Review of 60-day Response to Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 9.3 of the Near Term Task Force Review of Fukushima Dai-ichi Accident
ML12159A591
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 06/11/2012
From: Hall J
Plant Licensing Branch IV
To: Matthew Sunseri
Wolf Creek
Hall J
References
TAC ME8694
Download: ML12159A591 (8)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 11, 2012 Mr. Matthew W. Sunseri President and Chief Executive Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, KS 66839

SUBJECT:

WOLF CREEK GENERATING STATION - REVIEW OF 60-DAY RESPONSE TO REQUEST FOR INFORMATION REGARDING RECOMMENDATION 9.3 OF THE NEAR-TERM TASK FORCE RELATED TO THE FUKUSHIMA DAI-ICHI NUCLEAR POWER PLANT ACCIDENT (TAC NO. ME8694)

Dear Mr. Sunseri:

By letter dated March 12, 2012, the U.S. Nuclear Regulatory Commission (NRC or Commission) issued a Request for Information pursuant to Title 10 of the Code of Federal Regulations (10 CFR), paragraph 50.54(f) which included the Near Term Task Force (NTTF)

Recommendation 9.3 for Emergency Preparedness (EP). Specifically, licensees were requested to assess their means to power communications equipment on site and offsite during a prolonged Station Blackout (SBO) event and to perform a staffing study to determine the staff required to fill all necessary positions in response to a multi-unit event.

If a licensee could not meet the requested 90-day response, then that licensee was required to provide a response within 60 days of the issuance of the letter describing an alternative course of action and estimated completion date.

By letter dated May 9, 2012, Wolf Creek Nuclear Operating Corporation, the licensee for the Wolf Creek Generating Station, submitted its 60-day response proposing an alternative course of action based upon the higher priority to complete the implementation of the revised EP Rule. As discussed in the enclosed NRC staff evaluation, the licensee's alternative approach outlined in its 60-day response letter is consistent with the guidance of industry document Nuclear Energy Institute (NEI) 12-01, "Guidance for Assessing Beyond Design Basis Accident Response Staffing and Communications Capabilities,,,1 and the direction of the Commission.

In addition, the NRC staff concludes that the licensee provided an adequate basis for its proposed alternative to responding to the 50.54(f) Request for Information regarding communications and staffing for NTTF Recommendation 9.3. In its letter dated May 9, 2012, the licensee identified the regulatory commitments provided in the attachment to the enclosure to this letter.

NRC staff determined NE112-01 to be an acceptable approach in a letter dated May 15, 2012 (ADAMS Accession No. ML12131A043).

M. Sunseri

- 2 If you have any questions, please contact me at 301-415-4032 or via e-mail at randy.hall@nrc.gov.

Sincerely, James R. Hall, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-482

Enclosure:

Staff Evaluation cc w/encl: Distribution via Listserv

NUCLEAR REGULATORY COMMISSION STAFF EVALUATION INFORMATION REQUEST MADE UNDER 10 CFR 50.54(f)

REGARDING NEAR-TERM TASK FORCE RECOMMENDATION 9.3 WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION DOCKET NO. 50-482 By letter dated March 12, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12073A348), the U.S. Nuclear Regulatory Commission (NRC or Commission) issued a Request for Information pursuant to Title 10 of the Code of Federal Regulations (10 CFR), paragraph 50.54(f) which included the Near-Term Task Force (NTTF)

Recommendation 9.3 for Emergency Preparedness (EP).

Specifically, licensees were requested to assess their means to power communications equipment onsite and offsite during a prolonged Station Blackout (SBO) event and to perform a staffing study to determine the staff required to fill all necessary positions in response to a multi-unit event. If a licensee could not meet the requested 90-day response, then that licensee was required to provide a response within 60 days of the issuance of the letter describing an alternative course of action and estimated completion date.

By letter dated May 3,2012 (ADAMS Accession No. ML12125A410), the Nuclear Energy Institute (NEI) submitted NEI 12-01, "Guideline for Assessing Beyond Design Basis Accident Response Staffing and Communications Capabilities," Revision 0, May 2012. The NRC staff reviewed NEI 12-01 and found it to be an acceptable method for licensees to use when responding to the NRC's 10 CFR 50.54(f) Request for Information regarding communications and staffing for EP.

