Enclosure 39 to ULNRC-05893 - Burns & Mcdonnell (Burns and Mcdonnell Engineering Company) 2008. Phase II Hydrogeologic Investigation Report Collector Well Siting Study, Callaway Unit 2. June (Part 3 of 3)
ML12271A478
Person / Time
Site: Callaway 
(NPF-030)
Issue date: 06/30/2008
From: Higgins P
Burns & McDonnell Engineering Co
To: Grothe T
Office of Nuclear Reactor Regulation, Ameren Corp, AmerenUE
References
ULNRC-05893
Download: ML12271A478 (174)


Text

{{#Wiki_filter:APPENDIX C WATER QUALITY DATA

November 20, 2007 PAT HIGGINS BURNS & MCDONNELL 9400 WARD PARKWAY Kansas City, MO 64114 RE : Project: Callaway Pace Project No.. 6031330

Dear PAT HIGGINS:

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Enclosed are the analytical results for sample(s) received by the laboratory on November 09, 2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, . ll.,,.../...--, l..JrWifJ,_.()..I /}1---- Angie Brown Angie.Brown@pacelabs.com Project Manager A2LA Certification Number: 2456.01 Arkansas Certification Number: 05-008-0 Illinois Certification Number: 001191 Iowa Certificalion Number: 118 Kansas/NELAP Certificalion Number: E-1 0116 Louisiana Certificalion Number: 03055 Oklahoma Certification Number: 9205/9935 Utah Certificalion Number: 9135995665 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Page 1 of 23

Project: Callaway Pace Project No.: 6031330 LabiD Sample ID 6031330001 TW-01 6031330002 TW-01 MID SAMPLE

SUMMARY

Matrix Date Collected Date Received Water 11/08/07 10:30 11/09/07 17:35 Water 11/08/07 13:00 11/09/07 17:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Page 2 of 23

Project: Callaway Pace Project No.: 6031330 LabiD Sample ID 6031330001 TW-01 6031330002 TW-01 MID SAMPLE ANALYTE COUNT Method EPA 120.1 EPA 180.1 EPA 300.0 EPA365.1 EPA365.4 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM4500-H+8 SM 52108 SM 5310C EPA 120.1 EPA 180.1 EPA 300.0 EPA365.1 EPA365.4 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM4500-H+8 SM 52108 SM 5310C REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Analytes Reported 4 8 3 4 8 3 Lenexa, KS 66219 (913)599-5665 Page 3 of 23

Project: Callaway Pace Project No.: 6031330 Sample: TW-01 Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (CaC03) Alkalinity, Carbonate (CaCO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 4500H+ pH, Electrometric pH at 25 Degrees C 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 365.1 Phosphate, Ortho as P Orthophosphate as P Date: 11/20/2007 05:08PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Lab ID: 6031330001 Collected: 11/08/07 10:30 Received: 11/09/07 17:35 Matrix: Water Results Units Report Limit DF Prepared Analyzed CAS No. Qual Analytical Method: EPA 6010 Preparation Method: EPA 3010 1220 ug/L 10.0 11/12/07 00:00 11/13/07 09:30 7440-39-3 137000 ug/L 100 11/12/07 00:00 11/13/07 09:30 7440-70-2 7990 ug/L 50.0 11/12/07 00:00 11/13/07 09:30 7439-89-6 36100 ug/L 50.0 11/12/07 00:00 11/13/07 09:30 7439-95-4 1300 ug/L 5.0 11/12/07 00:00 11/13/07 09:30 7439-96-5 4970 ug/L 500 11/12/07 00:00 11/13/07 09:30 7440-09-7 21600 ug/L 500 11/12/07 00:00 11/13/07 09:30 7440-23-5 821 ug/L 10.0 11/12/07 00:00 11/13/07 09:30 7440-24-6 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/16/07 00:00 11/19/07 10:28 7439-89-6 Analytical Method: EPA 120.1 886 umhos/cm 1.0 11/13/07 00:00 Analytical Method: EPA 180.1 106 NTU 5.0 11/1 0/07 10:00 Analytical Method: SM 2320B 626 mg/L 20.0 11/14/07 12:57 ND mg/L 20.0 11/14/07 12:57 626 mg/L 20.0 11/14/07 12:57 Analytical Method: SM 2540C 592 mg/L 5.0 11/13/07 18:26 Analytical Method: SM 2540D 15.0 mg/L 5.0 11/13/07 14:19 Analytical Method: SM 4500-H+B 7.5 Std. Units 0.10 11/10/07 13:00 H6 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/10/07 10:09 11/15/07 13:12 Analytical Method: EPA 300.0 ND mg/L 1.0 Analytical Method: EPA 300.0 18.5 mg/L 5.0 5 1.1 mg/L 1.0 5 57.7 mg/L 5.0 5 Analytical Method: EPA 365.1 ND mg/L 0.10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 11/10/07 11:50 14797-55-8 H1 11/12/07 19:09 16887-00-6 11/12/07 19:09 16984-48-8 11/12/0719:09 14808-79-8 11/10/07 12:59 H1 Page4 of 23

Project: Callaway Pace Project No.: 6031330 Sample: TW-01 Parameters 365.4 Total Phosphorus Phosphorus 5310C TOC Total Organic Carbon Date: 11/20/2007 05:08PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 LabiD: 6031330001 Collected: 11/08/07 10:30 Received: 11/09/07 17:35 Matrix: Water Results Units Analytical Method: EPA 365.4 0.20 mg/L Analytical Method: SM 5310C 2.6 mg/L Report Limit DF Prepared 0.10 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analyzed CAS No. Qual 11/14/07 12:26 7723-14-0 11/14/07 00:00 7440-44-0 Page 5 of 23

Project: Callaway Pace Project No.: 6031330 Sample: TW-01 MID Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (CaC03) Alkalinity, Carbonate (CaCO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 4500H+ pH, Electrometric pH at 25 Degrees C 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 365.1 Phosphate, Ortho as P Orthophosphate as P Date: 11/20/2007 05:08PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Lab ID: 6031330002 Collected: 11/08/07 13:00 Received: 11/09/07 17:35 Matrix: Water Results Units Report Limit DF Prepared Analyzed CAS No. Analytical Method: EPA 6010 Preparation Method: EPA 3010 1300 ug/L 10.0 11/12/07 00:00 11/13/07 09:34 7440-39-3 145000 ug/L 100 11/12/07 00:00 11/13/07 09:34 7440-70-2 11600 ug/L 50.0 11/12/07 00:00 11/13/07 09:34 7439-89-6 37000 ug/L 50.0 11/12/07 00:00 11/13/07 09:34 7439-95-4 1410 ug/L 5.0 11/12/07 00:00 11/13/07 09:34 7439-96-5 4720 ug/L 500 11/12/07 00:00 11/13/07 09:34 7440-09-7 14200 ug/L 500 11/12/07 00:00 11/13/07 09:34 7440-23-5 815 ug/L 10.0 11/12/07 00:00 11/13/07 09:34 7440-24-6 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/16/07 00:00 11/19/07 10:33 7439-89-6 Analytical Method: EPA 120.1 902 umhos/cm 1.0 11/13/07 00:00 Analytical Method: EPA 180.1 152 NTU 5.0 11/1 0/07 10:00 Analytical Method: SM 2320B 589 mg/L 20.0 11/14/07 13:04 ND mg/L 20.0 11/14/07 13:04 589 mg/L 20.0 11/14/07 13:04 Analytical Method: SM 2540C 598 mg/L 5.0 11/13/07 18:27 Analytical Method: SM 2540D 25.0 mg/L 5.0 11/13/07 14:20 Analytical Method: SM 4500-H+B 7.6 Std. Units 0.10 11/10/07 13:00 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/10/07 12:03 11/15/07 13:16 Analytical Method: EPA 300.0 ND mg/L 1.0 Analytical Method: EPA 300.0 17.6 mg/L 5.0 5 1.2 mg/L 1.0 5 41.2 mg/L 5.0 5 Analytical Method: EPA 365.1 ND mg/L 0.10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 11/10/07 12:03 14797-55-8 11/12/07 19:22 16887-00-6 11/12/07 19:22 16984-48-8 11/12/0719:22 14808-79-8 11/10/07 12:56 Qual H6 Page 6 of 23

Project: Callaway Pace Project No.: 6031330 Sample: TW-01 MID Parameters 365.4 Total Phosphorus Phosphorus 5310C TOC Total Organic Carbon Date: 11/20/2007 05:08PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 LabiD: 6031330002 Collected: 11/08/07 13:00 Received: 11/09/07 17:35 Matrix: Water Results Units Analytical Method: EPA 365.4 0.33 mg/L Analytical Method: SM 5310C 3.1 mg/L Report Limit DF Prepared 0.10 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analyzed CAS No. Qual 11/14/07 12:29 7723-14-0 11/14/07 00:00 7440-44-0 Page 7 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WETA/5762 QC Batch Method: EPA300.0 Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252066 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Nitrate as N mgil LABORATORY CONTROL SAMPLE: 252067 Parameter Units Nitrate as N mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 252068 6031260003 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

Blank Result Reporting Limit EPA300.0 300.0 IC Anions Qualifiers ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.7 95 252069 MS MSD Spike Spike MS MSD %Rec Limits 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L SAMPLE DUPLICATE* 252070 Parameter Units Nitrate as N mgil Date: 11/20/2007 05:08PM 25.0 5 6031260002 Result 7.6 5 29.0 Dup Result 7.6 29.0 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 79 Max RPD 79 11 61-128 0 7 Qualifiers Page 8 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WETA/5764 QUALITY CONTROL DATA Analysis Method: EPA365.1 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QC Batch Method: EPA 365.1 Analysis

Description:

365.1 Phosphorus, Ortho Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252406 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Orthophosphate as P mgil LABORATORY CONTROL SAMPLE: 252407 Parameter Units Orthophosphate as P mgil MATRIX SPIKE SAMPLE: 252408 Parameter Units Orthophosphate as P mgil SAMPLE DUPLICATE: 252409 Parameter Units Orthophosphate as P mgil Date: 11/20/2007 05:08PM Blank Result Spike Cone. 2 ND 6031330002 Result Reporting Limit LCS Result 2.0 Spike Cone. 0.10 ND 2 6031330002 Result ND Dup Result ND Qualifiers LCS % Rec 102 MS Result RPD 2.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 %Rec Limits 90-110 MS %Rec 102 Max RPD Qualifiers % Rec Limits 90-110 Qualifiers 20 Qualifiers Page 9 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9930 QC Batch Method: EPA 180.1 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

EPA 180.1 180.1 Turbidity Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252448 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Turbidity NTU LABORATORY CONTROL SAMPLE: 252449 Parameter Units Turbidity NTU SAMPLE DUPLICATE: 252450 Parameter Units Turbidity NTU Date: 11/20/2007 05:08PM Blank Result Spike Cone. 10 ND 6031330001 Result 106 Reporting Limit LCS Result 9.9 Dup Result 1.0 106 Qualifiers LCS % Rec 99 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 %Rec Limits 80-120 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 10 Page 10 of 23

QUALITY CONTROL DATA Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9932 Analysis Method: SM 5210B QC Batch Method: SM 5210B Analysis

Description:

5210B BOD, 5 day Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252453 Associated Lab Samples: 6031330001, 6031330002 Parameter Units BOD, 5 day mgil LABORATORY CONTROL SAMPLE: 252454 Parameter Units BOD, 5 day mgil SAMPLE DUPLICATE: 252455 Parameter Units BOD, 5 day mgil Date: 11/20/2007 05:08PM Blank Result Spike Cone. 198 ND 6031281003 Result 1180 Reporting Limit LCS Result 187 Dup Result 2.0 1160 Qualifiers LCS % Rec 95 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 2 %Rec Limits 85-115 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 17 Page 11 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9934 QC Batch Method: SM 4500-H+B QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 4500-H+B 4500H+B pH Associated Lab Samples: 6031330001, 6031330002 SAMPLE DUPLICATE: 252458 Parameter Units pH at 25 Degrees C Std. Units Date: 11/20/2007 05:08PM 6031330001 Result 7.5 Dup Result RPD 7.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 5 H6 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 12 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WETA/5775 QC Batch Method: EPA300.0 Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252819 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil LABORATORY CONTROL SAMPLE: 252820 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 252821 6031067002 QUALITY CONTROL DATA Analysis Method: EPA300.0 300.0 IC Anions Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 1.0 ND 0.20 ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.8 96 5 4.9 97 5 5.2 104 252822 MS MSD Spike Spike MS MSD %Rec Limits 90-110 90-110 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Chloride Fluoride Sulfate SAMPLE DUPLICATE: 252823 Chloride Fluoride Sulfate Parameter Date: 11/20/2007 05:08PM mg/L mg/L mg/L mgil mgil mgil Units 16.8 5 5 21.7 21.5 0.41 5 5 5.2 5.2 1.2 5 5 5.8 5.7 6031107001 Dup Result Result RPD 161 165 ND ND 1480 1500 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 97 95 57-123 6 96 95 80-120 10 92 91 60-133 12 Max RPD Qualifiers 2 14 0 13 11 Page 13 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9941 QC Batch Method: SM 2320B QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 2320B 2320B Alkalinity Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252895 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) LABORATORY CONTROL SAMPLE: Parameter Alkalinity, Tolal SAMPLE DUPLICATE: 252897 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) SAMPLE DUPLICATE: 252898 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) Date: 11/20/2007 05:08PM mgil mgil mgil 252896 Units mgil Units mgil mgil mgil Units mgil mgil mgil Blank Result Spike Cone. 500 ND ND ND 6031019002 Result ND 206 206 6031085002 Result ND 703 Reporting Limit LCS Result 541 Dup Result Dup Result 20.0 20.0 20.0 ND 205 205 ND 684 684 Qualifiers LCS % Rec 108 RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 0 0 3 3 %Rec Limits 90-110 Max RPD Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 6 6 6 Qualifiers 6 6 6 Page 14 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: MPRP/5108 QC Batch Method: EPA 3010 Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 252947 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L LABORATORY CONTROL SAMPLE: 252948 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 252949 6031294001 Parameter Units Result Barium ug/L 32.7 Calcium ug/L 50000 Iron ug/L ND Magnesium ug/L 8400 Manganese ug/L ND Potassium ug/L 1160 Sodium ug/L 25100 Strontium ug/L 239 QUALITY CONTROL DATA Analysis Method: EPA6010 6010 MET Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 10.0 ND 100 ND 50.0 ND 50.0 ND 5.0 ND 500 ND 500 ND 10.0 Spike LCS LCS Cone. Result % Rec 1000 1070 107 10000 10700 107 10000 10600 106 10000 10600 106 1000 1100 110 10000 9990 100 10000 10200 102 1000 1040 104 252950 MS MSD Spike Spike MS MSD Cone. Cone. Result Result 1000 1000 1110 1070 10000 10000 58800 60200 10000 10000 10300 10200 10000 10000 18400 18400 1000 1000 1110 1090 10000 10000 10900 11000 10000 10000 34500 35000 1000 1000 1250 1270 Date: 11/20/2007 05:08PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Limits Qualifiers 80-120 80-120 80-120 80-120 80-120 80-120 80-120 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 108 104 75-125 4 7 88 102 75-125 2 8 103 102 75-125 12 100 100 75-125 0 7 111 108 75-125 2 9 98 99 75-125 7 93 99 75-125 2 12 101 103 75-125 2 11 Page 15 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: WETA/5781 QUALITY CONTROL DATA Analysis Method: SM 5310C Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QC Batch Method: SM 5310C Analysis

Description:

5310C Total Organic Carbon Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 253186 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Total Organic Carbon mgil LABORATORY CONTROL SAMPLE: 253187 Parameter Units Total Organic Carbon mgil MATRIX SPIKE SAMPLE: 253188 Parameter Units Total Organic Carbon mgil SAMPLE DUPLICATE: 253189 Parameter Units Total Organic Carbon mgil Date: 11/20/2007 05:08PM Blank Result Spike Cone. 5 ND 6031330001 Result Reporting Limit LCS Result 5.2 Spike Cone. 1.0 2.6 10 6031330002 Result 3.1 Dup Result 2.9 Qualifiers LCS % Rec 104 MS Result 12.8 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 8 %Rec Limits 79-126 MS %Rec 102 Max RPD Qualifiers % Rec Limits 42-141 Qualifiers 21 Qualifiers Page 16 of 23

QUALITY CONTROL DATA Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9953 Analysis Method: EPA 120.1 QC Batch Method: EPA 120.1 Analysis

Description:

120.1 Specific Conductance Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 253212 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Specific Conductance umhos/cm SAMPLE DUPLICATE: 253213 Parameter Units Specific Conductance umhos/cm Date: 11/20/2007 05:08PM Blank Result ND 6031085002 Result 2000 Reporting Limit 1.0 Dup Result 2000 Qualifiers RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 17 of 23

QUALITY CONTROL DATA Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9963 Analysis Method: SM 2540D QC Batch Method: SM 2540D Analysis

Description:

2540D Total Suspended Solids Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 253446 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 253447 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 253448 Parameter Units Total Suspended Solids mgil Date: 11/20/2007 05:08PM Blank Result ND 6031242001 Result 134 6031237001 Result 26.0 Reporting Limit Dup Result Dup Result 5.0 133 26.0 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 18 of 23

QUALITY CONTROL DATA Project: Callaway Pace Project No.: 6031330 QC Batch: WETA/5788 Analysis Method: EPA365.4 QC Batch Method: EPA 365.4 Analysis

Description:

365.4 Phosphorus Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 253453 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Phosphorus mgil LABORATORY CONTROL SAMPLE: 253454 Parameter Units Phosphorus mgil MATRIX SPIKE SAMPLE: 253455 Parameter Units Phosphorus mgil SAMPLE DUPLICATE: 253456 Parameter Units Phosphorus mgil Date: 11/20/2007 05:08PM Blank Result Spike Cone. 2 ND 6031330001 Result Reporting Limit LCS Result 1.8 Spike Cone. 0.10 0.20 2 6031237001 Result 0.59 Dup Result 0.62 Qualifiers LCS % Rec 92 MS Result RPD 2.1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 4 %Rec Limits 90-110 MS %Rec Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers 97 12 % Rec Limits 58-132 Qualifiers Qualifiers Page 19 of 23

QUALITY CONTROL DATA Project: Callaway Pace Project No.: 6031330 QC Batch: WET/9969 Analysis Method: SM 2540C QC Batch Method: SM 2540C Analysis

Description:

2540C Total Dissolved Solids Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 253551 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 253552 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 253553 Parameter Units Total Dissolved Solids mgil Date: 11/20/2007 05:08PM Blank Result ND 6031428001 Result 836 6031192012 Result 153 Reporting Limit Dup Result Dup Result 5.0 838 153 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 20 of 23

Project: Callaway Pace Project No.: 6031330 QC Batch: MPRP/5155 QUALITY CONTROL DATA Analysis Method: EPA6010 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QC Batch Method: EPA 3010 Analysis

Description:

6010 MET Dissolved Associated Lab Samples: 6031330001, 6031330002 METHOD BLANK: 255416 Associated Lab Samples: 6031330001, 6031330002 Parameter Units Iron ug/L LABORATORY CONTROL SAMPLE: 255417 Parameter Units Iron ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 255418 6031330002 Parameter Units Result Iron ug/L ND Blank Result Spike Cone. 10000 MS Spike Cone. 10000 Reporting Limit ND 50.0 LCS Result 9940 255419 MSD Spike MS Cone. Result 10000 9800 Qualifiers LCS % Rec 99 MSD Result 9490 Date: 11/20/2007 05:08PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits Qualifiers 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 98 95 75-125 3 20 Page 21 of 23

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. QUALIFIERS Project: Callaway Pace Project No.: 6031330 DEFINITIONS DF Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL Adjusted Method Detection Limit. S Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) DUP Sample Duplicate RPD Relative Percent Difference Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. ANALYTE QUALIFIERS H 1 Analysis conducted outside the EPA method holding time. H6 Analysis initiated more than 15 minutes after sample collection. Date: 11/20/2007 05:08PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Lenexa, KS 66219 (913)599-5665 Page 22 of 23

Project: Callaway Pace Project No.: 6031330 LabiD SampleiD 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID 6031330001 TW-01 6031330002 TW-01 MID Date: 11/20/2007 05:08PM Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QUALITY CONTROL DATA CROSS REFERENCE TABLE QC Batch Method QC Batch EPA300.0 WETA/5762 EPA300.0 WETA/5762 EPA365.1 WETA/5764 EPA365.1 WETA/5764 EPA 180.1 WET/9930 EPA 180.1 WET/9930 SM 52108 WET/9932 SM 52108 WET/9932 SM 4500-H+8 WET/9934 SM 4500-H+8 WET/9934 EPA300.0 WETA/5775 EPA300.0 WETA/5775 SM 23208 WET/9941 SM 23208 WET/9941 EPA3010 MPRP/5108 EPA3010 MPRP/5108 SM 5310C WETA/5781 SM 5310C WETA/5781 EPA 120.1 WET/9953 EPA 120.1 WET/9953 SM 25400 WET/9963 SM 25400 WET/9963 EPA365.4 WETA/5788 EPA365.4 WETA/5788 SM 2540C WET/9969 SM 2540C WET/9969 EPA3010 MPRP/5155 EPA3010 MPRP/5155 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analytical Analytical Method Batch SM 52108 WET/9936 SM 52108 WET/9936 EPA6010 ICP/4524 EPA6010 ICP/4524 EPA6010 ICP/4556 EPA6010 ICP/4556 Page 23 of 23

~ eAnafyticar ~w.fl"Ce1abs.c.om Requ~red Client Information: Section A Requi""d Client lnformati<lfl: Section B SAMPLE ID (One character per bmc) t.Wli1L Wator S::.t; Oil V',.!ip9 A!f "Tie.os.ue Otho; Temp InC '{I Rec,.iva<l on Ice

  • J/ N Sealed Cooler 11 N Sample Intact I

/N I Additional Comments: CHAIN-OF-CUSTODY I Analytical Request Document Tfle Chain-of-Custody is a LEGAL DOCUMENT. AH relevant fields must be completed accurately IPage: of J ln'<<li<e lnlarmi!ltion: Section C Client: Section C STATE RG. AGENCV: DESIGN ONLY 'Z>31?)0

Sample Condition Upon Receipt Client Name: ~S f t1'-D Courter: 0 Fed Ex D UPS D USPS 00 Client D Commercial 0 Pace Other Tracking#:-------- Custody Seal on CoolerfBox Present: ~ yes 0 no Seals intact: Da yes D no Packing Material: D Bubble Wrap osubble Bags D None £§!.other "..;::*..;..'.:....PL'-._P_1.._* ___ ..... _----------1 Thermometer Used Tl"-' rl Type of Ice: ~t Blue None 0 Samples on ice cooling process lias begun Cooler Temperature 1-.f./ Biological Tissue is Fro:mn: YIJS No t Date and Initials of person examining contents: ~ \\Clo<>t Temp shoukl be above freezing to 6'C Comments: Chain of Custody Present: ,klves ON~ DNir~ 1. Chain of Custody Filled Out: lirYes ONe ON/A 2. . Chain of Custody Relinquished: tl!fYos ONo DN/A.3. Sampler Name & Signature on COC: ~OS ONe DNIA 4. Samples Arrived within Hold Time: IDYeo UNo ON/A 5. Short Hold Time Analysis (<72hr): I<Svos DNo CJNIA 6....,6) &<.r'{) o(>.!-*1 1!\\.1~6 Ot*.f.k,-f' fvbS1'fftA RuJ:;h Turn Around T:lme Requested: DYes liaNo DNIA 7. Suffici~nt Volume: l!!JYe& D~o DNIA*a. Correct Containers Used: Elves DNo ON/A 9. -Pace Containers Used: ~Yes DNo ON/A Containers Intact: !BYes DNo DNIA 10. Filtered volume received for Dissolved tests DYes lil'~o DNI.A.. 11. Sample Labels match COC: li!:lYeo DNo DNIA.12. -Includes datettime/10/Ana!ysis Matrix: All,cantalnors needing preoorJ~tlon havn been checked. IS!l'Yes ONo UNIA 13. All containers needing preservation are found to be in 'f?.IYoo Ot~o ON/A compliance IA;th EPA recommendation. ClYes DifNo .lniijali'Alen tot# cl added exceptions: VOA. ootiform. TOG, O&G, WI*DRO (wnter) oornpleted preservative Samples checked for dechlorlnatlon: DYes DNo fflNIA 14. Headspace in VOAVials ( :>6mm}: UYeB ON~ ~NIA 15. .Trip Blank Present: DY~s ON~ !liN/A 16. Trip Blank Custody Seals Present DYes ONo :@NIA IMl\\ Pace Trip Blank lot# (if purchased}:. ( ~Required? ll 1-z.ldi Y I N Pniljeet Manager Revi'ew.: Date:


~---

Note: Whenever there is a discrepancy affecting North Caronna compliance samptes, a copy of this form will be sent ta the North Carolina DEHNR Certification Office ( I.e out of hold*, incorrect preservative, out of temp, Incorrect containers) f'*ALLC003rev.3, 11Septambel'200&

November 20, 2007 PAT HIGGINS BURNS & MCDONNELL 9400 WARD PARKWAY Kansas City, MO 64114 RE : Project: AMEREN 46691-CALLAWAY Pace Project No.. 6031376

Dear PAT HIGGINS:

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Enclosed are the analytical results for sample(s) received by the laboratory on November 12, 2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, . ll.,,.../...--, l..JrWifJ,_.()..I /}1---- Angie Brown Angie.Brown@pacelabs.com Project Manager A2LA Certification Number: 2456.01 Arkansas Certification Number: 05-008-0 Illinois Certification Number: 001191 Iowa Certificalion Number: 118 Kansas/NELAP Certificalion Number: E-1 0116 Louisiana Certificalion Number: 03055 Oklahoma Certification Number: 9205/9935 Utah Certificalion Number: 9135995665 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Page 1 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 LabiD Sample ID 6031376001 TW-01 END SAMPLE

SUMMARY

Matrix Date Collected Date Received Water 11/11/07 07:15 11/12/07 09:55 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Page 2 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 LabiD Sample ID 6031376001 TW-01 END SAMPLE ANALYTE COUNT EPA 120.1 EPA 180.1 EPA 300.0 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM4500-H+8 SM 52108 SM 5310C Method REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Analytes Reported 4 8 3 Lenexa, KS 66219 (913)599-5665 Page 3 of 18

ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 Sample: TW-01 END Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (CaC03) Alkalinity, Carbonate (CaCO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 4500H+ pH, Electrometric pH at 25 Degrees C 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 5310C TOC Total Organic Carbon Date: 11/20/2007 05:10PM Lab ID: 6031376001 Collected: 11/11/07 07:15 Received: 11/12/07 09:55 Matrix: Water Results Units Report Limit DF Prepared Analyzed CAS No. Analytical Method: EPA 6010 Preparation Method: EPA 3010 1240 ug/L 10.0 11/13/07 00:00 11/13/07 14:49 7440-39-3 150000 ug/L 100 11/13/07 00:00 11/13/07 14:49 7440-70-2 12800 ug/L 50.0 11/13/07 00:00 11/13/07 14:49 7439-89-6 35600 ug/L 50.0 11/13/07 00:00 11/13/07 14:49 7439-95-4 1320 ug/L 5.0 11/13/07 00:00 11/13/07 14:49 7439-96-5 4560 ug/L 500 11/13/07 00:00 11/13/07 14:49 7440-09-7 13000 ug/L 500 11/13/07 00:00 11/13/07 14:49 7440-23-5 834 ug/L 10.0 11/13/07 00:00 11/15/07 16:25 7440-24-6 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/16/07 00:00 11/19/07 10:46 7439-89-6 Analytical Method: EPA 120.1 923 umhos/cm 1.0 11/13/07 00:00 Analytical Method: EPA 180.1 184 NTU 5.0 11/12/07 16:15 Analytical Method: SM 2320B 614 mg/L 20.0 11/14/07 17:26 ND mg/L 20.0 11/14/07 17:26 614 mg/L 20.0 11/14/07 17:26 Analytical Method: SM 2540C 584 mg/L 5.0 11/15/07 15:33 Analytical Method: SM 2540D 30.0 mg/L 5.0 11/15/07 14:09 Analytical Method: SM 4500-H+B 7.0 Std. Units 0.10 11/12/07 16:00 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/12/07 16:34 11/17/07 16:06 Analytical Method: EPA 300.0 ND mg/L 1.0 Analytical Method: EPA 300.0 3.5 mg/L 1.0 0.25 mg/L 0.20 9.0 mg/L 1.0 Analytical Method: SM 5310C 2.7 mg/L 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 11/12/07 15:33 14797-55-8 11/14/07 23:53 16887-00-6 11/14/07 23:53 16984-48-8 11/14/07 23:53 14808-79-8 11/14/07 00:00 7440-44-0 Qual H6 Page4of18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WETA/5780 QC Batch Method: EPA300.0 Associated Lab Samples: 6031376001 METHOD BLANK: 252989 Associated Lab Samples: 6031376001 Parameter Units Nitrate as N mgil LABORATORY CONTROL SAMPLE: 252990 Parameter Units Nitrate as N mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 252992 6031376001 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

Blank Result Reporting Limit EPA300.0 300.0 IC Anions Qualifiers ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.6 93 252993 MS MSD Spike Spike MS MSD %Rec Limits 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L SAMPLE DUPLICATE* 252991 Parameter Units Nitrate as N mgil Date: 11/20/2007 05:10PM ND 5 6031376001 Result ND 5 Dup Result 4.6 .4J 4.5 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 83 2 Max RPD 83 11 61-128 0 7 Qualifiers Page 5 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9945 QC Batch Method: EPA 180.1 Associated Lab Samples: 6031376001 METHOD BLANK: 253065 Associated Lab Samples: 6031376001 Parameter Units Turbidity NTU LABORATORY CONTROL SAMPLE: 253066 Parameter Units Turbidity NTU SAMPLE DUPLICATE: 253067 Parameter Units Turbidity NTU Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

EPA 180.1 180.1 Turbidity Blank Result Reporting Limit Qualifiers Spike Cone. 10 ND 6031376001 Result 184 LCS Result 10.1 Dup Result 1.0 184 LCS % Rec 101 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 80-120 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 10 Page 6 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9946 QC Batch Method: SM 4500-H+B Associated Lab Samples: 6031376001 SAMPLE DUPLICATE: 253068 Parameter Units pH at 25 Degrees C Std. Units Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

6031376001 Result 7.0 Dup Result SM 4500-H+B 4500H+B pH RPD 7.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD 5 H6 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 7 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9947 QC Batch Method: SM 5210B Associated Lab Samples: 6031376001 METHOD BLANK: 253069 Associated Lab Samples: 6031376001 Parameter Units BOD, 5 day mgil LABORATORY CONTROL SAMPLE: 253070 Parameter Units BOD, 5 day mgil SAMPLE DUPLICATE: 253071 Parameter Units BOD, 5 day mgil Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: SM 5210B Analysis

Description:

5210B BOD, 5 day Blank Result Spike Cone. 198 ND 6031376001 Result ND Reporting Limit LCS Result 182 Dup Result 2.0 ND Qualifiers LCS % Rec 92 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 33 %Rec Limits 85-115 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 17 D7 Page 8 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WETA/5781 QC Batch Method: SM 5310C Associated Lab Samples: 6031376001 METHOD BLANK: 253186 Associated Lab Samples: 6031376001 Parameter Units Total Organic Carbon mgil LABORATORY CONTROL SAMPLE: 253187 Parameter Units Total Organic Carbon mgil MATRIX SPIKE SAMPLE: 253188 Parameter Units Total Organic Carbon mgil SAMPLE DUPLICATE: 253189 Parameter Units Total Organic Carbon mgil Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: SM 5310C Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

5310C Total Organic Carbon Blank Result Spike Cone. 5 ND 6031330001 Result Reporting Limit LCS Result 5.2 Spike Cone. 1.0 2.6 10 6031330002 Result 3.1 Dup Result 2.9 Qualifiers LCS % Rec 104 MS Result 12.8 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 8 %Rec Limits 79-126 MS %Rec 102 Max RPD Qualifiers % Rec Limits 42-141 Qualifiers 21 Qualifiers Page 9 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: MPRP/5114 QC Batch Method: EPA 3010 Associated Lab Samples: 6031376001 METHOD BLANK: 253208 Associated Lab Samples: 6031376001 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L LABORATORY CONTROL SAMPLE: 253209 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 253210 6031264001 Parameter Units Result Barium ug/L 43.1 Calcium ug/L 85700 Iron ug/L 18.6J Magnesium ug/L 11900 Manganese ug/L 0.80J Potassium ug/L 15800 Sodium ug/L 100000 00 Strontium ug/L 892 QUALITY CONTROL DATA Analysis Method: EPA6010 6010 MET Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 10.0 ND 100 ND 50.0 ND 50.0 ND 5.0 ND 500 ND 500 ND 10.0 Spike LCS LCS Cone. Result % Rec 1000 964 96 10000 10800 108 10000 10100 101 10000 9540 95 1000 1010 101 10000 9620 96 10000 9300 93 1000 1010 101 253211 MS MSD Spike Spike MS MSD Cone. Cone. Result Result 1000 1000 995 1000 10000 10000 95500 96000 10000 10000 10000 10100 10000 10000 21300 21500 1000 1000 1010 1020 10000 10000 25900 26000 10000 10000 53800 54100 1000 1000 1920 1880 Date: 11/20/2007 05:10PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Limits Qualifiers 80-120 80-120 80-120 80-120 80-120 80-120 80-120 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 95 96 75-125 7 97 102 75-125 8 100 101 75-125 12 94 95 75-125 7 101 102 75-125 9 101 102 75-125 0 7 -99462 -99459 75-125 12 MO 103 99 75-125 2 11 Page 10 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9953 QC Batch Method: EPA 120.1 Associated Lab Samples: 6031376001 METHOD BLANK: 253212 Associated Lab Samples: 6031376001 Parameter Units Specific Conductance umhos/cm SAMPLE DUPLICATE: 253213 Parameter Units Specific Conductance umhos/cm Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: EPA 120.1 Analysis

Description:

120.1 Specific Conductance Blank Result ND 6031085002 Result 2000 Reporting Limit 1.0 Dup Result 2000 Qualifiers RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 11 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9962 QC Batch Method: SM 2320B Associated Lab Samples: 6031376001 METHOD BLANK: 253424 Associated Lab Samples: 6031376001 Parameter Units Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) LABORATORY CONTROL SAMPLE: Parameter Alkalinity, Tolal SAMPLE DUPLICATE: 253426 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) SAMPLE DUPLICATE: 253427 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) Date: 11/20/2007 05:10PM mgil mgil mgil 253425 Units mgil Units mgil mgil mgil Units mgil mgil mgil QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 2320B 2320B Alkalinity Blank Reporting Result Spike Cone. 500 ND ND ND 6031085003 Result ND 697 697 6031192001 Result 53.5 68.6 Limit LCS Result 516 Dup Result Dup Result 20.0 20.0 20.0 ND 716 716 53.1 70.3 Qualifiers LCS % Rec 103 RPD RPD 0 3 3 2 ND 17.2J 12 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 90-110 Max RPD Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 6 6 6 Qualifiers 6 6 6 D7 Page 12 of 18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WETA/5791 QC Batch Method: EPA300.0 Associated Lab Samples: 6031376001 METHOD BLANK: 253624 Associated Lab Samples: 6031376001 Parameter Chloride Fluoride Sulfate LABORATORY CONTROL SAMPLE: Chloride Fluoride Sulfate Parameter Units mgil mgil mgil 253625 mgil mgil mgil Units MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 253626 6031374018 QUALITY CONTROL DATA Analysis Method: EPA300.0 300.0 IC Anions Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 1.0 ND 0.20 ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.8 96 5 5.0 100 5 5.2 104 253627 MS MSD Spike Spike MS MSD %Rec Limits 90-110 90-110 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Chloride Fluoride Sulfate SAMPLE DUPLICATE: 253628 Chloride Fluoride Sulfate Parameter Date: 11/20/2007 05:10PM mg/L mg/L mg/L mgil mgil mgil Units 184 ND 54.0 50 50 50 6031376001 Result 3.5 0.25 9.0 50 50 50 200 201 51.5 51.7 93.0 92.1 Dup Result RPD 3.6 0.26 8.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 33 35 57-123 6 MO 101 101 80-120 0 10 78 76 60-133 12 Max RPD Qualifiers 2 14 7 13 2 11 Page13of18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/9991 QC Batch Method: SM 2540C Associated Lab Samples: 6031376001 METHOD BLANK: 254221 Associated Lab Samples: 6031376001 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 254222 Parameter Units Total Dissolved Solids mgil Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: SM 2540C Analysis

Description:

2540C Total Dissolved Solids Blank Reporting Result Limit Qualifiers ND 5.0 6031376001 Dup Result Result RPD 584 577 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page14of18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: WET/10001 QC Batch Method: SM 2540D Associated Lab Samples: 6031376001 METHOD BLANK: 254484 Associated Lab Samples: 6031376001 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 254485 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 254486 Parameter Units Total Suspended Solids mgil Date: 11/20/2007 05:10PM QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis

Description:

2540D Total Suspended Solids Blank Result ND 6031261016 Result ND 6031337002 Result 33.0 Reporting Limit Dup Result Dup Result 5.0 ND 33.0 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page15of18

Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 QC Batch: MPRP/5155 QUALITY CONTROL DATA Analysis Method: EPA6010 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QC Batch Method: EPA 3010 Analysis

Description:

6010 MET Dissolved Associated Lab Samples: 6031376001 METHOD BLANK: 255416 Associated Lab Samples: 6031376001 Parameter Units Iron ug/L LABORATORY CONTROL SAMPLE: 255417 Parameter Units Iron ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 255418 Blank Result Spike Cone. 10000 MS ND Reporting Limit 50.0 LCS Result 9940 255419 MSD Qualifiers LCS % Rec 99 6031330002 Spike Spike MS MSD Parameter Units Iron ug/L Date: 11/20/2007 05:10PM Result Cone. Cone. Result Result ND 10000 10000 9800 9490 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits Qualifiers 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 98 95 75-125 3 20 Page 16 of 18

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. QUALIFIERS Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 DEFINITIONS DF Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL Adjusted Method Detection Limit. S Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) DUP Sample Duplicate RPD Relative Percent Difference Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. ANALYTE QUALIFIERS D7 The sample and/or duplicate results for this parameter are less than the reporting limit, calculations are based on estimated values and may be statistically unreliable. H6 Analysis initiated more than 15 minutes after sample collection. MO Matrix spike recovery was outside laboratory control limits. Date: 11/20/2007 05:10PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Lenexa, KS 66219 (913)599-5665 Page 17 of 18

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: AMEREN 46691-CALLAWAY Pace Project No.: 6031376 LabiD SampleiD 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END 6031376001 TW-01 END Date: 11/20/2007 05:10PM QC Batch Method QC Batch EPA300.0 WETA/5780 EPA 180.1 WET/9945 SM 4500-H+8 WET/9946 SM 52108 WET/9947 SM 5310C WETA/5781 EPA3010 MPRP/5114 EPA 120.1 WET/9953 SM 23208 WET/9962 EPA300.0 WETA/5791 SM 2540C WET/9991 SM 25400 WET/10001 EPA3010 MPRP/5155 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analytical Analytical Method Batch SM 52108 WET/9950 EPA6010 ICP/4530 EPA6010 ICP/4556 Page 18 of 18

1.. 1 021?06 RlrmWCD-KC1 Burns & McDonnell Engineering 9400 Ward Par1tway Request for Chemical Analysis and Chain of Custody Record c;o-3i5~ Document Control No: ANti'-Y17 cAL Lab. Reference No. or Episode No.: Kansas City, Missouri 64114 Laboratory: ?Ac..E" Address: 9 tao.e Lo~re.+ 'Blvd. I ,f .. 7. J f I I I I Phone: (816) 333-9400 Fax: (816) 822-3494 Attention: An;y..\\a.. '\\Sro~'l"\\ I i'"'ft'l I I / .,.. C' I I /rJ/ /-:#~/ I / /-~/ /-bt /II/

  • f!'!/ c:l

'_:a-' --()1 I I 4G,to11 _ t;.~~-~~ Sample Type _"' {/'b/* /J...!J ~/ / / A't"lel"e.Jr\\ I Matrix i-~ -.;--J/1/ /VJj/.Jy j / S I D S E-

  • ..VI '"""I,VJ; ~.

I Sample Number Sample Event a~p e epth ample "'§i ,_ i......_, 1'--, -:!;' , f11/ (In feet) Collected

;g u

zo; / q-, -21 '/ l;/ u/ *5,'; Groupor Sample S~mple ~---_ 1.§- 0 ~ , /CJ'/ tU/lJ/ '/ IOJ~~, SWMU N-o .__Polo!_ o.,,,_, y~, _'<fl'" To,;.z:.; ::: j;( m (J: / )( l ;( :r ~1'J Rom- ~ 1 City/State/Zip: Lene.)l.~.S- _ _ (Jo26 Telephone: Cjj3j5'fl-5~ Project Number: Client Name: --(w -D\\ ~nd f------- t <lw;J) ~~~~~~i vfL<'5~j,...,J.s,<l~'b*v~M,.. 1----- I I I I 1 1 1-- 1-- i ~- ~I T J 1 I 1 !+i '*E I L...,_, r-,----r I I I , ________.... - ---------'--------+ I I I --*** ----~----i--+--+-- --~-f-. ____ J.. _ ___j _ _,__.L____j_ ! Special Instructions: SaP/#i/71 Sampler (sign*i-;: ~ i\\1,-{"flRriiiCt" jt"Um~~~~~-J~/1Jl(O_t:!!~~ __ __I Temperatu~~~~--~~ceipt: ~e~y

gnatur~

T Date/Time Relinqu.i;;lhed J3Y (oo'gnat~ p>_ Daterrime

2.

Vt'/K, /.j;>"(..._...-~ ,-~ ... ----~----------------

  • pa.~

Sample Condition Upon Receipt Courier: 0 Fed Ex 0 UPS D USPS i!el Client 0 Commercial D Pace other Tr<~cking #; -------- Project=#..:;:=:;:bl?:::/

?:::1::::~::}-&::::=::::;

Optional Proj. Due Date: I I / ( t:l Proj. Nama; 1 l Custody Seal on Cooler/Box Present:,Mes 0 no Seals intact: ~es D no Packing Material:.EfBubbloWrap. OBubbloBags D None D Othec' Thermometer Used Type of Ice~ Blue None 0 Samples on Ice, cooling process has begun Cooler Temperature

?,..
  • z._ '(..

Biologic:al Tissue is Froze~ I Date and Initials of person examining Temp should be above freezing to e*c Comments: contents: )' !f/~7! Chain of Custody Present: f!:Pfes ONo ON/A 1.

  • Chain of Custody Filled Out t!I'Yes DNo DNtA *z.

Chain of Custody R.ollnquishad: \\ZI)(es ONo DNIA 3. Sampler Name & Signature on COC: -BYes ONo ON/A 4. Samples Arrived within Hold Time: .fJYes ONo ON/A 5. Short Hold Time Analysis ( <72hr): ,reyes DNo CJWA 6. f2oD _(' fl ~~]., 'Ru~h Turn Around Time Requeste~: DYe~ BNo []N/A.7. Sufficient Volume: paryes ONo ONIA.. 8. ?o. '!rf.*(P-. NO Corr9Ct Containers Used: ip'r'os ONo ON/A 9. -Pace Containers Used: E!:"!Yes ONo ON/A. Containers Intact: EPYes ONo OWA 10. Filtered volume received for Ois!lolvect tests 0Yes DNo ~/A 11. Sample Labels match COC: [~A" UNo DNIA 12. -Includes date/time/10/Analysis Ma,triJE: - (...L_~ _ All. contaiMt~ needing prGSOMltion have been checked, ..E:!Yes ONo 'f!'NIA 13. All containars needing preservation are found to be in ~!ties DNa 6ti<JIA compliance with EPA recommendation. 'initial Mien J~ot # of added exc~ptions: VOA, coliform, TOC, Q&G, WI-PRO (water) ~eo DNo completed ~ preservative Samples checked for dechlorination: DYes ONo f';INIA 14. Headspace ln VOAV!als ( >6mml: DYes DNo iZ)NIA 15. Trip Blank Present: DYes ONo @N/A,'16. lTrip Blank Custody Seals Present DYes ONo ,15}HIA Pace Trip Blank Lot.# (if purchased)* .hotd:: ProJe&t M:anager Revlewl Date-: -------- NQ~e; Whenever there is a discrepancy affecting North Carolina COITI!Jiiance samptes, a copy of lhi$ form will pe sent to the North Carolina DEHNR Certification Office ( te out o~ hold, incorrect preservative, out of temp, Incorrect eontalnei'S) F-ALLC003rev.3, 11September2006

ace Analytical New Orleans Laboratory November 16, 2007 Client Services Pace Kansas 9608 Loiret Boulevard Lenexa, KS 66219 RE: Project: 2076003 RE: Project 10: 6031376

Dear Client Services:

Enclosed are the analytical results for sample(s) received by the laboratory on November 12,2007. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Karen Brown REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, execpt in full, without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006

ace Ana/yfical New Or/eafls Laboratory Client: P ASI Kansas Project ID: 60313 76 Client Sample ID TW-01 END Sample Cross Reference Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Lab ID Matrix 60313760 WEtter Project: 2076003 Collection Date/Time II!! 1/07 07:15 Received Date/Time I 1/12/07 09:55 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/16/21)1)71 0:40:24 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076003 Sample Receipt Condition. 1\\ll sru11ples were received in accordru1ce with EPA protocol Holding Times: 1\\ll holding times were met. Blru1ks: 1\\ll blru1k reslllts were below repmting limits. Laboratory Control Srunples: i\\11 LCS recoveries were within QC limits. Matrix Spikes ru1d Dllplicates: All MS/MSD recoveries or dt1pli.cate RPDs were "1thin QC limits. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 j 1/16:200? 10:40:54

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076003 Analytical Method Batch Sample used for QC SM 4500-SiC 94226 Project srunple TW-01 END For the sru11ple llsed as the original for the DOP or MS/MSD for ihe batch: Project srunple means a srunple from this project was llsed Client srunple meru1s a sample from the srune client bt1t in a different project was med. Batch srunple meru1s a sample from the a different client was 11sed Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/16/21)1)71 0:40:57

Sample Results Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory Client ID: TW-01 END Project ID: 60313 76 Lab ID: 6031376001

== Description:== None Analyte Method Batch DF Qu Result Silica SM 4500-Si 94226 5 1 JHI.nuneter(iS) reported 't\\""D denote~ 1\\ot Dctcdo:l at OJ above thcad~tu~to:l rcport:n,g ::.rn:t OJ PQL 1v1Dl. Ucnotc~ method. detect :on.:m:t l:m:t~ arc corrected for ~amp.c ~:zc, d:.ut:on and n10::<:turc content :f app.:cab.c Qu.:~t~ qua.:f.cr~. Spcc:f.c qua.:f.cr~ arc dcf.ncd at the end of the report Dl 30.7 Fm n.lo:o<:turc rcsu.t~, wet denote~ rcsu.t :~not corrected for mo:~turc a:ndn/~'\\ denote~ not app.:cab.c Rcgu.atory.:m:t may denote anactua. rcgu.atory.:m.t OJ ac.:cnt-rcquc~tcd not:f.cat:on.:m:t Client: PASI Kansas Project: 2076003 Site: None Matrix: Water Collected: 1l/11/07 %Moisture: Recciyed: nia Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/12/07 {;nits Reporting Limit Prep. Reg. Analysis Limit 1ng/L 5.00 15-Nov-07 15-Nov-07 13:22 TAE 11/16/21)1)71 0:40:51) LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47270

Inorganics Quality Control Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory LCS LCS LCS MS Sample Project: 2076003 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 MS MSD MS MSD MSD DL"P QC Limits Max Qu Parameter Batch Blank ARL L"nits Spike Found %Rcc Spike Found Found Found %Rcc %Rcc RPD RPD LCS MS/MSD RPD Silic8 94226 :sro 1.00 n1g/L 10 10.76 108 10 30.71 38.68 11 denote iS ncm*er:y oubide of QC limib. l\\""0 denotesl"iotDeteded at or abqvethe adju:ded :reporting1imit or PQL. 1\\JSll\\JSD RPD i:s calculated "lia S\\Y-846 ru]e:s on the b~iiS of iSJlil.red ~Sample concentrntion:s rather than iSJlil'e recoYerleiS. 80 2 90 11075 125 20 Dl ll/16/21)1)71 0:41 :I) I LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-1)421)2 ES. Dept f?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47271)

ace Ana/yfical New Or/eafls Laboratory Qualifier Qualifier Description Qualifier Summary Project: 2076003 Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 Dl The imalysis "'VI.' as perfonned at 8 dilution due to the high ru1Etlyte concenu*ation. ll/16/21)1)71 0:41 :1)4 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

November 26, 2007 PAT HIGGINS BURNS & MCDONNELL 9400 WARD PARKWAY Kansas City, MO 64114 RE : Project: CALLAWAY 46691 Pace Project No.. 6031558

Dear PAT HIGGINS:

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Enclosed are the analytical results for sample(s) received by the laboratory on November 15, 2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, . ll.,,.../...--, l..JrWifJ,_.()..I /}1---- Angie Brown Angie.Brown@pacelabs.com Project Manager A2LA Certification Number: 2456.01 Arkansas Certification Number: 05-008-0 Illinois Certification Number: 001191 Iowa Certificalion Number: 118 Kansas/NELAP Certificalion Number: E-1 0116 Louisiana Certificalion Number: 03055 Oklahoma Certification Number: 9205/9935 Utah Certificalion Number: 9135995665 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Page 1 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 LabiD Sample ID 6031558001 TW-02 SAMPLE

SUMMARY

Matrix Date Collected Date Received Water 11/14/07 10:30 11/15/07 14:25 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Page 2 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 LabiD Sample ID 6031558001 TW-02 SAMPLE ANALYTE COUNT EPA 120.1 EPA 180.1 EPA 300.0 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM 52108 SM 5310C Method REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Analytes Reported 4 8 3 Lenexa, KS 66219 (913)599-5665 Page 3 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 Sample: TW-02 Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (CaC03) Alkalinity, Carbonate (CaCO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 5310C TOC Total Organic Carbon Date: 11/26/2007 05:07PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Lab ID: 6031558001 Collected: 11/14/07 10:30 Received: 11/15/07 14:25 Matrix: Water Results Units Report Limit DF Prepared Analytical Method: EPA 6010 Preparation Method: EPA 3010 831 ug/L 10.0 11/16/07 00:00 101000 ug/L 100 11/16/07 00:00 3850 ug/L 50.0 11/16/07 00:00 25500 ug/L 50.0 11/16/07 00:00 244 ug/L 5.0 11/16/07 00:00 3410 ug/L 500 11/16/07 00:00 15300 ug/L 500 11/16/07 00:00 557 ug/L 10.0 11/16/07 00:00 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/20/07 00:00 Analytical Method: EPA 120.1 685 umhos/cm 1.0 Analytical Method: EPA 180.1 37.6 NTU 5.0 Analytical Method: SM 2320B 342 mg/L 20.0 ND mg/L 20.0 342 mg/L 20.0 Analytical Method: SM 2540C 453 mg/L 5.0 Analytical Method: SM 2540D 13.0 mg/L 5.0 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/15/07 17:23 Analytical Method: EPA 300.0 ND mg/L 1.0 Analytical Method: EPA 300.0 7.7 mg/L 1.0 0.31 mg/L 0.20 32.7 mg/L 1.0 Analytical Method: SM 5310C 1.7 mg/L 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analyzed CAS No. Qual 11/19/07 10:07 7440-39-3 11/19/07 10:07 7440-70-2 11/19/07 10:07 7439-89-6 11/19/0713:13 7439-95-4 11/19/07 10:07 7439-96-5 11/19/07 10:07 7440-09-7 11/19/07 10:07 7440-23-5 11/19/07 10:07 7440-24-6 11/26/07 14:38 7439-89-6 11/19/07 00:00 11/16/07 09:30 11/17/07 14:00 11/17/07 14:00 11/17/07 14:00 11/19/07 15:05 11/19/07 11:46 11/20/07 13:33 11/16/07 03:57 14797-55-8 11/19/07 23:50 16887-00-6 11/19/07 23:50 16984-48-8 11/19/07 23:50 14808-79-8 11/20/07 00:00 7440-44-0 Page4of17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WETA/5797 QC Batch Method: EPA300.0 Associated Lab Samples: 6031558001 METHOD BLANK: 254230 Associated Lab Samples: 6031558001 Parameter Units Nitrate as N mgil LABORATORY CONTROL SAMPLE: 254231 Parameter Units Nitrate as N mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 254232 6031510003 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

Blank Result Reporting Limit EPA300.0 300.0 IC Anions Qualifiers ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.8 96 254233 MS MSD Spike Spike MS MSD %Rec Limits 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L SAMPLE DUPLICATE* 254234 Parameter Units Nitrate as N mgil Date: 11/26/2007 05:07PM 4.1 5 6031512001 Result 3.6 5 Dup Result 8.6 3.6 8.6 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 90 Max RPD 89 11 61-128 0 7 Qualifiers Page 5 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10006 QC Batch Method: SM 5210B Associated Lab Samples: 6031558001 METHOD BLANK: 254675 Associated Lab Samples: 6031558001 Parameter Units BOD, 5 day mgil LABORATORY CONTROL SAMPLE: 254676 Parameter Units BOD, 5 day mgil SAMPLE DUPLICATE: 254677 Parameter Units BOD, 5 day mgil Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: SM 5210B Analysis

Description:

5210B BOD, 5 day Blank Result Spike Cone. 198 ND 6031548003 Result 4.2 Reporting Limit LCS Result 213 Dup Result 2.0 5.0 Qualifiers LCS % Rec 108 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 17 %Rec Limits 85-115 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 17 Page 6 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10009 QC Batch Method: EPA 180.1 Associated Lab Samples: 6031558001 METHOD BLANK: 254846 Associated Lab Samples: 6031558001 Parameter Units Turbidity NTU LABORATORY CONTROL SAMPLE: 254847 Parameter Units Turbidity NTU SAMPLE DUPLICATE: 254848 Parameter Units Turbidity NTU Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

EPA 180.1 180.1 Turbidity Blank Result Reporting Limit Qualifiers Spike Cone. 10 ND 6031558001 Result 37.6 LCS Result 10.3 Dup Result 1.0 37.6 LCS % Rec 103 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~;.c 0 %Rec Limits 80-120 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 10 Page 7 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: MPRP/5144 QC Batch Method: EPA 3010 Associated Lab Samples: 6031558001 METHOD BLANK: 254866 Associated Lab Samples: 6031558001 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L LABORATORY CONTROL SAMPLE: 254867 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 254868 6031561001 Parameter Units Result Barium ug/L 0.062 mg!L Calcium ug/L 31.1 mg!L Iron ug/L 2.1 mg!L Magnesium ug/L 10.2 mg!L Manganese ug/L 0.019 mg!L Potassium ug/L 9.1 mg!L Sodium ug/L 67.9 mg!L Strontium ug/L 0.21 mg!L QUALITY CONTROL DATA Analysis Method: EPA6010 6010 MET Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 10.0 ND 100 ND 50.0 ND 50.0 ND 5.0 ND 500 ND 500 ND 10.0 Spike LCS LCS Cone. Result % Rec 1000 978 98 10000 10000 100 10000 9960 100 10000 10200 102 1000 1020 102 10000 9470 95 10000 9640 96 1000 970 97 254869 MS MSD Spike Spike MS MSD Cone. Cone. Result Result 1000 1000 979 1020 10000 10000 40600 42000 10000 10000 10600 11100 10000 10000 19400 20400 1000 1000 984 1030 10000 10000 18400 19300 10000 10000 76100 78900 1000 1000 1160 1200 Date: 11/26/2007 05:07PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Limits Qualifiers 80-120 80-120 80-120 80-120 80-120 80-120 80-120 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 92 96 75-125 4 7 96 109 75-125 3 8 85 90 75-125 4 12 93 103 75-125 5 7 96 101 75-125 4 9 93 101 75-125 4 7 81 110 75-125 4 12 95 99 75-125 4 11 Page 8 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10021 QC Batch Method: SM 2320B Associated Lab Samples: 6031558001 METHOD BLANK: 255085 Associated Lab Samples: 6031558001 Parameter Units Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) LABORATORY CONTROL SAMPLE: Parameter Alkalinity, Tolal SAMPLE DUPLICATE: 255087 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) SAMPLE DUPLICATE: 256169 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) Date: 11/26/2007 05:07PM mgil mgil mgil 255086 Units mgil Units mgil mgil mgil Units mgil mgil mgil QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 2320B 2320B Alkalinity Blank Reporting Result Spike Cone. 500 ND ND ND 6031261007 Result ND 291 291 6031558001 Result ND 342 342 Limit LCS Result 464 Dup Result Dup Result 20.0 20.0 20.0 ND 291 291 ND 348 348 Qualifiers LCS % Rec 93 RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 0 0 2 2 %Rec Limits 90-110 Max RPD Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 6 6 6 Qualifiers 6 6 6 Page 9 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10038 QC Batch Method: SM 2540D Associated Lab Samples: 6031558001 METHOD BLANK: 256020 Associated Lab Samples: 6031558001 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256021 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256022 Parameter Units Total Suspended Solids mgil Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis

Description:

2540D Total Suspended Solids Blank Result ND 6031530001 Result 116 6031487003 Result 400 Reporting Limit Dup Result Dup Result 5.0 106 400 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 9 0 Max RPD Max RPD 5 R1 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 10 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WETA/5816 QC Batch Method: EPA300.0 Associated Lab Samples: 6031558001 METHOD BLANK: 256056 Associated Lab Samples: 6031558001 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil LABORATORY CONTROL SAMPLE: 256057 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 256059 6031260006 QUALITY CONTROL DATA Analysis Method: EPA300.0 300.0 IC Anions Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 1.0 ND 0.20 ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.6 91 5 5.1 101 5 4.9 98 256060 MS MSD Spike Spike MS MSD %Rec Limits 90-110 90-110 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Chloride Fluoride Sulfate SAMPLE DUPLICATE: 256058 Chloride Fluoride Sulfate Parameter Date: 11/26/2007 05:07PM mg/L mg/L mg/L mgil mgil mgil Units 140 250 250 387 389 ND 250 250 281 283 1730 250 250 1950 1980 6031261001 Dup Result Result RPD 112 110 0.67 0.65 52.6 52.7 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 99 100 57-123 6 112 113 80-120 10 91 100 60-133 12 Max RPD Qualifiers 1 14 2 13 0 11 Page 11 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10042 QC Batch Method: SM 2540C Associated Lab Samples: 6031558001 METHOD BLANK: 256070 Associated Lab Samples: 6031558001 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 256191 Parameter Units Total Dissolved Solids mgil Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: SM 2540C Analysis

Description:

2540C Total Dissolved Solids Blank Reporting Result Limit Qualifiers ND 5.0 6031558001 Dup Result Result RPD 453 457 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 12 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WET/10046 QC Batch Method: EPA 120.1 Associated Lab Samples: 6031558001 METHOD BLANK: 256157 Associated Lab Samples: 6031558001 Parameter Units Specific Conductance umhos/cm SAMPLE DUPLICATE: 256159 Parameter Units Specific Conductance umhos/cm Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: EPA 120.1 Analysis

Description:

120.1 Specific Conductance Blank Reporting Result Limit Qualifiers ND 1.0 6031634001 Dup Result Result RPD 616 617 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 0 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 13 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: WETA/5824 QC Batch Method: SM 5310C Associated Lab Samples: 6031558001 METHOD BLANK: 256545 Associated Lab Samples: 6031558001 Parameter Units Total Organic Carbon mgil LABORATORY CONTROL SAMPLE: 256546 Parameter Units Total Organic Carbon mgil MATRIX SPIKE SAMPLE: 256548 Parameter Units Total Organic Carbon mgil SAMPLE DUPLICATE: 256547 Parameter Units Total Organic Carbon mgil Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: SM 5310C Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

5310C Total Organic Carbon Blank Result Spike Cone. 5 ND 6031651001 Result Reporting Limit LCS Result 6.2 Spike Cone. 1.0 15.2 25 6031634001 Result 1.9 Dup Result 1.8 Qualifiers LCS % Rec 125 MS Result 55.8 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 7 %Rec Limits 79-126 MS %Rec 162 Max RPD Qualifiers % Rec Limits 42-141 M1 Qualifiers 21 Qualifiers Page 14 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 QC Batch: MPRP/5175 QC Batch Method: EPA 3010 Associated Lab Samples: 6031558001 METHOD BLANK: 256791 Associated Lab Samples: 6031558001 Parameter Units Iron ug/L LABORATORY CONTROL SAMPLE: 256792 Parameter Units Iron ug/L MATRIX SPIKE SAMPLE: 256793 Parameter Units Iron ug/L Date: 11/26/2007 05:07PM QUALITY CONTROL DATA Analysis Method: EPA6010 Analysis

Description:

6010 MET Dissolved Blank Result Spike Cone. 10000 ND 6031610003 Result Reporting Limit LCS Result 10400 Spike Cone. 50.0 10000 Qualifiers LCS % Rec 104 MS Result 10100 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 80-120 MS %Rec 100 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers % Rec Limits 75-125 Lenexa, KS 66219 (913)599-5665 Qualifiers Page 15 of 17

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. QUALIFIERS Project: CALLAWAY 46691 Pace Project No.: 6031558 DEFINITIONS DF Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL Adjusted Method Detection Limit. S Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) DUP Sample Duplicate RPD Relative Percent Difference Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. R 1 RPD value was outside control limits. Date: 11/26/2007 05:07PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Lenexa, KS 66219 (913)599-5665 Page 16 of 17

Project: CALLAWAY 46691 Pace Project No.: 6031558 LabiD SampleiD 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 6031558001 TW-02 Date: 11/26/2007 05:07PM Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QUALITY CONTROL DATA CROSS REFERENCE TABLE QC Batch Method QC Batch EPA300.0 WETA/5797 SM 52108 WET/10006 EPA 180.1 WET/10009 EPA3010 MPRP/5144 SM 23208 WET/10021 SM 25400 WET/10038 EPA300.0 WETA/5816 SM 2540C WET/10042 EPA 120.1 WET/10046 SM 5310C WETA/5824 EPA3010 MPRP/5175 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analytical Analytical Method Batch SM 52108 WET/10008 EPA6010 ICP/4551 EPA6010 ICP/4576 Page 17 of 17

021700 FarmWCO-KC1 Burns & McDonnell Engineering 9400 Ward Parkway Request for Chemical Analysis and Chain of Custody Record Laboratory: ~e.G" A.N AL 'I 'T I c.A; L-Document Control No: Lab. Reference No. or Episode No.: r/102./~6 / Kansas City, Missouri 64114 Phone: (816) 333-9400 Fax: (816) 822-3494 Address: 9~oS Lo;r~.J. "'Sivd. City/State/Zip: Le-'f'l.e.Y..'S., /(S, loCoz..t '1 / II I -1::_ lj;l I I / 111./ I i I-~* /,/ ~-/ I I Attention: I ~ "'t"t{ / i ~~ / ~-/, n/ / "'I "if: I

"*I 1'fl

/ I ~~ / I ~;..... '/ I I ~/ )j'/ "f'v* '"):)I / / ~~ ~I ~~ t' ij _____________ __j_---.------!"5 e ..f! {!}i I /:. 1 ~/ / I Matrix iii.~ /./ / )/ 4'/ I I s~~-p~~-D-;p_t_h---,--S-a-mpl-e--l--,-----;-----,i~- ~ ~ /~I -:;J!f/;1~ til I {lj 1 (in feet) Collected ~ :.., zo i j --:1!/

y I V 'i::/

Group or Sample S~mpje l .§- ; 0 ~ I Q~ tit t!/; ~~ f<":J/VJ' SWMU Name Point Designator Year From ; To Date Time ...;, w C!l

.... o; ~/ r 1 1!;/ f'

I t I t.q 1 ,-..t ~~~~ I 'Y~

~- t.-1"1!

epi-~.. Telephone: 913/ 5{.:,.3 -1402... Project Number: --~Cj J Client Name: Uli~w~ Sample Number rrw.-:_Q_ 2, Sampte Type I r-= __ L---t-----~*--t--t-----1-----!------ ---t----~-- - i-

    • --*--**-------~----1--+--+-----------j i!---1-. ---+---+--+--'--+----+:-+----!--+-+--+--l-----------l

~----- r---~::= ~-=~~~:: :_:=- ,- -~=h 1-- --1 I I I 1 I I 1------- I I s~ (s'f!'1"1ure): I Sampler (.*!gr,atur*): Speciat Instructions: ~ ""'""¢ ft.u~ 1!1.(, ~m~;;;

    • _* R~~---;iv

__ ~_e;;~d --~------~ r*~~- 1 -J:!!: ~. i*_ Date!Ti'!'~ Ice Pres t in Contain~-, Temperature Upon Receipt:, -z_, L u)J5/o? ____ _/!{..e:'}l~ _-:=;? /;0'.9'0J ;nJf!es [::2} Not-~, _, ,r. Relirtquished By (signature): Date/Time Received By {signature}- ! Date/Time I Laboratory Comments:

2.

