ML12334A794
| ML12334A794 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 06/15/2004 |
| From: | Teagarden G ERIN Engineering & Research |
| To: | Atomic Safety and Licensing Board Panel |
| SECY RAS | |
| References | |
| RAS 21597, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 | |
| Download: ML12334A794 (10) | |
Text
- FILE NAME CLINCHR.INP
- DESCRIPTIVE TITLE DESCRIBING THIS "CHRONC" INPUT FILE CHCHNAME001 'CLINTCHR.INP - CLINTON CHRONC, "New" COMIDA2-Based Food Model'
- G.A.TEAGARDEN (ERIN ENGINEERING) 6/15/04
- EMERGENCY RESPONSE COST DATA BLOCK
- DAILY COST FOR A PERSON WHO IS EVACUATED (DOLLARS/PERSON-DAY)
100
- IE FROM $27/DAY AT CPI =113 IN 1986 AS IN NUREG/CR-4551
- REF: BOL STATISTICS DATA DEC 6 2000 SERIES ID CUUR0000SA0 VALUE FOR 2000
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
- 27.00
- 1.52 = 41.15 CHEVACST001 41.15 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
- DAILY COST FOR A PERSON WHO IS RELOCATED (DOLLARS/PERSON-DAY)
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
CHRELCST001 41.15 (INCLUDES FOOD AND HOUSING COSTS BUT NOT LOST INCOME)
- LONG TERM PROTECTIVE ACTION DATA BLOCK
- THE INTERMEDIATE PHASE APPROACH HAS BEEN REVISED BY MACCS2.
- VARIABLE TMIPND IS NO LONGER USER DEFINED, BUT IS CALCULATED BY MACCS2
- AS FOLLOWS:
- TMIPND = DUR_INTPHAS + ENDEMP
- ENDEMP IS DEFINED IN THE EARLY FILE AS 7 DAYS
- DUR_INTPHAS IS DEFINED HERE DUR_INTPHAS 3.15E7 (in seconds) (1 YEAR INTERMEDIATE PHASE)
- LONG-TERM PHASE DOSE PROJECTION PERIOD, THE DURATION OF THE EXPOSURE
- PERIOD OVER WHICH THE LONG-TERM DOSE CRITERION IS EVALUATED (SECONDS)
CHTMPACT001 1.26E8 (4 YEAR LONG TERM PHASE)
- DOSE CRITERION FOR INTERMEDIATE PHASE RELOCATION (Sv) (YEARS 0-1)
CHDSCRTI001 0.02 (2 REM)
- DOSE CRITERION FOR LONG-TERM PHASE RELOCATION (Sv) (YEARS 1-5)
CHDSCRLT001 0.02 (2 REM)
- CRITICAL ORGAN NAME FOR LONG-TERM ACTIONS United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:
Entergy Nuclear Operations, Inc.
(Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:
Identified:
Admitted:
Withdrawn:
Rejected:
Stricken:
Other:
NYS000279-00-BD01 10/15/2012 10/15/2012 NYS000279 Submitted: December 21, 2011
CHCRTOCR001 'L-EDEWBODY'
- Long Term Exposure Period Previously permanently set to:
- one million years = 3.15 E13 seconds
- MACCS2 allowable range is 3.15E7 to 1.E10 CHEXPTIM001 9.45E8 (30 YEARS PER EPA STANDARD DEFAULT EXP.
FACTORS)
- REF/BASIS:
- THE GUIDENCE OF EPA-400 IS USED HERE.
- DUR_INTPHAS/DSCRTI -
- (SECTION 4.2 AND TABLE 4-2 OF EPA-400). THE VALUES OF DUR_INTPHAS AND DSCRTI
- ARE SET TO THESE VALUES.
- NOTE THAT THE CALCULATIONAL BASIS FOR THE EPA-400 PAG AND THE MACCS
- INTERMEDIATE MODEL ARE CONSISTENT; BOTH CONSIDER GROUND SHINE AND
- RESUSPENSION ONLY.
- TMPACT/DSCRTL-
- THE LONG-TERM HABITATION DOSE IS INTERGRATED OVER THE LENGTH OF THE
- LONG-TERM PHASE (TMPACT). IF THE DOSE TO THE CRITICAL ORGAN (CRTOCR)
- EXCEEDS THE LONG-TERM DOSE CRITERION (DSCRTL) THEN MITIGATIVE ACTIONS ARE
- ASSUMED TO BE TAKEN.
