ML12163A718
| ML12163A718 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 01/09/2012 |
| From: | - No Known Affiliation |
| To: | Division of License Renewal |
| References | |
| Download: ML12163A718 (2) | |
Text
1 LimerickNPEm Resource From:
Christopher.Wilson2@exeloncorp.com Sent:
Monday, January 09, 2012 4:48 PM To:
Kuntz, Robert
Subject:
Typo
- Rob, No need to discuss on the phone but specific to this DRAI, we believe there is a typo. The UFSAR section should be 3.8.4.6.2.1 versus what I highlighted below DRAI 3.5.2.1.1-1
Background
LRA Table 3.5.1, item 3.5.1-68 addresses high-strength structural bolting and states that it is not applicable because high strength structural bolts subject to SCC are not used in this application. The GALL Report recommends GALL Report AMP XI.S3, ASME Section XI, Subsection IWF to manage cracking due to stress corrosion cracking for this component group.
Issue The staff lacks sufficient information to evaluate the applicants claim because a review of UFSAR Sections 3.8.3.1.2, Reactor Pedestal, 3.8.6.2.1, Structural Steel Materials, and 3A.7.1.2.2.1, Downcomer Bracing System, state that high strength structural steel bolting is used. It is reasonable to assume that at least some of the referenced UFSAR sections are describing components that contain bolting within the scope of license renewal. The staff reviewed the LRA and did not find any other means by which SCC would be managed for high strength structural bolting.
Chris Wilson Exelon Nuclear KSQ License Renewal 610-765-5667 (office) 609-709-3249 (cell) 200 Exelon Way, KSA/2-E
- This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies. This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You. **************************************************
Hearing Identifier:
Limerick_LR_NonPublic Email Number:
436 Mail Envelope Properties (9A15F707EB47A04D882D9FEB352EDDF8038D87B8)
Subject:
Typo Sent Date:
1/9/2012 4:47:42 PM Received Date:
1/9/2012 4:47:52 PM From:
Christopher.Wilson2@exeloncorp.com Created By:
Christopher.Wilson2@exeloncorp.com Recipients:
"Kuntz, Robert" <Robert.Kuntz@nrc.gov>
Tracking Status: None Post Office:
cccmsxch12.energy.power.corp Files Size Date & Time MESSAGE 2137 1/9/2012 4:47:52 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: