 21.20 70.2 57.6 less-open Note that down-dip compass azimuth 21.41 54.9 53.2 less-open is perpendicular to the strike direction.

21.52 58.1 52.1 less-open 22.36 74.3 52.4 less-open Note that interpreted down-dip compass 22.60 55.1 64.9 less-open azimuths are with respect to 22.79 74.3 44.7 less-open magnetic north.

23.14 85.2 61.3 less-open 23.32 245.7 39.5 less-open Down-dip azimuths & dip angles were 23.37 231.5 26.7 less-open corrected for borehole deviation from 23.41 235.2 19.8 less-open vertical.

23.66 65.8 70.3 less-open 25.25 223.6 31.0 less-open 25.82 252.3 6.3 less-open 26.11 304.8 5.3 less-open 26.45 256.1 8.1 less-open 27.60 60.1 74.7 less-open 28.65 62.8 43.1 less-open 31.48 141.7 64.5 less-open 31.80 303.4 55.2 less-open 32.45 304.8 18.9 less-open 32.53 269.0 18.4 less-open 32.65 110.7 68.5 less-open 32.97 101.1 64.5 less-open 33.16 98.9 68.5 less-open 33.45 80.5 72.4 less-open 33.59 85.1 71.5 less-open 33.79 85.1 72.4 less-open 33.98 85.4 72.0 less-open 34.40 86.7 66.8 less-open 34.51 104.5 65.7 less-open 34.82 79.2 34.7 less-open 35.39 115.7 71.0 less-open 35.54 98.3 60.0 less-open 35.55 127.1 70.7 less-open 36.28 88.5 70.9 less-open 37.22 90.2 80.1 less-open 37.66 94.0 75.4 open 38.47 299.5 45.9 less-open 38.76 278.2 38.4 less-open 39.40 65.4 66.8 less-open 39.43 229.8 28.7 less-open 39.82 99.8 67.3 less-open 41.26 247.7 42.4 less-open Page 1 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 43.44 356.7 68.7 less-open 43.64 96.9 71.8 less-open 43.64 75.2 61.1 less-open 44.43 112.5 20.7 less-open 45.99 285.6 67.6 less-open 47.02 312.1 76.5 less-open 48.78 90.7 76.9 less-open 49.92 93.2 75.5 less-open 50.11 95.55 65.96 less-open 50.18 137.24 39.76 less-open 50.30 97.0 71.4 less-open 50.74 101.8 66.8 less-open 51.21 91.8 67.2 less-open 52.70 213.1 34.3 less-open 53.21 97.7 58.9 less-open 53.26 126.7 17.8 less-open 54.21 173.1 11.4 less-open 54.29 254.6 4.7 less-open 55.13 116.4 66.0 less-open 55.52 117.7 61.3 less-open 55.82 110.5 56.9 less-open 56.38 99.6 55.3 less-open 56.70 102.4 65.5 less-open 57.66 75.8 76.0 less-open 58.87 345.5 32.6 less-open 59.20 325.5 60.1 less-open 59.43 110.4 38.7 less-open 59.56 334.4 58.7 less-open 60.81 76.6 50.6 less-open 61.18 322.9 63.1 less-open 61.48 289.3 69.8 open 61.77 292.6 54.4 less-open 62.54 342.7 40.4 less-open 62.90 346.7 36.8 less-open 64.24 316.9 21.8 less-open 64.90 131.8 76.8 less-open 65.14 129.3 75.3 less-open 66.50 315.0 67.5 less-open 67.36 0.6 51.5 less-open 68.03 353.27 59.96 less-open 68.45 346.94 56.72 less-open 68.52 358.3 70.8 less-open 68.92 340.8 74.2 less-open 69.29 343.9 64.2 less-open Page 2 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 69.38 105.2 53.7 less-open 70.25 97.8 60.2 less-open 70.72 115.4 63.4 less-open 70.86 342.3 51.5 less-open 71.09 307.6 43.8 less-open 71.27 324.1 54.9 less-open 72.00 106.8 72.3 less-open 72.19 104.2 69.3 less-open 72.71 108.2 66.6 less-open 73.48 100.3 68.3 less-open 74.00 101.8 67.2 less-open 74.48 106.8 74.3 less-open 75.56 279.3 71.4 less-open 76.13 320.9 75.6 less-open 76.24 102.1 65.0 less-open 77.22 106.1 42.62 less-open 77.25 97.79 65.54 less-open 77.43 111.9 59.8 less-open 78.78 108.2 82.2 less-open 79.9 208.0 54.9 less-open 80.4 200.9 43.2 less-open 80.97 197.1 50.5 less-open 81.31 151.8 36.7 less-open 82.49 64.7 38.6 less-open 84.73 201.1 55.5 less-open 85.38 342.2 68.5 less-open 86.44 330.2 76.1 less-open 87.15 354.5 48.7 less-open 87.27 343.5 48.6 less-open 88.01 326.4 60.7 less-open 88.18 323.1 54.6 less-open 88.95 114.6 72.2 less-open 89.87 330.1 66.8 less-open 90.03 356.9 60.7 less-open 90.32 6.4 67.8 less-open 90.45 90.1 22.3 less-open 91.5 330.31 61.41 less-open 91.8 312.63 54.48 less-open 92.37 147.5 74.6 less-open 92.5 345.8 57.4 less-open 93.33 150.1 65.9 less-open 93.85 147.9 76.8 less-open 95.47 267.1 37.5 less-open 96.07 119.9 57.9 less-open Page 3 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 97.15 306.9 64.7 less-open 97.62 145.05 64.89 less-open 97.65 297.43 63.7 less-open 97.78 126.9 32.0 less-open 98.28 89.7 49.3 less-open 98.33 203.7 41.3 less-open 98.89 117.7 79.7 less-open 100.31 90.0 64.9 less-open 101.02 140.4 72.7 less-open 101.48 133.7 59.9 less-open 101.99 340.7 68.1 less-open 102.21 86.5 58.4 less-open 102.57 97.69 54.19 less-open 102.96 88.35 57.77 less-open 103.22 93.9 64.2 less-open 104.37 130.5 66.3 less-open 105.64 182.9 60.3 less-open 105.7 296.0 71.7 less-open 106.64 128.6 50.2 less-open 106.65 300.8 72.4 less-open 107.08 301.8 72.0 less-open 107.56 285.5 41.0 less-open 107.82 284.9 58.4 less-open 108.11 137.9 49.5 less-open 108.41 143.9 56.2 less-open 108.86 280.2 49.5 less-open 109.19 145.8 47.1 less-open 109.71 291.7 64.6 less-open 109.73 117.7 47.4 less-open 109.97 129.3 58.5 less-open 110.15 129.6 63.3 less-open 110.52 131.5 64.9 less-open 110.85 147.7 54.2 less-open 111.47 144.8 67.6 less-open 111.78 125.0 66.1 less-open 112.62 320.3 62.8 less-open 112.89 327.8 53.9 less-open 113.88 105.5 67.5 less-open 114.08 108.9 61.8 less-open 115.33 154.1 68.2 less-open 115.48 156.6 67.9 less-open 116.64 145.5 37.2 less-open 117.38 117.4 65.1 less-open 117.96 100.1 57.8 less-open Page 4 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 118.31 93.8 55.9 less-open 118.44 97.3 56.6 less-open 118.71 110.0 55.2 less-open 119.21 128.0 67.3 less-open 119.85 126.4 61.4 less-open 120.39 131.7 54.2 less-open 120.72 126.9 64.2 less-open 120.78 193.1 43.6 less-open 121.03 114.6 62.1 less-open 121.93 137.7 66.0 less-open 122.49 153.7 75.5 less-open 122.66 299.4 77.0 less-open 122.85 149.8 80.7 less-open 123.08 300.8 73.4 less-open 123.32 177.6 46.3 less-open 123.44 309.9 60.1 less-open 123.94 142.8 60.1 less-open 123.96 283.4 60.4 less-open 124.35 243.0 32.4 less-open 124.59 245.8 33.1 less-open 124.66 253.4 34.8 less-open 124.87 114.2 51.7 less-open 125.01 111.6 80.2 less-open 125.49 113.3 42.0 less-open 125.8 164.6 74.0 less-open 126.33 152.7 75.7 less-open 127.48 297.9 46.9 less-open 129.57 107.9 45.4 less-open 129.83 236.0 55.1 less-open 130.24 103.3 62.9 less-open 130.68 96.4 57.97 less-open 130.89 93.06 38.06 less-open 131.08 106.7 51.1 less-open 131.82 123.8 41.6 less-open 133.03 314.0 29.5 less-open 133.16 308.6 48.8 less-open 133.99 129.5 55.8 less-open 135.09 331.1 56.6 less-open 136.35 111.8 49.4 less-open 137.05 98.6 57.6 less-open 137.38 74.1 43.6 less-open 137.47 115.1 63.8 less-open 137.58 95.4 51.2 less-open 137.78 88.1 56.6 less-open Page 5 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 137.9 337.5 71.8 less-open 137.97 88.8 68.3 less-open 138.09 295.0 53.4 less-open 138.66 119.7 40.0 less-open 138.94 99.2 50.4 less-open 139.27 122.5 64.1 less-open 139.51 96.5 59.2 less-open 139.57 286.5 61.6 less-open 139.59 124.8 45.9 less-open 139.97 68.8 58.3 less-open 140.15 169.3 49.5 less-open 140.41 44.7 21.1 less-open 140.45 226.2 31.8 less-open 140.5 83.7 63.1 less-open 140.74 219.4 63.0 less-open 141.23 244.3 26.9 less-open 142.24 185.0 36.8 less-open 142.43 119.6 78.1 less-open 144.42 123.5 38.1 less-open 144.49 113.1 67.7 less-open 144.61 114.4 39.6 open 144.84 124.6 41.3 open 145.01 115.8 44.3 open 145.55 95.2 44.0 less-open 145.86 114.4 41.5 less-open 146.02 104.1 46.0 less-open 146.14 97.6 44.5 less-open 146.96 175.8 75.4 less-open 147.41 187.5 36.8 less-open 148.09 325.3 56.8 less-open 148.52 214.8 60.0 less-open 148.68 196.9 35.0 less-open 148.82 178.9 53.2 less-open 149.33 188.4 40.3 less-open 149.42 236.3 48.3 less-open 149.49 183.0 40.8 less-open 149.8 138.8 68.3 less-open 150.35 81.1 49.7 less-open 150.59 90.2 44.7 less-open 150.88 122.6 69.4 less-open 151.01 104.1 62.2 less-open 151.11 357.7 80.9 less-open 151.24 101.0 40.6 less-open 151.41 109.44 47.09 less-open Page 6 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 151.51 326.3 82.15 less-open 151.56 111.92 50.04 less-open 151.94 122 34.76 less-open 152.29 141.66 34.49 less-open 152.67 136.37 19.09 less-open 152.9 115.89 49.52 less-open 153 128.63 48.23 less-open 154.36 80.63 51.46 less-open 155.49 97.7 80.56 less-open 155.63 74.18 55.48 less-open 155.69 108.38 80.21 less-open 155.85 149.48 55.4 less-open 156.47 141.61 44.08 less-open 156.79 144.32 44.71 less-open 156.99 138.16 44.02 less-open 157.19 181.39 22.46 less-open 157.47 155.01 35.6 less-open 157.75 137.27 24.69 less-open 157.97 117.06 34.56 less-open 158.23 112.25 54.24 less-open 158.56 95.88 60.66 less-open 158.81 92.67 66.08 less-open 159 118.76 63.56 less-open 159.12 106.72 64.15 less-open 159.25 199.16 54.36 less-open 159.38 102.96 57.88 less-open 159.42 200.96 54.21 less-open 159.52 96.59 65.17 less-open 160.2 174.24 23.28 less-open 160.44 109.22 72.43 less-open 161.52 97.62 61.34 less-open 161.59 101.72 72.06 less-open 162.09 67.69 48.77 less-open 162.15 189.75 62.14 less-open 162.29 102.22 55.01 less-open 162.66 270.05 67.01 less-open 162.79 112.42 79.94 less-open 163.16 257.7 23.17 less-open 163.81 41.53 67.27 less-open 164.21 75.9 76.37 less-open 164.5 111.68 76.13 less-open 164.67 136.22 76.2 less-open 166.59 110.49 70.45 less-open 166.77 103.34 56.55 less-open Page 7 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 167.12 115.01 51.46 less-open 167.78 90.05 48.31 less-open 168.4 104.05 45.28 less-open 168.58 114.26 45.14 less-open 168.8 120.57 50.57 less-open 168.84 299.18 72.09 less-open 169.27 347.29 44.11 less-open 169.48 336.05 39.28 less-open 169.61 126.83 57.28 less-open 170.51 108.91 75.55 less-open 170.9 119.85 55.09 less-open 171.09 145.65 57.06 less-open 172.27 260.45 69.61 less-open 172.59 266.38 74.6 less-open 172.65 301.97 54.36 less-open 173.22 107.06 57.71 less-open 173.55 96.22 57.95 less-open 173.82 319.98 54.15 open 173.9 282.49 63.83 open 174.28 304.29 70.31 open 175.46 99.29 65.69 open 175.68 100.21 58.12 open 176.3 107.58 61.63 less-open 176.53 114.7 60.28 less-open 177.18 131.56 74.71 less-open 177.33 133.76 69.94 less-open 177.56 127.71 70.44 less-open 177.71 115.46 74.43 less-open 178.62 205.95 58.43 less-open 178.62 356.98 34.55 less-open 179.28 135.8 57.17 less-open 179.55 357.58 85.59 less-open 179.58 125.84 51.24 less-open 179.94 111.69 32.09 less-open 180.6 102.82 40.97 less-open 181.37 174.85 68.71 less-open 181.72 337.5 38.08 less-open 181.84 37.21 32.02 less-open 181.94 215.29 69.44 less-open 182.26 252.59 30.92 less-open 182.43 138.73 66.74 less-open 183.02 113.3 71.43 less-open 183.3 353.99 74.75 less-open 183.5 106.78 73.85 less-open Page 8 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 183.85 348.1 56.02 less-open 183.9 88.16 75.46 less-open 184.48 324.09 45.12 less-open 184.71 104.66 50.09 less-open 185.31 143.73 62.28 less-open 185.43 312.61 58.3 less-open 185.58 202.59 43.8 less-open 186.25 323.48 70.49 less-open 186.28 351.99 49.28 less-open 186.63 108.02 73.31 less-open 186.71 349.1 79.18 less-open 187.43 85.19 64.98 less-open 187.66 191.18 39.72 less-open 187.71 133.74 56.02 less-open 187.98 120.92 63.88 less-open 189.96 174.43 53.43 less-open 189.98 172.49 83.74 less-open 190.27 163.97 44.03 less-open 190.76 201.7 48.33 open 191.04 146.33 46.61 open 192.42 306.81 74.35 open 193.1 101.31 40.74 less-open 193.48 132.81 42.37 less-open 193.95 201.15 59.7 less-open 194 186.46 64.05 less-open 194.17 101.92 63.2 less-open 194.72 151.66 21.52 less-open 194.74 180.84 70.53 less-open 194.94 185.74 66.82 less-open 195.41 320.64 38.82 less-open 195.58 277.04 70.22 less-open 195.95 107.66 36.37 less-open 196.75 131.09 77.23 less-open 196.9 319.35 73 less-open 197.52 305.11 62.94 less-open 197.68 106.8 43.25 less-open 197.8 301.62 57.49 less-open 198.26 165.02 82.73 less-open 198.32 144.69 75.02 less-open 199.48 49.16 41.62 open 200.29 118.03 33.85 less-open 200.52 264.76 50.98 open 200.83 290.39 44.84 less-open 201.07 302.31 50.48 less-open Page 9 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 201.24 278.07 43.53 less-open 201.72 88.77 51.77 less-open 201.89 111.94 55.94 less-open 201.97 91.13 81.6 open 202.85 134.08 53.6 less-open 203.08 131.77 89.57 less-open 203.46 271.73 89.31 less-open 203.68 268.77 89.79 less-open 203.94 289.97 89.99 less-open 204.3 99.47 89.68 less-open Page 10 of 10

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 12.43 73.7 62.7 less-open 13.14 63.9 66.6 less-open Note that down-dip compass azimuth 13.38 48.5 66.9 less-open is perpendicular to the strike direction.

