file:///Cl/...ef%20Request%20No.%20PRR-002%20for%20the%20Inservice%20Testing%20Program%20Third%2010-Year%20Interval.htm[6/12/2012 12:31:39 PM]

From: Chawla, Mahesh Sent: Monday, June 11, 2012 10:55 AM To: Alan I Hassoun Cc: McMurtray, Anthony; Billerbeck, John; Lingam, Siva; Boyle, Patrick

Subject:

Fermi 2 - ME8007 - Request for Additional Information - Relief Request No. PRR-002 for the Inservice Testing Program Third 10-Year Interval

On February 0, 2012 (ADAMS Accession No. ML12052a043), Detroit Edison submitted revised relief request no.

PRR-002 for the Inservice Testing Program Third 10-Year Interval. In order for the NRC staff to continue the review of the subject request, they would like the licensee to address the following request for additional information (RAI). Please provide this information on the docket by July 23, 2012. Please also arrange a teleconference, if you would like to discuss this RAI with the staff:

Revised PRR-002-RAI 1

Please provide more detail on why the design and procurement activities for this modification necessitate slipping the original modification date for two additional refueling outages.