- DOSES IN THE SECOND AND SUBSEQUENT YEARS TO 0.5 REM/YEAR AND THE TOTAL OVER
- THE MACCS LONG TERM PHASE MODEL CANNOT IMPLEMENT THIS PAG DIRECTLY SINCE
- THE DOSE INTEGRATION IS PERFORMED OVER THE SPECIFIED TIME AND THEN
- COMPARED TO THE DOSE CRITERION. NO CONSIDERATION IS GIVEN TO LIMITING ANY
- ONE YEAR'S DOSE TO LESS THAN 0.5 REM. THEREFORE, AN ALTERNATE APPROACH IS
- REQUIRED.
- THE NUREG-1150 ANALYSES WERE PERFORMED USING THE ASSUMPTION OF 2 REM IN THE
- ALTHOUGH NO BASIS FOR THIS ASSUMPTION COULD BE FOUND IN THE NUREG/CR-4551
- MODEL THAT SPECIFIED IN EPA-400. THE DIFFICULTY WITH SPECIFYING 3 REM IN
- 49 YEARS DIRECTLY FOR THE LONG TERM PHASE IS THAT IN EXCESS OF 0.5 REM IN
- IN THE FIRST YEAR).
- SINCE RADIOACTIVE DECAY AND WEATHERING WILL REDUCE GROUNDSHINE AND
- RESUSPENSION DOSES OVER LONG TIMES, IT IS CLEAR, IN THE CONTEXT OF THE
- MACCS MODEL, THAT A SHORTER INTEGRATION TIME COULD BE USED WITHOUT
- EXCEEDING THE EPA-400 PAG. THE NUREG/CR-4551 AUTHORS (SANDIA) APPEAR TO
- HAVE CONCLUDED THAT A 4 YEAR TIME PERIOD WAS APPROPRIATE, ALTHOUGH THEY
- IN 50 YEARS WILL NOT BE MET.
- EQUIVALENTLY THAT NO MORE THAN 1 REM AVERAGED OVER THE 6TH TO 45TH YEARS
- (EVEN IF IT ALL OCCURRED IN THE SIXTH YEAR) WAS AN ACCEPTABLE MODEL.
- THIS ANALYSIS USES THE FOLLOWING RATIONALE TO SPECIFY THE LONG TERM
- PHASE PARAMETERS:
- 1. THE TOTAL LONG TERM DOSE CANNOT EXCEED 2 REM
- THE BASIS FOR THIS ASSUMPTION IS THAT, IN THE CONTEXT OF THE MACCS MODEL
- IN ANY ONE YEAR OF THE LONG TERM PHASE. (2 REM COULD BE INCURRED IN THE
- 2ND YEAR AND 0 REM IN THE REMAINING 48 YEARS). THIS WILL PREVENT THE DOSE
- IN ANY YEAR FOLLOWING THE FIRST YEAR TO EXCEED THE DOSE ALLOWED IN THE
- FIRST YEAR.
- 2. THE INTEGRATION TIME WILL BE 4 YEARS
- THE BASIS FOR THIS ASSUMPTION IS THAT THE AVERAGE ALLOWABLE EXPOSURE OVER
- THE LONG TERM PHASE WILL BE EQUAL TO THE EPA-400 YEARLY LIMIT OF 0.5 REM.
- IT SHOULD BE NOTED THAT THE COMBINED INTERMEDIATE AND LONG TERM DOSE
- LIMITS SPECIFIED HERE ARE IDENTICAL TO THOSE USED BY SANDIA, EXCEPT THAT
- THEY ARE EXPLICITLY SPLIT BETWEEN THE TWO PHASES.
- EPA-400, "MANUAL OF PROTECTIVE ACTION GUIDES AND PROTECTIVE ACTIONS
- FOR NUCLEAR INCIDENTS", US EPA, 1991.
- CRTOCR -
- THE CRITICAL ORGAN IS TAKEN TO BE THE EDE WHOLDEBODY (TEDE).