13.89 316.3 61.1 less-open 14.29 137.6 60.9 less-open Note that interpreted down-dip compass 14.61 113.4 54.5 less-open azimuths are with respect to 15.20 170.0 58.7 less-open magnetic north.

15.79 143.1 50.6 less-open 15.91 161.0 79.3 less-open Down-dip azimuths & dip angles were 16.75 226.4 67.8 less-open corrected for borehole deviation from 16.91 194.7 78.6 less-open vertical.

17.09 161.4 60.0 less-open 17.21 142.2 69.7 less-open 18.38 73.2 70.2 less-open 19.43 29.1 43.8 less-open 19.75 108.2 38.3 less-open 20.01 224.4 28.0 less-open 20.45 203.3 24.3 less-open 20.52 51.6 61.4 less-open 20.97 328.2 61.3 less-open 21.94 270.5 40.0 less-open 22.08 310.2 75.2 less-open 23.31 194.2 37.0 less-open 23.55 316.6 68.4 less-open 23.73 246.0 21.6 less-open 24.09 140.7 39.0 less-open 24.50 152.3 43.3 less-open 24.83 174.2 24.4 less-open 25.04 249.8 26.7 less-open 25.29 160.3 30.5 less-open 25.62 200.1 20.9 less-open 26.15 138.5 24.3 less-open 26.95 222.6 31.1 less-open 27.61 197.7 49.5 less-open 27.66 49.2 44.1 less-open 28.36 269.6 68.4 less-open 29.50 255.6 22.9 less-open 30.14 119.8 40.4 less-open 32.29 151.6 39.7 less-open 32.64 85.1 52.9 less-open 32.73 83.2 36.8 less-open 33.07 112.3 73.0 less-open 33.23 94.4 54.6 less-open 33.26 313.6 82.7 less-open Page 1 of 4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 33.57 141.2 63.3 less-open 34.29 315.6 68.3 less-open 34.46 168.6 63.4 less-open 35.59 151.6 72.1 less-open 35.61 290.2 75.7 less-open 36.09 310.1 39.9 less-open 37.59 244.8 53.0 less-open 37.80 140.9 78.2 less-open 38.51 114.6 78.5 less-open 39.67 308.4 69.0 less-open 41.54 185.5 53.9 less-open 43.38 165.0 63.7 less-open 44.26 177.8 63.7 less-open 44.96 226.7 59.0 less-open 45.70 23.9 33.5 less-open 45.89 148.2 75.6 less-open 46.07 203.62 70.35 less-open 46.13 332.99 79.09 less-open 46.72 102.0 45.2 less-open 47.04 105.6 51.3 less-open 47.46 93.7 21.0 open 48.73 70.8 68.1 less-open 49.35 249.2 33.3 less-open 49.84 214.1 12.9 less-open 50.99 283.2 55.2 less-open 51.23 315.3 49.1 less-open 51.40 124.3 14.2 less-open 51.59 317.6 52.7 less-open 52.45 85.7 36.4 less-open 52.91 101.0 66.5 less-open 53.44 80.8 43.1 open 53.61 91.6 43.6 open 54.48 287.2 38.3 less-open 55.31 274.9 16.6 less-open 56.84 63.9 58.8 less-open 57.34 72.1 63.9 less-open 57.78 97.0 58.5 less-open 58.59 303.4 63.0 less-open 58.98 288.8 62.5 less-open 59.13 179.1 63.4 less-open 59.90 321.0 41.8 less-open 60.36 175.2 44.3 less-open 60.44 315.2 56.9 less-open 60.45 78.9 61.5 less-open Page 2 of 4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 60.68 96.1 73.6 less-open 61.30 75.6 75.9 less-open 61.41 103.2 77.8 less-open 61.55 254 73.52 less-open 61.73 74.96 65.95 less-open 61.82 290.3 41.2 less-open 62.24 268.3 51.6 less-open 62.47 89.2 50.8 less-open 62.70 311.2 43.6 less-open 63.25 304.4 37.5 less-open 63.38 87.5 51.2 less-open 63.50 325.4 55.4 less-open 63.72 238.9 29.7 less-open 64.04 95.2 73.6 less-open 64.38 87.1 68.2 less-open 64.53 280.0 51.7 less-open 64.61 295.5 48.5 less-open 64.90 74.6 31.0 less-open 64.97 85.4 70.3 less-open 65.01 313.3 78.0 less-open 65.51 359.9 52.5 less-open 65.75 170.2 78.9 less-open 65.86 324.3 43.7 less-open 66.06 105.7 51.6 less-open 66.28 62.5 68.9 less-open 66.74 340.3 49.6 less-open 66.97 358.6 55.5 less-open 67.33 5.8 56.8 less-open 67.77 1.3 54.6 less-open 68.07 5.4 46.9 less-open 68.36 338.9 47.3 less-open 68.58 207.9 71.8 less-open 69.24 302.5 48.3 less-open 69.78 121.9 57.0 less-open 69.85 201.0 60.4 less-open 70.55 295.3 38.8 less-open 71.09 270.1 26.7 less-open 71.44 187.9 48.3 less-open 71.75 203.4 59.7 less-open 72.14 93.1 65.7 less-open 72.41 187.4 56.0 less-open 73.92 255.3 27.0 less-open 74.06 178.9 59.6 less-open 74.29 162.8 60.1 less-open Page 3 of 4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 74.74 330.0 46.9 less-open 75.26 332.0 52.9 less-open 75.96 307.2 5.1 less-open 76.15 296.8 7.5 less-open 76.57 174.6 12.0 less-open Page 4 of 4

Fracture Orientations Interpreted from MW-56 Optical & Acoustic Televiewer Logs Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw56i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 31.02 193.2 77.7 less-open 32.45 172.6 51.9 less-open Note that down-dip compass azimuth 32.56 223.5 79.8 less-open is perpendicular to the strike direction.

32.91 228.3 79.4 less-open 33.01 11.8 73.6 less-open Note that interpreted down-dip compass 33.68 338.5 40.3 less-open azimuths are with respect to 35.65 144.0 20.1 less-open magnetic north.

36.90 147.2 63.8 less-open 37.81 346.6 49.7 less-open Down-dip azimuths & dip angles were 38.79 5.3 73.1 less-open corrected for borehole deviation from 39.83 85.6 30.5 less-open vertical.

40.01 115.0 34.2 less-open 41.21 13.2 67.1 less-open 41.71 301.2 52.2 less-open 42.54 1.9 59.5 less-open 42.60 155.1 64.4 open 43.33 79.6 20.0 less-open 43.83 0.8 65.0 less-open 44.42 1.0 68.8 less-open 44.83 176.1 66.8 less-open 45.02 4.3 65.8 less-open 45.29 6.9 70.5 less-open 45.70 8.3 73.7 less-open 46.96 173.3 36.4 less-open 47.05 10.0 70.6 less-open 48.10 166.9 17.8 less-open 48.39 4.4 74.6 less-open 50.31 212.2 14.6 less-open 51.62 188.2 3.2 less-open 51.70 329.9 5.7 less-open 51.78 155.6 8.3 less-open 51.94 10.3 9.4 less-open 52.50 6.0 65.7 less-open 52.84 198.0 4.6 less-open 53.20 220.7 62.2 less-open 53.68 341.3 43.8 less-open 54.13 121.1 13.3 less-open 56.09 330.9 38.3 less-open 57.17 351.7 52.6 less-open 57.20 320.9 47.7 less-open 57.22 203.7 37.4 less-open 57.59 200.8 70.3 less-open 57.62 290.5 14.6 less-open 58.17 207.9 78.3 less-open Page 1 of 3

Fracture Orientations Interpreted from MW-56 Optical & Acoustic Televiewer Logs Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw56i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.12 84.6 8.1 less-open 59.84 119.3 74.4 less-open 60.90 341.3 46.4 less-open 61.10 220.9 68.9 less-open 61.53 223.12 61.57 less-open 61.69 234.02 57.02 less-open 61.80 27.8 9.2 less-open 61.86 147.3 27.2 less-open 62.52 357.3 41.1 less-open 62.52 143.2 67.8 less-open 63.10 274.6 35.7 less-open 63.33 34.3 32.4 less-open 63.94 307.3 36.8 less-open 64.50 303.3 53.4 less-open 65.12 171.8 59.2 less-open 65.40 175.2 58.2 less-open 66.67 328.3 61.1 less-open 67.98 274.2 66.2 less-open 68.04 275.4 62.9 less-open 68.71 230.9 57.0 less-open 69.08 271.2 8.0 less-open 69.29 339.9 7.6 less-open 69.45 173.0 50.2 less-open 69.86 236.5 7.9 less-open 69.97 325.9 18.3 less-open 70.17 276.6 57.6 less-open 70.20 176.3 71.9 less-open 70.33 29.0 45.6 less-open 70.92 294.8 6.0 less-open 71.00 313.7 23.1 less-open 71.02 294.5 65.8 less-open 71.54 277.9 18.2 less-open 71.57 179.0 75.8 less-open 71.68 351.3 39.1 less-open 71.80 19.0 36.1 less-open 72.66 292.75 17.01 less-open 72.85 220.08 79.25 less-open 73.30 224.5 77.9 less-open 73.49 218.8 26.4 less-open 73.79 1.1 32.7 less-open 73.93 171.5 63.2 less-open 74.41 272.7 52.3 less-open 74.73 254.2 45.0 less-open 75.28 142.4 75.3 less-open Page 2 of 3

Fracture Orientations Interpreted from MW-56 Optical & Acoustic Televiewer Logs Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw56i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 75.59 351.8 24.1 less-open 75.77 206.1 60.7 less-open 76.08 170.7 70.9 less-open 76.61 264.1 57.9 less-open 76.96 258.2 57.5 less-open 77.04 92.8 23.8 less-open 77.07 263.1 56.8 less-open 77.33 170.4 49.3 less-open 77.53 203.97 61.43 less-open 77.54 186.69 58.9 less-open 78.64 161.9 71.6 less-open 78.80 357.0 82.9 less-open 78.92 162.2 54.7 less-open 79.13 171.07 80.07 less-open 79.25 179.42 63.94 less-open 79.39 122.5 78.8 less-open 79.77 255.8 40.1 less-open 79.96 171.5 50.8 less-open 80.5 175.0 23.6 less-open 80.66 178.2 71.3 less-open 80.75 220.7 34.8 less-open 80.83 318.4 53.0 less-open 80.98 178.3 78.0 less-open 81.11 239.4 52.6 less-open 81.19 180.2 75.5 less-open 81.58 181.1 72.7 less-open 81.72 173.8 36.1 less-open 81.9 154.6 70.5 less-open 83.01 185.9 80.3 less-open 83.93 150.2 59.4 less-open 84.27 228.9 31.3 less-open 84.28 341.8 67.2 less-open 84.59 221.0 38.6 less-open 84.86 207.4 54.4 less-open 85.35 235.87 62.96 less-open 85.61 59.54 89.93 less-open 86.14 70.5 87.3 less-open 86.51 215.7 89.5 less-open Page 3 of 3

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw57i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 6.17 133.4 77.5 less-open 6.44 64.8 16.0 open Note that down-dip compass azimuth 6.61 300.2 5.1 less-open is perpendicular to the strike direction.

6.88 162.4 44.0 less-open 7.36 235.1 36.9 less-open Note that interpreted down-dip compass 7.46 41.7 16.4 less-open azimuths are with respect to 7.75 25.6 21.9 less-open magnetic north.

7.86 336.3 8.6 open 8.53 345.4 16.3 less-open Down-dip azimuths & dip angles were 9.12 254.4 72.8 less-open corrected for borehole deviation from 9.44 352.5 48.0 less-open vertical.

10.25 45.9 29.2 less-open 10.52 40.1 18.0 less-open 10.74 355.5 20.8 less-open 10.87 15.1 31.0 less-open 11.03 28.8 25.5 open 11.12 308.4 26.8 less-open 11.24 332.1 27.3 less-open 11.41 99.0 56.1 less-open 11.99 101.7 61.8 less-open 12.20 356.5 18.4 less-open 12.70 41.0 11.0 less-open 13.42 97.9 68.3 less-open 15.90 314.5 16.3 less-open 16.34 4.4 15.5 less-open 16.34 105.8 80.4 less-open 17.61 355.4 16.2 less-open 18.44 172.2 55.9 less-open 19.58 291.9 32.1 less-open 19.82 90.1 67.9 less-open 21.17 7.9 26.3 less-open 21.76 336.3 15.9 less-open 22.01 266.5 22.1 less-open 22.85 311.4 32.7 less-open 22.86 194.6 64.5 less-open 23.76 343.6 47.0 less-open 24.19 131.9 59.8 less-open 25.08 146.6 68.2 less-open 25.76 169.6 69.0 less-open 28.16 109.9 59.0 less-open 28.35 257.3 73.2 less-open 29.15 115.3 73.5 less-open 29.71 279.9 20.8 open 29.77 82.1 74.8 less-open Page 1 of 3

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw57i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 30.12 76.8 74.2 less-open 30.46 90.7 77.5 less-open 30.95 94.5 73.0 less-open 31.81 143.4 77.6 less-open 32.02 129.2 73.3 less-open 32.04 331.4 37.0 less-open 32.37 291.45 33.23 less-open 32.5 247.4 80.52 less-open 32.72 115.1 35.5 less-open 32.87 284.4 60.6 less-open 32.96 286.0 38.2 less-open 33.37 89.9 73.8 less-open 33.37 287.5 73.5 less-open 34.23 298.4 76.8 less-open 34.57 328.7 63.4 less-open 35.30 292.2 46.1 less-open 35.59 105.1 48.3 less-open 35.64 318.2 55.7 less-open 35.81 311.9 21.7 less-open 36.08 303.6 53.3 less-open 36.37 311.8 47.1 less-open 36.53 307.1 53.3 less-open 36.73 87.2 69.4 less-open 36.79 312.2 44.7 less-open 36.97 287.1 47.9 less-open 37.16 307.1 42.9 less-open 38.09 317.2 42.2 less-open 38.31 316.3 56.1 less-open 38.45 126.8 77.5 less-open 38.76 306.4 66.3 less-open 38.85 320.7 65.4 less-open 38.96 311.7 63.9 less-open 39.15 306.6 32.2 less-open 39.38 325.6 53.3 less-open 39.64 316.6 62.8 less-open 39.80 322.6 65.5 less-open 40.03 125.5 76.3 less-open 40.7 215.86 52.44 less-open 41.35 57.99 39.92 less-open 41.44 214.6 46.7 less-open 42.13 121.6 57.1 less-open 43.03 30.7 15.2 less-open 43.06 312.4 74.4 less-open 43.26 324.9 28.7 less-open Page 2 of 3

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw57i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 43.37 290.4 67.5 less-open 43.66 115.8 52.1 less-open 43.78 83.3 82.9 less-open 43.84 92.6 53.7 less-open 44.11 72.2 66.9 less-open 44.13 349.5 76.3 less-open 44.33 85.8 78.0 less-open 44.91 327.7 89.7 less-open 45.17 309.9 89.3 less-open 45.73 305.7 89.7 less-open Page 3 of 3

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw58i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 16.76 344.0 36.5 less-open 16.95 340.6 42.7 less-open Note that down-dip compass azimuth 17.41 171.3 66.7 less-open is perpendicular to the strike direction.