Sample Condition Upon Receipt p~ Client Name: &W~ * ~<<> Project~#..;;:=;::/#:::. t:J=~=r 55=-~====; Optional Courier: 0 Fed Ex D UPS D USPS fil-cuent D Commercial D Pace other Proj. Due Date: Proj. Name: tr(~ Tracking#:--------- Custody Seal on CoolerlBox Present: 0 yes ~ no Seals intact: D yes e no Pac~ing_ Material: D Bubble Wrap D Bubble Bags D None 0- Other

.t-, P"t-o;::....

~~~~-------- Thermometer Used t~'t( Type of lcEJ: ~ Blue None 0 Samples on Ice, cooling proce~s has begun Cooler Temperature 'l* l.... Biological Tissue is Frozen: Ye~ N<> Date and Initials of per$On examining contents: <BIA.::>

    • ;_,1fi.

Temp should be above freezing to 6"C Comments: Chain of Custody Present ~ss DNo ONIA 1.

  • .Chain of Custody Filled Out:

I:SYes DNo DNIA 2. Chain of custody Relinquished: ~y,.. DNo DNIA,3. Sampler Name & Signat1,.1re on COC: ~Y.-,s DNo DNIA 4. Samples Arrived within Hold Time; fii]Yeg DNa DMIA 5. Short Hold Time Analysis (<72hr): (Wv.,. DNo [:;JNIA 6. "fll~ ~ ..,+( Rush Turn Around Time Requested:. DYes t;~Go DNIA 7, SuffK:ieflt Volume: !)Yes DNo DNI.~.8. Correct Containers Used: ElY as DNo DNIA 9. -Pace Containers Used: ~Yes OtJo ON/A Containers Intact; RlYes DNo ON/.11. 10. Filtered volume I"E!ceived for Ois~olved tests DYes JilNo ON/A '11. Sample Labels match COC: i;iJYes ONo ON/A 12.

  • Includes datetllme/ID/Analyt?is Matrix:

.,.._,r-' AU contslners needing preserva:Lion have been checked. Qb'e" DNo DNIA 13. A11* oontainers needing preservation are found to be in !aYes ONo O~J/A compliance v.ith EPA recommendation. ox~eptions; VOA *. col~orm, TOC, O&G, WI..ORO (water) DYes IBNo lnitiall'otlen Lot# of added completed preservative Samples checked for dechlorination: DYes DNo CiJ-NIA 14. Headspace in VOA Vials { >6mm}: DYes Dl~u ~NIA 15. Trip Blank Present: DYes DNo IBN/A 16. Trip Blank Custody Seals Present DYes DNo lliiNIA

  • Pace Trip Blank Lot# {if purchased);

Client Notification/ Resolution: Field Data RGquirecl? Y I N Person Contacted: OatefTime: ( Comments/ Resolution:( f( !{a,-AU~O.f>1d 1 Ci[S:V61,* 0Ai1o -p. Project M*anager Review: Date: tl1, 1,/m Note: Whenever there is a discrepancy affi!ctlng North Carolina compliance samples, a copy of this form will be sent to lhe.Norlh Carolina DE:HNR Certification Office ( i.e out of. hold, incorrect preservative, out of temp, incorrect containers) F*ALLC003~v.3, 11September2006

ace Analytical New Orleans Laboratory November 21, 2007 Client Services Pace Kansas 9608 Loiret Boulevard Lenexa, KS 66219 RE: Project: 2076197 RE: Project 10: 6031558

Dear Client Services:

Enclosed are the analytical results for sample(s) received by the laboratory on November 15,2007. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Karen Brown REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, execpt in full, without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006

ace Ana/yfical New Or/eafls Laboratory Client: P ASI Kansas Project ID: 6031558 Client Sample ID Th'-02 Sample Cross Reference Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Lab ID Matrix 60315580 WEtter Project: 2076197 Collection Date/Time 11!14/07 I 0:30 Received Date/Time 11/15/07 14:25 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/2l/21)1)717:1)3:J(I LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076197 Sample Receipt Condition. 1\\1l sru11ples were received in accordru1ce with EPA protocol Holding Times: 1\\1l holding times were met. Blru1ks: 1\\1l blru1k reslllts were below repmting limits. Laboratory Control Srunples: i\\11 LCS recoveries were within QC limits. Matrix Spikes ru1d Dllplicates: MS or MSD recoveries olltside of QC limits me qllalified in the Report ofQllality Control section. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 1 1:21:200? 1?:04:())

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076197 Analytical Method Batch Sample used for QC SM 4500-SiC 94446 Client sample MW-5S fi*om project 2076200 For the sru11ple llsed as the original for the DOP or MS/MSD for ihe batch: Project srunple means a srunple from this pmject was llsed Client srunple meru1s a sample from the srune client bt1t in a different project was med. Batch srunple meru1s a sample fi*om the a different client was 11sed Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/21/21)1)717:1)4:1)1)

Sample Results Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory Client ID: TW-02 Project ID: 6031558 Lab ID: 6031558001

== Description:== None Analyte Method Batch DF Qu Result Silica SM 4500-Si 94446 5 1 JHI.nuneter(iS) reported 't\\""D denote~ 1\\ot Dctcdo:l at OJ above thcad~tu~to:l rcport:n,g ::.rn:t OJ PQL 1v1Dl. Ucnotc~ method. detect :on.:m:t l:m:t~ arc corrected for ~amp.c ~:zc, d:.ut:on and n10::<:turc content :f app.:cab.c Qu.:~t~ qua.:f.cr~. Spcc:f.c qua.:f.cr~ arc dcf.ncd at the end of the report Dl 27.9 Fm n.lo:o<:turc rcsu.t~, wet denote~ rcsu.t :~not corrected for mo:~turc a:ndn/~'\\ denote~ not app.:cab.c Rcgu.atory.:m:t may denote anactua. rcgu.atory.:m.t m ac.:cnt-rcquc~tcd not:f.cat:on.:m:t Client: PASI Kansas Project: 2076197 Site: None Matrix: Water Collected: 1l/14/07 %Moisture: Recciyed: nia Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/15/07 {;nits Reporting Limit Prep. Reg. Analysis Limit 1ng/L 5.00 20-Nov-07 20-Nov-07 17:21 TAE ll/21/21)1)717:1)4: 12 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47270

Inorganics Quality Control ace Ana/yfical New Or/eafls Laboratory Project: 2076197 LCS LCS LCS MS Sample MS MSD MS MSD MSD Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 DL"P Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 QC Limits Max Qu Parameter Batch Blank ARL L"nits Spike Found%Rcc Spike Found Found Found %Rcc %Rcc RPD RPD LCS MS/MSD RPD Silic8 94446 :sro 1.00 n1g/L 10 11.75 17.37 Silic8 94446 n1g/L 10 10.91 109 11.75 11 denote iS ncm*er:y oubide of QC limib. l\\""0 denotesl"iotDeteded at or abqvethe adju:ded :reporting1imit or PQL. 1\\JSll\\JSD RPD i:s calculated "lia S\\Y-846 ru]e:s on the b~iiS of iSJlil.red ~Sample concentrntion:s rather than iSJlil'e recoYerleiS.

56.

75 125 90 110 20 ll/21/21)1)717:1)4: 15 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-1)421)2 ES. Dept f?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47271) Ql

Qualifier Summary ace Ana/yfical New Or/eafls Laboratory Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 Qualifier Dl Ql Project: 2076197 Qualifier Description The imalysis "'VI.' as perfonned at 8 dilution due to the high ru1Etlyte concenu*ation. The matrix spike recoveries me poor. Acceptable method perfonmmce for this *malyte has been demonstrated by the laboratory control sru11ple recO'\\I*eJy. ll/21/21)1)717:1)4: 17 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

November 27, 2007 PAT HIGGINS BURNS & MCDONNELL 9400 WARD PARKWAY Kansas City, MO 64114 RE : Project: AMEREN Pace Project No.. 6031634

Dear PAT HIGGINS:

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Enclosed are the analytical results for sample(s) received by the laboratory on November 16, 2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, . ll.,,.../...--, l..JrWifJ,_.()..I /}1---- Angie Brown Angie.Brown@pacelabs.com Project Manager A2LA Certification Number: 2456.01 Arkansas Certification Number: 05-008-0 Illinois Certification Number: 001191 Iowa Certificalion Number: 118 Kansas/NELAP Certificalion Number: E-1 0116 Louisiana Certificalion Number: 03055 Oklahoma Certification Number: 9205/9935 Utah Certificalion Number: 9135995665 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Page 1 of 20

Project: AMEREN Pace Project No.: 6031634 LabiD Sample ID 6031634001 TW02-MID SAMPLE

SUMMARY

Matrix Date Collected Date Received Water 11/15/07 15:10 11/16/07 09:25 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Page 2 of 20

Project: AMEREN Pace Project No.: 6031634 LabiD Sample ID 6031634001 TW02-MID SAMPLE ANALYTE COUNT EPA 120.1 EPA 180.1 EPA 300.0 EPA365.1 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM4500-H+8 SM 52108 SM 5310C Method REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Analytes Reported 4 8 3 Lenexa, KS 66219 (913)599-5665 Page 3 of 20

Project: AMEREN Pace Project No.: 6031634 Sample: TW02-MID Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (GaG03) Alkalinity, Carbonate (GaGO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 4500H+ pH, Electrometric pH at 25 Degrees G 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 365.1 Phosphate, Ortho as P Orthophosphate as P Date: 11/27/2007 04:46PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Lab ID: 6031634001 Collected: 11/15/07 15:10 Received: 11/16/07 09:25 Matrix: Water Results Units Report Limit DF Prepared Analyzed GAS No. Analytical Method: EPA 6010 Preparation Method: EPA 3010 870 ug/L 10.0 11/19/07 00:00 11/26/07 17:03 7440-39-3 115000 ug/L 100 11/19/07 00:00 11/26/07 17:03 7440-70-2 6970 ug/L 50.0 11/19/07 00:00 11/26/07 17:03 7439-89-6 26200 ug/L 50.0 11/19/07 00:00 11/27/07 12:09 7439-95-4 272 ug/L 5.0 11/19/07 00:00 11/26/07 17:03 7439-96-5 3390 ug/L 500 11/19/07 00:00 11/26/07 17:03 7440-09-7 7140 ug/L 500 11/19/07 00:00 11/26/07 17:03 7440-23-5 587 ug/L 10.0 11/19/07 00:00 11/26/07 17:03 7440-24-6 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/20/07 00:00 11/26/07 14:51 7439-89-6 Analytical Method: EPA 120.1 616 umhos/cm 1.0 11/19/07 00:00 Analytical Method: EPA 180.1 82.6 NTU 5.0 11/16/07 16:15 Analytical Method: SM 2320B 383 mg/L 20.0 11/20/07 15:59 ND mg/L 20.0 11/20/07 15:59 383 mg/L 20.0 11/20/07 15:59 Analytical Method: SM 2540G 421 mg/L 5.0 11/20/07 15:41 Analytical Method: SM 2540D 9.0 mg/L 5.0 11/20/07 11:35 Analytical Method: SM 4500-H+B 7.2 Std. Units 0.10 11/16/07 15:00 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/16/07 17:26 11/21/07 14:45 Analytical Method: EPA 300.0 ND mg/L 1.0 Analytical Method: EPA 300.0 6.6 mg/L 1.0 0.31 mg/L 0.20 26.2 mg/L 1.0 Analytical Method: EPA 365.1 ND mg/L 0.10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 11/16/07 19:47 14797-55-8 11/20/07 00:16 16887-00-6 11/20/07 00:16 16984-48-8 11/20/07 00:16 14808-79-8 11/16/07 14:13 Qual H6 Page4of20

Project: AMEREN Pace Project No.: 6031634 Sample: TW02-MID Parameters 5310C TOC Total Organic Carbon Date: 11/27/2007 04:46PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 LabiD: 6031634001 Collected: 11/15/0715:10 Received: 11/16/07 09:25 Matrix: Water Results Units Report Limit OF Prepared Analytical Method: SM 5310G 1.9 mg/L 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analyzed GAS No. Qual 11/20/07 00:00 7440-44-0 Page 5 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WETA/5808 QC Batch Method: EPA300.0 Associated Lab Samples: 6031634001 METHOD BLANK: 254964 Associated Lab Samples: 6031634001 Parameter Units Nitrate as N mgil LABORATORY CONTROL SAMPLE: 254965 Parameter Units Nitrate as N mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 254966 6031600002 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

Blank Result Reporting Limit EPA300.0 300.0 IC Anions Qualifiers ND 1.0 Spike Cone. MS Spike 5 LCS Result 4.9 254967 MSD Spike MS LCS % Rec MSD 98 %Rec Limits 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L SAMPLE DUPLICATE* 254968 Parameter Units Nitrate as N mgil Date: 11/27/2007 04:46PM 23.5 25 6031604002 Result 3.5 25 44.1 Dup Result 3.5 43.9 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 83 0 Max RPD 82 11 61-128 7 Qualifiers Page 6 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WETA/5813 QC Batch Method: EPA 365.1 Associated Lab Samples: 6031634001 METHOD BLANK: 255059 Associated Lab Samples: 6031634001 Parameter Units Orthophosphate as P mgil LABORATORY CONTROL SAMPLE: 255060 Parameter Units Orthophosphate as P mgil MATRIX SPIKE SAMPLE: 255061 Parameter Units Orthophosphate as P mgil SAMPLE DUPLICATE: 255062 Parameter Units Orthophosphate as P mgil Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: EPA365.1 Analysis

Description:

365.1 Phosphorus, Ortho Blank Result Spike Cone. 2 ND 6031613005 Result Reporting Limit LCS Result 1.9 Spike Cone. 0.10 ND 2 6031613001 Result ND Dup Result ND Qualifiers LCS % Rec 93 MS Result RPD 1.9 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 %Rec Limits 90-110 MS %Rec Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers 96 20 % Rec Limits 90-110 Qualifiers Qualifiers Page 7 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10025 QC Batch Method: SM 4500-H+B Associated Lab Samples: 6031634001 SAMPLE DUPLICATE: 255176 Parameter Units pH at 25 Degrees C Std. Units Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

6031615001 Result 8.2 Dup Result SM 4500-H+B 4500H+B pH RPD 8.2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD 5 H6 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 8 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10030 QC Batch Method: EPA 180.1 Associated Lab Samples: 6031634001 METHOD BLANK: 255380 Associated Lab Samples: 6031634001 Parameter Units Turbidity NTU LABORATORY CONTROL SAMPLE: 255381 Parameter Units Turbidity NTU SAMPLE DUPLICATE: 255382 Parameter Units Turbidity NTU Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

EPA 180.1 180.1 Turbidity Blank Result Reporting Limit Qualifiers Spike Cone. 10 ND 6031634001 Result 82.6 LCS Result 10 Dup Result 1.0 83.4 LCS % Rec 100 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 80-120 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 10 Page 9 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10031 QC Batch Method: SM 5210B Associated Lab Samples: 6031634001 METHOD BLANK: 255384 Associated Lab Samples: 6031634001 Parameter Units BOD, 5 day mgil LABORATORY CONTROL SAMPLE: 255385 Parameter Units BOD, 5 day mgil SAMPLE DUPLICATE: 255386 Parameter Units BOD, 5 day mgil Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: SM 5210B Analysis

Description:

5210B BOD, 5 day Blank Result Spike Cone. 198 ND 6031632001 Result 1180 Reporting Limit LCS Result 191 Dup Result 2.0 1240 Qualifiers LCS % Rec 97 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 5 %Rec Limits 85-115 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 17 Page 10 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10035 QC Batch Method: SM 2320B Associated Lab Samples: 6031634001 METHOD BLANK: 255959 Associated Lab Samples: 6031634001 Parameter Units Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) LABORATORY CONTROL SAMPLE: Parameter Alkalinity, Tolal SAMPLE DUPLICATE: 255962 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) SAMPLE DUPLICATE: 256855 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) Date: 11/27/2007 04:46PM mgil mgil mgil 255960 Units mgil Units mgil mgil mgil Units mgil mgil mgil QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 2320B 2320B Alkalinity Blank Reporting Result Spike Cone. 500 ND ND ND 6031630004 Result ND 468 456 6031634001 Result ND 383 383 Limit LCS Result 503 Dup Result 20.0 20.0 20.0 12.9J 476 464 Dup Result ND 387 387 Qualifiers LCS % Rec 101 RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 2 2 2 0 %Rec Limits 90-110 Max RPD Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 6 6 6 Qualifiers 6 6 6 Page 11 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WETA/5816 QC Batch Method: EPA300.0 Associated Lab Samples: 6031634001 METHOD BLANK: 256056 Associated Lab Samples: 6031634001 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil LABORATORY CONTROL SAMPLE: 256057 Parameter Units Chloride mgil Fluoride mgil Sulfate mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 256059 6031260006 QUALITY CONTROL DATA Analysis Method: EPA300.0 300.0 IC Anions Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 1.0 ND 0.20 ND 1.0 Spike LCS LCS Cone. Result % Rec 5 4.6 91 5 5.1 101 5 4.9 98 256060 MS MSD Spike Spike MS MSD %Rec Limits 90-110 90-110 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Chloride Fluoride Sulfate SAMPLE DUPLICATE: 256058 Chloride Fluoride Sulfate Parameter Date: 11/27/2007 04:46PM mg/L mg/L mg/L mgil mgil mgil Units 140 250 250 387 389 ND 250 250 281 283 1730 250 250 1950 1980 6031261001 Dup Result Result RPD 112 110 0.67 0.65 52.6 52.7 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 99 100 57-123 6 112 113 80-120 10 91 100 60-133 12 Max RPD Qualifiers 1 14 2 13 0 11 Page 12 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: MPRP/5159 QC Batch Method: EPA 3010 Associated Lab Samples: 6031634001 METHOD BLANK: 256083 Associated Lab Samples: 6031634001 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L LABORATORY CONTROL SAMPLE: 256084 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 256085 6031612002 Parameter Units Result Barium ug/L 271 Calcium ug/L 128000 Iron ug/L 21000 Magnesium ug/L 10200 Manganese ug/L 1150 Potassium ug/L 3400 Sodium ug/L 27800 Strontium ug/L 233 QUALITY CONTROL DATA Analysis Method: EPA6010 6010 MET Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 10.0 ND 100 ND 50.0 ND 50.0 ND 5.0 ND 500 ND 500 ND 10.0 Spike LCS LCS Cone. Result % Rec 1000 1040 104 10000 10900 109 10000 10500 105 10000 10700 107 1000 1060 106 10000 10300 103 10000 10200 102 1000 1030 103 256086 MS MSD Spike Spike MS MSD Cone. Cone. Result Result 1000 1000 1210 1230 10000 10000 133000 136000 10000 10000 29700 30200 10000 10000 20100 20100 1000 1000 2080 2110 10000 10000 13400 13500 10000 10000 36400 36700 1000 1000 1200 1210 Date: 11/27/2007 04:46PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Limits Qualifiers 80-120 80-120 80-120 80-120 80-120 80-120 80-120 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 94 96 75-125 7 47 75 75-125 2 8 MO 87 91 75-125 2 12 99 100 75-125 0 7 93 95 75-125 9 100 101 75-125 7 87 89 75-125 12 96 98 75-125 11 Page 13 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10046 QC Batch Method: EPA 120.1 Associated Lab Samples: 6031634001 METHOD BLANK: 256157 Associated Lab Samples: 6031634001 Parameter Units Specific Conductance umhos/cm SAMPLE DUPLICATE: 256159 Parameter Units Specific Conductance umhos/cm Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: EPA 120.1 Analysis

Description:

