ML12285A833
| ML12285A833 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 04/03/2003 |
| From: | Danson C Entergy Corp |
| To: | Atomic Safety and Licensing Board Panel |
| SECY RAS | |
| References | |
| RAS 23610, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 | |
| Download: ML12285A833 (10) | |
Text
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
RIV000130 Submitted: October 11, 2012
r
~bntergy uJtrasomc cxammauon l'(epon:
Sys./ Comp. ID:
Main Feedwater I FW-02.4-15E DWG No. or Sketch: 9321-F-20193 Rev. 56 QA Category: Non Cat ASME XI Class: N/A Cat: N/A Component Configuration: Pipe to Elbow to Pipe.
Orientation:
0 Degree Angle: 0 ° Mode: Longitudinal Equipment IPEC Unit#
3 Report No.:
03UT081 Page_1_of S Exam Item:
FW*02.4-15E I Pipe, Elbow, Pipe WR/Mod:
IPJ-02-24705 Procedure:
NDEP 9.4-12(1)
Rev.:
4 Type of Material:
Size:
30" Carbon Steel Thickness:
1.260" 002144201 Panametrics 36DL+ Due: 3/16/2004 Attenuator Linearity Check Sianal1 1 ~*_uu I.':'!'. I_?X 1 }!". l_u~- 15'!'. ~-~~ 1,~ ~-~~ 1_~11_ I I so%~ 1so%-12db I"0%+6dbp0%+rdb I N/A NfAN/A N/
(32 to 48)
(16 to 24)
(64*96)
(64-96) 502080 Panametrics 5 Mhz 0.312" Round D791/ Dual Element Wedge: N/A 6' Self-Cont.
Wedge Meas. Angle:
N/A 0 Exit Point-Front:
Sonotech I Sono 600 Gel Thermometer:
103284 Due: 3/11/2004 103309 Step Wedge T=.75"
- 1.5" Material: Carbon Steel Simulator Block:
N/A Reference Block:
A13082 IIW-2 T= N/A Material: CARBON STEEL N/A" Temperature 90 Of N/A °F 78 °f Entry Surface:
OD Component:
Distance Amplitude Curve Instrument Settings Each Major Screen Division =
0.5"
':fl f+/- lilliE Orient.
FSH Pos.
dB
-,*-step 80 2.0 N/A Step 80 3.0 N/A Range (in.):
5.0" Thick Cal:
2-PT Velocity (in./f.ls):
2332 Sensitivity (dB):
58 Step 80 8.0 N/A Scan Sensitivity 80%
Frequency (mHz): 5 50 Reject:
Off Filter:
Full Pulse Length:
Fixed Damping:
Fixed Mode Select:
Dual Rep. Rate:
Fixed DEC/Gate:
On
- ~1111
~ 111 II
'*******¥*******-¥*-*-
Calibration Times:
1 o945 I 1o3o]J1so I 1
-~
1 2 3 4 5 6 7 8 9 10 Jacks:
T/R Acceptance Standard:
87.5% of nominal as per AP-49 requirements.
Recordable lndication(s}: Yes Recording Level:
N/A% DAC Evaluation Level:
N/A% DAC 100 %Complete Limitations: Integral Attachment Remarks: Recordable Indications reference page 2 & 4 of 5.
Obstruction due to Integral Attachment reference page 2 of 5.
Reference page 4 of 5 for Lamination.
Examiner:
cC,_-c::Z------
Christopher J. Danson Level: Ill Date: 3/31/2003 Examiner. ~~
Mich.. l W Julison Llllllii*IIL Reviewed by:
~
~
Levet' J:1?t.
ANII Review:
r; +
Date: 3/31/2003 Date: Y/3/~3-Date: ___ _
IPEC00020854 98 Of
'1J m
()
0 0 2 0
OJ 01 01
'1J m
()
0 0 0
1\\.)