17.82 357.3 67.1 less-open 17.99 349.1 58.7 less-open Note that interpreted down-dip compass 18.30 11.6 53.0 less-open azimuths are with respect to 18.72 204.5 72.9 less-open magnetic north.

18.75 20.8 32.8 less-open 18.86 3.6 67.5 less-open Down-dip azimuths & dip angles were 19.14 15.5 29.9 less-open corrected for borehole deviation from 19.28 352.8 34.8 less-open vertical.

19.43 344.0 29.1 open 19.96 164.5 66.1 less-open 20.28 335.1 57.0 less-open 20.34 162.4 70.2 less-open 20.53 170.9 62.2 less-open 20.64 340.2 35.2 less-open 20.94 158.1 65.8 less-open 21.03 345.1 31.5 less-open 21.11 351.1 34.7 less-open 21.30 351.7 41.8 less-open 21.56 342.8 41.9 open 21.81 354.9 39.1 less-open 21.97 343.2 39.8 less-open 22.40 314.6 55.7 less-open 22.94 320.7 26.7 less-open 23.23 307.1 49.5 less-open 23.38 133.0 73.2 less-open 23.49 333.7 49.8 less-open 23.92 325.0 45.9 less-open 24.04 118.5 71.6 less-open 24.40 319.2 43.7 less-open 25.06 121.2 63.5 less-open 25.10 326.9 63.3 less-open 25.16 338.6 56.7 less-open 25.31 117.1 68.6 less-open 25.38 328.5 61.5 less-open 26.18 317.0 61.1 less-open 26.28 322.3 45.0 less-open 26.46 342.8 46.6 less-open 26.94 120.7 65.7 less-open 27.37 345.2 58.7 less-open 28.08 341.1 59.6 less-open 28.36 176.3 62.7 less-open Page 1 of 3

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw58i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 28.98 339.7 58.4 less-open 29.42 328.8 40.7 less-open 30.06 319.5 43.1 less-open 30.77 312.6 42.0 less-open 31.20 149.6 64.0 less-open 32.00 311.1 36.1 less-open 32.46 313.7 32.7 less-open 33.06 290.8 35.1 less-open 33.20 300.3 28.6 less-open 33.56 310.0 32.1 less-open 34.03 339.91 41.14 less-open 34.37 132.58 60.75 less-open 34.68 282.7 29.2 less-open 35.02 113.0 66.1 less-open 35.37 102.5 62.2 less-open 35.84 100.5 67.9 less-open 35.92 332.5 66.3 less-open 36.38 312.3 43.3 less-open 36.52 111.3 64.8 less-open 36.60 302.6 53.1 less-open 37.10 312.6 45.5 less-open 37.22 326.6 40.7 less-open 37.58 323.4 39.8 less-open 38.17 314.9 50.4 less-open 38.25 314.7 47.1 less-open 38.40 311.2 58.6 less-open 38.82 332.8 32.9 less-open 39.06 95.3 70.2 less-open 39.22 298.1 40.0 less-open 39.54 297.3 47.8 less-open 39.94 327.2 56.5 less-open 40.08 96.7 70.8 less-open 40.62 94.2 70.8 less-open 41.16 313.6 32.5 less-open 41.35 78.7 70.7 less-open 41.53 296.7 24.6 less-open 42.27 305.6 52.1 less-open 42.70 333.9 42.2 less-open 43.04 301.5 47.4 less-open 43.16 295.0 52.6 less-open 43.74 316.6 46.6 less-open 44.46 101.8 63.02 less-open 44.5 335.9 45.32 less-open 45.32 342.3 39.0 less-open Page 2 of 3

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw58i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 46.27 301.2 40.8 less-open 46.98 310.0 34.9 less-open 48.89 351.1 22.6 less-open 52.82 96.6 58.6 less-open 53.46 107.2 65.3 less-open 53.77 107.0 65.8 less-open 54.36 305.0 38.6 open 56.84 290.2 40.6 less-open 57.63 295.5 50.2 less-open 58.41 162.9 73.1 less-open 59.02 105.5 63.5 less-open 59.22 302.9 61.9 less-open 59.63 282.8 64.5 less-open 60.77 297.1 61.0 less-open 60.99 101.8 66.7 less-open 61.41 122.4 63.8 less-open 61.77 103.0 67.9 less-open 63.25 301.09 37.77 less-open 64.06 71.9 66.14 less-open 64.34 143.2 63.6 less-open 64.38 319.0 35.9 less-open 64.81 291.8 41.4 less-open 64.92 181.4 67.9 less-open 65.13 177.0 69.9 less-open 65.22 170.8 68.1 less-open 65.71 178.8 70.2 less-open 65.96 323.2 53.5 less-open 66.21 110.7 61.3 less-open 66.33 107.7 65.6 less-open 66.68 288.1 55.7 less-open 66.94 111.8 59.3 less-open 67.26 115.3 67.2 less-open 67.89 100.5 69.9 less-open 67.96 108.1 71.0 less-open 68.07 305.7 53.9 less-open 68.28 108.8 72.9 less-open 68.93 95.9 65.1 less-open 70.24 192.9 6.4 less-open Page 3 of 3

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 20.77 253.8 29.3 open 21.69 221.7 62.6 less-open Note that down-dip compass azimuth 21.76 213.1 72.2 less-open is perpendicular to the strike direction.

23.51 225.7 60.8 open 23.68 217.0 69.7 less-open Note that interpreted down-dip compass 24.14 220.2 78.0 less-open azimuths are with respect to 24.14 219.1 75.4 less-open magnetic north.

24.43 132.3 48.1 less-open 24.77 354.0 50.4 less-open Down-dip azimuths & dip angles were 24.99 207.9 77.2 less-open corrected for borehole deviation from 25.11 357.9 45.9 less-open vertical.

25.19 150.9 41.4 less-open 25.33 135.7 34.0 less-open 25.51 147.6 51.7 less-open 26.12 142.0 57.0 less-open 26.19 147.3 58.4 less-open 26.79 188.0 84.0 less-open 26.88 135.2 59.9 less-open 26.94 324.5 39.0 less-open 27.18 284.7 46.2 less-open 27.25 141.6 37.0 less-open 27.30 187.5 85.0 less-open 27.34 129.3 48.1 less-open 27.99 123.9 59.1 less-open 28.14 159.0 46.2 less-open 28.45 229.4 47.1 less-open 28.83 132.6 65.8 less-open 29.09 135.8 51.6 less-open 29.40 120.2 53.7 less-open 29.43 317.1 38.4 open 29.81 141.3 54.8 less-open 30.13 324.8 43.2 open 30.19 148.0 61.5 less-open 30.43 313.3 41.8 open 30.56 317.5 45.1 less-open 31.17 195.2 41.0 less-open 31.54 183.5 38.5 less-open 31.78 304.2 45.4 less-open 32.04 305.6 46.4 less-open 32.15 114.5 65.7 less-open 32.34 120.6 57.4 less-open 32.46 120.9 58.8 less-open 32.59 211.3 64.0 less-open 32.83 123.8 68.3 less-open Page 1 of 4

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 33.54 127.6 45.9 less-open 34.06 204.3 63.6 less-open 34.16 7.1 63.4 less-open 34.27 199.7 46.9 less-open 34.99 340.4 69.6 less-open 35.68 182.9 55.9 less-open 36.78 116.3 60.4 less-open 37.07 189.0 59.3 less-open 37.63 137.0 55.1 less-open 37.88 132.2 56.9 less-open 38.22 198.2 70.9 less-open 38.64 175.4 62.1 less-open 39.66 165.5 42.6 less-open 41.65 339.1 43.9 less-open 42.24 212.49 15.37 less-open 42.47 254.48 49.31 less-open 42.79 156.3 54.4 less-open 42.90 157.8 45.8 less-open 43.11 146.5 23.5 less-open 43.37 120.2 47.9 less-open 43.47 180.5 18.6 less-open 43.52 197.0 66.7 less-open 43.68 179.6 40.7 less-open 44.60 182.0 45.7 less-open 44.66 214.0 14.0 less-open 45.10 195.7 65.7 less-open 45.95 167.4 51.6 less-open 46.44 325.3 50.5 less-open 46.44 186.8 38.4 less-open 46.69 208.9 60.7 less-open 47.60 338.7 42.2 less-open 47.99 329.3 45.2 less-open 48.25 135.7 55.0 less-open 48.37 157.4 59.2 less-open 48.46 322.6 43.1 less-open 48.67 140.6 56.8 less-open 49.41 310.2 35.3 less-open 49.75 305.3 36.4 less-open 50.23 343.3 42.2 less-open 50.41 328.9 40.3 less-open 50.57 211.7 45.0 less-open 50.93 135.0 48.0 less-open 51.43 332.3 42.3 less-open 51.65 323.8 30.0 less-open Page 2 of 4

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 51.78 320.0 42.8 less-open 52.16 314.36 42.53 less-open 52.49 203.3 60.67 less-open 52.93 320.0 36.1 less-open 53.06 193.1 66.2 less-open 53.31 338.0 39.4 less-open 53.48 319.9 36.0 less-open 54.20 324.8 34.5 less-open 55.03 213.7 71.5 less-open 55.31 203.4 70.2 less-open 55.44 326.6 35.9 less-open 55.49 208.0 66.2 less-open 55.66 297.7 31.1 less-open 56.74 311.9 18.1 less-open 57.18 330.7 39.2 less-open 57.30 318.3 33.7 less-open 57.46 324.0 47.3 less-open 57.80 189.0 74.8 less-open 58.15 319.6 26.6 less-open 58.23 312.2 31.6 less-open 58.27 309.7 48.4 less-open 58.42 314.4 36.1 less-open 58.76 186.1 56.0 less-open 59.88 335.6 36.2 less-open 60.12 351.1 40.1 less-open 60.31 329.1 33.6 less-open 60.42 340.0 38.4 less-open 60.64 184.3 73.4 less-open 60.66 323.3 34.6 less-open 61.01 104.0 71.5 less-open 61.48 116.1 66.1 less-open 61.96 328.3 40.4 less-open 62.14 144.1 62.3 less-open 62.6 12.0 9.6 less-open 62.94 310.4 22.3 less-open 63.2 134.8 66.7 less-open 63.23 313.5 51.3 less-open 63.81 123.0 26.0 less-open 65.41 297.1 30.2 less-open 65.5 301.1 31.0 less-open 67.42 158.5 60.1 less-open 67.66 320.2 40.3 less-open 67.92 321.8 41.2 less-open 68.12 318.8 41.3 less-open Page 3 of 4

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 70.44 321.5 44.9 less-open 70.83 305.9 45.6 less-open 70.92 310.8 45.1 less-open 70.98 312.44 47.62 less-open 71.18 317.72 39.27 less-open 71.32 306.7 41.6 less-open 71.44 306.6 37.3 less-open 72.32 304.0 39.4 less-open 73.58 120.6 61.9 less-open 73.71 33.5 13.6 less-open 74.25 315.6 22.7 less-open 74.72 304.5 29.3 less-open 75.17 341.8 87.4 less-open 76.25 315.8 87.6 less-open Page 4 of 4

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 10.40 296.3 36.1 less-open 11.96 104.0 35.7 less-open Note that down-dip compass azimuth 12.08 300.3 50.7 less-open is perpendicular to the strike direction.

13.20 304.0 38.7 less-open 14.40 275.6 62.4 less-open Note that interpreted down-dip compass 14.49 143.9 34.6 less-open azimuths are with respect to 16.02 103.6 57.7 less-open magnetic north.

16.86 115.8 59.7 less-open 18.00 282.9 61.1 less-open Down-dip azimuths & dip angles were 19.74 37.5 49.1 less-open corrected for borehole deviation from 20.11 249.5 31.2 less-open vertical.