This staff evaluation is focused specifically on the licensee's response to the 10 CFR 50.54(f) letters and not on the associated Orders.

By letter dated May 9,2012 (ADAMS Accession No. ML12138A012), Wolf Creek Nuclear Operating Corporation (WCNOC), the licensee for the Wolf Creek Generating Station, submitted its 60-day response to the 10 CFR 50.54(f) Request for Information proposing an alternative course of action based upon the higher priority to complete the implementation of the revised EP Rule. The NRC staff reviewed the licensee's proposed alternative against the guidance contained in NEI 12-01. In addition, the NRC staff also considered the direction given by the Commission in the Staff Requirements Memorandum (SRM) to SECY 12-0025, "Proposed Orders and Requests for Information in Response to Lessons Learned from Japan's March 11, 2011, Great Tohoku Earthquake and Tsunami," dated March 9, 2012 (ADAMS Accession No. ML120690347). This SRM stated, in part, that Completing implementation activities associated with the rule we have already promulgated has greater safety significance and also involves the coordinated actions of our partners in State and local governments. Substantial public credibility benefits accrue from continuing these activities as a priority.

Enclosure

- 2 The NRC staff considers the existing EP framework and regulations provides reasonable assurance of adequate protection of public health and safety in the event of a radiological emergency. The revised EP rule that was promulgated on November 23, 2011, initiated a number of activities that will enhance EP programs, including conducting a staffing analysis and enhancing public notification systems. The implementation of the EP rule was given priority by the Commission and the NTTF recommendations should not displace ongoing work that has greater safety benefit, higher priority, or is necessary for continued safe operation of nuclear power plants. The NTTF Report concluded that continued operation and continued licensing activities do not pose an imminent risk to the public health and safety and are not inimical to the common defense and security.

The phased approach to responding to the 10 CFR 50.54(f) letters, combined with the definition of new response requirements associated with Fukushima NTTF Recommendation 4.2, as subsequently modified by the NRC staff and issued as NRC Order EA-12-049 (ADAMS Accession No. ML12054A736), will ensure that enhancements will be made to staffing and communications by licensees.

It should be noted that the 10 CFR 50.54(f) letter and implementation of the Order includes completion of actions related to response assignments, staffing changes, issuance of new or revised procedures or guidelines, and training. Activities are ongoing by both the NRC and industry to initiate interim actions as a result of lessons learned from the events which will be provided in the 90-day response such as:

Methods to access the site Notification of staff Interim actions taken to date Given the above and that the licensee's approach was found to be consistent with the guidance of NEI 12-01 and the direction of the Commission, the NRC staff concludes that the licensee has provided an adequate basis for its proposed alternative responding to the 10 CFR 50.54(f) letters regarding communications and staffing for Recommendation 9.3.

In its letter dated May 9, 2012, the licensee identified the regulatory commitments provided in the attachment to this staff evaluation.

Attachment

LIST OF REGULATORY COMMITMENTS PROVIDED IN WOLF CREEK NUCLEAR OPERATING CORPORATION'S LETTER DATED MAY 9, 2012 REGULATORY COMMITMENT DUE DATE Provide an assessment of the current communications systems and equipment used during an emergency event to identify any enhancements that may be needed to ensure communications are maintained during a large scale natural event meeting the conditions described [in the Discussion section]. The assessment should:

Identify any planned or potential improvements to existing onsite communications systems and their required normal and/or backup power supplies, Identify any planned or potential improvements to existing offsite communications systems and their required normal and/or backup power supplies, Provide a description of any new communications system(s} or technologies that will be deployed based upon the assumed conditions described above, and Provide a description of how the new and/or improved systems and power supplies will be able to provide for communications during a loss of all AC power

[Communications Request # 1]

October 31, 2012 Describe any interim actions that have been taken or are planned to be taken to enhance existing communications systems power supplies until the communications assessment and the resulting actions are complete.

[Communications Request # 2]

June 11, 2012 Conduct the communications assessment.

[Communications Request # 3]

September 28, 2012 Provide an implementation schedule of the time needed to implement the results of the communications assessment.

