ML12334A380
| ML12334A380 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 11/14/2012 |
| From: | Gerald Bichof Virginia Electric & Power Co (VEPCO) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 12-692 | |
| Download: ML12334A380 (3) | |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 November 14, 2012 U.S. Nuclear Regulatory Commission Serial No.12-692 Attention: Document Control Desk NAPS: RAP Washington, D.C. 20555 Docket No.
50-338 License No.
NPF-4 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)
NORTH ANNA POWER STATION UNIT 1 POST ACCIDENT MONITORING (PAM) REPORT On October 2, 2012, with Unit 1 in Mode 1 at 100 percent power, the open red indication light for the Phase B containment isolation valve (CIV) 1-CC-TV-104B-1 ("B" RCP CC Supply Isolation Valve SOV-1) was determined to be inoperable.
This Regulatory Guide 1.97 CIV is located outside of containment in the component cooling (CC) water supply line to the "B" reactor coolant pump (RCP).
The cause of the inoperable red open light is a failed bulb. Technical Specification (TS) 3.3.3 Condition A requires restoration of the CIV indication to operable within thirty days. If CIV indication is not returned to service within thirty days, a Post Accident Monitoring Report is required in accordance with TS 5.6.6.
This letter provides the required report and includes our plan and schedule for restoring the CIV indication to service.
This is a valve position open indication operability issue only. The replacement of the bulb with the unit on-line can lead to grounding of the circuit due to possible separation of the bulb glass from its base. This could possibly result in the associated trip valve closing which would be detrimental to Unit 1 operation. Therefore, due to the inherent risks involved with performing maintenance on-line, repairs are scheduled to be performed at the first entry into a unit condition of sufficient duration to allow the repair.
The risks associated with performing repairs on-line include maintenance in a sensitive area (i.e., Control Room Safeguards Equipment Panel) and by-passing the air supply to prevent the CIV from inadvertently closing, which may require manually tripping the reactor and shutting down the running "B" RCP.
Continued operation with this valve open indication inoperable is permitted because there are several levels of alternate indication.
The Plant Computer System (PCS) provides an alternate reliable indication (PCS computer point S1CC003D, "B" RCP Supply Header Valve SOV-1") to determine valve position.
Flow indicators will also indicate zero flow for various "B" RCP parameters when 1-CC-TV-104B is closed. In addition, the closed green light indication is operable.
Aoof
Serial No.12-692 Docket No. 50-338 PAM Report Page 2 of 3 The CIV cycled properly, from both SOV-1 and SOV-2, during its last valve position indication test completed on April 24, 2012. If a containment depressurization actuation (CDA) were to occur, both SOVs would receive a signal to close the CIV.
This report has been reviewed and approved by the Facility Safety Review Committee.
If you have any questions or require additional information, please contact Mr. Page A.
Kemp at (540) 894-2295.
Sincerely, G. T. Bischof Site Vice President Commitments made in this letter: Replacement of the open red indication light for 1-CC-TV-104B-1 during the next entry into a unit condition of sufficient duration to allow the repair.
Serial No.12-692 Docket No. 50-338 PAM Report Page 3 of 3 cc:
U.S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE, Suite 1200 Atlanta, Georgia 30303-1257 NRC Senior Resident Inspector North Anna Power Station Dr. V. Sreenivas NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, Maryland 20852-2738 Ms. K. R. Cotton NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, Maryland 20852-2738