- EXPTIM - IS A NEW VARIABLE ADDED IN MACCS2, 30 YEARS FROM USERS' GUIDE
- DECONTAMINATION PLAN DATA BLOCK
- NUMBER OF LEVELS OF DECONTAMINATION CHLVLDEC001 2
- DECONTAMINATION TIMES CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION
- (SECONDS)
CHTIMDEC001 5.184E6 1.0368E7 (60, 120 DAYS)
- DOSE REDUCTION FACTORS CORRESPONDING TO THE LVLDEC LEVELS OF DECONTAMINATION CHDSRFCT001 3. 15.
- COST OF FARM DECONTAMINATION PER FARMLAND UNIT AREA (DOLLARS/HECTARE)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION
- CHCDFRM0001 562.5 1250.
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
CHCDFRM0001 855.00 1900.00
- COST OF NONFARM DECONTAMINATION PER RESIDENT PERSON (DOLLARS/PERSON)
- FOR THE VARIOUS LEVELS OF DECONTAMINATION
- CHCDNFRM001 3000. 8000.
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
CHCDNFRM001 4560. 12160.
- FRACTION OF FARMLAND DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS CHFRFDL0001.3.35
- FRACTION OF NON-FARM DECONTAMINATION COST DUE TO LABOR
- FOR THE VARIOUS DECONTAMINATION LEVELS CHFRNFDL001.7.5
- FRACTION OF TIME WORKERS IN FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS CHTFWKF0001.10.33
- FRACTION OF TIME WORKERS IN NON-FARM AREAS SPEND IN CONTAMINATED AREAS
- FOR THE VARIOUS DECONTAMINATION LEVELS CHTFWKNF001.33.33
- AVERAGE COST OF DECONTAMINATION LABOR (DOLLARS/MAN-YEAR)
- CHDLBCST001 35000.
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
CHDLBCST001 53200.
- REF/BASIS
- ALL DECONTAMINATION VALUES FROM USERS' GUIDE, UPDATED TO YEAR 2000
- AS APPROPRIATE
- INTERDICTION COST DATA BLOCK
- DEPRECIATION (DETERIORATION) RATE DURING INTERDICTION PERIOD (PER YEAR)
CHDPRATE001.20 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- INVESTMENT INCOME RETURN (DISCOUNT RATE) DURING INTERDICTION PERIOD (PER YEAR)
- THIS VALUE SHOULD BE DERIVED AS A REAL RETURN RATE ADJUSTED FOR INFLATION CHDSRATE001.12 (VALUE OBTAINED FROM WASH-1400, APPENDIX 6)
- POPULATION RELOCATION COST (DOLLARS/PERSON):
- ALTERNATIVE HOUSING, MOVING COSTS, AND LOST INCOME FOR PEOPLE IN
- AREAS WHICH REQUIRE DECONTAMINATION, INTERDICTION, OR CONDEMNATION
- CHPOPCST001 5000.
- CPI 2000/1986, FACTOR (172.2/113 = 1.52 )
CHPOPCST001 7600.
- ABOVE VALUES CONSISTENT WITH USERS' GUIDE
- GROUNDSHINE WEATHERING DEFINITION DATA BLOCK
- NUMBER OF TERMS IN THE GROUNDSHINE WEATHERING RELATIONSHIP (EITHER 1 OR 2)
CHNGWTRM001 2
- GROUNDSHINE WEATHERING COEFFICIENTS CHGWCOEF001 0.5 0.5 (JON HELTON)
- HALF LIVES CORRESPONDING TO THE GROUNDSHINE WEATHERING COEFFICIENTS (S)
CHTGWHLF001 1.6E7 2.8E9 (JON HELTON)
- ABOVE VALUES CONSISTENT WITH USERS' GUIDE
- RESUSPENSION WEATHERING DEFINITION DATA BLOCK
- NUMBER OF TERMS IN THE RESUSPENSION WEATHERING RELATIONSHIP
CHNRWTRM001 3
- RESUSPENSION CONCENTRATION COEFFICIENTS (/ METER)
- RELATIONSHIP BETWEEN GROUND CONCENTRATION AND INSTANTANEOUS AIR CONC.
