ML12335A552
| ML12335A552 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 09/30/2003 |
| From: | Westinghouse |
| To: | Atomic Safety and Licensing Board Panel |
| SECY RAS | |
| References | |
| RAS 21631, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 | |
| Download: ML12335A552 (1) | |
Text
United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:
Entergy Nuclear Operations, Inc.
(Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:
Identified:
Admitted:
Withdrawn:
Rejected:
Stricken:
Other:
NYS000369-PUB-00-BD01 10/15/2012 10/15/2012 NYS00369A and NYS00369B (REDACTED PUBLIC VERSION)
Submitted: December 22, 2011 Contains Westinghouse Designated Proprietary Information Subject to Nondisclosure Agreement Os 35so4f WCAP-12191 Revision 3 Vendor Proprietary Information Westinghouse Proprietary Class 2
---_/
September 2003 Transient and Fatigue Cycle Monitoring Program Transient History Evaluation Report for Indian Point Unit 2 Addendum 1 Westinghouse IPECPROP00004699 IPECPROP00004699