December 3, 2012 LICENSEE:

Omaha Public Power District (OPPD)

FACILITY:

Fort Calhoun Station

SUBJECT:

SUMMARY

OF NOVEMBER 15, 2012, MEETING WITH OMAHA PUBLIC POWER DISTRICT On November 15, 2012, a Category 1 meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and Omaha Public Power District (OPPD) at The Dana College Gardner-Hawks Center (gymnasium), 2848 College Drive, Blair, Nebraska.

The NRC presented an update of issues and oversight activities at Fort Calhoun Station.

Additionally, the NRC provided details regarding the Restart Checklist Basis document. A copy of the presentation is enclosed (Enclosure 1). OPPD presented details of plant status, ongoing work and restart commitments, and independent oversight activities (Enclosure 2).

A video of the public meeting, and responses to the questions directed to the NRC, will be posted on the website devoted to the special oversight at Fort Calhoun Station, available at:

http://www.nrc.gov/info-finder/reactor/fcs/special-oversight.html.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosures will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRCs Agency wide Documents Access and Management System (ADAMS). ADAMS is accessible from the Public Electronic Reading Room page of the NRCs public web site at:

http://www.nrc.gov/readingrm/adams.html.

To receive a summary of future meetings and other plant-specific e-mail distributions, you must subscribe to the Operating Reactor Correspondence electronic distribution for this plant via http://www.nrc.gov/public-involve/listserver/plants-by-region.html Once subscribed, if you wish to discontinue receiving electronic distribution, you may unsubscribe at any time by visiting the same web address above.

CONTACT: Michael Hay, RIV/DRP (817) 200-1147 Docket No.: 50-285

NRC Presentation slides : OPPD Presentation slides UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 1600 EAST LAMAR BLVD ARLINGTON, TEXAS 76011-4511

Omaha Public Power District Electronic Distribution by RIV:

RIV Regional Administrator (Elmo.Collins@nrc.gov)

RIV Acting Deputy Regional Administrator (Steven.Reynolds@nrc.gov)

RIV DRP Director (Kriss.Kennedy@nrc.gov)

RIV Acting DRP Deputy Director (Barry.Westreich@nrc.gov)

RIV Acting DRS Director (Tom.Blount@nrc.gov)

RIV Acting DRS Deputy Director (Jeff.Clark@nrc.gov)

RIV Senior Resident Inspector (John.Kirkland@nrc.gov)

RIV Resident Inspector (Jacob.Wingebach@nrc.gov)

RIV Branch Chief, DRP/F (Michael.Hay@nrc.gov)

RIV Senior Project Engineer, DRP/F (Rick.Deese@nrc.gov)

RIV Project Engineer, DRP/F (Chris.Smith@nrc.gov)

RIV Project Engineer, DRP/F (Jesse.Rollins@nrc.gov)

RIV Public Affairs Officer (Victor.Dricks@nrc.gov)

RIV Public Affairs Officer (Lara.Uselding@nrc.gov)

RIV Project Manager (Lynnea.Wilkins@nrc.gov)

RIV Branch Chief, DRS/TSB (Ray.Kellar@nrc.gov)

RIV RITS Coordinator (Marisa.Herrera@nrc.gov)

RIV Regional Counsel (Karla.Fuller@nrc.gov)

Congressional Affairs Officer (Jenny.Weil@nrc.gov)

OEMail Resource OEWEB Resource (Sue.Bogle@nrc.gov)

RIV/ETA: OEDO (Cayetano.Santos@nrc.gov)

RIV RSLO (Bill.Maier@nrc.gov)

MC 0350 Panel Chairman (Anton.Vegel@nrc.gov)

MC 0350 Panel Vice Chairman (Louise.Lund@nrc.gov)

MC 0350 Panel Member (Michael.Balazik@nrc.gov)

MC 0350 Panel Member (Michael.Markley@nrc.gov)

ADAMS: No Yes SUNSI Review Complete Reviewer Initials: CS Publicly Available Non-Sensitive Category A.

Non-publicly Available Sensitive KEYWORD: 0350 FCS RIV:BC:DRP/F PAO SLO D:DRP MHay VDricks WMaier KKennedy

/RA/

/RA/

/RA/

/RA/

11/28/12 11/29/12 11/30/12 11/30/12 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax

Fort Calhoun Station Public Meeting Nuclear Regulatory Commission November 15, 2012 Blair, Nebraska Opening and Introductions

  • Welcome
  • Introduction of NRC personnel Purpose
  • Status of NRC and OPPD actions

-NRC will present status of inspections and issuance of basis document and issuance of basis document