20.46 112.6 47.3 less-open 22.94 315.4 51.9 less-open 27.05 134.0 35.0 less-open 29.75 99.8 53.9 less-open 36.27 221.8 56.7 less-open 36.47 331.5 61.0 less-open 36.99 302.7 48.2 open 37.39 323.2 39.3 less-open 38.54 24.7 13.4 less-open 39.31 118.5 63.4 less-open 39.73 110.4 59.4 less-open 40.60 125.3 72.0 less-open 43.20 205.1 57.5 less-open 49.41 132.4 45.1 less-open 50.09 147.4 86.1 less-open 52.30 313.7 42.3 less-open 52.64 9.1 31.1 less-open 52.82 336.8 41.9 less-open 53.12 354.1 61.8 less-open 53.64 331.3 23.5 less-open 54.14 273.9 67.7 less-open 54.14 258.6 59.2 less-open 54.42 341.7 22.1 open 55.83 324.8 58.6 open 55.86 253.8 4.9 less-open 56.89 325.8 42.0 less-open 57.06 303.9 58.3 less-open 57.62 326.3 73.2 less-open 58.23 327.4 74.8 less-open 58.78 336.8 77.8 less-open 59.00 351.8 76.3 less-open 60.03 306.9 52.6 less-open 60.07 147.5 52.1 less-open Page 1 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 60.65 336.8 61.9 less-open 60.67 148.9 70.3 less-open 61.21 109.9 36.2 less-open 61.99 330.3 53.0 less-open 62.23 325.0 59.4 less-open 63.97 307.1 63.1 less-open 64.16 325.5 68.7 less-open 64.25 311.8 49.4 less-open 64.32 201.8 67.6 less-open 64.33 298.9 45.9 less-open 65.01 197.35 72.97 less-open 65.45 312.86 63.37 less-open 66.44 307.7 63.6 less-open 68.01 323.4 77.1 less-open 68.29 300.2 74.1 less-open 69.39 126.8 42.4 less-open 69.59 131.2 39.7 less-open 69.83 292.7 67.5 less-open 70.53 309.2 70.3 less-open 70.67 103.4 53.9 less-open 71.50 323.6 70.7 less-open 71.80 319.6 63.5 less-open 72.77 319.5 60.2 less-open 73.78 324.9 59.6 less-open 74.10 309.6 61.8 less-open 74.40 274.5 67.2 less-open 74.83 80.5 15.5 less-open 74.95 185.8 65.6 less-open 75.20 186.9 68.5 less-open 75.96 315.5 46.2 less-open 76.39 323.4 42.6 less-open 77.23 353.9 17.3 less-open 77.34 38.5 21.2 less-open 78.12 284.1 68.3 less-open 78.69 220.5 79.9 less-open 84.49 318.3 48.1 less-open 84.71 324.9 56.1 less-open 85.36 303.7 48.1 less-open 90.85 31.4 31.4 less-open 91.38 158.4 73.3 less-open 91.64 310.8 32.4 less-open 92.9 169.38 80.19 less-open 93.3 191.92 32.75 less-open 93.73 172.1 66.6 less-open Page 2 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 93.81 232.1 45.3 less-open 94.97 303.6 39.1 less-open 95.18 195.9 53.5 less-open 95.39 98.1 77.3 less-open 96.46 327.0 44.5 less-open 98.00 288.1 68.1 less-open 98.23 311.6 69.6 less-open 99.24 313.0 66.3 less-open 99.43 341.8 64.4 less-open 100.51 267.9 67.9 less-open 100.83 135.4 58.0 less-open 101.41 158.3 26.9 less-open 102.04 151.1 31.3 less-open 102.54 192.9 67.8 less-open 102.94 191.2 79.4 less-open 103.87 209.9 81.2 less-open 104.51 357.4 49.7 less-open 104.85 344.1 46.6 less-open 107.14 93.6 67.0 less-open 107.23 139.0 44.3 less-open 107.82 94.5 19.7 less-open 108.3 126.3 27.6 less-open 108.86 334.8 76.3 less-open 109.35 309.5 70.1 less-open 110.23 319.3 58.7 less-open 110.43 311.4 58.7 less-open 110.61 313.3 59.5 less-open 111.11 192.3 31.1 less-open 111.35 150.0 33.6 less-open 111.84 167.5 66.4 less-open 112.38 148.7 65.4 less-open 113.09 307.1 32.5 less-open 113.72 329.2 31.4 less-open 114.14 111.6 55.3 less-open 116.59 14.3 53.0 less-open 116.89 99.6 66.8 less-open 117.53 117.0 44.7 less-open 117.91 117.7 37.1 less-open 118.37 139.2 38.5 less-open 118.62 120.6 46.7 less-open 119.19 329.5 73.8 less-open 119.59 145.6 50.4 less-open 119.87 143.2 36.5 less-open 120.16 120.86 29.75 less-open Page 3 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 120.64 118.02 67.72 less-open 122.21 136.9 29.9 less-open 122.37 123.2 41.5 less-open 122.54 126.0 29.7 less-open 122.7 146.6 35.6 less-open 122.93 131.4 33.7 less-open 123.15 130.8 42.4 less-open 123.35 126.0 29.9 less-open 125.48 118.1 57.0 less-open 126.31 139.8 35.1 less-open 127.91 141.48 38.06 less-open 128.72 332.45 58.01 less-open 128.78 144.1 40.2 less-open 129.39 155.9 53.1 less-open 129.83 133.6 46.7 less-open 131.48 119.5 28.8 less-open 133.43 165.6 33.2 less-open 135.7 132.4 56.3 less-open 136.57 143.5 33.1 open 136.69 122.1 31.3 open 136.82 123.7 30.3 less-open 137.19 132.7 45.3 less-open 137.34 119.4 46.6 less-open 137.87 146.9 33.0 less-open 138.06 176.7 26.3 less-open 139.39 150.8 33.4 less-open 140.27 131.2 34.9 less-open 140.74 133.9 34.2 less-open 141.43 106.5 40.4 less-open 142.39 141.5 33.0 less-open 142.5 142.2 28.7 less-open 142.63 149.9 27.8 less-open 142.94 137.2 30.1 less-open 145.3 127.9 31.1 less-open 145.38 130.2 30.1 less-open 146.06 151.5 33.2 less-open 146.73 137.1 34.0 less-open 148.94 321.3 80.5 less-open 149.76 133.2 33.0 less-open 150.12 129.0 35.1 less-open 150.35 130.7 38.7 less-open 150.46 119.7 35.2 less-open 150.58 116.2 42.8 less-open 151.1 157.0 37.2 less-open Page 4 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 151.51 158.6 36.7 less-open 151.62 150.1 34.3 less-open 151.68 146.2 31.7 less-open 151.84 143.7 30.2 less-open 152.01 143.4 35.1 less-open 152.55 144.5 38.7 less-open 152.81 141.9 37.6 less-open 153.39 134.3 39.4 less-open 153.46 147.9 37.8 less-open 153.74 140.9 38.9 less-open 155.22 117.0 45.1 less-open 155.58 128.6 51.7 less-open 155.66 342.4 34.3 less-open 155.86 124.9 35.6 open 156.17 142.8 35.7 less-open 156.49 123.4 45.6 less-open 156.91 152.7 38.7 less-open 157.09 142.1 37.2 less-open 158.08 133.7 42.1 less-open 158.3 320.2 70.8 less-open 158.42 115.2 48.3 less-open 158.9 104.4 60.3 less-open 159.11 95.3 75.4 less-open 160.01 99.7 77.5 less-open 160.54 305.9 42.2 less-open 160.83 93.4 77.3 less-open 162.32 312.4 46.4 less-open 162.55 4.4 26.0 less-open 163.17 118.2 49.93 less-open 163.43 115.25 61.31 less-open 163.81 310.1 48.5 less-open 163.92 105.7 58.3 less-open 164.64 323.3 74.6 less-open 165.75 3.0 45.2 less-open 166.1 131.9 48.6 less-open 166.44 150.5 46.7 less-open 166.79 230.8 30.3 less-open 166.87 240.9 30.3 less-open 167.59 141.5 25.5 less-open 167.96 168.2 29.5 less-open 168.6 164.2 33.4 less-open 169.15 147.4 37.3 less-open 169.76 137.2 36.0 less-open 170.01 140.3 46.1 less-open Page 5 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 170.5 179.7 38.7 less-open 171.33 165.6 35.5 less-open 172.15 135.5 42.0 less-open 172.77 340.7 32.7 less-open 173.92 123.0 34.3 less-open 174.02 160.0 40.8 open 174.25 7.8 53.2 less-open 174.31 100.4 35.5 less-open 174.67 135.3 44.5 less-open 174.92 128.2 41.4 less-open 175.11 151.7 34.5 less-open 175.79 179.4 51.3 less-open 176.98 193.5 40.0 less-open 177.26 127.4 47.1 less-open 177.75 121.6 44.9 less-open 178.07 108.3 50.0 open 178.31 111.9 45.7 open 179.73 336.4 54.6 less-open 180.35 123.4 54.8 less-open 180.85 263.5 66.5 less-open 182.89 268.7 78.7 less-open 184.41 123.3 63.0 less-open 186.09 219.5 33.0 less-open 186.31 264.8 67.7 less-open 187.15 317.3 66.3 less-open 187.83 276.3 64.5 less-open 188.27 114.2 60.8 less-open 189.48 344.8 54.3 less-open 189.98 109.2 55.9 less-open 190.74 139.3 31.4 less-open 190.91 109.0 57.6 less-open 191.56 132.5 47.1 less-open 192.04 110.6 53.71 less-open 192.27 351.37 75.1 less-open 192.91 116.9 52.3 less-open 193.4 114.9 39.3 less-open 193.65 140.1 38.6 less-open 193.71 165.7 32.6 less-open 193.9 129.4 40.5 less-open 194.13 129.4 53.2 less-open 194.41 139.4 42.9 less-open 195.27 101.0 62.9 less-open 195.54 93.2 71.9 less-open 197.4 122.53 46.45 less-open Page 6 of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 198.21 230.33 27.44 less-open 199.28 162.06 53.05 less-open 200.14 116.4 89.22 less-open 200.31 152.88 89.64 less-open 200.52 233.74 88.98 less-open 200.95 121.87 89.1 less-open Page 7 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 43.33 35.9 38.3 less-open 43.47 95.5 68.3 less-open Note that down-dip compass azimuth 44.24 351.6 50.0 less-open is perpendicular to the strike direction.

44.28 99.9 71.1 less-open 44.46 327.2 50.8 less-open Note that interpreted down-dip compass 44.56 347.2 32.2 less-open azimuths are with respect to 44.77 346.3 33.4 less-open magnetic north.

44.82 105.2 74.2 less-open 45.40 315.6 44.6 less-open Down-dip azimuths & dip angles were 45.80 98.5 63.9 less-open corrected for borehole deviation from 46.10 100.7 67.0 less-open vertical.

46.48 105.9 64.3 less-open 46.77 331.1 31.5 less-open 47.01 92.8 51.8 less-open 47.38 331.4 49.6 less-open 47.65 292.9 33.8 less-open 47.97 117.7 73.2 less-open 47.98 102.3 73.0 less-open 48.31 109.2 68.9 less-open 48.89 337.6 21.2 less-open 49.14 98.5 64.8 less-open 49.83 111.8 70.0 less-open 50.44 90.0 69.5 less-open 50.63 99.3 74.3 less-open 51.40 94.9 77.7 less-open 51.67 100.1 72.2 less-open 52.71 11.7 24.5 less-open 52.95 99.0 72.4 less-open 53.32 306.1 38.7 less-open 53.44 203.3 72.9 less-open 53.82 300.6 35.3 less-open 53.89 107.9 68.9 less-open 54.26 206.8 69.2 less-open 54.71 207.4 65.3 less-open 54.97 213.7 67.6 less-open 55.12 204.9 63.8 less-open 55.35 207.2 71.4 less-open 55.84 300.8 44.9 less-open 56.20 309.6 43.1 less-open 56.73 198.6 73.3 less-open 57.74 74.2 12.2 less-open 58.29 85.2 68.2 less-open 58.70 66.5 75.5 less-open 58.70 108.1 67.7 less-open Page 1 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.43 312.0 49.1 less-open 60.12 104.9 66.7 less-open 60.33 197.2 81.0 less-open 60.43 291.01 65.26 less-open 61.73 5.58 24.04 less-open 62.36 306.8 31.7 less-open 62.73 99.58 67.95 less-open 63 300.07 64.71 less-open 63.61 208.7 60.1 less-open 63.84 111.3 63.5 less-open 64.65 100.0 65.8 less-open 64.78 213.5 59.6 less-open 64.94 303.2 46.6 less-open 65.35 108.3 70.5 less-open 65.89 111.7 67.7 less-open 66.36 112.5 63.7 less-open 66.56 122.2 64.8 less-open 66.92 110.3 62.7 less-open 67.54 109.0 49.7 less-open 67.86 104.0 67.8 less-open 68.16 283.7 42.9 less-open 68.29 99.0 74.7 less-open 68.38 93.3 58.3 less-open 68.82 97.4 64.8 less-open 69.19 215.7 67.2 less-open 69.83 220.4 71.7 less-open 70.09 116.0 61.7 less-open 71.06 114.9 60.0 less-open 71.45 130.4 61.9 less-open 72.05 107.2 67.4 less-open 72.09 209.1 58.5 less-open 72.22 100.4 70.3 less-open 72.64 295.4 36.4 less-open 72.72 90.5 67.1 less-open 73.46 119.2 65.5 less-open 73.85 346.1 45.7 less-open 74.13 108.9 65.4 less-open 74.29 344.76 45.71 less-open 74.55 306.53 60.33 less-open 74.93 351.2 49.7 less-open 75.12 107.5 62.8 less-open 75.38 117.5 67.4 less-open 75.64 107.7 67.5 less-open 75.89 352.2 48.6 less-open Page 2 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 76.02 355.5 52.1 less-open 76.46 112.2 70.7 less-open 76.82 357.3 36.6 less-open 77.33 300.6 26.5 less-open 78.19 2.9 55.3 less-open 78.56 127.1 63.0 less-open 79.56 110.2 64.1 less-open 81.07 262.3 69.5 less-open 81.48 318.5 54.3 less-open 81.60 347.7 54.7 less-open 81.67 306.4 38.3 less-open 82.28 332.0 28.2 less-open 82.53 1.1 23.5 open 82.88 337.7 35.1 less-open 82.95 355.3 45.5 less-open 82.99 94.5 69.6 less-open 83.02 304.8 45.7 less-open 83.26 122.0 72.0 less-open 84.02 305.3 38.2 less-open 84.4 279.7 61.5 less-open 84.81 108.4 66.6 less-open 85.95 34.3 32.8 less-open 86.49 349.5 48.7 less-open 86.68 104.4 69.1 less-open 87.44 112.1 67.8 less-open 87.83 67.7 68.3 less-open 88.01 102.5 67.7 less-open 88.66 112.3 68.7 less-open 88.8 286.2 48.2 less-open 89.82 325.0 47.7 less-open 89.98 289.4 54.1 less-open 90.35 338.8 30.9 less-open 90.72 331.3 56.5 less-open 90.84 1.6 52.8 less-open 91.04 108.4 65.0 less-open 91.09 296.1 50.4 less-open 91.75 354.8 56.1 less-open 92.53 325.1 52.1 less-open 92.68 320.4 48.3 less-open 93 356.7 53.62 less-open 93.47 330.48 64.81 less-open 93.59 357.1 54.3 less-open 93.7 303.6 53.9 less-open 94.19 327.0 43.8 less-open Page 3 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 94.46 322.0 43.5 less-open 94.65 319.2 46.9 less-open 95.09 321.0 48.9 less-open 95.91 328.5 47.8 less-open 97.76 278.0 47.8 less-open 99.14 105.1 61.9 less-open 99.17 308.41 44.25 less-open 99.61 304.96 62.27 less-open 100.51 311.6 41.5 less-open 100.78 356.9 55.7 less-open 100.97 344.5 25.3 less-open 103.47 115.5 63.8 less-open 103.57 114.8 61.6 less-open 103.72 316.3 39.8 less-open 104.45 87.5 63.1 less-open 105.87 303.7 60.8 less-open 106.43 113.8 59.2 less-open 106.86 282.5 56.1 less-open 107.54 29.6 53.5 less-open 108.05 29.6 56.8 less-open 108.86 252.0 50.2 less-open 109.21 302.7 45.9 less-open 110.54 307.5 36.3 less-open 110.77 310.9 41.7 less-open 111.1 110.5 62.8 less-open 111.23 293.4 36.0 less-open 111.82 107.8 66.2 less-open 113.15 314.8 38.1 less-open 113.3 305.8 39.9 less-open 114.7 312.2 37.3 less-open 115.95 1.0 43.1 less-open 116.56 359.6 52.3 less-open 116.74 111.4 66.2 less-open 117.49 336.6 50.4 less-open 117.73 316.9 47.8 less-open 117.99 50.0 44.5 less-open 118.14 111.4 66.2 less-open 118.98 96.6 64.1 less-open 119.33 302.6 43.2 less-open 119.88 115.9 60.9 less-open 120.41 295.8 49.9 less-open 120.65 108.5 63.8 less-open 120.66 329.1 32.6 less-open 120.98 101.6 66.2 less-open Page 4 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 120.99 2.9 37.6 less-open 121.36 315.0 46.6 less-open 121.64 309.9 43.0 less-open 122.18 296.2 38.7 less-open 122.6 340.8 48.8 less-open 122.89 294.8 67.7 less-open 123.41 324.7 57.0 less-open 123.8 311.7 75.7 less-open 123.86 127.1 58.9 less-open 124.75 295.9 60.3 less-open 124.92 52.2 60.8 less-open 128.82 61.4 67.8 less-open 129.8 351.1 69.6 less-open 130.28 281.2 33.4 less-open 130.56 121.5 59.9 less-open 130.85 115.6 56.4 less-open 131 281.5 37.7 less-open 132.23 101.4 67.3 less-open 132.57 109.0 64.0 less-open 132.85 119.5 62.0 less-open 133.13 92.3 67.5 less-open 134.06 119.4 63.1 less-open 134.32 118.5 62.1 less-open 134.65 106.2 58.5 less-open 135.19 114.44 64.63 less-open 135.39 125.78 61.15 less-open 135.64 114.8 62.9 less-open 135.84 108.8 66.4 less-open 136.54 105.2 63.6 less-open 137.03 299.8 62.2 less-open 138.54 315.7 69.8 less-open 139.01 100.4 69.4 less-open 139.21 92.9 71.0 less-open 139.63 116.7 63.0 less-open 140.52 325.6 50.5 less-open 140.76 104.7 71.8 less-open 143.61 332.3 10.6 less-open 144.4 328.6 55.8 less-open 144.91 110.5 63.9 less-open 145.54 340.0 33.4 less-open 148.71 105.1 70.2 less-open 149.95 332.8 64.3 less-open 150.24 101.7 68.8 less-open 150.7 190.2 27.0 less-open Page 5 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 150.74 207.1 69.6 less-open 151.03 83.0 70.5 less-open 151.24 83.0 66.2 less-open 152.27 339.3 57.7 less-open 152.42 336.7 58.9 less-open 153.24 240.4 24.2 less-open 153.31 254.0 34.0 less-open 153.75 340.8 50.7 less-open 153.89 339.0 55.8 less-open 155.3 343.2 54.0 less-open 156.87 328.7 47.9 less-open 158.23 333.8 33.5 less-open 158.38 332.6 46.9 less-open 159.03 322.2 54.7 less-open 159.32 321.8 39.5 open 159.7 332.4 48.9 less-open 159.78 325.5 47.2 less-open 160.5 332.1 47.0 less-open 160.51 115.5 60.8 less-open 160.8 105.3 63.8 less-open 161.15 320.5 45.4 less-open 161.56 315.0 48.7 less-open 161.69 325.6 45.3 less-open 161.93 320.6 49.5 less-open 162.2 324.0 45.8 less-open 162.37 322.0 44.7 less-open 163.38 84.0 46.1 less-open 163.87 25.8 21.2 less-open 164.07 101.5 70.2 less-open 164.41 98.79 72.05 less-open 165.42 359.5 47.5 less-open 165.44 285.4 34.9 less-open 166.03 342.8 47.4 less-open 168.12 6.2 49.2 less-open 168.67 31.4 16.3 less-open 169.28 28.3 58.3 less-open 169.37 332.8 50.6 less-open 169.67 43.7 42.9 less-open 170.28 44.1 67.9 less-open 170.37 57.11 35.34 less-open 170.77 34.39 27.47 less-open 171.24 65.69 35.01 less-open 171.73 341.53 57.13 less-open 172.57 335.41 56.48 less-open Page 6 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 173.46 10.43 53.91 less-open 173.99 323.84 58.9 less-open 174.16 338.07 51.91 less-open 174.49 335.32 49.31 less-open 174.83 311.21 59.01 less-open 175.71 332.86 65.51 less-open 175.84 92.52 71.41 less-open 179.07 95.76 67.85 less-open 179.24 97.17 70.62 less-open 179.92 329.87 71.17 less-open 181.48 249.48 62.23 less-open 182.32 12.37 42.33 less-open 184.03 151.01 68.38 less-open 184.23 322.28 71.21 less-open 184.42 307.68 45.33 less-open 185.34 249.46 58.86 less-open 185.79 349.03 30.78 less-open 186.81 76.35 45.93 less-open 188.54 303.13 39.12 less-open 188.89 317.52 47.22 less-open 189.81 298 73.28 less-open 190.68 31.9 14.42 less-open 190.91 346.94 22.29 less-open 193.29 296.54 77.33 less-open 193.65 294.57 42.41 less-open 195.42 301.71 16.23 less-open 195.91 332.07 16.06 less-open 196.37 333.48 49.34 less-open 196.49 98.98 72.33 less-open 196.68 130.8 76.02 less-open 196.71 128.03 52.57 less-open 197.12 57.65 41.03 less-open 197.2 45.38 37.82 less-open 197.32 127.06 65.5 less-open 197.34 129.94 68.23 less-open 197.67 113.41 69.54 less-open 198.24 13.18 32.18 less-open 198.71 19.77 87.87 less-open 199.02 11.6 87.35 less-open Page 7 of 7

