Found 4/5/12 Application for Amendment Regarding ADS Bypass Timer Acceptable for Review
ML12167A065
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 06/15/2012
From: Tam P
Plant Licensing Branch III
To: Kissinger P, Loeffler R
Northern States Power Co
Tam P
References
TAC ME8345
Download: ML12167A065 (1)


Text

Accession No. ML12167A065 From: Tam, Peter Sent: Friday, June 15, 2012 8:57 AM To: Loeffler, Richard A.; 'Kissinger, Peter W.'

Cc: Razzaque, Muhammad

Subject:

Monticello - Application for amendment dated 4/5/12 acceptable for review (TAC ME8345)

Rick, Pete:

The NRC staff found your application for amendment dated 4/5/12 regarding allowable value for the ADS bypass timer acceptable for review per the guidance of NRR Office Instruction LIC-109.

I apologize that I convey this message so late. The technical review branch had completed the acceptance much earlier but my communication fell thru the crack.

Peter S. Tam Senior Project Manager (for D. C. Cook and Monticello)

Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Tel. 301-415-1451