SB-0034 - Bechtel Response to Calculation C-CSS-099.20-054, Revision 0
ML12213A334
Person / Time
Site: Davis Besse 
Issue date: 07/27/2012
From:
Office of Information Services
To:
References
FOIA/PA-2012-0121
Download: ML12213A334 (1)


Text

SB-0034.

Calculation C-CSS-099.20-054, Revision 0:

Page 9: At the top of the page, equation y = Max (0, c-h)

Please explain how this is used in the calculation. Given that c is always less than h, the above equation will always return y = 0.

BECHTEL RESPONSE Please refer to Figure 1 below for a graphical explanation of the meaning of y. As can be seen, the variable y is always measured from the location of the neutral axis, which lies outside of the concrete cross section only when the compression force P is very large (i.e., for demands nearing the compressive capacity of the section). Therefore, for a section under the large compression demand shown in figure 1, the internal compressive force C is obtain by integrating the compressive stress between (c-h) and c.

El TC mC.

_Fle~xure... c-_A-----

Compression

- -4 Neutral axis Section Strains Total Strain Figure 1: Strains and demands for a section under large compression demand and moment

/