February 12, 2010 Ameren Corporation Environmental Services 1901 Chouteau Avenue St. Louis, Missouri 63103 Attention: Gail P. Gary Phone: 314-554-2824 Email: ggary@ameren.com RE:
Groundwater Monitoring Services Fuel Groundwater Wells AmerenUE, Callaway Nuclear Power Plant Reform, Missouri Terracon Project No. 09107004
Dear Ms. Gary:
lrerracan Terracon Consultants, Inc. (Terracon) appreciates the opportunity to conduct groundwater monitoring activities at the above-referenced site. Groundwater samples were collected on January 19, 2010. Our field notes from the sampling event and the laboratory analytical report are attached. The following table summarizes the lab results:
Parameter Weii937A Weii937C 01/19/2010 01/19/2010 Benzene, mg/L
<0.00050 0.0024 Toluene, mg/L
<0.0050
<0.0050 Ethylbenzene, mg/L 0.00099 0.0012 Total Xylene, mg/L
<0.0015 0.0018 Methyl tert-butyl ether, mg/L
<0.0050
<0.0050 TPH as Gasoline, mg/L
<0.10
<0.10 TPH as Mineral Spirits, mg/L
<0.10
<0.10 TPH as Kerosene, mg/L
<0.10
<0.10 TPH as Diesel, mg/L 0.10 2.4 TPH as #6 Fuel Oil, mg/L
<0.10
<0.10 TPH as Hydraulic Fluid, mg/L
<0.10
<0.10 TPH as Motor Oil, mg/L
<0.50
<0.50
<value= not detected above displayed laboratory detection limit Bold= Sample detected above laboratory detection limit Laboratory analysis conducted by Environmental Science Corp.
Terracon Consultants, Inc.
3601 Mojave Court, Suite A Columbia, MO 65202 P [573]214 2677 F [573]214 2714 terracon.com Geotechnical Environmental Construction Materials Facilities
Fuel Groundwater Wells Callaway Nuclear Power Plant
- Reform, Missouri February 12, 2010
- Terracon Project No. 09107004 lrerracan We appreciate the opportunity to provide these services and look forward to continuing our work with you on this project in the future. If you have any questions or comments regarding this data or require additional services, please give me a call.
cientist Environmental Services Attachments : Sampling Field Notes Laboratory Analytical Report Timothy L. Bennett, R.G.
Department Manager Environmental Services
YOUR LAB OF CHOICE Mr. Chris Segafredo Terracon -
Columbia 3601 Mohave Court Suite A Columbia, MO 65202 Report Summary Thursday January 2 8' 2010 Report Number : L441382 Samples Received: 01/21/10 Client Project: 09057159
==
Description:==
Ameren Fuel Wells 12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax I.D. 62-0814289 Est. 1970 The analytical results in this report are based upon information:L lied by you, the client, and are for your exclusivf1 ese If you have questions regarding this data package, please do '?/ hes1t:? to a 1.
Entire Report Reviewed By :
"<<..._:~~~~*~~r=:;~~~~~~~-----
ff Carr, ESC Representat1ve Laboratory Certification Numbers A2LA -
1461- 01, AIHA-100789, AL -
40660, CA -
I-2327, CT -
PH-0197, FL-E87487 GA -
923, IN -
C-TN-01, KY -
90010, KYUST -
0016, NC -
ENV375, DW21704, ND -
R-140 NJ -
TN002, NJ NELAP -
TN002, SC -
84004, TN -
2006, VA -
00109, WV -
233 AZ -
0612, MN -
047-999-395, NY -
11742, WI -
998093910 Accreditation is only applicable to the test methods specified on each scope of accreditation held by ESC Lab Sciences.
This report may not be reproduced, except in full, without written approval from Environmental Science Corp.
Where applicable, sampling conducted by ESC is performed per guidance provided in laboratory standard operating procedures: 060302, 060303, and 060304.