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 36.98 87.0 56.2 less-open 37.28 84.2 48.8 less-open Note that down-dip compass azimuth 37.41 282.4 39.6 less-open is perpendicular to the strike direction.

37.44 87.1 49.4 less-open 37.46 64.5 57.1 less-open Note that interpreted down-dip compass 37.49 257.0 42.6 less-open azimuths are with respect to 38.08 79.2 57.1 less-open magnetic north.

38.33 266.2 26.9 less-open 39.01 143.8 76.0 less-open Down-dip azimuths & dip angles were 39.69 147.1 75.5 less-open corrected for borehole deviation from 40.12 283.5 24.5 less-open vertical.

40.53 193.5 42.5 less-open 40.90 275.8 26.0 less-open 41.22 275.0 20.6 less-open 41.31 248.9 67.4 less-open 41.47 236.3 49.5 less-open 41.76 213.0 55.1 less-open 42.53 287.8 14.3 less-open 42.80 280.5 14.9 less-open 42.89 308.5 16.3 less-open 43.10 83.9 53.7 less-open 43.17 241.5 64.5 less-open 43.31 100.1 41.9 less-open 43.78 90.3 43.7 less-open 44.27 89.3 60.1 less-open 44.45 269.4 63.8 less-open 44.57 109.5 79.6 less-open 45.14 316.0 58.4 less-open 45.20 7.2 22.6 less-open 45.59 83.1 57.7 less-open 45.69 277.9 41.6 less-open 45.75 280.4 38.5 less-open 45.78 96.6 39.4 less-open 45.78 97.5 57.6 less-open 45.98 103.2 50.0 less-open 46.30 89.5 55.2 less-open 46.55 305.9 33.1 less-open 46.59 81.6 50.0 less-open 46.68 98.0 57.4 less-open 46.87 89.9 69.2 less-open 47.12 278.9 39.0 less-open 47.48 267.9 43.1 less-open 48.32 259.9 46.4 less-open 48.34 108.6 63.5 less-open Page 1 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 48.43 191.9 48.2 less-open 48.72 269.04 42.11 less-open 48.95 290 42.87 less-open 49.01 94.3 61.2 less-open 49.41 311.47 31.1 less-open 49.95 289.66 35.66 less-open 50.33 279.3 44.4 less-open 50.51 90.4 57.5 less-open 50.55 306.5 38.2 less-open 50.74 320.4 34.2 less-open 50.97 87.5 54.3 less-open 51.04 96.8 52.0 less-open 51.17 253.2 62.6 less-open 51.25 85.6 35.1 less-open 51.56 149.4 78.6 less-open 51.93 316.1 42.7 open 52.11 307.0 32.6 less-open 52.27 325.6 39.8 less-open 52.43 319.0 47.3 open 52.62 301.9 36.7 less-open 52.69 102.4 42.1 less-open 52.81 102.6 44.9 less-open 52.92 265.4 51.3 less-open 53.56 102.4 66.7 less-open 53.59 300.7 41.9 less-open 53.70 53.8 51.9 less-open 53.77 112.5 41.7 less-open 54.09 312.1 42.1 less-open 54.16 102.7 38.5 less-open 54.50 251.0 55.1 less-open 54.70 310.0 46.7 less-open 54.79 299.1 44.7 less-open 54.91 295.6 49.2 open 55.11 80.7 42.5 less-open 55.51 105.3 39.9 less-open 55.67 299.14 41.72 less-open 55.73 107.05 44.95 less-open 56.01 290.6 46.6 less-open 56.38 301.6 47.2 less-open 56.39 89.1 40.8 less-open 56.64 308.3 62.0 less-open 57.19 97.2 47.6 less-open 57.25 307.9 53.1 less-open 57.36 307.6 56.4 less-open Page 2 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 57.49 316.1 52.0 less-open 57.61 314.9 52.9 less-open 57.80 315.0 47.8 less-open 57.96 307.0 48.2 less-open 58.41 144.9 64.2 less-open 58.49 272.6 33.4 less-open 58.58 101.0 52.4 less-open 58.76 91.8 46.7 less-open 58.95 301.0 47.2 less-open 59.22 79.0 32.5 less-open 59.48 97.2 42.9 less-open 59.92 94.4 36.3 less-open 60.26 295.0 40.2 less-open 60.37 78.0 54.2 less-open 60.43 305.6 36.9 less-open 60.49 102.7 52.6 less-open 60.72 325.0 68.6 less-open 60.95 114.8 46.4 less-open 61.39 109.4 53.0 less-open 61.54 319.3 75.4 less-open 62.55 127.4 46.2 less-open 62.98 123.1 72.5 less-open 63.26 295.3 44.6 less-open 63.59 258.3 31.2 less-open 63.82 103.5 59.2 less-open 64.23 264.9 36.5 less-open 64.33 98.2 65.0 less-open 64.42 92.8 64.4 less-open 64.84 91.8 55.1 less-open 64.89 127.6 23.1 less-open 65 98.3 55.7 less-open 65.14 91.9 44.7 less-open 65.6 95.8 41.8 less-open 65.92 86.3 52.4 less-open 66.05 89.0 57.4 less-open 66.19 95.9 44.7 less-open 66.2 250.9 62.7 less-open 66.22 297.83 80.36 less-open 66.3 99.31 42.17 less-open 66.5 323.7 23.9 less-open 66.66 324.1 40.3 less-open 66.83 308.7 29.0 less-open 66.99 83.0 43.5 less-open 67.12 91.3 58.4 less-open Page 3 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 67.21 86.6 42.6 less-open 67.28 290.1 48.9 less-open 67.52 329.3 51.2 less-open 67.74 79.7 43.2 less-open 67.88 90.74 30.17 less-open 68.18 260.41 33.48 less-open 68.53 292.4 70.1 less-open 68.55 306.6 47.8 less-open 68.67 82.1 29.7 less-open 68.97 294.4 67.6 less-open 69.27 335.9 31.2 less-open 69.42 111.0 24.3 less-open 69.72 101.5 45.9 less-open 69.95 281.3 28.0 less-open 70.03 97.0 30.2 less-open 70.4 90.4 59.0 less-open 70.95 102.0 50.4 less-open 70.97 290.9 32.5 less-open 71.99 99.7 49.8 less-open 72.15 341.3 81.2 less-open 72.32 88.9 54.5 less-open 72.65 101.9 51.8 less-open 72.67 269.8 31.1 less-open 72.92 94.6 39.3 less-open 73.31 104.7 53.3 less-open 73.32 323.8 44.1 less-open 73.53 66.1 51.0 less-open 73.79 92.5 41.0 less-open 74.28 107.1 51.3 less-open 74.37 100.8 47.3 less-open 74.6 314.1 68.0 less-open 75.33 97.0 41.8 less-open 75.36 211.1 63.0 less-open 75.46 110.9 39.9 less-open 75.57 122.7 38.2 less-open 75.79 100.7 51.2 less-open 76.21 101.3 44.8 less-open 76.33 105.6 45.6 less-open 76.96 95.9 47.4 less-open 77.13 90.5 60.4 less-open 77.65 100.3 45.5 less-open 77.88 79.2 51.1 less-open 78.05 319.7 63.4 less-open 78.07 104.6 50.7 less-open Page 4 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 78.58 245.5 32.7 less-open 78.69 256.2 32.1 less-open 78.79 244.7 33.6 less-open 78.95 249.8 37.1 less-open 79.4 231.6 49.1 less-open 79.44 309.4 49.0 less-open 79.54 101.2 55.0 less-open 79.89 218.7 63.0 less-open 80.26 128.0 50.4 less-open 80.52 99.1 52.9 less-open 80.58 335.5 72.1 less-open 80.75 194.3 36.4 less-open 81.68 333.1 78.0 less-open 83.34 160.9 36.1 less-open 84.36 148.0 44.6 less-open 84.37 307.4 70.5 less-open 84.46 331.5 63.6 less-open 84.95 94.5 44.7 less-open 85.13 158.3 15.7 less-open 85.31 201.6 36.5 less-open 85.45 315.6 19.8 less-open 85.69 213.3 9.6 less-open 86.14 150.27 78.24 less-open 86.31 261.63 34.99 less-open 86.98 89.5 62.9 less-open 87.16 265.1 47.0 open 87.19 95.7 56.7 less-open 87.64 159.2 80.2 open 87.85 312.1 35.8 less-open 88.37 164.5 74.7 open 89.71 139.9 73.7 open 89.86 166.0 73.1 open 90.21 162.5 34.9 less-open 90.56 169.1 58.2 less-open 90.67 155.4 45.2 less-open 91.76 339.7 80.2 less-open 91.76 135.4 65.9 open 92.43 147.6 66.0 open 92.49 344.8 60.5 open 92.88 130.2 61.4 open 93.11 178.9 62.4 open 93.72 167.6 70.2 less-open 94.16 164.5 69.1 less-open 94.84 139.7 51.5 open Page 5 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 95 289.52 81.78 open 95.17 153.6 70.0 less-open 95.45 151.6 67.8 less-open 96.8 124.73 82.15 open 97.09 1.7 43.5 open 97.49 315.0 43.7 open 97.71 300.8 50.0 less-open 98.09 306.7 40.0 less-open 98.31 291.1 33.8 less-open 98.51 331.4 79.6 less-open 98.53 286.5 33.8 less-open 98.7 246.0 48.0 less-open 99.03 241.6 28.7 less-open 99.19 161.9 75.8 less-open 99.4 248.4 49.3 less-open 99.65 305.6 31.7 less-open 99.83 269.7 25.6 less-open 100.14 255.2 36.7 less-open 100.31 97.0 41.7 less-open 100.84 260.5 28.9 less-open 100.93 155.3 64.5 less-open 101.62 323.7 77.3 less-open 101.8 316.2 44.8 less-open 102.05 312.0 46.9 less-open 102.34 274.9 28.5 less-open 102.95 195.1 51.1 less-open 103.65 154.2 60.3 less-open 103.7 261.8 34.8 less-open 104.08 109.93 49.01 less-open 104.64 253.58 31.29 less-open 104.73 243.4 36.9 less-open 105.1 68.3 69.1 less-open 105.45 98.3 54.4 less-open 106.07 311.6 46.5 less-open 107.43 306.0 43.6 less-open 108.01 278.8 36.6 less-open 110.53 319.0 51.6 less-open 110.61 320.0 44.9 less-open 110.67 320.0 52.4 less-open 112.57 263.36 33.15 less-open 113.73 344.04 58.34 less-open 113.74 252.12 31.8 less-open 114.13 350.58 31.52 less-open 114.32 137.01 64.52 less-open Page 6 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 114.53 274.06 27.43 less-open 115.43 253.24 30.36 less-open 115.87 95.72 62.81 less-open 116.6 139.87 65.13 less-open 117.6 146.1 61.22 less-open 117.85 160.56 61.64 less-open 117.87 258.22 31.98 less-open 118.6 216.1 43.4 less-open 119.11 288.79 31.64 less-open 119.37 121.55 59.66 less-open 119.84 314.73 33.02 less-open 120.11 97.44 72.18 less-open 120.27 311.77 36.3 less-open 120.71 316.07 36.53 less-open 120.99 314.29 28.93 less-open 121.06 114.79 58.17 less-open 121.37 325.61 37.73 less-open 121.59 137.4 65.71 less-open 121.83 292.8 55.32 less-open 122.97 316.23 64.58 less-open 124.04 326.69 37.69 open 124.44 104.86 65.55 less-open 124.75 298.26 48.02 less-open 124.99 103.52 62.67 less-open 125.24 120.19 60.36 less-open 125.45 121.65 60.88 less-open 125.58 103.59 61.89 less-open 125.71 114.58 65.9 less-open 126 127.51 53.02 less-open 126.38 113.83 60.37 less-open 126.62 122.56 56.86 less-open 126.73 117.71 55.11 less-open 126.89 122.66 65.44 less-open 127.06 94.3 49.84 less-open 127.44 121.63 54.99 less-open 127.49 339.35 81.93 less-open 127.69 139.26 61.23 less-open 127.88 134.59 53.84 less-open 128.15 137.43 56.86 less-open 128.55 135.86 60.24 less-open 129.15 107.96 55.03 less-open 129.73 112.9 54.93 less-open 130.1 116.18 47.05 less-open 130.27 282.59 65.52 less-open Page 7 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 130.51 116.82 56.56 less-open 131.23 300.7 59.97 less-open 131.66 119.68 58.83 less-open 133.15 106.33 58.99 less-open 133.36 102.79 74.86 less-open 133.38 103.52 59.27 less-open 133.91 105.11 61.26 less-open 134.06 109.88 60.85 less-open 134.3 112.33 57.91 less-open 134.37 346.22 82.76 less-open 134.45 110.86 58.15 less-open 134.82 103.53 54.67 less-open 136.59 293.56 35.63 less-open 136.77 107.88 59.84 less-open 137.48 117.24 59.87 less-open 137.51 214.7 35.92 less-open 137.98 114.83 59.32 less-open 138.02 338.68 41.3 less-open 138.11 329.41 49.84 less-open 138.2 116.27 54.34 less-open 138.37 117.06 57.88 less-open 139.52 127.22 48.78 less-open 139.96 105.12 61.48 less-open 140.22 255.56 39.02 less-open 140.73 277.76 12.19 less-open 140.76 274.08 15.38 less-open 142.05 282.23 20.24 less-open 142.92 350.42 30.4 less-open 143.3 316.45 30.54 less-open 143.73 81.93 39.87 less-open 144.08 119.88 60.02 less-open 144.36 106.92 50.78 less-open 144.94 260.66 37.76 less-open 146.06 255.39 42.3 less-open 146.07 124.13 65.09 less-open 146.92 115.71 60.8 less-open 147.26 319.9 51.04 less-open 147.83 124.7 54.58 less-open 148.14 112.31 60.59 less-open 148.47 330.59 65.8 less-open 148.77 116.25 58.39 less-open 149.09 114.78 60.42 less-open 149.22 106.13 65.22 less-open 149.64 116.23 59.94 less-open Page 8 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 150.34 106.99 59.72 less-open 151.25 109.84 59.43 less-open 151.37 112.33 57.71 less-open 151.64 122.62 58.33 less-open 151.91 111.62 39.26 less-open 152.17 98.68 60.91 less-open 153.02 334.34 52.01 less-open 153.16 117.27 61.38 less-open 153.47 121.62 63.63 less-open 153.66 118.75 64.78 less-open 154.4 130.48 60.1 less-open 154.4 353.57 43.1 less-open 154.62 127.18 57.43 less-open 154.76 104.09 67.8 less-open 154.85 124.56 65.62 less-open 155.01 103.18 53.16 less-open 155.09 343.8 50.71 less-open 155.2 116.29 57.05 less-open 156.03 350.76 43.44 less-open 156.69 348.73 47.92 less-open 156.85 337.43 40.13 less-open 157.09 351.56 53.05 less-open 157.62 342.85 53.98 less-open 158.24 131.99 58.32 less-open 159.36 294.35 28.72 less-open 159.67 131.91 58.9 less-open 160.18 124.08 57.21 less-open 160.22 342.65 52.51 less-open 161.54 128.07 54.83 less-open 161.7 124.38 56.83 less-open 161.93 142.26 43.55 less-open 162.15 107.97 66.86 less-open 162.68 350.1 47.24 less-open 162.69 124.02 65.53 less-open 162.94 325.41 61.76 less-open 163.26 342.33 43.27 less-open 163.49 351.46 54.91 less-open 163.86 332.9 40.56 less-open 163.98 305.8 44.52 less-open 164.13 140.85 58.56 less-open 164.37 342.46 39.91 less-open 164.6 122.62 53.51 less-open 164.95 139.88 49.65 less-open 165.21 131.9 48.54 less-open Page 9 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 165.45 144.99 53.61 less-open 166.06 82.48 51.05 less-open 166.6 69.69 55.95 less-open 166.98 108.49 68.11 less-open 168.52 136.96 64.22 less-open 168.82 237.18 33.63 less-open 168.92 133.44 70.67 less-open 169.65 279.07 27.48 less-open 170.45 107.96 63.68 less-open 170.84 92.7 61.18 less-open 171.09 128.76 54.02 less-open 171.39 108.42 60.73 less-open 171.76 287.77 60.83 less-open 171.98 263.41 23.64 less-open 172.56 295.17 28.02 less-open 173.05 351.76 34.68 less-open 173.74 112.22 69.34 less-open 174.05 129.07 57.49 less-open 174.76 26.99 38.98 less-open 175.57 24.15 39.51 less-open 175.65 278.15 60.07 less-open 175.77 314.81 61.53 less-open 175.94 346.81 51.68 less-open 177.35 9.14 33.44 less-open 177.47 319.98 31.74 less-open 177.81 349.83 62.33 less-open 178.29 319.35 62.48 less-open 179.02 106.98 60.95 less-open 179.24 99.37 61.16 less-open 180.05 243.82 32.39 less-open 181.5 317.12 15.72 less-open 181.94 50.37 45.09 less-open 182.03 245.15 34.86 less-open 182.65 94.26 67.91 less-open 182.87 260.05 43.53 less-open 182.98 356.15 75.44 less-open 183.9 343.91 65.59 less-open 184.13 260.33 76.33 less-open 184.15 347.41 68.25 less-open 185.77 318.7 40.4 less-open 186.13 73.7 41.56 less-open 186.35 226.61 44.51 less-open 186.96 118.81 58.6 less-open 187.67 100.64 66.57 less-open Page 10 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 188.52 109.8 64.59 less-open 189.02 114.26 53.4 less-open 189.31 69.75 34.35 less-open 189.7 56.5 34.53 less-open 190.61 342.45 78.68 less-open 191.63 349.37 89.46 less-open Page 11 of 11