-OPPD will present details of plant flood recovery actions

  • Allow for public interaction and questions

NRC Inspections

  • Ongoing Inspections

-Permanent local-based resident inspectors

-Inspections by other NRC Specialists

  • Future Inspections Basis Document
  • Overview of Basis Document

- Follows CAL Restart Checklist Structure

- Provides Detailed Scope of Inspection Items p

p

- Living Document

- Available for Public Review

Causes of Significant Performance Deficiencies and Assessment of Organizational Effectiveness 1.a Flooding Issue - Yellow finding 1.b Reactor Protection System contact failure - White finding RESTART CHECKLIST 1.c Electrical bus modification and maintenance - Red finding 1.d Security - Greater than green findings 1.e Third-Party Safety Culture Assessment 1.f Integrated Organizational Effectiveness 2

Flood Restoration and Adequacy of Structures, Systems, and Components 2.a Flood Recovery Plan actions associated with facility and system restoration 2.b System readiness from extended shutdown Basis Document

Basis Document Basis Document Basis Document Current Status

  • Comprehensive and Detailed Inspection Strategy Developed P

f i

F d I ti

  • Performing Focused Inspections

- Flood and Fire Recovery Actions

- Performance Improvement Activities

- Containment Penetrations and Internal Structure Issues

Current Status

  • Currently No Restart Checklist Items are Fully Completed by the Licensee and Ready for Final NRC Review Path Forward PERFORM THOROUGH and INDEPENDENT VERIFICATION of PLANT SAFETY VERIFICATION of PLANT SAFETY OPPD Presentation Lou Cortopassi Site Vice-President / Chief Nuclear Officer Site Vice President / Chief Nuclear Officer Omaha Public Power District NRC Remarks Closing Remarks

Open discussion Open to the public

  • The NRC places a high priority on keeping the public and stakeholders informed of its activities
  • At www.nrc.gov, you can:

- Find public meeting dates and transcripts; p

g p

- Read NRC testimony, speeches, press releases, and policy decisions;

- Access the agencys Electronic Reading Room to find NRC publications and documents; and

- Subscribe to automatically receive correspondence from the NRC Contacting the NRC

  • Report an emergency

- (301) 816-5100 (call collect)

  • Report a safety concern (800) 695 7403

- (800) 695-7403

- Allegation@nrc.gov

  • General information or questions

- www.nrc.gov

1 Driving Through Restart Public Meeting with the U.S. Nuclear Regulatory Commission November 15, 2012 2

Topics for Discussion

  • Plant Status - Fixing the Plant
  • Progress on Commitments for Restart
  • Plan for Sustained Improvement
  • Independent Assessment
  • Closing Remarks 3

Plant Status

  • Safety Performance
  • Human Performance
  • Fixing the Plant 4

Industrial Safety Overview InjuryComparisonSummary 2012dataJanuary1st toNovember14th 2011 2012 UntreatedInjuries:

23 18 FirstAidInjuries:

22 5

OSHARecordable:

21 1

LostTime/Restricted:

1 0

5 Human Performance Overview HumanPerformanceSummary 2012dataJanuary1st toNovember14th 2011 2012 Stationlevelissues 9

1 Departmentlevelissues 134 45 6

134 45 ToDate*

25 12 6

6 0

20 40 60 80 100 120 140 2011

    • 2012
    • 2013
    • 2014
    • 2015
    • 2016 DepartmentLevelPerformanceIssues WhatDoes"Excellence"LookLike?

HumanPerformanceGoals IndustryBestisintheRangeof6to12peryear 52

    • Department Level Performance Goal
  • 2012 data January 1st to November 7th 7

Fixing the Plant Emergency Diesel Generator No. 1 Voltage Regulator Work Complete 8

Fixing the Plant 480 Volt AC Train A Bus Maintenance Complete

9 ContinuedProgress Insert Picture

  • Station Priorities



Safety



Human Performance



Fix the Plant



Corrective Action Program

  • Human Behavior Continues to Improve
  • We are Fixing the Plant
  • Remaining Work is Known 10 OPPDCommitmentsforRestart 1.

Identify causes and implement corrective actions for safety significant findings (Checklist 1.a through 1.d) 2.

Assess safety culture and organizational effectiveness and implement improvement actions (Checklist 1.e and 1.f) 3.

Assess and resolve flooding impact, evaluate systems, and ensure plant is ready for restart (Checklist 2.a and 2.b) 4.

Assess and improve programs and processes that caused significant performance decline (Checklist 3.a through 3.f) 5.

Implement the Integrated Performance Improvement Plan (Checklist 4) 6.

Submit Fort Calhoun Station Restart Report 11 1.a. Flooding CAL Commitment No. 1 ScopingDiscoveryAnalysisImplementation 1.b. Reactor Prot.