120.1 Specific Conductance Blank Reporting Result Limit Qualifiers ND 1.0 6031634001 Dup Result Result RPD 616 617 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 0 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 14 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10053 QC Batch Method: SM 2540D Associated Lab Samples: 6031634001 METHOD BLANK: 256334 Associated Lab Samples: 6031634001 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256335 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256336 Parameter Units Total Suspended Solids mgil Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis

Description:

2540D Total Suspended Solids Blank Result ND 6031612002 Result 40.0 6031619001 Result 50.0 Reporting Limit Dup Result Dup Result 5.0 40.0 50.0 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 15 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WETA/5824 QC Batch Method: SM 5310C Associated Lab Samples: 6031634001 METHOD BLANK: 256545 Associated Lab Samples: 6031634001 Parameter Units Total Organic Carbon mgil LABORATORY CONTROL SAMPLE: 256546 Parameter Units Total Organic Carbon mgil MATRIX SPIKE SAMPLE: 256548 Parameter Units Total Organic Carbon mgil SAMPLE DUPLICATE: 256547 Parameter Units Total Organic Carbon mgil Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: SM 5310C Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

5310C Total Organic Carbon Blank Result Spike Cone. 5 ND 6031651001 Result Reporting Limit LCS Result 6.2 Spike Cone. 1.0 15.2 25 6031634001 Result 1.9 Dup Result 1.8 Qualifiers LCS % Rec 125 MS Result 55.8 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 7 %Rec Limits 79-126 MS %Rec 162 Max RPD Qualifiers % Rec Limits 42-141 M1 Qualifiers 21 Qualifiers Page 16 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: WET/10060 QC Batch Method: SM 2540C Associated Lab Samples: 6031634001 METHOD BLANK: 256744 Associated Lab Samples: 6031634001 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 256745 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 256746 Parameter Units Total Dissolved Solids mgil Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: SM 2540C Analysis

Description:

2540C Total Dissolved Solids Blank Result ND 6031551001 Result 988 6031650001 Result 2760 Reporting Limit 5.0 Dup Result 1000 Dup Result 2780 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 17 of 20

Project: AMEREN Pace Project No.: 6031634 QC Batch: MPRP/5175 QC Batch Method: EPA 3010 Associated Lab Samples: 6031634001 METHOD BLANK: 256791 Associated Lab Samples: 6031634001 Parameter Units Iron ug/L LABORATORY CONTROL SAMPLE: 256792 Parameter Units Iron ug/L MATRIX SPIKE SAMPLE: 256793 Parameter Units Iron ug/L SAMPLE DUPLICATE: 256801 Parameter Units Iron ug/L Date: 11/27/2007 04:46PM QUALITY CONTROL DATA Analysis Method: EPA6010 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

6010 MET Dissolved Blank Result Spike Cone. 10000 ND 6031610003 Result Reporting Limit LCS Result 10400 Spike Cone. 50.0 Qualifiers LCS % Rec 104 MS Result ND 10000 10100 6031610003 Result ND Dup Result RPD ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 63 %Rec Limits 80-120 MS %Rec 100 Max RPD Qualifiers % Rec Limits 75-125 Qualifiers 20 R1 Qualifiers Page 18 of 20

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. QUALIFIERS Project: AMEREN Pace Project No.: 6031634 DEFINITIONS DF Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL Adjusted Method Detection Limit. S Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) DUP Sample Duplicate RPD Relative Percent Difference Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. ANALYTE QUALIFIERS H6 Analysis initiated more than 15 minutes after sample collection. MO Matrix spike recovery was outside laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. R 1 RPD value was outside control limits. Date: 11/27/2007 04:46PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Lenexa, KS 66219 (913)599-5665 Page 19 of 20

Project: AMEREN Pace Project No.: 6031634 LabiD SampleiD 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID 6031634001 TW02-MID Date: 11/27/2007 04:46PM Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QUALITY CONTROL DATA CROSS REFERENCE TABLE QC Batch Method QC Batch EPA300.0 WETA/5808 EPA365.1 WETA/5813 SM 4500-H+8 WET/10025 EPA 180.1 WET/10030 SM 52108 WET/10031 SM 23208 WET/10035 EPA300.0 WETA/5816 EPA3010 MPRP/5159 EPA 120.1 WET/10046 SM 25400 WET/10053 SM 5310C WETA/5824 SM 2540C WET/10060 EPA3010 MPRP/5175 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analytical Analytical Method Batch SM 52108 WET/10032 EPA6010 ICP/4563 EPA6010 ICP/4576 Page 20 of 20

021706 FormWCO-KG~ Burns & McDonnell Engineering 9400 Ward Parkway Kansas City, Missouri 64114 Phone: (816) 333-9400 Fax: (816) 822-3494 Attention: j>C\\l.l.\\ Mc.-C:.o114'tiC.J*,. Project Number: ~-----*- Client Name: Request for Chemical Analysis and Chain of Custody Record Document Control No: Laboratory: Po.oG. ~ .. f\\Jyfi@l ~viceS }\\fie""'-~ Address: ~O r:t'-- 9 J,.... <(' L *

-\\.- -:'") !

La~. Reference No. or Ep1sode No. ~ -~ ca.re ~lva. . ~. City/State/Zip: l,e.1\\e.,.)(C\\ I ~"S. {c{c ?_f 9 i / /$ ~. ~:. // /'a~

,IV~ C.(

l9r3) 599-5l.clo5 1 I<J'fZI! / 1 /

  • !!2/

I --.;7 &* I I I Sample Type/ *. n i ~/ i <I o;?/ I I I ---~----------_..1__--,.---~c:r~\\1\\l~~. Cll'i' I,q;..;:) I I f I Matrix ! iii.~ / VJ/ ~~,.,..,,/ _/ 11 Telephone: i"O ~ ...fl / '< f:::.*/ /Jif I ~---,,---::----:--=---:-:--.---=------:---+---.-----l*.n a::

........
; :::1 v.Jl Sample Number Sample Event S a~ple Depth Sample I ~ §. 1 -..Lt;' <o p,; r i ~ /

(In feet) i Collected

Q

!zo. I Qi7 r~?,...../0~ '-'; / Group or Sa~ple Sample T 5-

g
g i

! / N ~ {tl/ L ""'"; * }w I 'j_(~ 6>9-'----- A m_e.l-e..-11 SWMU Na~e ~*n: - Desi[Jn*~:-*Round Yea. I To Date Time

.:::i ell C!l !
/ ~I r8; f...-Q/ "/ v'l /

Remarks 1--**** --+-- -*--- *w-o2-Mil\\ Xi. -li~ Xi~l~ B~z-v &¥*.) ~~~-i~f3.~~ I f-------- -+--. -**---**-*** I i I i CJ.:J/ ---.L.. ___ j___ -j -~

j I /
  • I

-~ I 1-----!---1 ----+----4------+----+--,* +-+ --n- ___ i +-+---: t==r c ~=o:::::~ ! _ _j_ 1--+--+- i i I 1-------t---+---+----+-----------l---+------'------+----+--r 1-! 1 i 1 imr---- 1--------.....l...-----..L.-------'---'-..... ---'------'---'--..L.--L__-. ----'------'-=P= _... _... I


1

, L~ ~--*r; __ ~rr:z::~*-~~~:z~~4~~fi:.;z:_;:;_~=_,::;::;_~~=-~--h:~==~=::-::-:----..-=---------- Relinguished. B~ ... ~"""'. ~:.*ll. q I.' n~t"a e!TiQ1!:\\ r_* Ice P __ r_o_._._sseept11 m Container: ITempe.. rature Upon Receipt: 1.~ ~ ~ / O£.""' ""'" 'yr l?lr>l Yes ~-~ No D I 0, ~.. L FWnq~;;;;:fi~91U;; / -*.... Laboratory Comments: Special Instructions:

2.
      • -**-*-* ****-***-v:..-:"*-----**** - --.....-,--'*-...,.-..--... -~..,.,_.
aAn.Jyficat Sample Condition Upon Receipt Courter. 0 Fed Ex.~UPS 0 USPS 0 Client 0 Commercial 0 Paee Other Project.,;#..
;:::;::(o::o=3=/Ce=.3=7==:::;-

ootional Proj. Due Date: Pro]. Nama: Tracking#:-------- custody Seal on Cooler/Box Present: Dyes Grno Seals intact: 0 yes ~no Packing Material: D Bubble Wrap D Bubble Bags 0 None ~ Other 2 r r""'- -v c... Thermometer Used Type of Ice: '({1). Blue None 0 Samples on ice cacllng process ties begun Cooler Temperature O.li.- Biological Tissue is Froten: Ye5 No t* Data and Initials or person examining contents: ~ I Oe T&ll)p should be above freezing to 6'C Comments: V-"' Chain of Custod~ Present: &!Yes ONo DNIA 1.

  • Chain of CustodY. Filled Out ElYes ONo DNIA 2.

Chain of <;;ustody Re1fnqulshed*: liYes DNo DNIA 3. Sampler Name & Signature on COC: iaYes ONe DNIA 4. Samples Arrived witllln Hold Time: 0Yes ONe DNIA 5. Short Hold Time Analysis (<72hr): ~Yes ONo QN/A 6.~.f' c;-{ 'f1,.MAj RU$h Turn Around l:ima Requested; DY"'-' llifNo DNIA,7, 1\\l () -'7 IN 0 *7... + l.krV?O"P Suffldent Volume~

  • ~*es ONo DNIA '11 Correct Contaiflers *Used:

t:ih'es DNo ON/A 9. -Pace Contairters Used: &,. ONo ON/A Containers Intact: ~Yen lJNo DNIA 10. Filtered volume rec~ived for l;lis~olveQ t~ta DYes G!!No DNJA 11. Sample latJels match COC: l:JYes ONo DN/A 12. -Includes date!time/IDIAnaiYsis Matril'l:

  • ~c All containers needing preseFVation have been checked7**

'iaYAR ONo UN/A 13. f All* containers needing preservation are found to be In

01.

compOance Vw1th EPA recomrmmdation. !RYes ONo ON/A' DYes t:!No 'Initial when lLot ff Qf added fex~ep[~ns; VOA, coliform, TOO, O&G. WI*DRO ('K~i.er) completed preservative Samples checked for dechlorination: DYes []No ~lA 14. Heads pace in VOA Vials '>6mm}: DYes DNa ~/A 15. Trip Blank Present: DYes DNo (Y,N/A 16. Trip Blank Custoa!y Seals Present DYes ONo fa:NI.A. .Pace Trip Blaflk Lot# (if purcha$ed)' ~ Client Notification/ Resolution: Field Data Required? y f N Person (;(lntactoo:~---~------~- DateJTime-: Comments/ R.esolution: ________________ _..._ ___________________ _ Projeet M-anager Reviewl Da~*= ----------------- Note: \\')4henever there is a dlserepancy affedin9 Nor:th CaroUna compliance samples, a cupy of.lhls form will be serll to the. NOOh Carolina.DEHNR Cerlllleation Office ( r.e ou~ of hold,, il:lcone&l presemtive, out of temp, incorrect contailers) F-AlLC003rev.3, 11September2006

ace Analytical New Orleans Laboratory November 21, 2007 Client Services Pace Kansas 9608 Loiret Boulevard Lenexa, KS 66219 RE: Project: 2076201 RE: Project 10: 6031634

Dear Client Services:

Enclosed are the analytical results for sample(s) received by the laboratory on November 16,2007. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Karen Brown REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, execpt in full, without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006

ace Ana/yfical New Or/eafls Laboratory Client: P ASI Kansas Project ID: 603163 4 Client Sample ID TW02-MID Sample Cross Reference Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Lab ID Matrix 60316340 WEtter Project: 2076201 Collection Date/Time 11!15/07 15:10 Received Date/Time I 1/16/07 09:25 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/21/21)1)717:1)1 :2(1 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076201 Sample Receipt Condition. 1\\1l sru11ples were received in accordru1ce with EPA protocol Holding Times: 1\\1l holding times were met. Blru1ks: 1\\1l blru1k reslllts were below repmting limits. Laboratory Control Srunples: i\\11 LCS recoveries were within QC limits. Matrix Spikes ru1d Dllplicates: MS or MSD recoveries olltside of QC limits me qllalified in the Report ofQllality Control section. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 1 1:21:200? 1?:01:56

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2076201 Analytical Method Batch Sample used for QC SM 4500-SiC 94446 Client sample MW-5S fi*om project 2076200 For the sru11ple llsed as the original for the DOP or MS/MSD for ihe batch: Project srunple means a srunple from this pmject was llsed Client srunple meru1s a sample from the srune client bt1t in a different project was med. Batch srunple meru1s a sample fi*om the a different client was 11sed Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/21/21)1)717:1)1 :51)

Sample Results Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory Client ID: TW02-MID Project ID: 6031634 Lab ID: 6031634001

== Description:== None Analyte Method Batch DF Qu Result Silica SM 4500-Si 94446 5 1 JHI.nuneter(iS) reported 't\\""D denote~ 1\\ot Dctcdo:l at OJ above thcad~tu~to:l rcport:n,g ::.rn:t OJ PQL 1v1Dl. Ucnotc~ method. detect :on.:m:t l:m:t~ arc corrected for ~amp.c ~:zc, d:.ut:on and n10::<:turc content :f app.:cab.c Qu.:~t~ qua.:f.cr~. Spcc:f.c qua.:f.cr~ arc dcf.ncd at the end of the report Dl 28.5 Fm n.lo:o<:turc rcsu.t~, wet denote~ rcsu.t :~not corrected for mo:~turc a:ndn/~'\\ denote~ not app.:cab.c Rcgu.atory.:m:t may denote anactua. rcgu.atory.:m.t OJ ac.:cnt-rcquc~tcd not:f.cat:on.:m:t Client: PASI Kansas Project: 2076201 Site: None Matrix: Water Collected: 1l/15/07 %Moisture: Recciyed: nia Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/16/07 {;nits Reporting Limit Prep. Reg. Analysis Limit 1ng/L 5.00 20-Nov-07 20-Nov-07 17:19 TAE ll/21/21)1)717:1)2:1)2 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47270

Inorganics Quality Control ace Ana/yfical New Or/eafls Laboratory Project: 2076201 LCS LCS LCS MS Sample MS MSD MS MSD MSD Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 DL"P Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 QC Limits Max Qu Parameter Batch Blank ARL L"nits Spike Found%Rcc Spike Found Found Found %Rcc %Rcc RPD RPD LCS MS/MSD RPD Silic8 94446 :sro 1.00 n1g/L 10 11.75 17.37 Silic8 94446 n1g/L 10 10.91 109 11.75 11 denote iS ncm*er:y oubide of QC limib. l\\""0 denotesl"iotDeteded at or abqvethe adju:ded :reporting1imit or PQL. 1\\JSll\\JSD RPD i:s calculated "lia S\\Y-846 ru]e:s on the b~iiS of iSJlil.red ~Sample concentrntion:s rather than iSJlil'e recoYerleiS.

56.

75 125 90 110 20 ll/21/21)1)717:1)2:1)5 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-1)421)2 ES. Dept f?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47271) Ql

Qualifier Summary ace Ana/yfical New Or/eafls Laboratory Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 Qualifier Dl Ql Project: 2076201 Qualifier Description The imalysis "'VI.' as perfonned at 8 dilution due to the high ru1Etlyte concenu*ation. The matrix spike recoveries me poor. Acceptable method perfonmmce for this *malyte has been demonstrated by the laboratory control sru11ple recO'\\I*eJy. ll/21/21)1)717:1)2:1):-1 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

November 28, 2007 PAT HIGGINS BURNS & MCDONNELL 9400 WARD PARKWAY Kansas City, MO 64114 RE : Project: Ameren 46691 Pace Project No.. 6031729

Dear PAT HIGGINS:

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Enclosed are the analytical results for sample(s) received by the laboratory on November 17,2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, . ll.,,.../...--, l..JrWifJ,_.()..I /}1---- Angie Brown Angie.Brown@pacelabs.com Project Manager A2LA Certification Number: 2456.01 Arkansas Certification Number: 05-008-0 Illinois Certification Number: 001191 Iowa Certificalion Number: 118 Kansas/NELAP Certificalion Number: E-1 0116 Louisiana Certificalion Number: 03055 Oklahoma Certification Number: 9205/9935 Utah Certificalion Number: 9135995665 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Page 1 of 21

Project: Ameren 46691 Pace Project No.: 6031729 LabiD Sample ID 6031729001 TW-02END SAMPLE

SUMMARY

Matrix Date Collected Date Received Water 11/17/07 07:25 11/17/07 17:00 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Page 2 of 21

Project: Ameren 46691 Pace Project No.: 6031729 LabiD Sample ID 6031729001 TW-02END SAMPLE ANALYTE COUNT EPA 120.1 EPA 180.1 EPA 300.0 EPA365.1 EPA365.4 EPA6010 EPA6010 SM 23208 SM 2540C SM 25400 SM4500-H+8 SM 52108 SM 5310C Method REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Analytes Reported 4 8 3 Lenexa, KS 66219 (913)599-5665 Page 3 of 21

Project: Ameren 46691 Pace Project No.: 6031729 Sample: TW-02END Parameters 6010 MET ICP Barium Calcium Iron Magnesium Manganese Potassium Sodium Strontium 6010 MET ICP, Lab Filtered Iron 120.1 Specific Conductance Specific Conductance 180.1 Turbidity Turbidity 23208 Alkalinity Alkalinity,Bicarbonate (GaG03) Alkalinity, Carbonate (GaGO) Alkalinity, Total 2540C Total Dissolved Solids Total Dissolved Solids 2540D Total Suspended Solids Total Suspended Solids 4500H+ pH, Electrometric pH at 25 Degrees G 52108 BOD, 5 day BOD, 5 day 300.0 IC Anions Nitrate as N 300.0 IC Anions 28 Days Chloride Fluoride Sulfate 365.1 Phosphate, Ortho as P Orthophosphate as P Date: 11/28/2007 04:54PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Lab ID: 6031729001 Collected: 11/17/07 07:25 Received: 11/17/07 17:00 Matrix: Water Results Units Report Limit DF Prepared Analyzed GAS No. Analytical Method: EPA 6010 Preparation Method: EPA 3010 870 ug/L 10.0 11/19/07 00:00 11/26/07 17:11 7440-39-3 114000 ug/L 100 11/19/07 00:00 11/26/07 17:11 7440-70-2 7630 ug/L 50.0 11/19/07 00:00 11/26/07 17:11 7439-89-6 25700 ug/L 50.0 11/19/07 00:00 11/27/07 12:13 7439-95-4 275 ug/L 5.0 11/19/07 00:00 11/26/07 17:11 7439-96-5 3350 ug/L 500 11/19/07 00:00 11/26/07 17:11 7440-09-7 7320 ug/L 500 11/19/07 00:00 11/26/07 17:11 7440-23-5 581 ug/L 10.0 11/19/07 00:00 11/26/07 17:11 7440-24-6 Analytical Method: EPA 6010 Preparation Method: EPA 3010 ND ug/L 50.0 11/20/07 00:00 11/26/07 14:55 7439-89-6 Analytical Method: EPA 120.1 670 umhos/cm Analytical Method: EPA 180.1 103 NTU Analytical Method: SM 2320B 400 mg/L ND mg/L 400 mg/L Analytical Method: SM 2540G 560 mg/L Analytical Method: SM 2540D 12.0 mg/L Analytical Method: SM 4500-H+B 7.2 Std. Units 1.0 5.0 20.0 20.0 20.0 5.0 5.0 0.10 11/19/07 00:00 11/19/07 11:30 11/20/07 19:17 11/20/07 19:17 11/20/07 19:17 11/20/07 15:44 11/20/07 11:39 11/19/07 13:30 Analytical Method: SM 5210B Preparation Method: SM 5210B ND mg/L 2.0 11/19/07 13:34 11/24/07 10:23 Analytical Method: EPA 300.0 Qual H1 H6 H1 ND mg/L 1.0 11/19/07 13:14 14797-55-8 H1 Analytical Method: EPA 300.0 6.3 mg/L 1.0 0.34 mg/L 0.20 26.2 mg/L 1.0 Analytical Method: EPA 365.1 ND mg/L 0.10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 11/21/07 17:18 16887-00-6 11/21/07 17:18 16984-48-8 11/21/0717:18 14808-79-8 11/19/07 11:30 H1 Page 4 of 21

Project: Ameren 46691 Pace Project No.: 6031729 Sample: TW-02END Parameters 365.4 Total Phosphorus Phosphorus 5310C TOC Total Organic Carbon Date: 11/28/2007 04:54PM ANALYTICAL RESULTS Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 LabiD: 6031729001 Collected: 11/17/07 07:25 Received: 11/17/07 17:00 Matrix: Water Results Units Analytical Method: EPA 365.4 0.32 mg/L Analytical Method: SM 5310C 1.2 mg/L Report Limit DF Prepared 0.10 1.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analyzed CAS No. Qual 11/27/07 18:08 7723-14-0 11/20/07 00:00 7440-44-0 Page 5 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10036 QC Batch Method: SM 2320B Associated Lab Samples: 6031729001 METHOD BLANK: 255963 Associated Lab Samples: 6031729001 Parameter Units Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) LABORATORY CONTROL SAMPLE: Parameter Alkalinity, Tolal SAMPLE DUPLICATE: 255965 Parameter Alkalinity, Carbonate (CaCO) Alkalinity, Tolal Alkalinity,Bicarbonate (CaC03) Date: 11/28/2007 04:54PM mgil mgil mgil 255964 Units mgil Units mgil mgil mgil QUALITY CONTROL DATA Analysis Method: Analysis