CHRWCOEF001 1.0E-5 1.0E-7 1.0E-9 (VALUES HERE SELECTED BY JON HELTON)
- HALF-LIVES CORRESPONDING TO THE RESUSPENSION CONCENTRATION COEFFICIENTS (S)
CHTRWHLF001 1.6E7 1.6E8 1.6E9 (6 MONTHS, 5 YEARS, 50 YEARS)
- ABOVE VALUES CONSISTENT WITH USERS' GUIDE
- SITE REGION DESCRIPTION DATA BLOCK
- SOME VALUES SPECIFIED HERE ARE DEFAULT PLACEHOLDERS, REQUIRED BY MACCS2.
- THEY ARE ONLY UTILIZED IF POPFLG=UNIFORM (I.E. NO SITE FILE IS USED)
- DEFAULT PLACEHOLDER VALUES ARE TAKEN FROM USER GUIDE EXAMPLES P. 7-17
- IF POPFLG=FILE, THESE DEFAULT VALUES ARE OVERRIDEN BY SITE FILE
- FRACTION OF AREA THAT IS LAND IN THE REGION CHFRACLD001 0.95 (DEFAULT, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF LAND DEVOTED TO FARMING IN THE REGION CHFRCFRM001 0.382 (DEFAULT, SITE FILE OVERRIDES THIS VALUE)
- AVERAGE VALUE OF ANNUAL FARM PRODUCTION IN THE REGION (DOLLARS/HECTARE)
- (CASH RECEIPTS FROM FARMING PLUS VALUE OF HOME CONSUMPTION)/(LAND IN FARMS)
CHFRMPRD001 371.0 (DEFAULT, SITE FILE OVERRIDES THIS VALUE)
- FRACTION OF FARM PRODUCTION RESULTING FROM DAIRY PRODUCTION IN THE REGION
- (VALUE OF MILK PRODUCED)/(CASH RECEIPTS FROM FARMING PLUS HOME CONSUMPTION)
CHDPFRCT001 0.198 (DEFAULT, SITE FILE OVERRIDES THIS VALUE)
- VALUE OF FARM WEALTH (DOLLARS/HECTARE)
- (AVERAGE VALUE PER HECTARE OF FARM LAND, BUILDINGS, EQUIPMENT TO 50 MILES)
CHVALWF0001 5399.
- AREA WEIGHTED AVERAGE OF SECPOP2000 VALUES (97 ECONOMIC
- REGIONS).
- THIS AVERAGE VALUE IS NOT OVERRIDEN BY SITE FILE
- FRACTION OF FARM WEALTH IN IMPROVEMENTS FOR THE REGION
CHFRFIM0001 0.49
- ZION
- NON-FARM WEALTH, PROPERTY AND IMPROVEMENTS FOR THE REGION (DOLLARS/PERSON)
- THE VALUE OF ALL RESIDENTIAL, BUSINESS, AND PUBLIC ASSETS WHICH WOULD BE
- LOST IN THE EVENT OF PERMANENT INTERDICTION (CONDEMNATION) OF THE AREA CHVALWNF001 106922.
- AREA WEIGHTED AVERAGE OF SECPOP2000 VALUES (97 ECONOMIC
- REGIONS).
- THIS VALUE IS NOT OVERRIDEN BY SITE FILE
- FRACTION OF NON-FARM WEALTH IN IMPROVEMENTS FOR THE REGION CHFRNFIM001 0.8 (NUREG 1150)
CHFDPATH001 'NEW'
- name of the COMIDA2 binary output file BIN_FILE001 'SAMP_A.BIN' (revised data file of 8/12/95)
- Dose limits triggering first year crop disposal of the separate
- milk and non-milk components of the diet, corresponding in purpose,
- more or less, to the MACCS 1.5 input variables PSCMLK and PSCOTH
- For NUREG-1150 calculations, the maximum allowable ground concentrations for
- production of milk and non-milk crops contaminated by an accident occurring
- in the growing season were derived based on an assumed maximum allowable
- the prior results, it is being assumed, for simplicity, that milk and
- non-milk crops contribute equally to the first year dose. Thus, the 5 rem
- effective dose limit used in NUREG-1150 is equally split between milk and
- thyroid limit is split into 7.5 and 7.5 rem for the milk and non-milk
- portions of the diet.