0
())
0'1 0')
NDEP 9.4*,_,,, Rev.4 nent 2
- , _,., 1 of 1 Report No.:
03UT081
~Entergy Page 2
of 5
Sys. I Comp. ID: Main Feedwater I FW-02.4-15E Material:
Carbon Steel High Reading: 1.625" Exam Item:
Pipe, Elbow,Pipe Size:
30" Low Reading: 0.513" DWG No.:
9321-F-20193 rev. 56 Thickness:
1.260" Grid Size:
6" WR/Mod:
IP3-02-24705 Configuration:
See drawing below Datum Point:
Outside Radius of Elbow QA Category:
Non Cat. 1 ASME XI Class:
N/A Cat:
N/A Acceptance Standard:
1.103" Procedure:
NDEP 9.4-12 !Q Rev.:
4 FW-02.4-lSE t.l/m; 11 a It~ '~'1 6" Grid Spacing FW-02.4-15E-02 p A~.-
Integral 13
-* Attachment 7 17 A1 11 12
~
lr-11 EW::Il2 !1-l§E::Il2 ~
~
Min: 0.513" FW.02.4-16P.03
~
FW-02.4-lSE i
LOW READING Looking DIS Max: 1.625" FW.02.4-15E.02
~
10 I
~
-- 0.496" I'
r-A1-
\\_ FW.027-16P-03 9
I Ellll::Q2 !1*l !iE::Il2 6
Obstruction due to l~
Min: 1.348" Integral Attachment EW.0~.~*14P.Oj ~
Max: 1.401" 8
AOS, A09 & A10 Min: 1.379" FW.02.4-14P.01 10 Max: 1.399" I
A1-~
7 6
A B
c D
E Remarks:
All thickness readings above are in thousandths of ce.-- £?__
an inch.
Examiner:
6hristoeher J. Danson Level:
Ill Date:
3/31/2003 For Min. & Max. Readings reference above Sketch.
Examiner: JffaLJ, (/j_~tJ~/~.-.~
Low readings due to lamination.
Michael W. Julison Level:
IlL Date:
3/31/2003 Obstruction due to Integral Attachment see above.
lt?z [j,J/
'7/2-/o:J Reviewed by:
Level: rn-Date:
ANII Review:
r-;J Date:
Method Used: Grid Point Readings REA1-01
- . WinPiusoate.-f3rid
- ..
- rw-o2.4.:;" *.
- ** v
~' **
F< f~v£!1
~..
"t['kll),.
R.epoit.Date: 3/3.112003
Report Date: :mt;2oo3* *.
..... *~. **'*.....
..... ~*.. ~:... :,.. '. '....
.*.~**.~**
~*. *~*.. **
- ~*.. Rl**
.~.*
.*~.*
- "-.)
\\
. \\..S 10
\\[~ ~ q{?.{o?
J..v1£'[::
~*
- -1).
- \\
- ()..,
~.
I
8 7
6 5
D c
B A
8 7
5
- 4.
to REVISIONS 2
- *, *. 11Ait la:*zaas.*.
~... ~. '. c.~..
CH<*o INDIAN POINT NO.3 NUCLE "OES--SIP=Vc-*
I
=x"'""' EROSION GORROSIDN AUXILIARY SOILER.I lnSCIPLli<E:OIR. BOILER-FEED PIPINI FROM 30 HEADER T(
...-----'-tp RciruJ:APPiPAAiJ<OVWi**cc f, WATER LINES. IN AU.
BGI.LER BUILDJNG sc.o.~r NewYorkPower ** *
""" Allthorlty 2
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
TRAVELER PACKAGE CHECKLIST Preinspection b~efing given by Erosion/Corrosion Engineer ~%~**~~~
E/C ng.
0 e
/
~
UTTech UTTech jJTTech UTTech Traveler package contents
__§f{_
~
UTTech EIC Eng.
- a.
- b.
- c.
- d.
Copy of procedure NDEP 9.4-12 Calibration sheet Drawing with point highlighted Data sheet
- e.
E/C Engineers phone number ~(-2{(:,* **z.
Location verified against drawing:
UTTech Preinspection point setup per procedure NDEP-9.4-12:
(If gridding is used)
- a.
Correct grid size used
- b.
Grid correctly laid out
- c.
Grid lettered and numbered correctly
- d.
Grid low stress stamped correctly
- e.
Area up/downstream of component ~~o__1y laid out Data Logger
- a.
- b.
- c.
UTTech Inspection point used as file name Operators ID correct Instrument ID correct Data Sheet
- a.
Flow direction correct
- b.
Sketch drawn correctly
- c.
Component number verified Calibration Sheet correct Daily review complete if urf ol
~*
. ~7 03 t
~--
2 UTTech
~~
E/C Eng.
NOTE:
UT Technician sign-off is required prior to start of inspeCtion activity.
Engineering sign-off is required after verification of activity.
R12 Traveler IPEC00020861
Inspection Point Work Order Pipe Size, inches Tnom Screen (87.5°/o Tnom)
Screen (70°/o Tnom)
Grid Size, in.
Pipe Class INDIAN POINT 3 R012 FW-02.4-15E I P3-02-24 705 30 1.260 1.103 0.882 6"
B-1 Pipe Spec, Grade A-672 Gr. 870 Class 21 Fitting Spec, Grade A-234 WPC Schedule N/A Design Pressure, psi 1440 Design Temperature °F 450 Allowable Stress, psi 17500 IPEC00020862