Description:

SM 2320B 2320B Alkalinity Blank Reporting Result Spike Cone. 500 ND ND ND 6031630005 Result ND 483 483 Limit LCS Result 462 Dup Result 20.0 20.0 20.0 ND 475 475 Qualifiers LCS % Rec 92 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 2 2 %Rec Limits 90-110 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 6 6 6 Page 6 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WETA/5817 QC Batch Method: EPA300.0 Associated Lab Samples: 6031729001 METHOD BLANK: 256061 Associated Lab Samples: 6031729001 Parameter Units Nitrate as N mgil LABORATORY CONTROL SAMPLE: 256062 Parameter Units Nitrate as N mgil MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 256064 6031729001 QUALITY CONTROL DATA Analysis Method: Analysis

Description:

Blank Result Reporting Limit EPA300.0 300.0 IC Anions Qualifiers ND 1.0 Spike LCS LCS Cone. Result % Rec 5 5.0 99 256065 MS MSD Spike Spike MS MSD %Rec Limits 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L SAMPLE DUPLICATE* 256063 Parameter Units Nitrate as N mgil Date: 11/28/2007 04:54PM ND 5 6031729001 Result ND 5 Dup Result 4.3 ND 4.4 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 86 0 Max RPD 87 11 61-128 2 7 Qualifiers Page 7 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: MPRP/5159 QC Batch Method: EPA 3010 Associated Lab Samples: 6031729001 METHOD BLANK: 256083 Associated Lab Samples: 6031729001 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L LABORATORY CONTROL SAMPLE: 256084 Parameter Units Barium ug/L Calcium ug/L Iron ug/L Magnesium ug/L Manganese ug/L Potassium ug/L Sodium ug/L Strontium ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 256085 6031612002 Parameter Units Result Barium ug/L 271 Calcium ug/L 128000 Iron ug/L 21000 Magnesium ug/L 10200 Manganese ug/L 1150 Potassium ug/L 3400 Sodium ug/L 27800 Strontium ug/L 233 QUALITY CONTROL DATA Analysis Method: EPA6010 6010 MET Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 10.0 ND 100 ND 50.0 ND 50.0 ND 5.0 ND 500 ND 500 ND 10.0 Spike LCS LCS Cone. Result % Rec 1000 1040 104 10000 10900 109 10000 10500 105 10000 10700 107 1000 1060 106 10000 10300 103 10000 10200 102 1000 1030 103 256086 MS MSD Spike Spike MS MSD Cone. Cone. Result Result 1000 1000 1210 1230 10000 10000 133000 136000 10000 10000 29700 30200 10000 10000 20100 20100 1000 1000 2080 2110 10000 10000 13400 13500 10000 10000 36400 36700 1000 1000 1200 1210 Date: 11/28/2007 04:54PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Limits Qualifiers 80-120 80-120 80-120 80-120 80-120 80-120 80-120 80-120 MS MSD %Rec Max % Rec % Rec Limits RPD RPD Qual 94 96 75-125 7 47 75 75-125 2 8 MO 87 91 75-125 2 12 99 100 75-125 0 7 93 95 75-125 9 100 101 75-125 7 87 89 75-125 12 96 98 75-125 11 Page 8 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WETA/5818 QC Batch Method: EPA 365.1 Associated Lab Samples: 6031729001 METHOD BLANK: 256130 Associated Lab Samples: 6031729001 Parameter Units Orthophosphate as P mgil LABORATORY CONTROL SAMPLE: 256131 Parameter Units Orthophosphate as P mgil MATRIX SPIKE SAMPLE: 256132 Parameter Units Orthophosphate as P mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: EPA365.1 Analysis

Description:

365.1 Phosphorus, Ortho Blank Result Spike Cone. 2 ND 6031729001 Result Reporting Limit LCS Result 2.1 Spike Cone. 0.10 ND 2 Qualifiers LCS % Rec 104 MS Result 2.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 90-110 MS %Rec 102 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers % Rec Limits 90-110 Lenexa, KS 66219 (913)599-5665 Qualifiers Page 9 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10043 QC Batch Method: EPA 180.1 Associated Lab Samples: 6031729001 METHOD BLANK: 256134 Associated Lab Samples: 6031729001 Parameter Units Turbidity NTU LABORATORY CONTROL SAMPLE: 256135 Parameter Units Turbidity NTU SAMPLE DUPLICATE: 256136 Parameter Units Turbidity NTU Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

EPA 180.1 180.1 Turbidity Blank Result Reporting Limit Qualifiers Spike Cone. 10 ND 6031729001 Result 103 LCS Result 9.9 Dup Result 1.0 100 LCS % Rec 99 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 2 %Rec Limits 80-120 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 10 Page 10 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10044 QC Batch Method: SM 5210B Associated Lab Samples: 6031729001 METHOD BLANK: 256143 Associated Lab Samples: 6031729001 Parameter Units BOD, 5 day mgil LABORATORY CONTROL SAMPLE: 256144 Parameter Units BOD, 5 day mgil SAMPLE DUPLICATE: 256145 Parameter Units BOD, 5 day mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: SM 5210B Analysis

Description:

5210B BOD, 5 day Blank Result Spike Cone. 198 ND 6031732003 Result 116 Reporting Limit LCS Result 206 Dup Result 2.0 102 Qualifiers LCS % Rec 104 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 13 %Rec Limits 85-115 Max RPD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Qualifiers Qualifiers 17 Page 11 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10045 QC Batch Method: SM 4500-H+B Associated Lab Samples: 6031729001 SAMPLE DUPLICATE: 256146 Parameter Units pH at 25 Degrees C Std. Units Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: Analysis

Description:

6031729001 Result 7.2 Dup Result SM 4500-H+B 4500H+B pH RPD 7.2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 Max RPD 5 H6 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 12 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10046 QC Batch Method: EPA 120.1 Associated Lab Samples: 6031729001 METHOD BLANK: 256157 Associated Lab Samples: 6031729001 Parameter Units Specific Conductance umhos/cm SAMPLE DUPLICATE: 256159 Parameter Units Specific Conductance umhos/cm Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: EPA 120.1 Analysis

Description:

120.1 Specific Conductance Blank Reporting Result Limit Qualifiers ND 1.0 6031634001 Dup Result Result RPD 616 617 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD 0 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Lenexa, KS 66219 (913)599-5665 Page 13 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10053 QC Batch Method: SM 2540D Associated Lab Samples: 6031729001 METHOD BLANK: 256334 Associated Lab Samples: 6031729001 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256335 Parameter Units Total Suspended Solids mgil SAMPLE DUPLICATE: 256336 Parameter Units Total Suspended Solids mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis

Description:

2540D Total Suspended Solids Blank Result ND 6031612002 Result 40.0 6031619001 Result 50.0 Reporting Limit Dup Result Dup Result 5.0 40.0 50.0 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 0 0 Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 14 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WETA/5824 QC Batch Method: SM 5310C Associated Lab Samples: 6031729001 METHOD BLANK: 256545 Associated Lab Samples: 6031729001 Parameter Units Total Organic Carbon mgil LABORATORY CONTROL SAMPLE: 256546 Parameter Units Total Organic Carbon mgil MATRIX SPIKE SAMPLE: 256548 Parameter Units Total Organic Carbon mgil SAMPLE DUPLICATE: 256547 Parameter Units Total Organic Carbon mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: SM 5310C Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

5310C Total Organic Carbon Blank Result Spike Cone. 5 ND 6031651001 Result Reporting Limit LCS Result 6.2 Spike Cone. 1.0 15.2 25 6031634001 Result 1.9 Dup Result 1.8 Qualifiers LCS % Rec 125 MS Result 55.8 RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 7 %Rec Limits 79-126 MS %Rec 162 Max RPD Qualifiers % Rec Limits 42-141 M1 Qualifiers 21 Qualifiers Page 15 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WET/10060 QC Batch Method: SM 2540C Associated Lab Samples: 6031729001 METHOD BLANK: 256744 Associated Lab Samples: 6031729001 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 256745 Parameter Units Total Dissolved Solids mgil SAMPLE DUPLICATE: 256746 Parameter Units Total Dissolved Solids mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: SM 2540C Analysis

Description:

2540C Total Dissolved Solids Blank Result ND 6031551001 Result 988 6031650001 Result 2760 Reporting Limit 5.0 Dup Result 1000 Dup Result 2780 Qualifiers RPD RPD REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Max RPD Max RPD 5 5 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers Qualifiers Lenexa, KS 66219 (913)599-5665 Page 16 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: MPRP/5175 QC Batch Method: EPA 3010 Associated Lab Samples: 6031729001 METHOD BLANK: 256791 Associated Lab Samples: 6031729001 Parameter Units Iron ug/L LABORATORY CONTROL SAMPLE: 256792 Parameter Units Iron ug/L MATRIX SPIKE SAMPLE: 256793 Parameter Units Iron ug/L SAMPLE DUPLICATE: 256801 Parameter Units Iron ug/L Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: EPA6010 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

6010 MET Dissolved Blank Result Spike Cone. 10000 ND 6031610003 Result Reporting Limit LCS Result 10400 Spike Cone. 50.0 Qualifiers LCS % Rec 104 MS Result ND 10000 10100 6031610003 Result ND Dup Result RPD ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 63 %Rec Limits 80-120 MS %Rec 100 Max RPD Qualifiers % Rec Limits 75-125 Qualifiers 20 R1 Qualifiers Page 17 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WETA/5833 QC Batch Method: EPA300.0 Associated Lab Samples: 6031729001 METHOD BLANK: 257025 Associated Lab Samples: 6031729001 Parameter Chloride Fluoride Sulfate LABORATORY CONTROL SAMPLE: Chloride Fluoride Sulfate Parameter Units mgil mgil mgil 257026 mgil mgil mgil Units MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 257027 6031470001 QUALITY CONTROL DATA Analysis Method: EPA300.0 300.0 IC Anions Analysis

Description:

Blank Reporting Result Limit Qualifiers ND 1.0 ND 0.20 ND 1.0 Spike LCS LCS Cone. Result % Rec 5 5.0 101 2 2.1 107 15 14.1 94 257028 MS MSD Spike Spike MS MSD %Rec Limits 90-110 90-110 90-110 MS MSD Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Qualifiers %Rec Lenexa, KS 66219 (913)599-5665 Max Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD RPD Qual Chloride Fluoride Sulfate SAMPLE DUPLICATE: 257029 Chloride Fluoride Sulfate Parameter Date: 11/28/2007 04:54PM mg/L mg/L mg/L mgil mgil mgil Units 98.8 100 100 216 214 ND 100 100 125 124 258 100 100 357 357 6031710001 Dup Result Result RPD 1020 1030 ND 5.7J 287 295 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c 117 115 57-123 6 123 122 80-120 10 MO 99 99 60-133 0 12 Max RPD Qualifiers 14 13 3 11 Page 18 of 21

Project: Ameren 46691 Pace Project No.: 6031729 QC Batch: WETA/5845 QC Batch Method: EPA 365.4 Associated Lab Samples: 6031729001 METHOD BLANK: 257965 Associated Lab Samples: 6031729001 Parameter Units Phosphorus mgil LABORATORY CONTROL SAMPLE: 257966 Parameter Units Phosphorus mgil MATRIX SPIKE SAMPLE: 257967 Parameter Units Phosphorus mgil SAMPLE DUPLICATE: 257968 Parameter Units Phosphorus mgil Date: 11/28/2007 04:54PM QUALITY CONTROL DATA Analysis Method: EPA365.4 Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 Analysis

Description:

365.4 Phosphorus Blank Result Spike Cone. 2 ND 6031813001 Result Reporting Limit LCS Result 2.0 Spike Cone. 0.10 32.9 2 6031729001 Result 0.32 Dup Result 0.36 Qualifiers LCS % Rec 102 MS Result 35.3 RPD 11 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c %Rec Limits 90-110 MS %Rec 116 Max RPD Qualifiers % Rec Limits 58-132 Qualifiers 12 Qualifiers Page 19 of 21

Pace Analytical Services, Inc. 9608 Lo1ret Blvd. QUALIFIERS Project: Ameren 46691 Pace Project No.: 6031729 DEFINITIONS DF Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL Adjusted Method Detection Limit. S Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) DUP Sample Duplicate RPD Relative Percent Difference Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited analytes. ANALYTE QUALIFIERS H 1 Analysis conducted outside the EPA method holding time. H6 Analysis initiated more than 15 minutes after sample collection. MO Matrix spike recovery was outside laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. R 1 RPD value was outside control limits. Date: 11/28/2007 04:54PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Lenexa, KS 66219 (913)599-5665 Page 20 of 21

Project: Ameren 46691 Pace Project No.: 6031729 LabiD SampleiD 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END 6031729001 TW-02END Date: 11/28/2007 04:54PM Pace Analytical Services, Inc. 9608 Lo1ret Blvd. Lenexa, KS 66219 (913)599-5665 QUALITY CONTROL DATA CROSS REFERENCE TABLE QC Batch Method QC Batch SM 23208 WET/10036 EPA300.0 WETA/5817 EPA3010 MPRP/5159 EPA365.1 WETA/5818 EPA 180.1 WET/10043 SM 52108 WET/10044 SM 4500-H+8 WET/10045 EPA 120.1 WET/10046 SM 25400 WET/10053 SM 5310C WETA/5824 SM 2540C WET/10060 EPA3010 MPRP/5175 EPA300.0 WETA/5833 EPA365.4 WETA/5845 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. {h~~~:-c Analytical Analytical Method Batch EPA6010 ICP/4563 SM 52108 WET/10051 EPA6010 ICP/4576 Page 21 of 21

Request for Chemical Analysis and Chain of Custody Record I. 021706 FormWCD-KC1 &.::-$f7-L~ Burns & McDonnell Engineering 9400 Ward Parkway Kansas City, Missouri 64114 Phone: (816) 333-9400 Fax: (816) 822-3494 Attention: "'\\=6~ I Laboratory: ___ !itc..e.. A-atr.;f I(! a I Address: q LaO~ [_~'\\ \\e+ SvJ Document Control No: f--- Lab. Reference No. or Episode No.. I I' Ill City/State/Zip: ~e,../((L }.(_ S {_p lP Z I q Telephone: 0 ( \\ '?:J.S-..-

I / /~~~~

/ / / /' '::}:;;~ ~ ~\\_r-t s*W<Rc; I I / 1 / ;;J'~$ ~~ I I -~7~~~ J-1 LR 0;. 9 ' Sample Type I I ~/ II / l J....~/ ~7' WI rrY; i 1r..-..,.o.~-...;;E -,a ~ ~~ I ~~ A ¥II v' ~- 1 Matrix l~i /.]!}_/ si ! t:!/ ~ t;' Project Number* Client Name: s_ ample Number Sample Event Sa~ple Depth ! Sample ~§~ /--P;'-:::;,;L-.j-5&' 9


G-ro-up_o_r_~----s~n--Sample____

r----~,--- (mfleet) Collected ! l ~ gj zoi /~11/ ');}/-t~l-5' I SWMUN"" I__ p==o:;~>> R:d Y"'~; From ' ~Ji;i, ~ ~ ~ -~~" (. (}4 _v _ __~'f ___ xrt;-: 1 ~*~-~-~-----~ R~~ r 1 r 1'\\ ')i ""'): u<<tt.9 ~ 16~.. 1.... i . \\ f Ill)! H8f~t.- i i I ~ ~~ i I ! -i------i-: --: _J__~_ ; _: ___ _ I I


j

. ----1 I I c?'.?/ 1-----!--------+--+---+---!---+-----t--+--+--:----i--+'-! I I !-1--- ------ - - I t -* I I t* l l I 1---


~---**-

I i +-----**-- i ---- -I l

            • ---l Temperature Up~n Receipt

~!f¥--l-~IP!4~~~~===!._ _j__~_,_Jj ~-

Sample Condition Upon Receipt Client Name: _.._t?_fll.;........,..;_,_k'Wf_o:._O_,,..._... _R._I(_ Courier: 0 Fed Ex 0 UPS 0 USPS ~Client D Commercial D Pace other Tracking#:-------- Project# wv-~ 112--., Ootlonal Proj. Due Date: Proj. Name: Custody Seal on Cooler/Box Present: D yes fgp oo Seals intact: 0 yes 0 oo Packing Material: ~Ubble Wrap oeubble Bags D None 0 Other Thermo.meter Us~c.l ~

  • I &6 Type of Ice: (J'!jD Blue None D Samples on ice, cooling process has begun Cooler Temperature

~-" Biological Tissue Is Frozen~ I Date and Initials of pel'$01\\ z.azinlng contents: .J,...,; If 'i ~ 71 Temp should be above. freezing to G'C Comments: Chain of Custody Present: !!il>Yes ONo ON/A 1. Chain of Custody Filled Out: ~** DNo DNIA 2. Chain of CUstody Relinquished: ~es ONo ON/A 3. Sampler Name & Signature on CDC: elves DNo DNIA 4. Samples Arrived within Hold Time: ~Yes DNo ON/A 5. Short Hold Time Analysis {<72hr); ~e* DN<:> fJNIA 6. Bot.> "'1-NO~ ,........ 14.> :M*:y_ ~ rft...- p Rush Turn Arol:lnd Time Requested*~ DYes 1:Bfio ON/A,7. Cl... t ~f k\\J r Sufflti~nt Volume: 0es r:JNa []NJA :s. ,e;--- Corre<..1 ContaiBers Used: 0Yes ON() DNIA 9. -Pace Containers Used: l;Wc~ ON<> ON//\\ Containers Intact: @r'es ON<:> ON/A 10. Filtered volume re~ived for Dissolved. tests DYes~~ 'SNrA 11. Sample Labels match COC: e'Yes ONo ON! A,12.

  • Includes date/time/IDIAnalysls Matrix:

,...,.:tAr All containers needing preservation ha\\'e been check.&d. l>>y&$ DNo DNIA 13. All containers needing preservation are found to be in 11t'fes DNo ON IA compliance \\Mth EPA re~ommendation. exo;epjions: VOA,. co:lform, TOC, O&G, WI-ORO {water) ~es ONo lniUal when completed ~ 1: 1 Lot # of added preservative Samples checked for dechlorination: DYes DNo ~/A 14. Headspace in VOA Vials ( >6mm): DYes DNo 01-liA 15. Trip Blank Present: DYes DNo lpNIA 16. Trip Blank Custody Seals Present DYes DNo l'iiNIA Pace Trip Blank Lot.# (if purchased): f'IA-Client Notification/ Resolution: Field Data Required? Y I N Person Contacted; _____________ Date/Time: Commenl<>/ Resolution:--------------------------------------- Project Manager Review1 Date: ----------------- Note: Whenever there Is a discrepancy affecting North Carolina compliance samples, atopy of this form Mil be sent tf.l the North Carolina.DEHNR Oertlficalion Office ( l~e out of hold, incorJect preseNative, out of temP', Incorrect containeFS) F-ALLC003r!lV.3, 11 Septembef2006

ace Analytical New Orleans Laboratory November 16, 2007 Client Services Pace Kansas 9608 Loiret Boulevard Lenexa, KS 66219 RE: Project: 2075996 RE: Project 10: 6031330

Dear Client Services:

Enclosed are the analytical results for sample(s) received by the laboratory on November 09, 2007. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Karen Brown REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, execpt in full, without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006

