Discharge Monitoring Report for June 2012
ML12198A244
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 07/12/2012
From: John Carlin
Tennessee Valley Authority
To: Morgan C
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Pollution Control
References
TN0026450
Download: ML12198A244 (9)


Text

Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 July 12, 2012 Ms. Christina Morgan Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6 th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534

Dear Ms. Morgan:

TENNESSEE VALLEY AUTHORITY (TVA) - SEQUOYAH NUCLEAR PLANT (SQN) -

NPDES PERMIT NO. TN0026450 - DISCHARGE MONITORING REPORT (DMR) FOR JUNE 2012 Enclosed is the June 2012 Discharge Monitoring Report for Sequoyah Nuclear Plant.

There were no exceedances during the monitoring period.

In the Sequoyah Nuclear Plant Unit 2 Cycle 18 refueling outage of October 2012, TVA will replace the unit's four steam generators. During this large maintenance project, each of the steam generators will be cut free from existing piping, lifted out from the top of the concrete shield building, and maneuvered through the steel containment and internal structural concrete enclosures that house the steam generators. Cutting the temporary openings in the shield building and structural concrete enclosures using hydro-demolition will result in the generation of concrete rubble and hydro-demolition process waste water for disposal.

Up to 1.5 million gallons of water supplied by SQN's existing Fire Protection System (Hixson Utility District potable water) will be used for hydro-demolition over a 7 day period.

The hydro-demolition waste water will be filtered to 5 micron and the pH will be adjusted prior to flowing through SQN's normal waste water treatment process. As previously discussed with Bob Alexander with the Division, TVA does not believe the activity associated with replacing the steam generators will significantly change the nature or increase the quantity of pollutants discharged from permitted outfalls. SQN will continue to monitor Internal Monitoring Point 103 in accordance with NPDES permit TN0026450.

If you have any questions or need additional information, please contact Brad Love by email at bmlove@tva.gov or by phone at (423) 843-6714.

Ms. Christina Morgan Page 2 July 12, 2012 I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

4 1'r in Siequoyah PNresident Sequoyah Nuclear Plant Enclosures cc (Enclosures):

Chattanooga Environmental Field Office Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

PERMITIEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

___[(iNT__EROFFUCE OPS-5N--SQN)

SODDY - DAISY. T 337384._

FaIy TVA -SEQUOYAH NUCLEAR PLANT Location HAMI-LTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

TNO02645 IZI G

PERMIT NUMBER NUMBER MONITORING PERIOD I YEAR I MO DAY I YEAR MO From 1 12 1 0 os l ] To 1 12 06 o 1 30 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0004 F - FINAL DIFFUSER DISCHARGE EFFLUENT NO DISCHARGE LI]

NOTE: Read instructions before comoleting this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 41.0 04 0

30/30 RCORDR CENTIGRADE MEASUREMENT 00010 1

0 PERMIT Req. Mon.

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS TEMPERATURE, WATER DEG.

SAMPLE 30.4 4

0 30/30 MODELD CENTIGRADE MEASUREMENT 00010 Z

0 PERMIT 30.5 DEG.C.

CONTI CALCTD INSTREAM MONITORING REQUIREMENT DAILy MX NUOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE 2

04 0

30/30 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1

S PERMIT 3

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX NUOUS FLOW, IN CONDUIT OR THRU SAMPLE 1741 03 30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050 1

0 PERMIT Req. Mon.

MGD CONTI RCORDR EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS CHLORINE, TOTAL RESIDUAL SAMPLE 0.024 0.051 19 0

26/30 GRAB MEASUREMENT 50060 1

0 PERMIT ae*

0.1 0.1 MG/L FIVE PER CALCTD EFFLUENT GROSS REQUIREMENT MO AVG DAILY MAX WEEK TEMPERATURE - C, RATE OF SAMPLE 0

62 0

30 / 30 CALCTD CHANGE MEASUREMENT 82234 1

0 PERMIT 2

DEG

        • CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX C/HR NUOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my el direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the

\\

Vice President information, the infoi etion submitted is, to the best of my knowledlge and belief, b'us, accurate, Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIOWURE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFF 2 OR AUTHORIZED AGENT TYPED OR PRINTED TELEPHONE DATE 423 843-7001 12 07 1D1A YEAR O

A CODEI uIVION I

COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No dosed mode operation. Veliger monitoring data is included as an attachment. The following injections occurred: 1. Floguard MS6236 (max. calc. conc. was 0.059mg/L-limit 0.2mg/L) 2. Biodetergent 73551 (max. calc. conc. was 0.033mg/L-limit 2.Omg/L) 3. Spectrus CT1300 (max. calc. conc. was 0.037mg/L-limit 0.050mg/L)