[Communications Request # 3]

October 31,2012 Attachment

- 2 REGULATORY COMMITMENT DUE DATE Provide an assessment of the onsite and augmented staff needed to September 5,2014*

respond to a large scale natural event meeting the conditions described

[in the Discussion section]. This assessment should include a

  • This date corresponds discussion of the onsite and augmented staff available to implement the to 4 months prior to strategies as discussed in the emergency plan and/or described in plant beginning of the second operating procedures. The following functions are requested to refueling outage, as be assessed:

used within the context of NRC Order How onsite staff will move back-up equipment (e.g., pumps, EA-12-049, which is generators) from alternate onsite storage facilities to repair currently scheduled to locations at each reactor as described in the order regarding the begin in January, 2015.

NTTF Recommendation 4.2. It is requested that consideration be given to the major functional areas of NUREG-0654, Table 8-1 such as plant operations and assessment of operational aspects, emergency direction and control, notification/communication, radiological accident assessment, and support of operational accident assessment, as appropriate.

  • New staff or functions identified as a result of the assessment.
  • Collateral duties (personnel not being prevented from timely performance of their assigned functions).

Provide onsite and augmented staffing assessment considering functions related to NTTF Recommendation 4.2. [Phase 2 staffing assessment]

[Staffing Request # 1]

Provide an implementation schedule of the time needed to conduct the August 5,2014*

onsite and augmented staffing assessment. If any modifications are

  • This date corresponds determined to be appropriate, please include in the schedule the time to to 5 months prior to implement the changes.

beginning of the second refueling outage, as

1. Conduct the onsite and augmented staffing assessment:

used within the context of NRC Order The onsite and augmented staffing assessment conSidering functions EA-12-049, which is related to NTTF Recommendation 4.2. [Phase 2 staffing assessment] currently scheduled to begin in January, 2015.

[Staffing Request # 2]

-3 REGULATORY COMMITMENT DUE DATE Provide an implementation schedule of the time needed to conduct the September 5,2014*

onsite and augmented staffing assessment. If any modifications are

  • This date corresponds determined to be appropriate, please include in the schedule the time to to 4 months prior to implement the changes.

beginning of the second

2. A schedule of the time to needed to implement changes will be provided as follows:

Those associated with the Phase 2 staffing assessment.

[Staffing Request # 2]

refueling outage, as used within the context of NRC Order EA-12 049, which is currently scheduled to begin in January, 2015.

Identify how the augmented staff would be notified given degraded communications capabilities.

[Staffing Request # 3]

June 11, 2012 Identify the methods of access (e.g.. roadways, navigable bodies of water and dockage, airlift, etc.) to the site that are expected to be available after a widespread large scale natural event.

[Staffing Request # 4]

June 11, 2012 Identify any interim actions that have been taken or are planned prior to June 11, 2012 the completion of the staffing assessment.

[Staffing Request # 5]

Identify changes that have been made or will be made to your September 5,2014*

emergency plan regarding the on-shift or augmented staffing changes necessary to respond to a loss of all AC power, multi-unit event,

  • This date corresponds including any new or revised agreements with offsite resource providers to 4 months prior to (e.g., staffing, equipment, transportation, etc.).

beginning of the second refueling outage, as Changes will be identified as follows:

used within the context of NRC Order EA-12 Those associated with the Phase 2 staffing assessment.

049, which is currently scheduled to begin in

[Staffing Request # 6]

January, 2015.

M. Sunseri

- 2 If you have any questions, please contact me at 301-415-4032 or via e-mail at randy.hall@nrc.gov.

Sincerely, IRA by KKalyanam for RHall1 James R. Hall, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-482

Enclosure:

Staff Evaluation cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC RidsAcrsAcnw_MailCTR Resource RidsNrrDorlLpl4 Resource RidsNrrLAJBurkhardt Resource RidsNrrPMWolfCreek Resource RidsNsirDpr Resource RidsOgcRp Resource RidsRgn4MailCenter Resource CMurray. NSIR JShea, NRRlJLD JKratchman, NRRlJLD ADAMS Accession No. ML12159A591 *concurrence via email OFFICE NRRlDORLlLPL4/PM NRRlDORLlLPL4/LA NSIRIDP NAME JRHall JBurkhardt KWilliams*

DATE 6/8/12 6/8/12 6/6112 OFFICE NRRlJLD/PMB/BC N RRlDORLlLP L4/BC N RRlDORLlLPL4/PM NAME Iii MMarkley KKalyanam for JRHali DATE 6/11/12 6/11/12 OFFICIAL RECORD COpy