ace Ana/yfical New Or/eafls Laboratory Client: P ASI Kansas Project ID: 603133 0 Client Sample ID TW-01 TW-O! MID Sample Cross Reference Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Lab ID 60313300 60313300 Matrix WEtter WEtter Project: 2075996 Collection Date/Time 11/08/07 I 0:30 11/08/07 13:00 Received Date/Time 11!09/07 17:35 11!09/07 17:35 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/16/21)1)71 0:41:25 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2075996 Sample Receipt Condition. 1\\ll sru11ples were received in accordru1ce with EPA protocol Holding Times: 1\\ll holding times were met. Blru1ks: 1\\ll blru1k reslllts were below repmting limits. Laboratory Control Srunples: i\\11 LCS recoveries were within QC limits. Matrix Spikes ru1d Dllplicates: All MS/MSD recoveries or dt1pli.cate RPDs were "1thin QC limits. Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 1 1/16:200? 10:41:55

Project Narrative ace Ana/yfical New Or/eafls Laboratory Project: 2075996 Analytical Method Batch Sample used for QC SM 4500-SiC 94226 Client sample T\\V -0 I END from project 2076003 For the sru11ple llsed as the original for the DOP or MS/MSD for ihe batch: Project srunple means a srunple from this pmject was llsed Client srunple meru1s a sample from the srune client bt1t in a different project was med. Batch srunple meru1s a sample from the a different client was 11sed Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 ll/16/21)1)71 0:41 :5H

Sample Results Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory Client ID: TW-01 Project ID: 6031330 Lab ID: 6031330001

== Description:== None Analyte Method Batch DF Qu Result Silica SM 4500-Si 94226 5 1 JHI.nuneter(iS) reported 't\\""D denote~ 1\\ot Dctcdo:l at OJ above thcad~tu~to:l rcport:n,g ::.rn:t OJ PQL 1v1Dl. Ucnotc~ method. detect :on.:m:t l:m:t~ arc corrected for ~amp.c ~:zc, d:.ut:on and n10::<:turc content :f app.:cab.c Qu.:~t~ qua.:f.cr~. Spcc:f.c qua.:f.cr~ arc dcf.ncd at the end of the report Dl 3Ll Fm n.lo:o<:turc rcsu.t~, wet denote~ rcsu.t :~not corrected for mo:~turc a:ndn/~'\\ denote~ not app.:cab.c Rcgu.atory.:m:t may denote anactua. rcgu.atory.:m.t m ac.:cnt-rcquc~tcd not:f.cat:on.:m:t Client: PASI Kansas Project: 2075996 Site: None Matrix: Water Collected: 11/08/07 %Moisture: Recciyed: nia Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/09/07 {;nits Reporting Limit Prep. Reg. Analysis Limit 1ng/L 5.00 15-Nov-07 15-Nov-07 13:22 TAE ll/16/21)1)71 0:42:1)1 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47270

Sample Results Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory Client ID: TW-01 MID Project ID: 6031330 Lab ID: 6031330002

== Description:== None Analyte Method Batch DF Qu Result Silica SM 4500-Si 94226 5 1 JHI.nuneter(iS) reported 't\\""D denote~ 1\\ot Dctcdo:l at OJ above thcad~tu~to:l rcport:n,g ::.rn:t OJ PQL 1v1Dl. Ucnotc~ method. detect :on.:m:t l:m:t~ arc corrected for ~amp.c ~:zc, d:.ut:on and n10::<:turc content :f app.:cab.c Qu.:~t~ qua.:f.cr~. Spcc:f.c qua.:f.cr~ arc dcf.ncd at the end of the report Dl 28.6 Fm n.lo:o<:turc rcsu.t~, wet denote~ rcsu.t :~not corrected for mo:~turc a:ndn/~'\\ denote~ not app.:cab.c Rcgu.atory.:m:t may denote anactua. rcgu.atory.:m.t OJ ac.:cnt-rcquc~tcd not:f.cat:on.:m:t Client: PASI Kansas Project: 2075996 Site: None Matrix: Water Collected: 11/08/07 %Moisture: Recciyed: nia Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 11/09/07 {;nits Reporting Limit Prep. Reg. Analysis Limit 1ng/L 5.00 15-Nov-07 15-Nov-07 13:22 TAE ll/16/21)1)71 0:42:1)1 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47270

Inorganics Quality Control Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 ace Ana/yfical New Or/eafls Laboratory LCS LCS LCS MS Sample Project: 2075996 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 MS MSD MS MSD MSD DL"P QC Limits Max Qu Parameter Batch Blank ARL L"nits Spike Found %Rcc Spike Found Found Found %Rcc %Rcc RPD RPD LCS MS/MSD RPD Silic8 94226 :sro 1.00 n1g/L 10 10.76 108 10 30.71 38.68 11 denote iS ncm*er:y oubide of QC limib. l\\""0 denotesl"iotDeteded at or abqvethe adju:ded :reporting1imit or PQL. 1\\JSll\\JSD RPD i:s calculated "lia S\\Y-846 ru]e:s on the b~iiS of iSJlil.red ~Sample concentrntion:s rather than iSJlil'e recoYerleiS. 80 2 90 11075 125 20 Dl ll/16/21)1)71 0:42:1)3 LrJui~;anaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-1)421)2 ES. Dept f?{.!Jglkultlmd bm:ig11 SfJil Peu,it-S-47271)

ace Ana/yfical New Or/eafls Laboratory Qualifier Qualifier Description Qualifier Summary Project: 2075996 Pace Analytical Services, Inc. 1000 Riverbend Blvd. Suite F St. Rose, LA 70087 Phone; 504.469.0333 Fax; 504.469.0555 LELAP # 02006 Dl The imalysis "'VI.' as perfonned at 8 dilution due to the high ru1Etlyte concenu*ation. ll/16/21)1)71 0:42:1)(1 LrJui~ianaDeJJt. r?f'En~itrmmental Quali{v (LELAP)- 02()1)6 LrJui\\iana DeJJt. rd'llealtJJ 01d llrJ.\\jJitaJ..,.j DdnkbJg 1filzte1 - L!J 050004 A 1kaJ1.~a..,. Dept rd' En~~~ rJJJJIIeJJtol Quality-L!J 050004 Flmida Dept. rd'llerdtll (NEL!JC) E87595 Km1... a... Dept rd'llealtlJ En~i1rmmental-E-11)266 PeJJJI!*Yl~m*ia DEP tNELAC) 68-04202 ES. Dept r?{.!Jglkultlmd bm:ign SrJil Peunit-S-47270

APPENDIX D PUMPING TEST ANALYSIS CALCULATIONS

Average T & s Values Calculated from Distance vs. Drawdown Plots Test Elapsed Time 24 hours 48 hours 72hours Avera!e Test Elapsed Time 24 hours 48 hours 72hours Avera!e Overall Average= Test Well TW-01 Transmissivity (!pd/ft) 466,000 464,900 462,500 464,467 Test Well TW-01 Transmissivity (!pd/ft) 426,200 429,500 436,000 430,567 447,517 Line of Wells Parallel to River Storage Test Elapsed (unitless) Time 0.155 24 hours 0.215 48 hours 0.262 72hours 0.211 Avera!e Line of Wells Perpend icu Ia r to River Storage (unitless) 0.118 0.152 0.169 0.146 0.179 Test Elapsed Time 24 hours 48 hours 72hours Avera!e Overall Average=

  • storativity values not induded in average as they are artificially high.

CalwlatiOils.xlsAverage DvsD 6/11/2008 Test Well TW-02 Transmissivity (!pd/ft) 363,900 372,400 375,500 370,600 Test Well TW-02 Transmissivity (!pd/ft) 426,100 431,000 434,000 430,367 400,483 Storage (unitless) 0.155 0.282 0.417* 0.219 Storage (unitless) 0.190 0.338 0.482* 0.264 0.241 Bums & McDonnell

TW-01 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level C]) ~ 0 Perpendicular to River Ill 1111,~ ~s I= 1 !~7 ft I" ~ ~ 5 r II Ill "0 / Da.te. o.1 test start: I 1/8!2. 007 ~ ~ Pumping period = 1 Day 0 Test l(velll~adius = p ~ 10 1 10 Pumping rare, Q = 1,594 gpm T = 52RQ = 426,200 gpd/ft L'.s s = 0.3Tt = 0.118 r' 0 1111 II Ill I I Ill 100 1000 10000 Distance from Pumping Well (feet) 24 Hours TW01 24 Dist vs Ddn Corr.grf6/10/08

w

~ c ~ "0 5: ~ 0 Parallel to River 0 1111 ~***** ~s ~ 1.lal1 ft/ s I./ I II Ill I

II II III I 111 111,

_j Test ~ell R~dius = 1 ft Date of test start: 11/8/2007 Pumping period = I Day Pumping rare, Q = 1,594 gpm T = 52RQ = 466,000 gpd/ft L'.s s=O.JTt = o.1ss 2 r 0 10 -ttl t 111 11111 II I I 1 10 100 1000 10000 Distance from Pumping Well (feet) Distance vs. Drawdown Test Well TW-01 72-hour Pumping Test Callaway Plant

TW-01 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level C]) ~ c::: 0 Perpendicular to River II _ - I II llll u~ ~s I= 1 !~6 n I. ~


+---++-.-

~ 5 --111 '*I I' ! I I 0 "0 +-- Date oftest start: I 1/8/2007 Pumping period = 2 Days ~ / 0 Test l(velll~adius = p ~ 10 1 10 Pumping rare, Q = 1,594 gpm T = 5280 = 429,500 gpdlft t.s s=O.JTt = o.I52 r' 0 1111 II Ill I I Ill 100 1000 10000 Distance from Pumping Well (feet) 48 Hours TW01 48 Dist vs Ddn Corr.grf6/10/08

w

~ c::: ~ "0 ~ ~ 0 Parallel to River 0 / 5 I I,- II Ill I I I I II III I 111 1111 _j Test ~ell R~dius = 1 ft Date of test start: 11/8/2007 Pumping period = 2 Days Pumping rare, Q = 1,594 gpm T = 5280 = 464,900 gpd/ft t.s s = 0.3Tt = 0.215 2 r 0 10 -ttl t lll l l ll[ II I I 1 10 100 1000 10000 Distance from Pumping Well (feet) Distance vs. Drawdown Test Well TW-01 72-hour Pumping Test Callaway Plant

TW-01 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level C]) ~ c::: 0 Perpendicular to River I,,, 1.-- I II 1111 ~~ ~sl= 11.~3 tt, I. ~ / I ~ 5 /1 II Ill e Da.te. ~.{test s~art: 1,118!2. 0;;-- ~ Pumpmg perwd = :J Days 0 Test l(vellj~adius = p ~ 10 1 10 Pumping rare, Q = 1,594 gpm T = 52RQ = 436,000 gpd/ft L'.s s=O.JTt = o.1w r' 0 1111 II Ill I I Ill 100 1000 10000 Distance from Pumping Well (feet) 72 Hours TW01 Dist vs Ddn Corr.g rf 6/10/08

w

~ c::: ~ "0 5: ~ 0 Parallel to River 0 ~sl= 1la2 tt 5 I / /1 / ll Ill I I IIIII II I 1111111 _j Test ~ell R~dius = 1 ft Date of test start: 11/8/2007 Pumping period = 3 Days Pumping rare, Q = 1,594 gpm T = 52RQ = 462,500 gpd/ft L'.s s = 0.3Tt = 0.262 r' I 10 I I II lif t' llllllll II 11 11 1 10 100 1000 10000 Distance from Pumping Well (feet) Distance vs. Drawdown Test Well TW-01 72-hour Pumping Test Callaway Plant

C]) ~ c::: ~ "0 ~ 0 0 TW-02 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level Perpendicular to River Parallel to River I II 1111~ 1 0 1111 tW 115 ~ ~sl= 2. lo.s ~ 2l1la ft, ~ c::: 5 +-+ 3: 0 "0 5 8Lllll.lllll 1111111 10 1 / Test l(veiiiFRadius = M ft 10 Date of test start: 11/141200 7 Pumping period = 1 Day Pumping rate, Q = I, 918 gpm T = 5280 = 426,100 gpd/ft ~s s = 0.3 Tt = 0.190 r' 0 I I I I I II I I 100 1000 10000 Distance from Pumping Well (feet) 3: ~ 0 Date of test start: 11/14/2007 Pumping period = I Day Pumping rare, Q = I, 918 gpm J"~st ~ell R~dius = 1 ft I T = 5280 = 363,900 gpd/ft t.s s=0.3Tt = o.Jss 1 10 100 1000 ro' i~ I I II F t HTI IIII I I - 10 10000 Distance from Pumping Well (feet) 24 Hour Distance vs. Drawdown Test Well TW-02 72-hour Pumping Test Callaway Plant TW02 Dist vs Ddn.grf 6/10/08

C]) ~ c::: 0 ~ 5 l 0 10 ~s / Test 1 1 F=2 / 'Veil TW-02 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level Perpendicular to River Parallel to River ~,~ ~ ~* ~5 ft ~ / +- _j_ Date of"test start: 11/1412007 Pump inK period = 2 Days Pumping rate, Q = 1, 918 gpm ~adius = ft T = 5280 = 431,000 gpd/ft L'.s s = 0.3Tt = O.JJg r 0 I I II I I Ill 10 100 1000 10000

m

~ c::: ~ "'0 ~ ~ 0 0 IJ 5 ~~s1=1tL1 11 I.1111) 1111111 / Date of test start: 11/14/2007 Pumping period = 2 Days Pumping rare, Q = 1, 918 gpm T~st ~ell R~dius = 1 ft I T = 5280 = 372,400 gpd/ft L'.s S = 0.3Tt = 0.2g2 1 10 100 1000 ro' i~ I I II F t HTIIIII I I - 10 10000 Distance from Pumping Well (feet) Distance from Pumping Well (feet) 48 Hour Distance vs. Drawdown Test Well TW-02 72-hour Pumping Test Callaway Plant TW02 Dist vs Ddn.grf 6/10/08

C]) ~ c::: 0 ~ 5 l 0 10 1 ~s / / Test I F2 / (Veil TW-02 Distance vs. Drawdown Analysis Drawdown Corrected for Drop in River Level Perpendicular to River Parallel toR 1ver / l / lvr-/. p3 ft, ~ I _j_ / f-Date of"test start: II /I412007 Pump inK period = 3 Days Pumping rate, Q = I, 9 I 8 gpm ~adius = ft T = 5280 = 434,000 gpd/ft ils s = o.JTt = o.4g2 2 ro I I II I I Ill 10 100 1000 10000

m

~ c::: ~ "0 ~ ~ 0 0 .*~ L'-.sl = ~-toy 5 I I I I Ill I I I III II / Date of test start: JI/I4/2007 Pumping period = 3 Days Pumping rare, Q = 1, 918 gpm Test ~ell R~dius = 1 ft I T = 5280 = 375,500 gpd/ft. t.s s = 0.3Tt = 0.417 2 r 0 1 0 --H-t-t H-rTTTTT -i-1 10 100 1000 10000 Distance from Pumping Well (feet) Distance from Pumping Well (feet) 72 Hours Distance vs. Drawdown Test Well TW-02 72-hour Pumping Test Callaway Plant TW02 Dist vs Ddn.grf 6/10/08

Well No. TW-01 FMW-07 0801-01 0801-02 0801-03 0801-04 0801-05 0801-06 0801-81 0801-82 Averages 0801-01 to 06 0801-01' 05, 06 0801-02, 03 Calculations.xlsTime Ddn Summary 6/17/2008 Time vs. Drawdown Analysis Summary TW-01 Site lW-02 Site Transmissivity (gpd/ft) Storativity Well No. Transmissivity (gpd/ft) Storativity 437,300 0.00141 TW-02 754,000 0.00047 301,900 0.00542 FMW-11 409,400 0.00066 437,300 0.00141 0802-01 754,000 0.00047 403,600 0.01257 0802-02 611,000 0.00025 596,400 0.04075 0802-03 490,200 0.00073 821,600 0.00274 0802-04 1,008,000 0.00054 503,100 0.01029 0802-05 448,000 0.00074 527,800 0.00969 0802-06 485,400 0.00139 324,500 0.00005 0802-81 198,200 0.00055 406,900 0.00001 0802-82 303,200 0.00038 Averages 548,300 0.0129 0802-01 to 06 632,800 0.0007 489,400 0.0071 0802-01 ' 05, 06 562,500 0.0009 500,000 0.0267 0802-02,03 550,600 0.0005 Burns & McDonnell

10 'I 'I I 'I TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-01.agt Date: 02/06/08 Time: 16:31:37 --/-- ~~ PROJECT INFORMATION ~~~~- Company* Burns & McDonnell ¢:::: - -""',..n Client: Ameren Cor~oration +-' r"' c + Project: 46691 CD + E

1. r-Location: Callawa~ Count~. Missouri CD

(.) Test Well: TW-01 m

c.

Test Date: November 8, 2007 .!Q 0 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 4.373E+5 gal/day/ft 0.1 ,I ,I I ,I s = 0.001405 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy=0.4185 11 = 0.03 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 - OB01-01 0 44

10 'I 'I I 'I

  • ~

TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-02.agt Date: 02/06/08 Time: 16:33:23 ,.......-,,_,~-----

1. r-

// ~ PROJECT INFORMATION Company* Burns & McDonnell ¢:: / Client: Ameren Cor~oration +-' c +17 Project: 46691 Q) E +: 0.1 r- +-/ Location: Callawa~ Count~. Missouri Q) +! u +: Test Well: TW-01 I / ro

a.

I / Test Date: November 8, 2007 .!!2 0 + / I I SOLUTION 0.01 I I I I I Aquifer Model: Unconfined I I Solution Method: Neuman I I I T = 4.036E+__§ gal/day/ft I 0.001 ,I I ,I I ,I s = 0.01257 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.5582 11 = 0.1 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 - OB01-02 90 0

10 'I 'I I 'I TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-03.agt ~ - - -~ Date: 02/06/08 Time: 16:35:07 1 .#._t:/ PROJECT INFORMATION / Company* Burns & McDonnell ¢::: - 0.1 b-F Client: Ameren Cor~oration +-' -= c Project: 46691 Q) E Location: Callawa~ Count~. Missouri Q) ,3"" / (.) .r*/; / Test Well: TW-01 rn / :c-IJ / o._ 0.01 ~ / Test Date: November 8, 2007 .!Q 0 I I I I I I I SOLUTION I I 0.001 I f-I Aquifer Model: Unconfined I I Solution Method: Neuman .t::, /\\ I I I T = 5.964E+_§ gal/day/ft 1.0E-4 ,/ I ,/ I ,/ s = 0.04075 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.05178 11 = 0.6 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 " OB01-03 180 0

1 'I 'I ~ --"~ ---,~ TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-04.agt ~"'*'~" ~'%§&-. Date: 02/06/08 Time: 16:38:46 ,f'~' ,F 0.1 ?' r- ~' -= (/ PROJECT INFORMATION ,fl {f ll Company* Burns & McDonnell ¢::: - ~~ Client: Ameren Corporation +-' c .~ ; Q) Project: 46691 E 0.01 r- <;-/ Location: Callaway County, Missouri Q) (.) I Test Well: TW-01 rn o_

  • ) :

Test Date: November 8, 2007 .!Q I 0 I I I SOLUTION 0.001 I I I Aquifer Model: Unconfined I I Solution Method: Neuman I I T = 8.216E+5 gal/day/ft ,/ I ,/ I ,/ s = 0.002744 1.0E-4 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.1296 11 = 0.4 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 OB01-04 362 0

10 'I 'I I 'I

  • ~

TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-05.agt Date: 02/06/08 Time: 16:39:07 ~-----

1. r-r-~~~

-= /.l PROJECT INFORMATION 6' Company* Burns & McDonnell ¢:: ./ Client: Ameren Corporation +-' i' c {f Project: 46691 Q) r/!7 E 0.1 r- .J.:t~/ Location: Callawa~ Count~. Missouri Q) ~r! u Test Well: TW-01 ro c / a_ G ! Test Date: November 8, 2007 .!!2 (;- ! 0

)

SOLUTION 0.01 r I I "C Aquifer Model: Unconfined I I Solution Method: Neuman I I I I T = 5.031 E+_§ gal/day/ft I 0.001 ,I I ,I I ,I s = 0.01029 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy=0.1783 11 = 0.1 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 ' ',-, 0801-05 0 134_33

¢:: - +-' c Q) E Q) u ro a. .!!2 0 10

1.

1:::-- 0.1 1:::-- 0.01 r 0.001 0.01 'I J ,I 0.1 Saturated Thickness: 80. ft ) 'I I 'I .~ = ~~ rt, ,l J' I; 0 I I I I I I I I /111

1.
10.

100. 1000. 1.0E+4 Time (min) AQUIFER DATA WELL DATA TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-06.agt Date: 02/06/08 Time: 16:39:23 PROJECT INFORMATION Company* Burns & McDonnell Client: Ameren Corporation Project: 46691 Location: Callaway County, Missouri Test Well: TW-01 Test Date: November 8, 2007 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 5.278E+5 gal/day/ft s = 0.009688 Sy = 0.1269 11 = 0.2 Pumping Wells Observation Wells I Well Name X (ft) Y (ft) II Well Name I X (ft) Y (ft) TW-01 0 0 OB01-06 0 223.25

10 'I 'I I 'I TW-01 CONSTANT RATE TEST Data Set: J:\\... \\FMW-07.agt Date: 02/06/08 Time: 16:31:20 '--'""'"~/ PROJECT INFORMATION Company* Burns & McDonnell ¢::::

  • ~

,+ Client: Ameren Corporation +-' c CD / I Project: 46691 E

1. r-Location: Callawa~ Count~. Missouri CD

(.) Test Well: TW-01 m

c.

Test Date: November 8, 2007 .!Q 0 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 3.019E+5 gal/day/ft 0.1 I ,I ,I I ,I s = 0.005421 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 2.749 11 = 0.06 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 - FMW-07 0 -18.75

10 I 'I "'I "'I TW-01 CONSTANT RATE TEST ~---- Data Set: J:\\... \\OB01-S1.agt Date: 02/06/08 Time: 16:52:36

1.

r- ~-- ---* PROJECT INFORMATION / / Company* Burns & McDonnell ¢:: - IF" Client: Ameren Corporation +-' ,./;: c Q) / i' Project: 46691 E 0.1 r- / f Location: Callawa~ Count~. Missouri Q) I fo u Test Well: TW-01 ro / f a_ I Test Date: November 8, 2007 .!!2 !/ 0 ~ / 0.01 / p SOLUTION i\\ ~~:::. ;-k, Aquifer Model: Unconfined Solution Method: Neuman I T = 3.245E+~ gal/day/ft I 0.001 , I ,I ,I ,I S = 5.136E-5 0.001 0.01 0.1 1.

10.

100. 1000. 1.0E+4 Sy = 0.004478 11 = 0.001 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 " OB01-S1 0 53.83

10 I 'I "'I "'I TW-01 CONSTANT RATE TEST Data Set: J:\\... \\OB01-S2.agt ,,.,;.'*~---~ Date: 02/06/08 Time: 16:53:43

1. r-

~i/c>"'.~ .. * "'-"'!>~ -:./ ~ PROJECT INFORMATION Company* Burns & McDonnell ¢:: - Client: Ameren Corporation +-' c Q) Project: 46691 E 0.1 r-Location: Callaway County, Missouri Q) u Test Well: TW-01 ro a_ Test Date: November 8, 2007 .!!2 0 0.01 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 4.069E+~ gal/day/ft 0.001 I ,I ,I ,I S = 1.449E-5 0.001 0.01 0.1 1.

10.

100. 1000. 1.0E+4 Sy = 0.00236 11 = 0.001 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-01 0 0 OB01-S2 100.08 0

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-01.agt Date: 02/07/08 Time: 14:25:29 ~IHII!I!!!:Hf!illl PROJECT INFORMATION ?~ Company* Burns & McDonnell ¢:::: .A Client: Ameren Corporation +-' ~ *"+ c CD Project: 46691 E

1.

I Location: Callawa~ Count~. Missouri CD r-(.) Test Well: TW-02 m

c.