2 Samples Reported : 01/28/10 09:55 Printed: 01/28 / 10 09:55 Page 1 of 9
-ESC YOUR LAB OF CHOICE REPORT OF ANALYSIS Mr. Chris Segafredo Terracon -
Columbia 3601 Mohave Court Columbia, MO 65202 Date Received Description Sample ID Collected By Collection Date Parameter Benzene Toluene Ethylbenzene Total Xylene January 21, 2010 Ameren Fuel Wells MW 937A Hugh Murrell 01/19/10 14:39 Methyl tert-butyl ether TPH (GC/FID) Low Fraction OA1 Surrogate(70-130) a,a,a-Trifluorotoluene(FID) a,a,a-Trifluorotoluene(PID)
Mineral Spirits Kerosene (C9-C16)
Diesel (C7-C26) i6 Fuel Oil (C10-C32)
Hydraulic Fluid (C12-C33)
Motor Oil (C16-C40)
Surrogate recovery(%)
o-Terphenyl BDL -
Below Detection Limit Result BDL BDL 0.00099 BDL BDL BDL 11 2 0 114 0 BDL BDL 0.10 BDL BDL BDL 84.8 Det. Limit-Practical Quantitation Limit(PQL)
Note:
Det. Limit 0.00050 0.0050 0.00050 0.0015 0.0050 0.10 0.10 0.10 0.10 0.10 0.10 0.50 Units mg/1 mg /1 mg/1 mg/1 mg/1 mg/1
% Rec.
% Rec.
mg/1 mg/1 mg/1 mg/1 mg/1 mg/1
% Rec.
The reported analytical results relate only to the sample submitted.
12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax I.D. 62-0814289 Est. 1970 January 28, 2010 ESC Sample L441382-01 Site ID Project # :
09057159 Method Date Dil.
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
8021/0A1 01/22/10 1
OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 This report shall not be reproduced, except in full, without the written approval from ESC.
Reported: 01/28/10 09:55 Printed: 01/28/10 09:55 Page 2 of 9
L*A
- B S*C
- I
- E*N
- C
- E*S YOUR LA!3 OF CHOICE REPORT OF ANALYSIS Mr. Chris Segafredo Terracon -
Columbia 3601 Mohave Court Columbia, MO 65202 Date Received Description Sample ID Collected By Collection Date Parameter Benzene Toluene Ethylbenzene Total Xylene January 21, 2010 Ameren Fuel Wells MW 937C Hugh Murrell 01/19/10 13:42 Methyl tert-butyl ether TPH (GC/FID) Low Fraction OA1 Surrogate(70-130) a,a,a-Trifluorotoluene(FID) a,a,a-Trifluorotoluene(PID)
Mineral Spirits Kerosene (C9-Cl6)
Diesel (C7-C26) t6 Fuel Oil (C10-C32)
Hydraulic Fluid (Cl2-C33)
Motor Oil (Cl6-C40)
Surrogate recovery(%)
o-Terphenyl BDL -
Below Detection Limit Result 0.0024 BDL 0.0012 0.0018 BDL BDL 99.2 103.
BDL BDL 2.4 BDL BDL BDL 86.1 Det. Limit -
Practical Quantitation Limit(PQL)
Note:
Det. Limit 0.00050 0.0050 0.00050 0.0015 0.0050 0.10 0.10 0.10 0. 10 0.10 0.10 0.50 Units mg/1 mg/1 mg/1 mg/1 mg/1 mg/1
% Rec.
% Rec.
mg/1 mg/1 mg/1 mg/1 mg/1 mg/1
% Rec.
The reported analytical results relate only to the sample submitted.
12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax I.D. 62-0814289 Est. 1970 January 28, 2010 ESC Sample L441382-02 Site ID Project, :
09057159 Method Date Oil.
8021/0A1 01/26/10 1
8021/0A1 01/26/10 1
8021/0A1 01/26/10 1
8021/0Al 01/26/10 1
8021/0A1 01/26/10 1
8021/0A1 01/27/10 1
8021/0A1 01/27/10 8021/0Al 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 OA2 01/26/10 This report shall not be reproduced, except in full, without the written approval from ESC.
