ML12335A549

From kanterella
Jump to navigation Jump to search
Official Exhibit - NYS000362-PUB-00-BD01 - Westinghouse, WCAP-17200-P, Rev. 0, Environmental Fatigue Evaluation for Indian Point Unit 3 (June 2010) (WCAP-17200-P Rev. 0)
ML12335A549
Person / Time
Site: Indian Point  
Issue date: 06/30/2010
From:
Westinghouse
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 21631, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12335A549 (1)


Text

United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

NYS000362-PUB-00-BD01 10/15/2012 10/15/2012 NYS000362 (REDACTETD PUBLIC VERSION)

Submitted: December 22, 2011 Contains Westinghouse Designated Proprietary Information Subject to Nondisclosure Agreement WCAP-17200-P Revision 0 Vendor Proprietary Information Westinghouse Proprietary Class 2 Environmental Fatigue Evaluation for Indian Point Unit 3 e inghouse IPECPROP00056577 June 2010 IPECPROP00056577