Sys. Contactor Failure 75%

1.c. Electrical Bus Modification &

Maintenance 85%

Commitment 1 Progress on Addressing Safety Findings 100%

100%

100%

1.d. Security Issue 100%

100%

75%

75%

100%

100%

100%

75%

100%

100%

90%

75%

12 1.a. Flooding Issue

  • Completed Scoping, Discovery and Analysis
  • Completed Root Cause Analyses
  • Key Corrective Actions Completed

- Replacement of Certain Flood Barriers

- Inspection of All Conduit/Piping Seals

- Improved Flood Procedures Before After

13 1.a. Flooding Issue - Contd

  • Completing Remaining Corrective Actions

- Intake Cell Level Control Modification

- Fire Barrier Certification for Flood Resistance

  • Phase A: Confirmed Static Pressure Resistance
  • Phase B: 30-Day Leakage Test Ongoing
  • Restart Checklist Closure Package Ready for Inspection - November 30 CAL Commitment No. 1 14 Commitment 2 Progress on Safety Culture and Organizational Effectiveness CAL Commitment No. 2 ScopingDiscoveryAnalysisImplementation 1.e. Safety Culture 93%

100%

100%

100%

1.f. Organizational Effectiveness 89%

100%

100%

100%

15 1.e. Safety Culture

  • Independent and Internal Assessments Identified Areas for Improvement

- Develop and Communicate Strategic Vision, Governance and Oversight - Complete

- Enhance Leadership Behaviors - Ongoing

- Engage Workforce in Decisions Based on Vision -

Ongoing

- Improve Corrective Action Program - Ongoing

- Encourage Questioning Attitude and Challenging of Decisions - Ongoing

- Improve Accountability - Ongoing CAL Commitment No. 2 16 1.e. Safety Culture - Contd Improvement Actions

  • Developed, Communicated and Aligned on Strategic Plan; Vision, Mission, and Values; and Performance Management and Accountability Process
  • Bi-Weekly Employee 2Cs Meetings
  • Daily Leaders and Weekly Staff Alignment Meetings
  • Differing Professional Opinion Process Established
  • Safety Conscious Work Environment Training for Supervisors Complete and Ongoing for Employees -

Complete in December

  • Re-Assessment Completed in October CAL Commitment No. 2

17 1.e. Safety Culture - Contd

  • Elements of Safety Culture Metric

- Safety Conscious Work Environment Index

- Nuclear Safety Culture Principals Index

- Engaged Thinking Organization Index (INPO SOER 10-02)

- Employee Engagement Index

- INPO Organizational Culture Index

  • Metric Monitored Monthly - Input from Pulse Surveys CAL Commitment No. 2 18 1.e. Safety Culture - Contd Safety Culture Monitoring Results Safety Conscious Work Environment Index Improving

- Management Takes Concerns Seriously

- Culture Conducive to Raising Concerns

- Awareness and Willingness to Use ECP

- Comfortable Escalating Concerns Nuclear Safety Culture Principles Index Improving

- Supervisors Reinforcing use of Human Performance Tools

- Staff Encouraged to Bring Problems Forward

- Supervisors Reinforcing use of Operating Experience CAL Commitment No. 2 19 1.e. Safety Culture - Contd Safety Culture Monitoring Results

  • Management Focus Areas

- Managing Distractions

- Inter-Department Communications

- Coordinating Issues Between Work Groups

- Employee Concerns Program Confidentiality CAL Commitment No. 2 20 CAL Commitment No. 3 100%

93%

Commitment 3 Progress on Systems Ready for Restart ScopingDiscoveryAnalysisImplementation 2.a. Flood Recovery Restoration Actions 2.b.1. System Health Reviews 2.b.2. Reactor Safety Strategic Performance Area Review 91%

100%

100%

100%

70%

100%

100%

0%

100%

100%

50%

10%

50%

21 Commitment 3 Progress on Systems Ready for Restart - Contd CAL Commitment No. 3 2.b.3. Flood Impact on Soils & Structures 2.b.4. Containment Penetration Design 2.b.5. Containment Internal Structure Design ScopingDiscoveryAnalysisImplementation 80%

95%

100%

100%

10%

75%

100%

100%

5%

75%

90%

100%

22 2.a. Flood Recovery Restoration Actions

  • Fort Calhoun Station Flooding Recovery Plan

- 453 Actions in Six Sections

  • Site Restoration
  • Plant Systems and Equipment
  • Long Term Equipment Reliability
  • Design and Licensing Basis
  • Emergency Planning
  • Security

- Flood Restoration Actions Part of the Integrated Performance Improvement Plan CAL Commitment No. 3 23 2.a. Flood Recovery Restoration Actions