Fracture Orientations Interpreted from MW-65 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw65i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 38.18 236.7 20.7 less-open 38.34 145.7 46.5 less-open Note that down-dip compass azimuth 38.86 147.3 59.9 less-open is perpendicular to the strike direction.

38.99 331.5 83.1 less-open 40.82 351.6 70.3 less-open Note that interpreted down-dip compass 41.03 354.4 66.8 less-open azimuths are with respect to 42.35 297.4 80.3 less-open magnetic north.

42.51 139.7 46.7 less-open 42.70 137.8 32.0 less-open Down-dip azimuths & dip angles were 42.90 124.3 36.2 less-open corrected for borehole deviation from 43.19 163.5 27.3 less-open vertical.

43.47 290.7 69.0 less-open 43.73 145.0 46.6 less-open 44.15 130.4 43.3 less-open 44.65 125.7 32.2 open 45.01 152.0 44.4 less-open 45.10 130.0 21.2 less-open 45.34 177.3 82.5 less-open 45.58 144.5 46.7 less-open 46.63 132.8 42.0 less-open 46.90 145.7 38.5 less-open 47.13 159.5 50.4 less-open 47.61 175.0 82.7 less-open 48.46 132.6 40.1 less-open 51.70 133.0 45.7 less-open 52.01 146.9 44.8 less-open 52.15 186.6 31.2 less-open 52.34 350.6 77.7 less-open 53.61 132.0 44.4 less-open 55.55 126.7 51.6 less-open 56.32 310.0 77.7 less-open 56.64 137.1 51.6 less-open 58.01 101.9 55.1 less-open 59.26 75.2 46.8 less-open 60.32 232.8 28.4 less-open 61.57 248.0 18.6 less-open 64.21 286.3 54.4 less-open 65.18 190.3 19.9 less-open 66.22 293.0 24.2 less-open 66.66 80.0 36.2 less-open 68.54 181.9 77.9 less-open 69.51 90.1 36.1 less-open 70.58 68.0 28.7 less-open 70.89 82.0 29.8 less-open Page 1 of 2

Fracture Orientations Interpreted from MW-65 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw65i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 71.09 45.9 40.6 less-open 71.56 293.7 38.0 less-open 71.92 343.7 62.8 less-open 78.01 108.8 76.7 less-open 79.38 275.6 32.1 less-open Page 2 of 2

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 38.15 354.8 22.8 open 38.35 336.5 28.3 open Note that down-dip compass azimuth 39.06 308.3 13.5 less-open is perpendicular to the strike direction.

39.83 332.3 30.0 open 40.18 281.5 19.9 less-open Note that interpreted down-dip compass 40.40 180.8 63.0 less-open azimuths are with respect to 40.52 328.2 16.2 less-open magnetic north.

41.46 309.0 41.9 less-open 41.79 197.6 77.0 less-open Down-dip azimuths & dip angles were 41.81 167.1 76.5 less-open corrected for borehole deviation from 41.98 314.6 32.6 less-open vertical.

42.17 280.7 29.9 less-open 43.15 4.9 23.3 open 43.27 184.9 75.5 less-open 43.75 189.6 61.9 open 44.00 191.1 66.1 open 44.19 185.5 66.4 less-open 44.82 213.2 69.9 less-open 44.86 202.1 36.7 less-open 45.88 149.2 31.4 less-open 46.24 321.8 56.2 less-open 46.27 232.6 32.9 less-open 46.59 291.5 42.1 less-open 46.97 131.7 37.5 less-open 47.38 159.3 32.7 less-open 47.44 153.5 29.9 less-open 47.68 338.6 38.4 less-open 47.96 325.2 55.0 open 48.39 177.9 81.5 less-open 48.54 21.4 78.2 less-open 49.07 185.1 32.3 less-open 49.67 146.4 19.0 less-open 49.78 190.7 42.5 open 50.32 345.5 33.6 less-open 50.61 341.1 24.7 open 51.15 134.4 76.5 less-open 51.34 132.2 48.6 less-open 52.95 121.8 57.4 less-open 53.58 110.6 47.7 less-open 53.68 225.2 70.3 open 54.66 345.6 28.8 less-open 54.99 287.8 34.2 less-open 56.72 324.2 52.4 less-open 57.44 96.3 76.7 less-open Page 1 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 58.45 86.7 82.3 less-open 59.46 91.1 83.0 less-open 59.75 244.8 74.1 less-open 61.20 316.6 29.3 less-open 61.56 288.9 24.5 less-open 63.81 209.5 53.9 less-open 64.52 118.5 45.1 less-open 65.84 128.2 50.1 less-open 66.17 98.8 28.4 less-open 66.20 259.5 70.3 less-open 66.39 134.4 37.8 less-open 69.24 191.0 56.9 less-open 70.05 116.98 45.29 less-open 71.3 271.1 82.12 less-open 72.28 85.1 28.4 less-open 73.02 269.9 77.3 less-open 74.39 346.8 29.7 less-open 74.85 178.1 74.2 less-open 75.92 189.6 82.3 less-open 81.78 124.0 39.9 less-open 82.61 356.2 80.1 less-open 84.24 193.9 41.2 less-open 85.01 177.4 79.2 less-open 85.30 178.0 80.9 less-open 86.06 186.1 55.1 less-open 86.61 192.8 57.9 less-open 87.23 174.3 67.5 less-open 87.92 189.1 65.9 less-open 88.08 176.6 72.9 less-open 88.59 189.9 79.5 less-open 89.39 157.2 77.5 less-open 89.59 165.4 82.0 less-open 90.41 170.5 77.0 less-open 90.69 152.1 71.0 less-open 90.97 168.4 76.7 less-open 92.04 163.5 84.6 less-open 93.29 169.6 81.9 less-open 94.19 169.6 83.6 less-open 94.86 162.7 26.5 less-open 95.13 160.7 42.0 less-open 96.44 179.8 79.1 less-open 96.45 51.6 16.1 less-open 100.43 292.4 59.7 less-open 100.92 179.91 78.76 less-open Page 2 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 101.1 111.7 55.83 less-open 101.87 322.5 63.2 less-open 101.92 174.9 76.3 less-open 103.15 130.6 42.7 less-open 103.49 127.9 51.0 less-open 104.35 337.9 35.9 less-open 108.02 178.9 78.9 less-open 108.03 5.0 38.8 less-open 109.47 189.2 42.4 less-open 110.60 29.7 70.5 less-open 111.91 214.8 54.0 less-open 112.63 348.9 65.7 less-open 112.76 351.9 62.2 less-open 112.80 73.1 47.3 less-open 113.18 170.8 77.8 less-open 113.89 191.5 72.2 less-open 114.01 188.5 75.5 less-open 114.77 172.1 86.0 less-open 115.82 182.8 75.5 less-open 116.06 183.8 75.7 less-open 116.66 180.3 78.7 less-open 117.61 305.0 31.3 open 117.88 336.1 38.3 less-open 118.17 216.6 50.1 less-open 119.53 232.5 61.9 less-open 120.57 353.8 56.5 less-open 121.42 334.0 58.6 less-open 122.12 189.7 40.4 less-open 122.97 208.5 51.6 less-open 123.23 354.9 58.1 less-open 126.72 355.7 36.0 less-open 127.43 350.5 51.2 less-open 127.94 343.9 40.5 less-open 128.25 338.6 39.6 less-open 129.69 341.0 55.6 less-open 130.05 333.5 60.8 less-open 130.16 205.0 53.1 less-open 130.62 279.6 46.0 less-open 130.97 213.0 38.7 less-open 131.21 282.1 43.0 less-open 131.38 203.5 46.4 less-open 131.84 204.2 51.8 less-open 131.88 351.7 75.8 less-open 132.13 210.0 53.2 less-open Page 3 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 132.66 341.5 45.3 less-open 132.69 15.59 76.88 less-open 132.77 325.59 42.93 less-open 132.88 329.9 42.2 less-open 133.42 338.9 29.2 less-open 133.81 311.5 58.5 less-open 133.85 10.0 59.8 less-open 134.61 94.9 74.5 less-open 134.76 205.9 36.9 less-open 135.04 302.0 37.3 less-open 135.47 334.0 51.8 less-open 135.71 326.7 41.4 less-open 135.87 286.93 44.93 less-open 135.88 157.81 54.39 less-open 136.39 327.9 51.9 less-open 136.64 313.0 34.9 less-open 136.82 301.1 44.4 less-open 137.43 296.8 40.8 less-open 137.5 291.8 36.0 less-open 137.55 257.6 20.7 less-open 137.68 171.1 63.8 less-open 137.79 296.7 37.3 less-open 138.22 325.4 48.7 less-open 138.45 337.4 52.3 less-open 138.71 185.1 31.5 less-open 138.98 200.0 45.3 less-open 139.16 213.2 41.8 less-open 139.36 167.4 43.8 less-open 139.86 308.2 67.9 less-open 139.96 205.0 56.6 less-open 140.9 312.3 72.7 less-open 141.11 336.7 23.1 less-open 141.74 303.2 36.2 less-open 141.86 109.2 55.4 less-open 141.88 283.6 39.8 less-open 142.72 124.3 58.4 less-open 143.02 320.6 61.8 less-open 143.5 240.7 59.4 less-open 143.56 303.9 75.5 less-open 143.58 316.2 56.3 less-open 144.04 115.3 55.9 less-open 144.76 114.2 62.8 less-open 144.85 297.7 44.0 less-open 145.44 310.9 53.7 less-open Page 4 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 145.44 123.2 48.6 less-open 146.66 336.8 54.8 less-open 146.93 328.9 48.6 less-open 147.24 158.9 42.2 less-open 148.77 109.2 71.4 less-open 148.99 102.0 56.1 less-open 149.16 107.5 57.2 less-open 149.3 101.9 51.8 less-open 150.56 123.2 61.4 less-open 150.78 102.6 51.0 less-open 151.33 230.5 70.3 less-open 152.83 143.0 38.0 less-open 154.53 115.0 57.1 less-open 155.03 109.2 63.4 less-open 155.39 106.6 65.8 less-open 155.81 112.0 62.6 less-open 156.19 299.6 24.6 less-open 156.45 332.2 30.3 less-open 157.03 120.1 55.8 less-open 157.16 321.8 34.9 less-open 157.75 355.6 54.1 less-open 158.47 144.1 55.2 less-open 158.7 349.9 57.6 less-open 159.02 329.3 41.8 less-open 159.95 343.6 50.2 less-open 159.95 109.2 44.1 less-open 160.58 213.3 50.4 less-open 161.16 288.4 36.4 less-open 161.73 299.8 29.9 less-open 163.11 104.2 43.9 less-open 163.45 107.98 40.85 less-open 163.89 353.09 41.88 less-open 164.15 104.5 68.5 less-open 164.26 108.0 58.1 less-open 164.37 108.8 60.0 less-open 164.61 349.9 54.0 less-open 164.67 347.8 47.1 less-open 165.88 316.6 44.0 less-open 166.51 168.5 81.1 less-open 166.53 322.0 42.7 less-open 167.67 327.1 36.9 less-open 167.79 313.4 42.2 less-open 167.81 202.2 71.1 less-open 168.7 230.2 71.6 less-open Page 5 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 169.15 219.3 63.1 less-open 170.67 335.1 51.5 less-open 170.94 8.6 56.6 less-open 171.24 318.0 60.3 less-open 173.63 344.2 50.8 less-open 174.63 322.0 44.6 less-open 175.1 44.3 70.2 less-open 175.73 324.8 52.4 less-open 175.98 101.1 61.0 less-open 176.02 283.3 38.1 less-open 176.57 102.0 56.8 less-open 177.31 332.2 59.9 less-open 178.31 322.9 50.4 less-open 179.3 326.3 41.4 less-open 179.86 132.4 60.1 less-open 180.13 308.3 41.7 less-open 180.66 125.4 60.0 less-open 180.83 333.1 57.7 less-open 180.88 126.4 56.0 less-open 183 185.2 76.0 less-open 184.01 295.5 45.6 less-open 184.85 126.2 41.8 less-open 187.41 302.4 42.6 less-open 187.94 302.9 52.6 less-open 189.36 331.7 76.7 less-open 189.65 287.1 32.8 less-open 190.39 127.7 37.7 less-open 190.45 328.1 48.4 less-open 190.72 338.7 45.3 less-open 191.53 289.8 29.6 less-open 195.62 62.9 73.9 less-open 197.85 124.3 51.9 less-open 198.36 309.1 88.6 less-open 198.79 311.6 86.7 less-open Page 6 of 6