EPA Form 3320-1 (REV 3199)

Plrevious editions may be used Page I of I

Mean# of NOTES: %

Mean # of W ater Sampl D t W ater Sample Date ZMIm3

% Settlers Temp. ('C) Sample Date Asiatic Temp. ('C)

LOCATION SUB LOCATION Gravid Asiatic COLLECTED BY Clams/m3 Clam 01/03/2012 14 100 26 01/03/2012 0

26 1-25-545 PKS 01/10/2012 01/17/2011 01/24/2012 01/31/2012 02/07/2012 02/14/2012 02/21/2012 02/28/2012 03/06/2012 03/13/2012 03/20/2012 03/27/2012 04/03/2012 04/10/2012 04/18/2012 May 2012 June 2012 0

0 0

0 0

0 0

0 0

0 0

1623 229 79 326 0

0 0

0 0

0 0

0 0

0 0

1.3 0

20 5

9 10 13 17.6 12 8.3 26.5 11.1 11.7 13 14.6 17.2 18 22 18.8 01/10/2011 01/17/2011 01/24/2012 01/31/2012 02/07/2012 02/14/2012 02/21/2012 02/28/2011 03/06/2012 03/13/2012 03/20/2012 03/27/2012 04/03/2012 04/10/2012 04/18/2012 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

9 10 13 17.6 12 8.3 26.5 11.1 11.7 13 14.6 17.2 18 22 18.8 RCW 1-ISV-24-1234 1-25-545 1-25-545 1-25-545 1-24-1234 1-25-545 1 -ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 WBE PB WDT CR BB WE CR WBE WBE WBE WBE WBE PB PB MJW No Samples Collected No Samples Collected

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

__L1PLN.ER. OFFICLE OPS-5N-SQ_N)_.

SODDY_- D.._.AISSY._NT

_37384_L-Facili

~

ýTVA--EQUOYAH NUCLEAR PLANT Location HAMItLON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

S TN002650 101 T I

PERMIT NUMBER I DISCHARGE NUMBER MONITORING PERIOD YEAR TIO DAY I

From 12 I06 1 01 1 To 1 12 I06 30 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-01 F - FINAL BIOMONITORING FOR OUTFALL 101 EFFLUENT NO DISCHARGE E]

NOTE: Read instructions before conmletino this form 004 ATTN: Brad Love PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7WAY CHR SAMPLE Monitoring CERIODAPHNIA MEASUREMENT Noti Reuired 23 TRP3B 1

0 PERMIT 4"3.**

42**

PERCENT SEMI COMPOS REQUIREMENT EFFLUENT GROSS MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE Monitoring 23 PIMEPHALES MEASUREMENT Not Required 23 TRP6C 1

0 PERMIT "***

43.2 PERCENT SEMI COMPOS REQUIREMENT EFFLUENT GROSS MIMINUM ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE lirection or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the resident information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 Sequoyah Site Vice President and complete. I am aware that there arm significant penalties for submitting false information, SIGkW6"T::i*E/OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA N

TYPED OR PRINTED OFFICERCOROAUTHORIZEDDAGENT AREAI NUMBER YEAR MO DAC COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Toxicity was not sampled in June 2012.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITrEE NAMEIADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

__INPTEROFFICE OPS-5N-SQN)

CC6 SODDY - DAISY, TN 37384 F.acii_ TWA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form DISCHARGE MONITORING REPORT (DMRJ (SUBR 01)

OMBI TN0026450

[

103 G F-FINAL PERMIT NUMBER DISCHARGE NUMBER LOW VOL. WASTE TREATMENT POND MONITORING PERIOD EFFLUENT Approved.

4o. 2040-0004 ATTN: Brad Love I YEAR I MO I DAY I IYEAR IMO I DAY

-- O C A G F 1 121 0s 1

o1 T--

NO DISCHARGE 0

3-rom TO NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING

. QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE 7

8 12 0

14 /30 GRAB MEASUREMENT 00400 1

0 PERMIT 6

9 SU THREE/

GRAB EFFLUENT GROSS REQUIREMENT MINIMUM MAXIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 5

6 19 0

2/30 GRAB MEASUREMENT 00530 1

0 PERMIT 30 100 MOIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MO AVG

-DAILY MX MONTH OIL AND GREASE SAMPLE

<6

<6 19 0

2/30 GRAB MEASUREMENT 00556 1

0 PERMIT 15 20 MGIL

'TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE 0.966 1.231 03 s*

0 30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050 1

0 PERMIT Req. Mon.

Req. Mon MGD SEE RCORDR EFFLUENT GROSS REQUIREMENT MO AG DAILY MX EFFLUENTALGROSS PERMIT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the resident information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 07 11 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIGNATURE OF PRINCIPAL EXECUTIVE TYPEDORPRINTED

_including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA INUMBER YEAR MO DAY TYPED OR PRINTED CODE_____NUMBER______YEAR_____MO___DAYOD I

CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

EPA Forrin 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMIrrTEE NAME/ADDRESS (Include Facility Namel1ocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

_LINTEROF COPSC-S4N-SQ MEE SODDY - DAISY, TN 37384..