  • Total Flood Recovery Plan

- 453 Actions

  • Physical Work Complete

- 410 Actions

  • Closure Review Board Complete

- 343 Actions

  • NRC Inspection Plan

- 196 Actions

  • NRC Inspection Complete

- 67 Actions CAL Commitment No. 3 24 2.b.1 System Health Reviews

  • Process Documented in a Station Procedure
  • Evaluating Important Plant Systems
  • Identify Issues that Could Affect System Health
  • Enter Issues into Corrective Action Program
  • Provide Confidence that Systems are Ready for Restart CAL Commitment No. 3

25 2.b.3. Flood Impact on Soils & Structures Final Actions

  • Local Expert Geotechnical Firms Analysis Final Report Issued on September 18, 2012
  • Issuance of Final Safety-Qualified Expert Firms Analysis Final Report Delayed
  • Conclusion - No Negative Effects on Safety-Related Structures
  • Restart Checklist Closure Package Ready for Inspection - December CAL Commitment No. 3 26 2.b.4 Containment Penetration Design Fort Calhoun Staff Identified 614 Containment Penetrations that Could Degrade under Certain Potential Accident Conditions
  • Options are Being Evaluated for Resolution of the Remaining Penetrations CAL Commitment No. 3 27 2.b.5 Containment Internal Structure Design Fort Calhoun Staff Identified Certain Structural Elements Inside the Containment may not Meet Design Margins - Containment Shell not Affected
  • Completed As-Built Verifications and Discovery nearly Complete
  • Developed Engineering Models for Analysis
  • Analyzed Internal Structures using Current Licensing Requirements
  • Evaluating Options for Resolution CAL Commitment No. 3 28 CAL Commitment No. 4 Commitment 4 Progress on Programs and Processes Ready for Restart 3.a. Corrective Action Program 3.a.1. Identify, Analyze

& Correct Performance Deficiencies 3.b.1. Safety Related Parts 3.b.2. Equipment Qualification ScopingDiscoveryAnalysisImplementation 70%

100%

100%

100%

50%

100%

100%

100%

5%

100%

100%

75%

20%

90%

100%

60%

29 CAL Commitment No. 4 Commitment 4 Progress on Programs and Processes Ready for Restart - Contd ScopingDiscoveryAnalysisImplementation 3.c.1. Vendor Modifications 3.c.2. 10CFR50.59 Screening & Safety Evaluations 3.d.1. Vendor Manuals 3.d.2. Equipment Service Life 10%

100%

100%

95%

20%

98%

100%

75%

55%

100%

100%

95%

5%

100%

100%

95%

30 CAL Commitment No. 4 Commitment 4 Progress on Programs and Processes Ready for Restart - Contd ScopingDiscoveryAnalysisImplementation 3.e.1. Operability Determinations 3.e.2. Degraded /

Non-Conforming Equipment 3.f. Quality Assurance 15%

100%

100%

80%

15%

100%

100%

80%

83%

100%

100%

100%

31 3.a. Corrective Action Program (CAP)

  • Fort Calhoun Staff has been Implementing Improved CAP Process for Six Months
  • Process Implementation Improvement and Effectiveness Observed
  • Expected Behaviors and Culture Being Reinforced CAL Commitment No. 4 32 3.a. Corrective Action Program (CAP)
  • Corrective Action Program Metric Elements

- Condition Report Generation

- Engagement Ratio

- Good Catches

- Self-Identification Rate

- Repeat Events

- Review Rejection Rate

- Age of Reviews and Actions

- Overdue Reviews and Actions

- Number of Open Condition Reports CAL Commitment No. 4

33

  • IPIP Revision 4 Docketed November 1
  • Addresses Restart Decision-Making Process and Criteria
  • Describes Plan for Sustained Improvement Commitment 5 Integrated Performance Improvement Plan (IPIP)

CAL Commitment No. 5 34 Restart Decision-Making Criteria

  • Confirmatory Action Letter Commitments Addressed
  • Operational Readiness Assessment Completed
  • Systems, Programs and Departments Determined to be Ready for Restart
  • Independent Assessments Completed

- Nuclear Oversight Department

- Corporate Governance and Oversight Committee

- Safety Audit and Review Committee

  • Restart Report Submitted to NRC CAL Commitment No. 5 35 Plan for Sustained Improvement
  • Operating Services Agreement is the Foundation for Achieving and Sustaining Excellence
  • Blended OPPD/Exelon Leadership Team Functioning Effectively
  • Integration Team of Exelon Experts Providing Site Support and Transition Planning in 22 Functional Areas
  • Goal - Implement the Exelon Nuclear Management Model and Full Integration into the Exelon Fleet CAL Commitment No. 5 36 IndependentAssessments

37 OPPDs Commitment Tonight We Updated You on

  • Plant Status - Fixing the Plant
  • Progress on Commitments for Restart
  • Plan for Sustained Improvement
  • Independent Assessments