Email -- Davis-Besse Non-Proprietary Photos Msh
ML12144A188
Person / Time
Site: Davis Besse 
Issue date: 05/21/2012
From: Wolf G
FirstEnergy Corp
To: Dave Hills, Mel Holmberg, Daniel Kimble, Sanchez-Santiago E, Atif Shaikh
NRC/RGN-III/DRP/B6, NRC/RGN-III/DRS/EB1
Melvin Holmberg
References
Download: ML12144A188 (11)


Text

Pictures for potential use in NRC Report-Request to Verify No Proprietary Information From: gmwolf@firstenergycorp.com [1]

Sent: Thursday, April 12, 2012 4:32 PM To: Holmberg, Mel; Shaikh, Atif; Kimble, Daniel; Hills, David; Sanchez Santiago, Elba; Neurauter, James Cc: jghook@firstenergycorp.com; thenry@firstenergycorp.com; klbrowning@firstenergycorp.com; pjmccloskey@firstenergycorp.com; sdhall@firstenergycorp.com; jyoung@firstenergycorp.com

Subject:

Re: Pictures for potential use in NRC Report-Request to Verify No Proprietary Information Mel - Davis-Besse personnel have reviewed the pictures and determined that none contain Proprietary Information.

However, we note that Picture No. 1 appears to be the identical picture posted to the Toledo Blade Newspaper's webpage at http://www.toledoblade.com/image/2012/02/28/800x600_b1_cCM/FirstEnergy-says-that-winddriven-rain-soaked-deep-into-the-concrete.jpg (this was already brought to the attention of Jim Neurauter who is on site today).

As we discussed on the telephone, Picture No. 3 shows the crack that was discovered as a result of the hydro-demolition process. It should be explained with this picture that the hydro-demolition process amplified the crack opening.

Picture No. 7 contained an incorrect date stamp (shows 10/26/2012 instead of 10/26/2011). The picture immediately below (S11-663.75-30-10.jpg) has a corrected date.

Gerry Wolf Supervisor, Nuclear Compliance Davis-Besse Regulatory Compliance desk: 419-321-8001 e-mail:GMWolf@FirstEnergyCorp.com From: "Holmberg, Mel" <Mel.Holmberg@nrc.gov>

To: "gmwolf@firstenergycorp.com" <gmwolf@firstenergycorp.com>

Cc: "Hills, David" <David.Hills@nrc.gov>, "Neurauter, James" <James.Neurauter@nrc.gov>, "Sanchez Santiago, Elba" <Elba.SanchezSantiago@nrc.gov>, "Shaikh, Atif" <Atif.Shaikh@nrc.gov>, "Kimble, Daniel"

<Daniel.Kimble@nrc.gov>

Date: 03/30/2012 11:23 AM

Subject:

Pictures for potential use in NRC Report-Request to Verify No Proprietary Information

Pictures for potential use in NRC Report-Re Gerry, Below are 12 pictures/figures described in your of the Davis-Besse shield building cracking. Ple proprietary materials. If any are considered prop them into our report. I will be out of the office ne each NRC member on my distribution for this E-Thank you Mel Holmberg Picture No. 1 - Davis-Besse Shield Building Picture No. 2 - Davis-Besse Shield Building Flu equest to Verify No Proprietary Information site records or vendor reports related to your investiga ease confirm that none of these pictures or figures con prietary, please identify these so we do not incorporate ext week, but please provide your E-mail response to

-mail.

te & Shoulder Details ation ntain e

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 3 - Davis-Besse Shield Building Laminar Subsurface Cracking

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 4-Davis-Besse Shield Building Impulse Response Testing Mobility Plot

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 5-Davis-Besse Shield Building Impulse Response Testing Mobility Plot (Shoulder 9)

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 6-Davis-Besse Shield Building Core Bore Location S7-667-25-2 Picture No. 7 -Davis-Besse Shield Building Core Bore Location S11-663.75-30-10

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 8 -Davis-Besse Shield Building - Core Bore Sample

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 9-Davis-Besse Shield Building Root Cause Analysis Report - Fault Tree

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 10 - Davis-Besse Shield Building - Water Migration

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 11 - Davis-Besse Shield Building -Location/Progression of Ice Formation

Davis-Bess Photos for Potential Use in NRC Report-Request to Verify No Proprietary Information Picture No. 12 - Davis-Besse Shield Building - Subsurface Radial Tensile Stress The information contained in this message is intended only for the personal and confidential use of the recipient(s) named above. If the reader of this message is not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message.