Fa.c*i_

-- A - SEQUOYAH NUCLEAR PLANT Location HAMILTON CoUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

TN2645O

[

110G PERMIT NUMBER I

NUMBEýR MONITORING PERIOD SIMO IDAY YEAR IMO DAY From l12 106 01 ITo l12 1 06 301 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0004 F - FINAL RECYCLED COOLING WATER EFFLUENT NO DISCHARGE

[

NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 04 CENTIGRADE MEASUREMENT 04 00010 1

0 PERMIT REPORT DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS TEMPERATURE, WATER DEG.

SAMPLE 04 CENTIGRADE MEASUREMENT 04 00010 Z

0 PERMIT 30.5 DEG C CONTIN CALCTD INSTREAM MONITORING REQUIREMENT DAILY MX UOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE

    • 04 UPSTRM DEG.C MEASUREMENT 00016 1

0 PERMIT 5

DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT MX UOUS FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1

0 PERMIT Req. Mon.

MGD CONTIN RCORDR EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS CHLORINE, TOTAL RESIDUAL SAMPLE MEASUREMENT 19 50060.

1 0

PERMIT 0.1 0.1 MGIL Five per CALCTD EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILY MX Week TEMPERATURE - C, RATE OF SAMPLE CHANGE MEASUREMENT 04 82234 1

0 PERMIT 2

DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the eq St~c resident information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 07 11 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false infon.ation, SIGNATURE OF PRINCIPAL EXECUTIVE TYPEDORPRINTED

_including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED

_CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be us Page 1 of 1

PERMITIEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

.-.INTEROFFICE OPS-5N-SQN)

SODDY - DAISY_ TN. 37384._.

Facili__.: _.A -TSEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDESJ MAJOR DISCHARGE MONITORING REPORT (DMRJ (SUBR 01)

TN7702645077110 F

- FINAL PERMIT NUMBER DISCHARGE NUMBE RECYCLED COOLING WATER L

MONITORING PERIOD EFFLUENT Form Approved.

OMB No. 2040-0004 L ERLX

=MO=4I=DAY=I I.-EARIMQ4.IRDAY From 12106 1011 To1 121 6 130 ATTN: Brad Love NO DISCHARGE FM NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE 23 CERIODAPHNIA MEASUREMENT 23 TRP3B 1

0 0

PERMIT 43.2 PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE 23 PIMEPHALES MEASUREMENT TRP6C 1

0 0

PERMIT 43.2 PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the SI President information, the information submitted is, to the best of my knowledge and belief, thue, accurate, 423 843-7001 12 07 11 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIGI*,'IfOF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of I

PERMITTEE NAME/ADDRESS (Include Facility NamelLocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

-(IjNTEROFFICE OPS-N-SQN)

SODDY - DAISY_ TN 37384 Facii_

TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDESJ MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 7

71187G F - FINAL PERMIT NUMBER DISCHARGE NUMBER WASTEWATER & STORM WATER M NITORING PERIOD EFFLUENT Form Approved.

OMB No. 2040-0004 I YEARI MO I DAY I IYEARI MO I DAY I From 1 12 06 1 01 1 To 1 12 06 30 NO DISCHARGE [_ ] -.

NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING

[

QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE XI E

OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)

SAMPLE 19 MEASUREMENT 19 00300 1

0 PERMIT 2

  • MGOL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MINIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 19 MEASUREMENT 00530 1

0 PERMIT 100 MGRL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY MX WEEK SOLIDS, SETTLEABLE SAMPLE 25 MEASUREMENT 00545 1

0 PERMIT M******

e*******

-*ee**

1 MUL ONCE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1

0 PERMIT Req. Mon.

Req. Mon.

MGD

    • ONCE/

ESTIMA EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX BATCH SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accrdance with a system designed to assure that qualified personnel

/

John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the te ice President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 07 11 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIGNATURE OF PRINCIPAL EXECUTIVE TYPED O including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CD COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference ail attachments here)

During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of I