Test Date: November 14, 2007 .!Q 0 I./ SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 7.54E+5 gal/day/ft 0.1 ,I ,I I ,I s = 0.000466 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.2015 11 = 0.001 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 - OB02-01 0 45.67

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-02.agt Date: 02/07/08 Time: 14:26:00 ---=- PROJECT INFORMATION ~m_'_ iiiiliU 1 II Company* Burns & McDonnell ¢:::: Client: Ameren Corporation +-' I c /0 CD

J Project: 46691 E
1. r-Location: Callawa~ Count~. Missouri CD D

(.) Test Well: TW-02 m

c.

Test Date: November 14, 2007 .!Q 0 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 6.11 E+5 gal/day/ft 0.1 ,I ,I I ,I s = 0.0002456 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.31 11 = 0.004 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name j X (ft) I y (ft) I TW-02 0 0 = OB02-02 89.33 0

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-03.agt Date: 02/07/08 Time: 15:42:56 ___...... ~ ZA~ - * *#~ PROJECT INFORMATION ~

1.

Company* Burns & McDonnell ¢::: ~ / Client: Ameren Cor~oration +-' c / Project: 46691 Q) E Location: Callawa~ Count~. Missouri Q) / (,) Test Well: TW-02 ro /; 0.. Test Date: November 14, 2007 .!Q 0 0.1 /' r-SOLUTION /.:. I : Aquifer Model: Unconfined I I Solution Method: Neuman I I I I I T = 4.902E+5 gal/day/ft I ,I I ,I s = 0.0007276 0.01 I ,I 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 1.253 11 = 0.06 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 OB02-03 177.83 0

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-04.agt Date: 02/07/08 Time: 15:43:09 1 ~ -*ot'"*-==~~ *- ~-~-=--- -~ // PROJECT INFORMATION 'l ./ / / Company* Burns & McDonnell ¢::: 0.1 I I Client: Ameren Cor~oration +-' b-i -= c / Project: 46691 Q) E / Location: Callawa~ Count~. Missouri Q) / (.) Test Well: TW-02 rn a_ 0.01 Test Date: November 14, 2007 .!Q 0 I I I I SOLUTION I I I 0.001 f-I I Aquifer Model: Unconfined I I Solution Method: Neuman I I I T = 1.008E+6 gal/day/ft I 1.0E-4 I ,I ,I I ,I s = 0.0005443 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.06939 11 = 0.03 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 OB02-04 358.75 0

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-05.agt Date: 02/07/08 Time: 15:43:23 ~ ~a :;n:ases:£SJ*t:liD

  1. fo"'~

PROJECT INFORMATION

1.

r

f Company* Burns & McDonnell

¢::: f Client: Ameren Cor~oration +-' / 6 c /' Project: 46691 Q) E Location: Callawa~ Count~. Missouri Q) (,) / Test Well: TW-02 ro I 0.. Test Date: November 14, 2007 .!Q 0 0.1 r-SOLUTION Aquifer Model: Unconfined I I I Solution Method: Neuman I I I I T = 4.48E+5 gal/day/ft I I 0.01 I ,I ,I I ,I s = 0.0007386 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 1.388 11 = 0.03 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 - OB02-05 0 100.17

10 'I 'I I 'I

  • ~

TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-06.agt Date: 02/07/08 Time: 15:43:38 ~~ -,-'J ----- ~=< -til

1. r-

/:fo PROJECT INFORMATION )'" .t Company* Burns & McDonnell ¢:: oo / ::J Client: Ameren Corporation +-' // [_ c Q) Project: 46691 E } 0.1 r- /

J Location: Callaway County, Missouri Q) u Test Well: TW-02 ro t

a_ Test Date: November 14, 2007 .!!2 0 /- I SOLUTION 0.01 I I I Aquifer Model: Unconfined -I I I Solution Method: Neuman I I I T = 4.854E+5 gal/day/ft I I ,I ,I I ,I s = 0.001388 0.001 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 0.3069 11 = 0.06 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 = OB02-06 0 150.17

10 I 'I "'I "'I TW-02 CONSTANT RATE TEST / Data Set: J:\\... \\OB02-S1.agt /' - /.. Date: 02/07/08 Time: 15:43:53 r-

1. r-PROJECT INFORMATION Company* Burns & McDonnell

¢:: ~* Client: Ameren Corporation +-' ~ c ff Q) l Project: 46691 E 0.1 r-i Location: Callaway County, Missouri Q) u /.!::. Test Well: TW-02 ro

a.

/L. Test Date: November 14, 2007 Ill 0 (' ll,.

j.

SOLUTION 0.01 I I Aquifer Model: Unconfined I /!::.. I Solution Method: Neuman I I I I T = 1.982E+5 gal/day/ft I,, 0.001 I,' ,I ,I ,I s = 0.000545 0.001 0.01 0.1 1.

10.

100. 1000. 1.0E+4 Sy = 0.5037 11 = 0.01 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 " OB02-S1 0 55.33

10 I 'I "'I "'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\OB02-S2.agt Date: 02/07/08 Time: 15:44:55 1 .. ~~~

  1. <J.>P PROJECT INFORMATION

.#1'4 //..~ § Company* Burns & McDonnell ¢::: ll 0.1 b-Client: Ameren Cor~oration +-' -= c Project: 46691 Q) /? E ,-;;o Q) <? Location: Callawa~ Count~. Missouri (.)

' '?;;.

Test Well: TW-02 rn k-'

a.

0.01 Test Date: November 14, 2007 .!Q ,1 "-" 0 /{: "}

  • <~

SOLUTION I 0.001 f-I Aquifer Model: Unconfined I

  • I Solution Method: Neuman I

I I I T = 3.032E+5 gal/day/ft I 1.0E-4 I / ,I ,I ,I s = 0.0003777 0.001 0.01 0.1 1.

10.

100. 1000. 1.0E+4 Sy=0.1898 11 = 0.01 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 OB02-S2 99.5 0

10 'I 'I I 'I TW-02 CONSTANT RATE TEST Data Set: J:\\... \\FMW-11.agt Date: 02/07/08 Time: 15:46:51 ~IIIIII'IH+++tHIHIII-ltl-+t++fltftiiH+/-tJtft' ""'""' -- iUL PROJECT INFORMATION Company* Burns & McDonnell ¢:::: ,,;~>_......, +~/ Client: Ameren Cor~oration +-' c 'f* / Project: 46691 CD / E 7 / Location: Callawa~ Count~. Missouri CD (.) ( Test Well: TW-02 m 1//

c.

Test Date: November 14, 2007 .!Q 0 SOLUTION Aquifer Model: Unconfined Solution Method: Neuman T = 4.094E+5 gal/day/ft 1 ,I ,I I ,I s = 0.0006612 0.01 0.1

1.
10.

100. 1000. 1.0E+4 Sy = 1730.2 11 = 0.001 Time (min) AQUIFER DATA Saturated Thickness: 80. ft WELL DATA Pumping Wells Observation Wells I Well Name I X (ft) I y (ft) II Well Name I X (ft) I y (ft) I TW-02 0 0 - FMW-11 0 -13.83

APPENDIX E PROJECTED COLLECTOR WELL YIELD ESTIMATE

Horizontal Collector Well Yield-Site 1 The yicltl of a horizontal collector well is a function of design (number and length of laterals), aquifer hydnmlics (n*ansmissivity, storativity, saturated thickness and areal extent) and recharge. Based upon tbe recent hydrogeological investigation conducted, sites along the Missouri River near Calloway, Missouri would be favorable: for development using a horizontal collector well. Evaluation of the aquifer testing indicates that the aquifer transmissivity near the test pumping well is in the range of 450,[){)0 gpd/ft (57" F'), with a saturated aquifer thickness of about 75 feet. The estimated yield of a horizontal collector well at the site was calculated using the following equation (Hantush and Papadopulos) and assumptions. where: Sc, Q K b r a l Scs 2: ['r c.:J2 ( _iL) Ln 2(1 - 27lKb ,,e cos 7t (2-. b -= Drawdown in collector well, ft - Yield of collector, gpd = Hydraulic Conductivity, gpd/fe """"'Saturated thickness of aquifer, ft = (2 (a-rc))/1 = Effective distance to a line of recharge, ft =Average length oflatera1s, ft = Radius of co Hector caisson, ft _; (2a - rc-1)/1 = Effective radius of each lateral, ft =Depth uflaleral below stalic water level, fl b 4i rw)) Using site-specific information and a variation of the above equation, the yields of a collector well at the test site was calculated using the following assumptions: Top of Aquifer Elevation Base of Aquifer Centerline of Laterals Tnside Diameter of Caisson Static Water Level (test, low conditions) Transmissivity Hydraulic Conductivity Radius ofLaterals Design distance to line source of recharge Average Lateral Length No. ofLatcrals 25 feet below grade 100 feet below grade 92 feet below grade 20 feet 20 feet below grade 450,000 gpd/ft (57 oF) 6,000 gpdltt2 (57 ° F) 0.5 ft 1000 fl (test conditions) 1200 ft ("'inter, low) 900FT (summer, low) 200ft 14 Calculated yields lUlder three conditions (Test; Low, Winter-45 n F and Summer, Low-65 ° F) are shown in Figme 1 (attached). As shown on Figure 1, yields between 25 and 40 MGD should b~ expected at the site frotn a horizontal collector welL

0 ~ ~ ~ - -a~ 10 20 Q} ~ c::: 30 ~ 0 "0 ~ 40 0 "0 Q} 13 50 Q} "5' a_ 60 I 70 80 f:.::" "-~ ~ ~ FIGURE 1 Projected Collector Well Drawdown Site 1 - Ameren, Callaway, MO ~ * -- ~ ~ ~

  • ---~....

~ ~ "" \\ Maximum Recommended Drawdown ' \\ I Centerline of laterals I I PRELIMINARY I ~ \\ \\ ~. 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 Pumping Rate (gpm) -+- Summer, Low ........_ Test Conditions Winter, Low Ameren-CallowayMO-sije1 Collector Well Yield-12-20-07-BMc.xls 1/9/2008 DRAFT

TW-01 Distance to Recharge Boundary Calculations Q-pumpi11g oate gpm Well No. o - dista11ce 1oom pumpi11g well to obs well 0801-01 a - dista11ce to effective recharge 0801-02 s -observed doawdow11 ill obs well 0801-03 0801-04 T,- calculated tra11smissivity>Mth above parameters 0801-05 0801-06 Rorabaugh (1956) Parallel Analysis using 0801.02 o-1594 gpm a-

    • =

90 1eet 4a 2

s-2.191 1eet 4a2+1* 2 adjvst *a* 1JI1til "T" "matches tcrget T Sqot(4a2+o 2)

Tc;;;;; 450. 156 gpdl1t Sqot(4a2+o 2)1o TaogetT-450.000 gp dl1t log(Sqot(4a2+o 2)1r) Rorabaugh (1956) Parallel Analysis using 0801.03 o-1594 gpm a-I';;;;;; 180 1eet 4a2

s-1.604 1eet 4a2+1*2 adjvst *a* 1JI1tiJ "T" "matches tcrget T Sqot(4a2+o 2) lc=

450.039 gpdl1t Sqot(4a2+o 2)1o TaogetT-450.000 gp dl1t log(Sqot(4a2+o 2)1r) Rorabaugh (1956) Parallel Analysis using 0801.04 o-1594 gpm a-

    • =

362 1eet 4a2

s-0.888 1eet 4a2+1*2 adjvst "a" 1JI1tiJ "T" "matches tcrget T Sqot(4a2+o 2)

Tc;;;;; 450.559 gpdl1t Sqot(4a2+o 2)1o TaogetT-450.000 gp dl1t log(Sqot(4a2+o 2)1r) Rorabaugh (1956) Perpendicular Analysis using 0801.01 & 0801.05 ai 465 adjvst a; until it matct/es ai 44 1eet 134.33 1eet s, 2.985 1eet s, 1.995 1eet a.- l Dis! 44.00 90.00 180.00 362.00 134.33 223.25 668 1eet 1784896 8100 1792996 1339.028 14.878 1.173 643 1eet 1653796 32400 1686196 1298.536 7.214 0.858 510 1eet 1040400 131044 1171444 1082.333 2.990 0.476 k-s1/s2 1.50 (0.5.(2a,+o 2)' x (o 11r,'))- (o 112) Rorabaugh (1956) Perpendicular Analysis using 0801.01 & 0801.06 ai 501 feet adjvst a; untilit matct/es ai 44 1eet 223.25 1eet s, 2.985 1eet s, 1.604 1eet a.- l k-s1/s2 1.86 (0.5.(2a,+o 2)' x (o 11r,'))- (o 112) Rorabaugh (1956) Perpendicular Analysis using 0801.05 & 0801.06 ai 565 feet adjvst a; until it matct/es ai 11 134.33 1eet aj-s, s, k-223.25 1eet 1.995 1eet 1.604 1eet s11s2 1.24 CoJ.h:;ul.:dions.;.l5oJ. Oi51 TW-C1 611112CC8 Average Parallel a= Average Perpendicular a = Average a= 607 510 559 Ddn 2.985 2.191 1.604 0.888 1.995 1.604 (2a,+r2) (2a1+r2)' (o 11o,') o112 (2a,+r2) (2a,+r2)' (o 11o,') o112 1064.33 33824.740 0.02878683 22 465 1eet 1225.25 558600.697 0.00187248 22 501 1eet 1353.25 7846.938 0.16100042 67.165 565 1eet Burns & McDonnell

TW-02 Distance to Recharge Boundary Calculations Q-pumpi11g oate gpm o - dista11ce 1oom pumpi11g well to obs well a - dista11ce to effective recharge s -observed doawdow11 ill obs well T,- calculated tra11smissivity>Mth above parameters Rorabaugh (1956) Parallel Analysis using 0802.02 Q-1906 gpm o - 89.33 1eet

s-2.869 1eet adjvst *a* 1JI1til "T" "matches tcrget T T,-

400,163 gpdl1t Tao get T-400.000 gpdl1t Rorabaugh (1956) Parallel Analysis using 0802.03 Q-1906 gpm o - 177.83 1eet

s-1.731 1eet adjvst *a* 1JI1tiJ "T" "matches tcrget T T, -

400, 178 gpdl1t Tao get T-400.000 gpdl1t Rorabaugh (1956) Parallel Analysis using 0802.04 Q-1906 gpm o-358.75 1eet 1.118 1eet adjvst "a" 1JI1tiJ "T" "matches tcrget T T,- 400,003 gpdl1t Tao get T-400,000 gpdl1t Well No. 0802-01 0802-02 0802-03 0802-04 0802-05 0802-06 a-4a 2 4a2+1* 2 Sqot(4a2+o 2) Sqot(4a2+o 2)1o log(Sqot(4a2+o 2)1r) a-4a2 4a2+1*2 Sqot(4a2+o 2) Sqot(4a2+o 2)1o log(Sqot(4a2+o 2)1r) a-4a2 4a2+1*2 Sqot(4a2+o 2) Sqot(4a2+o 2)1o log(Sqot(4a2+o 2)1r) Rorabaugh (1956) Perpendicular Analysis using 0802.01 & 0802.05 ai 369 adjvst a; until it matct/es ai 45.67 1eet 100.17 1eet s, 3.008 1eet s, 2.249 1eet a.- l Dis! 45.67 89.33 177.83 358.75 100.17 150.17 617 1eet 1522756 7979.8489 1530735.84 9 1237.229 13.850 1.141 425 1eet 722500 31623.5089 754123.5089 868.403 4.883 0.689 466 1eet 868624 128701. 5625 997 325. 5625 998.662 2.784 0.445 k-s1/s2 1.34 (0.5.(2a,+o 2)' x (o 11r,'))- (o 112) Rorabaugh (1956) Perpendicular Analysis using 0802.01 & 0802.06 ai 266 feet adjvst a; until it matct/es ai 45.67 1eet 150.17 1eet s, 3.008 1eet s, 1.793 1eet a.- l k-s1/s2 1.68 (0.5.(2a,+o 2)' x (o 11r,'))- (o 112) Rorabaugh (1956) Perpendicular Analysis using 0802.05 & 0802.06 ai 167 feet adjvst a; until it matct/es ai 11 100.17 1eet aj-s, s, k-150.17 1eet 2.249 1eet 1.793 1eet s11s2 1.25 CoJ.h:;ul.:dions.;.l5oJ. Oi51 TW-C*2 611112CC8 Average Parallel a= Average Perpendicular a = Average a= 503 267 385 Ddn 3.008 2.869 1.731 1.118 2.249 1.793 (2a,+r2) (2a1+r2)' (o 11o,') o112 (2a,+r2) (2a,+r2)' (o 11o,') o112 838.17 8126.583 0.09631141 22.835 369 1eet 682.17 56785.590 0.01018869 22.835 266 1eet 484.17 2332.668 0.18646645 50.085 167 1eet Burns & McDonnell

Fr=1.87a2S/Tt a= 1000 feet S= 0.178 T= 450000 gpdlft t = 24 days Pr= 85 % a (ft) 1 3 400 0.1184 0.0395 450 0.1498 0.0499 500 0.1849 0.0616 550 0.2238 0.0746 600 0.2663 0.0888 650 0.3125 0.1042 700 0.3624 0.1208 750 0.4161 0.1387 800 0.4734 0.1578 850 0.5344 0.1781 900 0.5991 0.1997 950 0.6676 0.2225 1000 0.7397 0.2466 1050 0.8155 0.2718 1100 0.8950 0.2983 1150 0.9782 0.3261 1200 1.0652 0.3551 1250 1.1558 0.3853 1300 1.2501 0.4167 1350 1.3481 0.4494 1400 1.4498 0.4833 Calculations.xlsTW-01 Recharge 6!1012008 TW-01 River Recharge Ratio Calculation 100 distance from pumped well to recharge boundary Coefficient of storage 90 Transmissivity time after pumping started percentage of pumped water delivered from recharge source after t days 80 t (days) 5 10 20 24 30 60 90 0.0237 0.0118 0.0059 0.0049 0.0039 0.0020 0.0013 70 0.0300 O.Di 50 0.0075 0.0062 0.0050 0.0025 0.0017 f-- 0.0370 0.0185 0.0092 0.0077 0.0062 0.0031 0.0021 z 0.0448 0.0224 0.0112 0.0093 0.0075 0.0037 0.0025 w 60 u 0.0533 0.0266 0.0133 0.0111 0.0089 0.0044 0.0030 cr 0.0625 0.0313 0.0156 0.0130 0.0104 0.0052 0.0035 w 0.0725 0.0362 0.0181 0.0151 0.0121 0.0060 0.0040 Q 50 0.0832 0.0416 0.0208 0.0173 0.0139 0.0069 0.0046 2: 0.0947 0.0473 0.0237 0.0197 0.0158 0.0079 0.0053 0.1069 0.0534 0.0267 0.0223 0.0178 0.0089 0.0059 0.1198 0.0599 0.0300 0.0250 0.0200 0.0100 0.0067 a..~ 0.1335 0.0668 0.0334 0.0278 0.0223 0.0111 0.0074 0.1479 0.0740 0.0370 0.0308 0.0247 0.0123 0.0082 30r\\ 0.1 0.2 0.3 0.4 0.5 0.1631 0.0816 0.0408 0.0340 0.0272 0.0136 0.0091 VALUE OF Ft 0.1790 0.0895 0.0448 0.0373 0.0298 0.0149 0.0099 FOR UPPER CURVE:. 0.1956 0.0978 0.0489 0.0408 0.0326 0.0163 0.0109 20 0.2130 0.1065 0.0533 0.0444 0.0355 0.0178 0.0118 0.2312 0.1156 0.0578 0.0482 0.0385 0.0193 0.0128 0.2500 0.1250 0.0625 0.0521 0.0417 0.0208 0.0139 10 0.2696 0.1348 0.0674 0.0562 0.0449 0.0225 0.0150 0.2900 0.1450 0.0725 0.0604 0.0483 0.0242 0.0161 0 0 I 2 3 4 5 Ft f Burns & McDonnell

Fr=1.87a2S/Tt a= 825 feet S= 0.208 T= 400000 gpdlft t = 23 days Pr= 85 % a (ft) 1 3 400 0.1556 0.0519 450 0.1969 0.0656 500 0.2431 0.0810 550 0.2942 0.0981 600 0.3501 0.1167 650 0.4108 0.1369 700 0.4765 0.1588 750 0.5470 0.1823 800 0.6223 0.2074 850 0.7026 0.2342 900 0.7876 0.2625 950 0.8776 0.2925 1000 0.9724 0.3241 1050 1.0721 0.3574 1100 1.1766 0.3922 1150 1.2860 0.4287 1200 1.4003 0.4668 1250 1.5194 0.5065 1300 1.6434 0.5478 1350 1.7722 0.5907 1400 1.9059 0.6353 Calculations.xlsTW-02 Recharge 6!1012008 TW-02 River Recharge Ratio Calculation 100 distance from pumped well to recharge boundary Coefficient of storage 90 Transmissivity time after pumping started percentage of pumped water delivered from recharge source after t days 80 t (days) 5 10 20 23 30 60 90 0.0311 0.0156 0.0078 0.0068 0.0052 0.0026 0.0017 70 0.0394 0.0497 0.0098 0.0086 0.0066 0.0033 0.0022 f-- 0.0486 0.0243 0.0122 0.0106 0.0081 0.0041 0.0027 z 0.0588 0.0294 0.0147 0.0128 0.0098 0.0049 0.0033 w 60 u 0.0700 0.0350 0.0175 0.0152 0.0117 0.0058 0.0039 cr 0.0822 0.0411 0.0205 0.0179 0.0137 0.0068 0.0046 w 0.0953 0.0476 0.0238 0.0207 0.0159 0.0079 0.0053 Q 50 0.1094 0.0547 0.0273 0.0238 0.0182 0.0091 0.0061 2: 0.1245 0.0622 0.0311 0.0271 0.0207 0.0104 0.0069 0.1405 0.0703 0.0351 0.0305 0.0234 0.0117 0.0078 0.1575 0.0788 0.0394 0.0342 0.0263 0.0131 0.0088 a..~ 0.1755 0.0878 0.0439 0.0382 0.0293 0.0146 0.0098 0.1945 0.0972 0.0486 0.0423 0.0324 0.0162 0.0108 30r\\ 0.1 0.2 0.3 0.4 0.5 0.2144 0.1072 0.0536 0.0466 0.0357 0.0179 0.0119 VALUE OF Ft 0.2353 0.1177 0.0588 0.0512 0.0392 0.0196 0.0131 FOR UPPER CURVE:. 0.2572 0.1286 0.0643 0.0559 0.0429 0.0214 0.0143 20 0.2801 0.1400 0.0700 0.0609 0.0467 0.0233 0.0156 0.3039 0.1519 0.0760 0.0661 0.0506 0.0253 0.0169 0.3287 0.1643 0.0822 0.0715 0.0548 0.0274 0.0183 10 0.3544 0.1772 0.0886 0.0771 0.0591 0.0295 0.0197 0.3812 0.1906 0.0953 0.0829 0.0635 0.0318 0.0212 0 0 f 2 3 4 5 Ft f Burns & McDonnell

Preliminary Lateral Design 25.2 MGD = 37.8 MGD = 17500 gpm = 26250 gpm = Screen Model= Johnson 12P Screen 00 = 12.68 inches Wire Width= 0.152 inches Design point is 40% retained for natural gravel pack 2340 tt31m 3509 tt31m Based on average of grain size analysis from the FMW-06 through FMW-10 samples IX 40% Retained Grain Size (FMW-07) = Average 40% Retained Grain Size= n 40% Retained Grain Size (FMW-07) = 2.17 mm 1.50 mm 1.02 mm Results in 0 100 inch slot size = = = Open Area= slot sizel(slot +wire width)= 39.7% 0.085 inches 0.059 inches 0.040 inches Inlet Area= 37.7 x 00 x OA = 189.70 sq inlft of screen No. of Laterals= 14 Lateral Screen Length = 1 90 feet Total Screen Length = 2660 feet Screen 50% plugged = 94.85 in2/ft 94.85 in2/ft x 2660 feet= 252296.8 in2 = Entrance Velocities 3509 tt31m I 2340 tt31m I Mechanical Capacity at Screen Size Open Area (inches) 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 CalwlatiOils.xlslateral Design 6/10/2008 0.062 0.116 0.165 0.208 0.248 0.283 0.315 0.345 0.372 0.397 1752.1 ft2 = 1752.1 ft2 = 2.00 fpm 1.34 fpm 2.0 feet per minute Feet of Screen Inlet Area 50% Plug No. of Laterals (in21ft) (in21ft) 12 14 29.51 14.75 2280 2660 55.59 27.79 2280 2660 78.80 39.40 2280 2660 99.59 49.80 2280 2660 118.33 59.16 2280 2660 135.29 67.65 2280 2660 150.73 75.37 2280 2660 164.84 82.42 2280 2660 177.78 88.89 2280 2660 189.70 94.85 2280 2660 1752.1 ft2 Mech Cap @ 2.0 fpm (MGD) No. of Laterals 6 8 5.0 5.9 9.5 11 1 13.4 15.7 17.0 19.8 20.2 23.5 23.1 26.9 25.7 30.0 28.1 32.8 30.3 35.4 32.4 37.7 Bums & McDonnell}}