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 32.54 251.1 60.4 less-open 33.17 346.9 72.1 less-open Note that down-dip compass azimuth 33.71 309.7 72.5 open is perpendicular to the strike direction.

33.80 297.4 53.4 less-open 34.14 188.2 71.4 less-open Note that interpreted down-dip compass 34.32 189.6 72.9 less-open azimuths are with respect to 34.76 272.8 51.7 less-open magnetic north.

34.77 82.1 73.7 less-open 35.05 19.9 19.8 less-open Down-dip azimuths & dip angles were 35.09 171.0 62.3 less-open corrected for borehole deviation from 35.15 282.2 47.2 less-open vertical.

35.29 192.5 70.5 less-open 35.74 292.3 27.8 open 37.07 319.2 68.9 less-open 37.13 284.4 46.7 less-open 37.13 291.7 29.6 less-open 37.59 68.8 44.4 less-open 37.60 274.1 50.6 less-open 38.06 137.9 51.0 less-open 38.27 255.9 54.9 less-open 38.75 257.1 33.2 less-open 39.27 206.6 45.7 less-open 40.58 309.6 43.7 open 41.15 167.4 23.4 less-open 41.29 204.8 71.4 open 41.52 161.3 41.0 less-open 41.59 316.2 39.9 less-open 41.74 171.9 65.0 less-open 41.75 212.8 75.7 less-open 42.03 207.9 72.5 less-open 42.31 245.0 52.8 less-open 42.43 139.8 69.4 less-open 42.57 240.9 45.8 less-open 42.57 319.9 67.2 less-open 42.66 225.3 30.7 less-open 43.12 275.1 37.3 open 43.58 231.6 39.3 less-open 43.72 165.5 60.3 less-open 43.89 179.7 77.9 less-open 44.33 245.3 33.9 less-open 44.38 150.3 43.8 less-open 44.60 231.7 78.2 less-open 44.90 281.3 24.1 less-open 45.77 134.8 27.6 less-open Page 1 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 46.53 122.7 69.9 less-open 46.56 145.4 68.4 less-open 48.20 202.0 69.5 less-open 48.63 208.3 65.9 less-open 48.75 200.9 66.2 less-open 49.00 221.4 63.9 less-open 49.23 330.3 69.0 less-open 49.27 201.9 62.0 less-open 50.13 10.6 24.4 open 50.58 92.7 20.0 less-open 52.47 115.39 61.75 less-open 53.59 122.52 57.78 less-open 54.25 154.0 47.3 less-open 54.77 179.6 30.5 less-open 56.60 332.4 65.3 less-open 58.73 315.0 44.9 less-open 58.90 228.0 48.1 less-open 61.26 178.4 59.5 less-open 62.04 223.6 46.4 less-open 62.21 229.9 39.5 less-open 64.34 303.8 45.0 less-open 65.20 138.9 46.1 less-open 66.52 125.0 46.4 less-open 67.47 332.4 74.7 less-open 67.64 341.4 63.3 less-open 67.90 321.9 57.1 less-open 69.65 112.3 73.6 less-open 70.77 343.3 56.4 less-open 71.36 135.9 53.5 less-open 71.96 319.4 54.4 less-open 73.58 337.7 68.9 less-open 73.71 322.0 62.2 less-open 73.92 136.5 55.9 less-open 74.74 121.7 61.6 less-open 76.06 333.4 67.6 less-open 76.24 124.8 67.3 less-open 77.54 325.1 63.1 less-open 77.77 331.9 65.8 less-open 77.93 203.8 78.5 less-open 78.82 108.2 62.5 less-open 79.05 115.4 61.9 less-open 79.72 327.21 68.85 less-open 81.25 31.4 76.5 less-open 81.72 343.7 34.7 less-open Page 2 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 82.67 341.4 75.7 less-open 83.25 116.0 69.4 less-open 84.12 122.8 67.8 less-open 84.73 106.7 73.9 less-open 85.10 100.7 24.6 less-open 85.17 121.3 71.5 less-open 85.39 186.2 78.0 less-open 86.26 322.6 57.4 less-open 87.30 185.1 71.1 less-open 88.14 327.9 69.2 less-open 88.17 130.5 73.0 less-open 89.61 329.2 58.5 less-open 91.21 335.4 63.3 less-open 93.22 259.6 49.8 less-open 94.34 238.6 66.4 less-open 94.67 221.6 71.8 less-open 94.94 211.4 74.9 less-open 95.82 108.0 78.0 less-open 97.07 93.7 62.2 less-open 97.72 179.2 79.8 less-open 97.86 193.0 79.1 less-open 98.1 342.6 61.5 less-open 99.51 39.1 35.3 less-open 99.54 182.4 75.1 less-open 100.58 5.2 24.3 less-open 101.27 8.2 35.4 less-open 101.78 228.3 48.4 less-open 102.46 196.0 40.9 less-open 102.47 345.6 69.8 less-open 102.85 201.5 25.8 less-open 103.38 117.7 51.3 less-open 103.47 131.3 45.9 less-open 103.75 350.9 73.6 less-open 104.23 164.8 46.5 less-open 104.59 215.5 61.3 less-open 104.68 347.3 66.5 less-open 105.26 352.8 55.8 less-open 105.27 344.2 74.3 less-open 106.01 323.1 71.8 less-open 106.13 244.3 53.3 open 106.46 119.5 76.6 less-open 106.69 183.5 81.7 less-open 107.03 334.9 70.6 less-open 107.18 124.36 64.36 less-open Page 3 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 107.4 336.82 70.01 less-open 107.62 209.9 56.7 less-open 108.31 350.6 65.0 open 108.36 191.6 30.4 less-open 108.48 208.4 44.4 less-open 109 173.4 26.5 less-open 109.37 352.5 66.1 less-open 109.55 121.3 34.7 less-open 109.72 118.3 68.1 less-open 110.42 28.6 5.7 less-open 110.53 49.31 9.32 less-open 112.27 354.12 75.52 less-open 112.28 312.0 65.8 less-open 112.68 350.2 71.1 less-open 112.99 345.8 72.3 less-open 113.18 343.0 67.1 less-open 113.24 215.8 40.8 less-open 114.56 348.5 61.7 less-open 115.13 155.4 32.3 less-open 115.27 334.0 64.3 less-open 115.99 140.2 52.0 less-open 116.04 304.8 63.3 less-open 116.04 342.4 62.4 less-open 116.8 331.8 56.1 less-open 117.03 334.3 46.8 less-open 117.2 322.6 38.5 less-open 118.85 315.5 58.3 less-open 120.13 325.0 51.6 less-open 120.85 76.0 64.2 less-open 121.48 74.9 65.1 less-open 121.97 105.4 64.5 less-open 122.32 353.7 80.5 less-open 122.56 211.3 74.7 less-open 122.97 109.4 74.0 less-open 123.33 359.1 52.1 less-open 124.1 315.0 48.4 less-open 124.52 187.6 72.6 less-open 124.66 302.8 63.6 less-open 125.41 306.4 38.3 less-open 125.5 309.1 41.3 less-open 125.64 168.7 38.3 less-open 125.86 105.7 64.6 less-open 127.43 349.8 40.4 less-open 128.1 224.6 70.5 less-open Page 4 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 130.01 341.1 31.3 less-open 130.59 178.3 69.5 less-open 130.71 316.6 37.1 less-open 130.83 177.1 71.2 less-open 131.18 167.6 75.9 less-open 131.76 182.6 69.5 less-open 133.27 173.7 71.0 less-open 134.59 16.9 37.1 less-open 135.11 176.5 75.4 less-open 135.36 346.1 35.5 less-open 136.09 183.1 74.4 less-open 136.51 176.0 74.4 less-open 136.6 333.7 47.3 less-open 136.83 191.7 70.3 less-open 137.64 185.2 69.8 less-open 137.85 184.4 68.3 less-open 138.38 244.4 66.6 less-open 138.95 240.5 57.3 less-open 140.07 169.7 70.7 less-open 140.49 203.9 13.8 less-open 140.99 197.0 48.1 less-open 141.34 204.2 45.2 less-open 141.81 10.2 63.8 less-open 142.07 113.5 49.1 less-open 142.37 2.8 80.3 less-open 143.37 356.8 80.7 less-open 144.77 344.6 52.0 less-open 145.31 340.5 48.9 less-open 146.19 336.8 74.42 less-open 147.42 135.33 51.39 less-open 148.03 134.6 51.9 less-open 148.44 116.6 54.8 less-open 148.94 133.5 46.8 less-open 149.37 108.1 44.7 less-open 149.49 320.3 40.9 less-open 149.57 141.1 48.1 less-open 149.82 126.1 57.0 less-open 150.44 306.0 49.1 less-open 150.84 186.8 47.4 less-open 154.45 340.5 42.8 less-open 156.42 191.3 35.2 less-open 156.77 175.9 54.7 less-open 157.68 0.9 73.1 less-open 158.63 188.0 53.7 less-open Page 5 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 158.92 346.9 72.0 less-open 159.12 226.3 38.8 less-open 159.52 210.9 58.1 less-open 159.79 268.3 26.6 less-open 159.92 253.8 27.5 less-open 160.54 123.3 56.8 less-open 160.83 109.0 58.7 less-open 160.83 181.5 77.7 less-open 160.83 292.0 29.0 less-open 160.97 193.5 67.0 less-open 161.46 199.2 54.1 less-open 161.73 198.1 64.2 less-open 161.82 218.8 57.8 less-open 161.99 129.5 68.0 less-open 162.3 109.2 57.9 less-open 163.27 171.6 77.0 less-open 163.87 338.6 26.7 less-open 164.42 172.0 24.1 less-open 165.78 169.0 30.8 less-open 166.02 283.5 60.5 less-open 166.38 3.1 56.2 less-open 166.47 179.7 49.2 less-open 167.12 225.4 52.6 less-open 167.9 171.0 57.9 less-open 168.36 233.4 45.9 less-open 168.86 9.3 35.6 less-open 170.74 347.1 75.4 less-open 171.11 291.1 26.1 less-open 173.3 311.9 69.7 less-open 173.37 99.3 68.7 less-open 174.02 291.8 68.5 less-open 174.84 288.8 69.9 less-open 175.07 1.78 46.13 less-open 175.4 96.71 66.18 less-open 175.8 97.8 64.9 less-open 176.32 286.0 79.0 less-open 176.37 104.9 48.6 less-open 176.71 99.0 51.6 less-open 176.75 297.4 55.8 less-open 177.1 299.5 82.6 less-open 178.98 130.4 26.6 less-open 179.14 204.5 24.2 less-open 179.62 129.1 59.6 less-open 180.05 110.45 64.54 less-open Page 6 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 180.14 113.2 64.5 less-open 180.98 100.55 61.17 less-open 181.27 104.26 35.35 less-open 181.47 115.67 72.62 less-open 182.81 313.72 58.29 less-open 183.4 324.21 76.37 less-open 184.36 294.02 63.7 less-open 184.66 331.65 74.92 less-open 186.3 329.3 59.12 less-open 187.1 111.22 69.92 less-open 187.45 323 54.33 less-open 188.04 326.34 39.07 less-open 188.4 145.95 42.86 less-open 188.51 325.8 33.15 less-open 188.78 93.75 67.49 less-open 190.61 128.68 70.64 less-open 190.63 124.39 64.52 less-open 190.83 348.16 69.86 less-open 191.14 304.9 44.31 less-open 192.68 115.36 49.55 less-open 192.71 300.78 54.16 less-open 193 108.94 53.4 less-open 193.18 126.62 62.27 less-open 193.4 112.41 66.14 less-open 193.67 102.94 66.99 less-open 193.98 100.61 61.3 less-open 194.33 329.91 64.28 less-open 194.84 106.59 64.38 less-open 195.16 297.94 67.89 less-open 195.27 107.19 60.91 less-open 196.97 335.89 41.99 less-open 197.37 334.78 51.7 less-open 197.93 4.69 65.65 less-open 198.49 327.17 66.62 less-open 198.82 345.72 58.97 less-open 198.99 324.32 55.1 less-open 199.33 307.22 56.71 less-open 201.26 331.48 43.72 less-open 203.52 341.76 66.03 less-open 203.65 330.43 67.69 less-open 204.51 326.22 42.42 less-open 206.48 341.55 60.23 less-open 206.88 331.01 55.49 less-open 207.55 317.44 29.34 less-open Page 7 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 207.72 314.89 46.24 less-open 207.83 6.66 39.9 less-open 208.58 348.9 40.4 less-open 208.71 349.28 38.4 less-open 209.24 334.4 60.54 less-open 212.04 225.55 72.68 less-open 212.81 140.24 58.69 less-open 213.09 339.84 61.08 less-open 213.27 335.45 63.39 less-open 213.5 343.13 55.3 less-open 214 351.87 47.84 less-open 214.28 341.34 55.32 less-open 214.77 4.92 55.47 less-open 216.96 10.21 67.31 less-open 218 322.02 69.09 less-open 218.57 342.81 68.05 less-open 219.58 223.95 52.5 less-open 220.28 338.13 58.73 less-open 220.41 329.03 61.11 less-open 220.7 324.84 55.53 less-open 221.23 323.59 55.11 less-open 221.64 321.08 42.12 open 222.15 330.46 38.41 less-open 222.83 312.19 49.43 less-open 222.94 330.19 49.1 less-open 222.99 313.91 47.21 less-open 223.16 256.86 9.07 less-open 223.71 335.55 65.01 less-open 224.72 25.4 32.49 less-open 225.59 128.46 53.91 less-open 226.14 190.24 60.82 less-open 226.28 107.06 45.9 less-open 226.77 117.51 26.6 less-open 226.85 305.23 35.88 less-open 227.02 118.67 56.89 less-open 227.78 162.25 68.4 less-open 227.9 129.83 40.18 less-open 228.61 222.04 66.65 less-open 229.48 120.05 48.11 less-open 230.58 238.4 81.26 less-open 230.6 160.82 60.93 less-open 231.31 256.82 71.24 less-open 231.35 306.5 30.05 less-open 231.55 193.1 31.97 less-open Page 8 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 233.46 102.97 49.58 less-open 233.57 330.04 57.59 less-open 234.85 124.92 59.51 less-open 235.75 127.27 45.84 less-open 235.96 352.45 65.23 less-open 236.92 281.92 19.01 less-open 237.66 116.75 55.68 less-open 238 118.21 50.12 less-open 238.46 295.47 43.36 less-open 239.9 341.54 61.1 less-open 240.35 26.33 73.9 less-open 244.22 140.43 49.32 less-open 244.39 332.41 71.72 less-open 244.72 43.47 30.31 less-open 244.86 298.98 29.98 less-open 245.15 121.34 42.7 less-open 245.4 124.97 52.18 less-open 245.69 114.34 52.67 less-open 245.9 119.2 52.2 less-open 246.03 119.2 52.14 less-open 246.62 121.77 56.09 less-open 247.7 329.25 66.69 less-open 248.07 111.64 42.2 less-open 249.33 338.82 58.63 less-open 250.03 338.23 56.9 less-open 250.1 340.16 57.78 less-open 250.31 341.31 52.17 less-open 250.61 355.65 62.41 less-open 250.79 333.56 50.58 less-open 250.97 347.82 59.71 less-open 251.21 346.66 56.54 less-open 252.2 355.82 62.4 less-open 252.28 4.83 59.16 less-open 252.51 109.46 44.65 less-open 252.56 116.17 51.66 less-open 252.88 324.65 33.13 less-open 253.2 344.67 53.97 less-open 253.58 349.67 54.17 less-open 253.7 108.44 42.94 less-open 253.96 95.13 40.23 less-open 254.18 190.25 38.88 less-open 254.33 106.5 31.86 less-open 254.4 294.77 58.97 less-open 254.55 285.04 49.66 less-open Page 9 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 254.61 106.52 37.12 less-open 254.96 110.09 28.37 less-open 255.2 99.62 39.6 less-open 255.24 343.52 68.83 less-open 255.56 352.44 68.07 less-open 256.09 105.44 41.56 less-open 257.1 112.27 45.91 less-open 257.3 351.26 76.53 less-open 257.44 97.05 34.35 less-open 258.58 188.99 84.17 less-open 259.28 113.01 62.31 less-open 259.92 354.62 77.79 less-open 260.82 354.71 77.56 less-open 261.25 352.49 80.01 less-open 261.43 109.94 67 less-open 261.58 357.47 76.58 less-open 262.6 354.53 83.34 less-open 262.71 328.47 34.86 less-open 262.77 333.42 28.6 less-open 262.92 316.43 27.58 less-open 263.21 109.44 46.47 less-open 263.55 304.16 59.64 less-open 264.85 119.73 50.52 less-open 265.04 116.22 48.51 less-open 265.3 117.35 60.48 less-open 265.51 349.33 78.79 less-open 265.82 115.72 47.01 less-open 266.2 346.61 72.49 less-open 266.31 322.38 58.28 less-open 266.71 73.22 60.38 less-open 267 61.38 62.1 less-open 267.69 122.42 48.71 less-open 267.88 65.82 76.42 less-open 268.32 334.82 62.39 open 268.48 321.8 57.88 less-open 268.68 330.71 70.06 less-open 269.16 342.06 67.28 less-open 269.28 341.3 62.55 less-open 269.57 121 46.42 less-open 269.91 111.37 62.53 less-open 269.99 341.17 74.91 less-open 270.34 132.53 46.04 less-open 270.5 321.55 54.74 less-open 270.96 32.23 24.54 less-open Page 10 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 271.77 333.34 55.66 less-open 272.43 120.11 48.41 less-open 273.19 316.51 39.86 less-open 274.02 172.61 75.74 less-open 274.82 170.35 44.48 less-open 275.32 123.78 39.27 less-open 275.5 133.52 52.64 less-open 276.26 311.15 44.95 less-open 276.36 309.79 40.68 less-open 276.47 311.22 51.82 less-open 276.75 316.57 37.79 open 276.89 319.77 37.09 less-open 277.73 182.23 56.4 less-open 277.99 346.04 74.18 less-open 278.4 347 70.77 less-open 278.57 224.02 20.46 less-open 279.91 324.13 42.46 open 280.01 143.87 42.13 less-open 280.34 133.51 39.91 less-open 280.82 148.22 46.88 less-open 280.95 138.04 44.54 less-open 281.18 142.02 44.93 less-open 281.73 124.93 44.4 less-open 282.15 330.66 48.8 less-open 282.72 346.89 66.37 less-open 282.77 324.08 36.31 less-open 282.88 126.34 56.23 less-open 283.98 288.8 22.41 less-open 285.37 339.67 61.38 less-open 286.52 298.28 68.16 less-open 287.64 283.55 24.78 less-open 287.9 296.84 73.64 less-open 288.15 139.56 40.09 less-open 288.23 124 38.51 less-open 288.23 307.26 72.25 less-open 288.33 144.78 41.82 less-open 288.47 128 53.19 less-open 288.66 112.43 55.52 less-open 290.53 303.72 79.05 less-open 290.72 309.21 58.71 less-open 291.17 306.01 46.3 less-open 291.5 313.58 39.27 less-open 292.38 327.15 51.84 less-open 293.27 267.07 75.88 less-open Page 11 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 293.35 348.8 44.17 less-open 294.94 303.29 33.74 less-open 295.94 286.86 30.32 less-open 296.75 295.71 44.93 less-open 298.89 94.5 57.99 less-open 301.24 114.52 36.62 less-open 301.28 140.69 45.56 less-open 301.53 112.5 52.03 less-open 301.99 76.34 65.3 less-open 302.53 348.53 45.5 less-open 302.62 101.83 50.54 less-open 302.63 338.76 50.85 less-open 302.78 131.4 30.04 less-open 302.89 326.77 51.97 less-open 302.98 326.01 54.75 less-open 303.06 99.07 55.62 less-open 303.23 105.66 48.9 less-open 303.36 326.15 52.41 less-open 303.63 333.18 55.53 less-open 303.78 306.16 34.56 less-open 303.96 127.25 49.87 less-open 304.42 337.37 23.63 less-open 304.43 119.96 52.43 less-open 304.57 120.81 47.62 less-open 304.7 100.84 57.37 less-open 304.75 146.97 34.46 less-open 304.77 323.9 36.73 less-open 305.12 123.36 47.54 less-open 305.52 331.02 53.53 less-open 306.65 325.5 50.83 less-open 308.35 170.02 48.13 less-open 308.74 316.59 53.17 less-open 308.86 110.12 41.37 less-open 309.23 337.69 67.75 less-open 309.64 306.86 63.02 less-open 310.28 123.5 45.9 less-open 311.91 125.65 45.35 less-open 313.23 172.72 43.66 less-open 313.41 194.1 52.02 less-open 313.81 133.97 45.58 less-open 315.1 178.69 42.09 less-open 315.62 156.26 45.65 less-open 316.36 116.02 44.64 less-open 316.66 121.77 36.29 less-open Page 12 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 318.2 264.89 26.31 less-open 321.7 345.84 75.33 less-open 322.52 326.26 64.07 less-open 324.79 355.46 51.14 less-open 324.94 354.22 45.36 less-open 325.2 133.66 50.55 less-open 325.83 116.85 59.07 less-open 326.35 84.85 41.55 less-open 326.38 95.84 66.25 less-open 326.7 92.13 42.06 less-open 326.92 120.62 61.35 less-open 327.09 133.81 37.99 less-open 327.18 342.4 61.29 less-open 327.25 117.36 57.42 less-open 327.44 297.04 38.86 less-open 327.77 138.65 40.12 less-open 328.32 111.04 40.69 less-open 328.42 95 70.18 less-open 328.75 118.57 63.83 less-open 328.95 123.47 58.16 less-open 329.39 129.95 50.85 less-open 329.71 113.89 48.32 less-open 329.84 114.28 39.07 less-open 329.97 116.57 46.26 less-open 332.51 337.86 48.59 less-open 333.59 337.13 60.34 less-open 334.4 104.55 50.05 less-open 334.53 326.15 38.93 less-open 335.73 67.24 43.85 less-open 335.82 219.16 37.64 less-open 336.02 295.18 33.32 less-open 336.78 287.45 83.11 less-open 337.91 218.78 41.71 less-open Page 13 of 13