Reported: 01/28/10 09:55 Printed: 01/28/10 09:55 Page 3 of 9
Sample Number L4413B2-02 Work Group WG460552 Attachment A List of Analytes with QC Qualifiers Sample Type Analyte SAMP Methyl tert-butyl ether Run ID Rl09106B Qualifier J6 Page 4 of 9
Qualifier J6 Meaning Attachment B Explanation of QC Qualifier Codes The sample matrix interfered with the ability to make any accurate determination; spike value is low Qualifier Report Information ESC utilizes sample and result qualifiers as set forth by the EPA Contract Laboratory Program and as required by most certifying bodies including NELAC.
In addition to the EPA qualifiers adopted by ESC, we have implemented ESC qualifiers to provide more information pertaining to our analytical results.
Each qualifier is designated in the qualifier explanation as either EPA or ESC.
Data qualifiers are intended to provide the ESC client with more detailed information concerning the potential bias of reported data.
Because of the wide range of constituents and variety of matrices incorporated by most EPA methods,it i s common for some compounds to fall outside of established ranges.
These exceptions are evaluated and all reported data is valid and useable unless qualified as 'R' (Rejected).
Definitions Accuracy -
The relationship of the observed value of a known sample to the true value of a known sample.
Represented by percent recovery and relevant to samples such as: control samples, matrix spike recoveries, surrogate recoveries, etc.
Precision -
The agreement between a set of samples or between duplicate samples.
Relates to how close together the results are and is represented by Relative Percent Differrence.
Surrogate - Organic compounds that are similar in chemical composition, extraction, and chromatography to analytes of interest.
The surrogates are used to determine the probable response of the group of analytes that are chem-ically related to the surrogate compound.
Surrogates are added to the sample and carried through all stages of preparation and analyses.
- Tentatively Identified Compound: Compounds detected in samples that are not target compounds, internal standards, system monitoring compounds, or surrogates.
Page 5 of 9
TSR Signing Reports: 206 R5 -
Desired TAT Summary of Remarks For Samples Printed 01/28/10 at 09 : 55:34 Sample: 1441382-01 Account: TERRCMO Received: 01/21/10 09:00 Due Date: 01/28/10 00:00 RPT Date: 01/28/10 09:55 Sample: 1441382-02 Account: TERRCMO Received: 01/21/10 09:00 Due Date: 01/28/10 00:00 RPT Date: 01/28/10 09:55
YOUR LAS O F" CHOICE Terracon - Columbia Mr. Chris Segafredo 3601 Mohave Court Suite A Columbia, MO 65202 Analyte Benzene Ethylbenzene Methyl tert-butyl ether Toluene TPH (GC/FID) Low Fraction Total Xylene a,a,a-Trifluorotoluene{FID) a,a,a-Trifluorotoluene(PID) t6 Fuel Oil (Cl0-C32)
Diesel (C7-C26)
Hydraulic Fluid (C12-C33)
Kerosene (C9-Cl6)
Mineral Spirits Motor Oil (Cl6-C40) o-Terphenyl Benzene Ethylbenzene Methyl tert-butyl ether Toluene Total Xylene a,a,a-Trifluorotoluene(PID}
TPH (GC/FID) Low Fraction a,a,a-Trifluorotoluene(FID)
Analyte Benzene Ethylbenzene Methyl tert-butyl ether Toluene Total Xylene a,a,a-Trifluorotoluene(PID}
TPH (GC/FID) Low Fraction a,a,a-Trifluorotoluene(FID)
Diesel (C7-C26)
Motor Oil (Cl6-C40) o-Terpheny1 Benzene Ethylbenzene Methyl tert-botyl ether Toluene Total Xylene a,a,a-Trifluorotoluene(PID)
TPH (GC/FID) Low Fraction a,a,a-Trifluorotoluene(FID)
Result
<.0005
<. 0005
<.005
<.005
<.1
<. 0015
<.1
<. 1
<. 1
<.1
<.1
<.25
<.0005
<.0005
<.005
<.005
<. 0015
<.1 Units mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 Quality Assurance Report Level II L441382 Laboratory Blank Units mg/1 mg/1 mg/1 mg/1 mg/1 mg/1
% Rec.
% Rec.
mg/1 mg/1 mg/1 mg/1 mg/1 mg/1
\\ Rec.
mg/1 mg/1 mg/1 mg/1 mg/1
% Rec.
mg/1
\\ Rec.
