Report ITAAC August 16, 2012

Overview Report ITAAC rely on a technical report to satisfy the acceptance criteria of the ITAAC Examples of Report ITAAC include:

- Equipment Qualification

  • Environmental Qualification
  • Functional Qualification
  • Seismic Qualification

- ASME

  • Piping/Component Design
  • Piping/Component As-Built
  • Weld NDE/hydrostatic tests 2

ASME Report ITAAC 3

  • Typically satisfied by the N-5 Code Data Report
  • N-5 Code Data Report can be defined as

- A document that certifies that [materials, design, fabrication, examination, testing, and inspection] of an item are in accordance with the requirements of ASME Section III

  • Example ITAAC from Appendix C of the VCS Unit 2 COL:

Piping System Construction Process & Documentation

[Note] - This is ASME Construction which is an all-inclusive term

  • Initial Design - Design Specification
  • Material Procurement - CMTRs/CofCs
  • Fabrication - Welding/Mechanical Data Sheets
  • Examination - NDE Reports
  • Testing - Pressure Test Reports
  • Inspection - ANI oversight
  • As-built reconciliation - Dimensional checks
  • Final Design Report - Design meets Design Specification
  • Certification and Stamping - The Code Data Report

N-5 Report Attributes

  • Represents an index to (as applicable):

- Design Specification

- CMTRs/CofCs

- Welding/Mechanical Data Sheets

- NDE Reports

- Pressure Test Reports

- ANI oversight

- As-built reconciliation

- Final Design Report

- Certification and Stamping - The Code Data Report 5

ASME ITAAC CLOSURE

  • Based on the contents and comprehensive nature of the Data Report process, the N-5 Data Report will serve as the basis for closure of these ASME-related ITAAC issues.

The Final Product - Data Report N-5 Form - The Index

The Final Product - Data Report Drawings - Page 1

The Final Product - Data Report Drawings - Page 2

The Final Product - Data Report Components

The Final Product - Data Report Subassemblies

The Final Product - Data Report Supports

The Final Product - Data Report Materials

The Final Product - Data Report Welds

The Final Product - Data Report Pressure Tests

The Final Product - Data Report N-5 Data Reports for Shop Assembly

The Final Product - Data Report Nameplate

The Final Product - Data Report Preservice Inspection

EQUIPMENT QUALIFICATION 19

EQ Report ITAAC

  • Satisfied by Equipment Qualification Data Package(s)

(EQDP) and Equipment Qualification Summary Report(s)

  • Appendix 3D - Attachment A of the AP1000 DCD contains a sample EQDP
  • Example ITAAC from Appendix C of the VCS Unit 2 COL:

20

EQDP & EQSR

  • EQ Data Package - Provides description of the overall qualification program for that component/commodity, and a summary of the type testing and analysis results.
  • EQ Summary Report - Summarizes the details of the qualification work performed
  • Together, the EQDP and EQSR provide all of the information required by AP1000 DCD Appendix 3D.
  • Together, the EQDP and EQSR for each component/commodity are the report that exists and concludes the equipment is qualified 21

EQDP Contents 1.

Specifications - Equipment identification and requirements 2.

Qualification Program - Description of overall program 3.

Qualification by Test - Test Plan and Summary of Results 4.

Qualification by Analysis - Analysis Methods and Results 5.

Qualification Program Conclusion 22

EQSR Contents 1.

Introduction 2.

Equipment to be Qualified - Equipment description, identification, performance specifications, qualification requirements (Seismic, DBA, QME-1, etc.), qualification program 3.

Type Testing Performed - General Description, Specific test names, descriptions, procedures, results and anomalies 4.

Analyses Performed - General Discussion, specific name and description of each analysis, its scope, methodology, and results 5.

Qualification Basis - Qualification Basis, statement of qualified lifetime/operating cycles 6.

Installation Requirements and Maintenance, Surveillance, and Replacement Program - Limitations on installation, and maintenance/surveillance/replacement requirements 7.

Summary and Conclusions 23