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - rw1i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 30.12 132.5 48.5 less-open 30.65 136.9 53.6 less-open Note that down-dip compass azimuth 30.88 142.7 48.5 less-open is perpendicular to the strike direction.

32.63 182.9 54.9 less-open 32.95 168.8 52.6 less-open Note that interpreted down-dip compass 33.76 160.5 49.4 less-open azimuths are with respect to 34.17 175.3 43.0 less-open magnetic north.

34.63 161.6 50.4 less-open 35.19 171.3 46.5 less-open Down-dip azimuths & dip angles were 36.39 175.6 51.0 less-open corrected for borehole deviation from 36.92 104.6 28.7 less-open vertical.

38.55 303.6 68.4 less-open 38.55 170.5 50.6 less-open 38.73 9.7 66.7 less-open 41.34 154.3 40.3 less-open 42.85 171.9 52.1 less-open 43.36 154.6 47.6 less-open 44.05 167.2 67.4 less-open 45.27 206.2 15.2 less-open 46.47 188.2 69.4 less-open 47.00 179.5 56.6 less-open 47.24 170.0 53.5 less-open 47.97 165.1 51.8 less-open 48.60 191.3 64.1 less-open 49.62 187.1 54.9 less-open 50.41 191.5 61.6 less-open 51.24 169.6 48.3 less-open 51.55 170.6 52.5 less-open 52.01 182.2 51.3 less-open 52.47 184.4 52.9 less-open 53.06 189.9 51.4 less-open 53.69 180.5 59.2 less-open 53.92 190.8 55.1 less-open 54.27 174.47 52.55 less-open 54.75 150.1 44.4 less-open 55.28 162.5 49.2 less-open 55.56 165.54 55.28 less-open 55.81 152.59 49.12 less-open 56.53 155.2 51.3 less-open 56.83 153.2 52.5 less-open 57.17 348.0 36.3 less-open 57.22 164.4 57.5 less-open 58.30 189.6 50.3 less-open 58.47 184.5 54.8 less-open Page 1 of 3

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - rw1i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 58.80 172.1 58.1 less-open 59.60 148.4 47.7 less-open 59.93 168.2 48.7 less-open 60.08 166.76 47.7 less-open 61.2 134.08 49.41 less-open 61.36 144.4 42.5 less-open 61.77 150.6 53.5 less-open 61.95 149.2 53.6 less-open 62.72 285.5 65.8 less-open 63.12 263.1 57.3 less-open 63.22 126.99 67.86 less-open 64.71 154.72 44.73 less-open 64.77 298.4 66.0 less-open 65.31 129.0 46.1 less-open 65.50 302.3 63.7 less-open 65.87 201.1 52.4 less-open 66.33 218.7 28.6 less-open 66.60 172.0 46.2 less-open 67.32 139.3 40.0 less-open 67.70 150.3 40.6 less-open 68.53 351.6 4.7 less-open 69.58 194.5 43.6 less-open 69.85 158.6 46.8 less-open 70.08 162.2 46.0 less-open 73.89 324.2 62.2 open 75.33 109.3 32.8 less-open 79.44 135.7 35.3 less-open 81.07 242.2 63.6 less-open 83.58 114.4 45.7 less-open 83.71 122.3 50.0 less-open 83.82 112.7 48.3 less-open 84.06 202.7 54.7 less-open 87.09 166.2 42.2 less-open 87.31 299.8 24.5 less-open 97.98 183.8 42.7 less-open 100.46 125.5 32.1 less-open 100.84 328.4 48.8 less-open 103.13 194.6 54.0 less-open 111.58 287.9 49.2 less-open 111.82 141.5 43.8 less-open 114.91 146.0 52.9 less-open 116.19 154.43 51.91 open 117.18 116.62 61.61 less-open 119.45 122.1 42.9 less-open Page 2 of 3

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - rw1i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 120.34 108.7 33.7 less-open 124.07 229.6 30.8 less-open 127.11 152.4 84.5 less-open 127.16 182.4 41.8 less-open 129.71 309.2 48.9 less-open 134.61 284.5 46.5 less-open 135.67 263.7 47.0 less-open 136.95 322.0 43.0 less-open 137.89 290.6 45.2 less-open 138.51 293.1 43.1 less-open 138.64 286.6 43.4 less-open 139.11 273.7 27.2 less-open Page 3 of 3

Appendix C Pump Rates & Observed Drawdown During Pumping Flowmeter Tests

Pumping rates & maximum observed drawdown Indian Point borehole geophysics project 2nd report wells filename = pumprates+drawdown.xls updated 7/18/07 well name pumping rate (gpm) maximum drawdown (feet)

MW-46 0.42 2.1 MW-53 0.44 3.75 MW-54 0.77 1.28 MW-55 0.71 0.97 MW-56 0.43 0.92 MW-57 0.41 0.34 MW-58 0.6 2.35 MW-59 0.67 0.4 MW-60 0.52 3.75 MW-62 0.43 3.94 MW-63 0.58 0.05 MW-65 initially 0.21, dropped to 0.15 by end of tests 3.95 MW-66 0.54 0.55 MW-67 0.54 0.52 RW-1 0.6 1.93