Laboratory Known Val
.05
.05
.05
.05
. 15 5.5
.75
.75
.05
.05
.05
.05
.15 5.5
% Rec 110.6 112. 6 84.63 100.7 100.8 Control Sample Result 0.0508
- 0. 0514 0.0533 0.0517 0.156 6.12 0.622
- 0. 614 0.0472 0.0504
- 0. 0492 0.0488 0.146 6.23
- Performance of this Analyte is outside of established criteria.
Limit 62-128 55-122 50-150 55-122 62-128
\\ Rec 102.
103.
107.
103.
104.
112.4 111.
108.4 83. 0 81.8 73.20 94.5 101.
98.4 97.5 97.3 99.20 1
113.
109.9 For additional information, please see Attachment A 'List of Analytes with QC Qualifiers.'
Page 6 of 9 12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax I.D. 62-0814289 Est. 1970 January 28, 2010 Batch Date Analyzed WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460050 01/22/10 06:42 WG460085 01/26/10 13: 48 WG460085 01/26/10 13:48 WG460085 01/26/10 13:48 WG460085 01/26/10 13: 48 WG460085 01/26/10 13:48 WG460085 01/26/10 13:48 WG460085 01/26/10 13:48 WG460552 01/26/10 19:46 WG460552 01/26/10 19:46 WG460552 01/26/10 19:46 WG460552 01 /26/ 10 19:46 WG460552 01/26/10 19:46 WG460552 01/26/10 19:46 WG460732 01/27/10 15:30 WG460732 01/27/10 15:30 Limit Batch 79-114 WG460050 80-116 WG460050 64-125 WG460050 79-112 WG460050 84-118 WG460050 55-122 WG460050 70-124 WG460050 62-128 WG460050 50-150 WG4 60085 50-150 WG460085 50-150 WG460085 79-114 WG460552 80-116 WG460552 64-125 WG460552 79-112 WG460552 84-118 WG460552 55-122 WG460552 70-124 WG460732 62-128 WG460732
YOU~ LAB OF CHOICE Terracon -
Columbia Mr. Chris Segafredo 3601 Mohave Court Quality Assurance Report Suite A Level II Columbia, MO 6S202 L441382 Laboratory Cont rol Sample Duplicate Analyte Units Result Ref
\\Rec Benzene mg/1 0.0483 O.OS08 97.0 E:thylbenzene mg/1 0.048S O.OS14 97.0 Methyl tert-butyl ether mg/1 0.0500 O.OS33 100.
Toluene mg/1 0.0487
- 0. OS17 97.0 Total Xylene mg/1 0.148 0.1S6 98.0 a,a,a-Trifluorotoluene(PID) 110.6 TPH (GC/FID) Low Fraction mg/1 6.20 6.12 113.
a,a,a-Trifluorotoluene(FID) 107.1 Diesel (C7-C26) mg/1
- 0. 647
- 0. 622 86.0 Motor Oil (Cl6-C40) mg/1
- 0. 677 0.614 90.0 o-Terphenyl 82.73 Benzene mg/l 0.0463
- 0. 04 72 92.0 Ethylbenzene mg/1 0.0497 O.OS04 99.0 Methyl tert-butyl ether mg/1 0.0486 0.0492 97.0 Toluene mg/1 0.0477 0.0488 9S.O Total Xylene mg/1 0.144 0.146 96.0 a, a,a-Trifluorotoluene(PID) 99.40 TPH (GC/FID) Low Fraction mg/l
- 6. 22 6.23 113.
