Washington Division ER OF T

IT FAC INSPECTION FINAL REPORT IREFUELING OUTAGE 3R15 9

RIV000133 Submitted: October 17, 2012 EXCERPT

Flow Accelerated Corn on Examination Partitioning Information Component BeginiCaVRow EndingiCoURow Procedure:

ENN-NDE-9.05 Work Scope:

3R15 Site/Unit:

IP

/

3 Report No.:

3RWFAC-W-054 3

Sunirnary No..

DS-RHD-LCV-R-1105A-50010 Procedure Rev.:

1

~

Work Order No.:

127136-01 Page:

1 of Building:

Turbine RoomlElev.:

NIA

/

36' Area:

NIA

-I-,--

Component Information Diawiiig No EC-H-50010

==

Description:==

Reducer, Pipe & Elbow DIS of RHPLCV-IlO5A.

~-

0.250" I Start:

1 0.500 Verity:

0.750" Verily:

1.000 NIA

-~

-~

Verify:

M A M A Final: 16:37 MM Instrument:

Transducer:

M UPSTExl Main ONST M DNSTExt Branch Branch Ext ReferenceBim Geometry Type:

REDUCER Outside Diameter:

10x4" Max. Thickness:

0.718" Min. Thickness: - 0.374" Nominal Thickness:

0.5Wm.337" Trnin.: 1.378"M.202 Grid Sire:

1.0 Min. Thickness Location: -

Tis 8 A-ai Max. Thickness Location: __

?/S B H-l ator Block Temp. Tool:

Manufacturei.:

Panametrics Manufacturer:

Panametrica Serial No.:

A22634 Manufacturer:

PTC Modoi:

I_

37-DL PIUS Serial Ne.:

623647 Type:

4-Step Block Serial No.:

Sciial No.: - 041 164204 Sire:

0.312" Freq.: 5.0 MHZ RefJSimulator Block Temp.: 71 "F

Coupiant:

Gam:

221940 Ultragel II Type:

54dB Mode!:

D791-RM MateriallComponent Temp.: 68 "F

Batch No.:

07225 Range:

2.0

  1. of Eicinents:

OW1

~orniI~entsl~~bstnIclions:

Shot as previously gridad.

Ctesuits:

Accept ' Reject Eva1 Tscreen=0.294,0.520", Taccept =0.158",0.378".No readings below T s c r m.

ITGminer L BVCI 1i.i Signature.(

Date I Reviewer Signature Date I

cy N

M cc, N

O D

r K

I