- effective thyroid (doses in sieverts)
DOSEMILK001 0.025 0.075 DOSEOTHR001 0.025 0.075
- Annual dose limits for the subsequent year's (i.e., after the first year)
- interdiction of BOTH the milk and non-milk (combined) components of the diet
- Note: the long-term food critera, GCMAXR, used for NUREG-1150 wre based on
- an ingestion dose integrated from zero to infinity. It is not
possible to
- translate those parameter values into corresponding annual dose limits, as is
- required by the COMIDA2-based food model. The "total" dose limits used in
- NUREG-1150 for "root uptake", 0.5 rem effective and 1.5 rem thyroid, are used
- here as annual dose limits for interdiction of food production in years the
- years subsequent to the accident.
- effective thyroid (doses in sieverts)
DOSELONG001 0.005 0.015
- NUMBER OF NUCLIDES IN THE WATER INGESTION PATHWAY MODEL CHNUMWPI001 4 (NUREG 1150)
- TABLE OF NUCLIDE DEFINITIONS IN THE WATER INGESTION PATHWAY MODEL
- IF A SITE DATA FILE IS DEFINED, THE DATA DEFINING THE WATERSHED INGESTION
- FACTOR IS SUPERSEDED BY THE CORRESPONDING DATA IN THE SITE DATA FILE
- INITIAL ANNUAL INGESTION FACTOR
- WATER WASHOFF WASHOFF ((Bq INGESTED)/
- NUCLIDE FRACTION RATE (Bq IN WATER))
- NAMWPI WSHFRI WSHRTA WINGF CHWTRISO001 Sr-89 0.01 0.004 5.0E-6 (NUREG 1150)
CHWTRISO002 Sr-90 0.01 0.004 5.0E-6 (NUREG 1150)
CHWTRISO003 Cs-134 0.005 0.001 5.0E-6 (NUREG 1150)
CHWTRISO004 Cs-137 0.005 0.001 5.0E-6 (NUREG 1150)
- SPECIAL OPTIONS DATA BLOCK
- DETAILED PRINT OPTION CONTROL SWITCHES, LOOK AT THE CODE BEFORE TURNING ON!!
- KSWDSC CHKSWTCH001 0
- DEFINE THE TYPE 9 RESULTS
- LONG-TERM POPULATION DOSE IN A GIVEN REGION BROKEN DOWN BY THE 12 PATHWAYS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 TYPE9NUMBER 1 (UP TO 10 ALLOWED)
- ORGNAM INNER OUTER
TYPE9OUT001 'L-EDEWBODY' 1 9 (0-50 MILES)
- ECONOMIC COST RESULTS IN A REGION BROKEN DOWN BY 12 TYPES OF COSTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 12 TYP10NUMBER 1 (UP TO 10 ALLOWED)
- INNER OUTER TYP10OUT001 1 9 (0-50 MILES)
- DEFINE A FLAG THAT CONTROLS THE PRODUCTION OF THE ACTION DISTANCE RESULTS
- SPECIFYING A VALUE OF.TRUE. TURNS ON ALL 8 OF THE ACTION DISTANCE
- RESULTS,
- A VALUE OF.FALSE. WILL ELIMINATE THE ACTION DISTANCE RESULTS FROM THE OUTPUT.
TYP11FLAG11.FALSE.
- IMPACTED AREA/POPULATION RESULTS IN A REGION BROKEN DOWN BY 6 TYPES OF IMPACTS
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED
- FOR EACH RESULT YOU REQUEST, THE CODE WILL PRODUCE A SET OF 8 TYP12NUMBER 2 (UP TO 10 ALLOWED)
- INNER OUTER TYP12OUT001 1 6 (0-10 MILES)
TYP12OUT002 1 9 (0-50 MILES)
- Maximal annual food ingestion dose to an individual, requested by IXOT13
- This result is calculated after accounting for temporary or
- permanent interdiction. It is only available for the "new" food model.
- NUMBER OF RESULTS OF THIS TYPE THAT ARE BEING REQUESTED TYP13NUMBER 0 (UP TO 10 ALLOWED)
- IRAD13 is the radial spatial interval at which results are requested
- ORGN13 is the name of the organ for which results are requested
- (allowable values for ORGN13 are 'EFFECTIVE' or 'THYROID')
- IRAD13 ORGN13
- TYP13OUT001 2 EFFECTIVE
- TYP13OUT002 4 EFFECTIVE
- TYP13OUT003 6 EFFECTIVE
- TYP13OUT004 9 EFFECTIVE
.