a, a, a-Trifluorotoluene(FID) 103.6 Matrix Spike Analyte Units MS Res Ref Res TV
\\ Rec Benzene mg/1 0.049S 0
.OS 99.0 Ethylbenzene mg/1 0.04SO 0.000990
.OS 88.0 Methyl tert-butyl ether mg/l 0.037S 0
.OS 74.9 Toluene mg/1 0.0477 0
.OS 9S. 4 Total Xylene mgll 0.130
.lS 86.S a,a,a-Trifluorotoluene(PID) 111.9 TPH (GC/FID) Low Fraction mg/1 S.20 s.s 94.6 a,a,a-Trifluorotoluene(FID}
lOO.S Benzene mg/1 0.0448 0.00240
.OS 84.8 Ethylbenzene mg/1 0.0390 0.00120
.OS 7S.6 Methyl tert-butyl ether mg/1
- 0. 00712 0
.OS 14.2*
Toluene mgll
- 0. 041S 0
.OS 83. 1 Total Xylene mg/1 0.0990 0.00180
.lS 64.8 a, a,a-Trifluorotoluene(PID) 98.77 TPH (GC/FID) Low Fraction mg/1 66.9 S.60 s.s 112.
- a, a,a-Trifluorotoluene(FID}
106. 1 Matrix Spike Duplicate Analyte Units MSD Ref
\\Rec Limit Benzene mg/1 0.049S 0.049S 99. 1 3S-147 Ethylbenzene mg/1 0.04SO 0.04SO 87.9 39-141 Methyl tert-butyl ether mg/1 0.0316 0.037S 63.1 37-147 Toluene mg/1 0.0474 0. 0477 94.8 3S-148 Total Xylene mg/l 0.128 0.130 8S.3 33-151 a,a,a-Trifluorotoluene(PID}
112.2 SS-122 TPH (GC/FID) Low Fraction mg/1 S. 41 5.20 98.3 SS-109
- Performance of this Analyte is outside of established criteria.
For additional information, please see Attachment A 'List of Analytes with QC Page 7 of 9 imit p-114 80-116 r-12S 9-112 4-118 SS-122 10-124 62-128
~0-lSO 0-lSO t O-lSO
?9-114 80-116
~4-12S r-112 4-118 S-122 70-124 F-128 L1mit 3S-147 39-141 37-147 3S-148 33-151 SS-122 5S-109 62-128 3S-147 39-141 37-147 3S-148 33-1S1 SS-122 SS-109 62-128 RPD 0.11S
- 0. 120 17.1 0.638
- 1. 30 3.86 Qualifiers.'
12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 7S8-S8S8 l-800-767-S859 Fax (61S) 7S8-S8S9 Tax !.D. 62-0814289 Est. 1970 January 28, 2010 RPD Limit Batch s.os 20 WG460050 S.80 20 WG4600SO 6.S2 20 WG4600SO 6.08 20 WG4600SO S.S9 20 WG4600SO WG4600SO 1.30 20 WG4600SO WG4600SO 3.94 20 WG46008S 9.78 2S WG46008S WG46008S 2.06 20 WG460SS2 1.43 20 WG460SS2 1.12 20 WG460SS2 2.20 20 WG460SS2 0.993 20 WG460SS2 WG460SS2 0.271 20 WG460732 WG460732 Ref Samp Batch L441382-01 WG4600SO L441382-01 WG4600SO L441382-0l WG4600SO L441382-0l WG460050 L441382-01 WG4600SO WG4600SO L44l382- 01 WG4600SO WG4600SO L441382-02 WG460SS2 L441382-02 WG460SS2 L441382-02 WG460SS2 L441382-02 WG460SS2 L441382 - 02 WG460SS2 WG460SS2 L441723-08 WG460732 WG460732 Limit Ref Samp Batch 20 L441382-01 WG4600SO 20 L44l382-01 WG4600SO 20 L441382-0l WG4600SO 20 L44l382 - 01 WG4600SO 20 L4 41382-01 WG4600SO WG4600SO 20 L441382-0l WG4600SO
S*C
- I
- E*N
- C
- E
- S YOUR LAB OF CHOICE Terracon - Columbia Mr. Chris Segafredo 3601 Mohave Court Suite A Columbia, MO 65202 Analyte a,a, a-Trifluorotoluene(FID)
Benzene Ethylbenzene Methyl tert-butyl ether Toluene Total Xylene a,a,a-Trifluorotoluene(PID)
TPH (GC/FID) Low Fraction a,a,a-Trifluorotoluene(FID)
Units mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 Quality Assurance Report Level II L441382 Matrix Spike Duplicate MSD Ref 0.0437 0.0448 0.0397 0.0390 0.00807 0.00712 0.0409 0.0415 0. 100 0.0990 66.5 66.9
\\Rec 101.0 82.7 77.0 16.1*
81.7 65.6 99 0 46 111.*
103.0 Batch number /Run number I Sample number cross reference WG460050: Rl087048: L441382-01 WG460085 : R1090448: L441382-01 02 WG460552 : Rl091068: L441382-02 WG460732: Rl091548: L4 41382-02
- Calculations are performed prior to rounding of reported values Performance of this Analyte is outside of esta.blished criteria.
Limit 62-128 35-147 39-141 37-147 35-148 33-151 55-122 55-109 62-128 RPD 2 0 46
- 1. 75 12.6 1.66
- l. 24 0. 656 For additional information, please see Attachment A 'List of Analytes with QC Qualifiers.'
Page 8 of 9 12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax J.D. 62-0814289 Est. 1970 January 28, 2010 Limit Ref Samp Batch 20 L441382-02 WG460552 20 L441382-02 WG460552 20 L441382-02 WG460552 20 L441382-02 WG460552 20 L441382-02 WG460552 WG460552 20 L441723-08 WG460732 WG460732
S*C*I
- E*N
- C
- E*S YOUR LAB OF CHOICE Terracon -
Columbia Mr. Chris Segafredo 3601 Mohave Court Suite A Columbia, MO 65202 Quality Assurance Report Level II L4 41382 The data package includes a summary of the analytic results of the quality control samples required by the SW-846 or CWA methods.
The quality contro ~
samples include a method blank, a laboratory control sample, and the matri spike/matrix spike duplicate analysis.
If a target parameter is outside the method limits, every sample that is effected is flagged with the appropriate qualifier in Appendix B of the analytic report.
Method Blank -
an aliquot of reagent water carried through the entire analytic process.
The method blank results indicate if any possible contamination exposure during the sample handling, digestion or extraction process, and analysis.
Concentrations o target analytes above the reporting limit in the method blank ar qualified with the 8" qualifier.
Laboratory Control Sample - is a sample of known concentration that is carried through the digestion/extraction and analysis process.
The percent recovery, expressed as a percentage of the theoretical concentration, has statistical control limits indicating that the analytic process is "in control".
If a target analyte is outside the control limits for the laboratory control sample or any other control sample, the parameter is flagged with a J4 qualifier for all effected samples.
Matrix Spike and Matrix Spike Duplicate
- is two aliquots of an environmental sample that is spiked with known concentrations of target analytes.
The percent recovery of the target analytes also has statistical control limits.
If any recoveries that are outside the method control limits, the sample that was selected for matrix spike/matrix spike duplicate analysis is flagged with either a JS" or a "J6".
The relative percent difference ('RPD) between the matrix spike and the matrix spike duplicate recoveries is all calculated.
If the RPD is above the method limit, the effected samples are flagged with a "J3" qualifier.
Page 9 of 9 12065 Lebanon Rd.
Mt. Juliet, TN 37122 (615) 758-5858 1-800-767-5859 Fax (615) 758-5859 Tax I.D. 62-0814289 Est. 1970 January 28, 2010
Terrtrcon-Columbia 3601 Mohave Court Columbia,MO 65202 Report to:
Mr. Chris Se2afredo Billing information:
Accounts Payable 3601 Mohave Court Suite A Columbia,MO 65202 Emait Ameren Fuel Wells
/f),'$swt-r'
- Matrix: SS - Soil Remarks:
Next Day........*........ 100%
_Two Day........*......... 50%
_Three Day................. 25%
Date Results Needed Email?
_No FAX? _No
_Yes GW-Groundwater WW - WasteWater OW - Drinking Water OT - Other _ ___ _
L135 5_ q;_ql-, s:<sv C237 Chain of Custody Pagel_ or~
-ESC L - A - B S
- C E
- N ; C
- E *.S l206S ~banon Road Mt..Juliet, TN 37121 Phone: (900) 767*5859 Phone: (615) 7$8-5858 fa~(61Sl7S8-5859 pH Temp
- Flow Other