ML12138A295

From kanterella
Jump to navigation Jump to search
Final License Renewal Interim Staff Guidance, LR-ISG-2011-03, Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, Buried and Underground Piping and Tanks
ML12138A295
Person / Time
Issue date: 07/26/2012
From: Brian Holian
Division of License Renewal
To: Cavallo J, Daily S, Kleinfelder H, Remer J
Det Norske Veritas (USA), Nuclear Energy Institute, Mears Group Inc, USA
Hoston W, 415-8573
Shared Package
ML12138A294 List:
References
LR-ISG-2011-03
Download: ML12138A295 (6)


Text

July 26, 2012 Mr. Jason Remer Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708

SUBJECT:

FINAL LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2011-03, CHANGES TO THE GENERIC AGING LESSONS LEARNED (GALL) REPORT REVISION 2 AGING MANAGEMENT PROGRAM XI.M41, BURIED AND UNDERGROUND PIPING AND TANKS

Dear Mr. Remer:

On March 9, 2012, the U.S. Nuclear Regulatory Commission (NRC) published in the Federal Register (77 FR 14446) a request for public comments on draft license renewal interim staff guidance (LR-ISG) LR-ISG-2011-03, Changes to the Generic Aging Lessons Learned (GALL)

Report Revision 2 Aging Management Program (AMP) XI.M41, Buried and Underground Piping and Tanks. In response, the NRC received comments from your organization by letter dated April 20, 2012. The resolution of your comments is documented in Appendix G, Resolution of Public Comments, in the final LR-ISG-2011-03.

Enclosed is a copy of the final LR-ISG-2011-03 and the Federal Register notice announcing the issuance of the LR-ISG-2011-03.

To inform other stakeholders of the issuance of LR-ISG-2011-03, courtesy copies of this letter are being sent to subscribers of an NRC electronic mailing list on general license renewal topics.

Sincerely,

/RA M. Galloway for/

Brian E. Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/encls: Reactor License Renewal Stakeholder Group Listserv

July 26, 2012 Mr. Jon Cavallo P.O. Box 226 Eliot, ME 03903

SUBJECT:

FINAL LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2011-03, CHANGES TO THE GENERIC AGING LESSONS LEARNED (GALL) REPORT REVISION 2 AGING MANAGEMENT PROGRAM XI.M41, BURIED AND UNDERGROUND PIPING AND TANKS

Dear Mr. Cavallo:

On March 9, 2012, the U.S. Nuclear Regulatory Commission (NRC) published in the Federal Register (77 FR 14446) a request for public comments on draft license renewal interim staff guidance (LR-ISG) LR-ISG-2011-03, Changes to the Generic Aging Lessons Learned (GALL)

Report Revision 2 Aging Management Program (AMP) XI.M41, Buried and Underground Piping and Tanks. In response, the NRC received a comment from you on April 1, 2012. The resolution of your comment is documented in Appendix G, Resolution of Public Comments, in the final LR-ISG-2011-03.

Enclosed is a copy of the final LR-ISG-2011-03 and the Federal Register notice announcing the issuance of the LR-ISG-2011-03.

To inform other stakeholders of the issuance of LR-ISG-2011-03, courtesy copies of this letter are being sent to subscribers of an NRC electronic mailing list on general license renewal topics.

Sincerely,

/RA M. Galloway for/

Brian E. Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/encls: Reactor License Renewal Stakeholder Group Listserv

July 26, 2012 Mr. Henry Kleinfelder Mears Group 69 Argyle Place Orchard Park, NY 14127

SUBJECT:

FINAL LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2011-03, CHANGES TO THE GENERIC AGING LESSONS LEARNED (GALL) REPORT REVISION 2 AGING MANAGEMENT PROGRAM XI.M41, BURIED AND UNDERGROUND PIPING AND TANKS

Dear Mr. Kleinfelder:

On March 9, 2012, the U.S. Nuclear Regulatory Commission (NRC) published in the Federal Register (77 FR 14446) a request for public comments on draft license renewal interim staff guidance (LR-ISG) LR-ISG-2011-03, Changes to the Generic Aging Lessons Learned (GALL)

Report Revision 2 Aging Management Program (AMP) XI.M41, Buried and Underground Piping and Tanks. In response, the NRC received comments from your organization on April 9, 2012.

The resolution of your comments is documented in Appendix G, Resolution of Public Comments, in the final LR-ISG-2011-03.

Enclosed is a copy of the final LR-ISG-2011-03 and the Federal Register notice announcing the issuance of the LR-ISG-2011-03.

To inform other stakeholders of the issuance of LR-ISG-2011-03, courtesy copies of this letter are being sent to subscribers of an NRC electronic mailing list on general license renewal topics.

Sincerely,

/RA M. Galloway for/

Brian E. Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/encls: Reactor License Renewal Stakeholder Group Listserv

July 26, 2012 Mr. Steven Daily Det Norske Veritas (USA), Inc.

14533 Wallingford Ave. N.

Shoreline, WA 98133

SUBJECT:

FINAL LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2011-03, CHANGES TO THE GENERIC AGING LESSONS LEARNED (GALL) REPORT REVISION 2 AGING MANAGEMENT PROGRAM XI.M41, BURIED AND UNDERGROUND PIPING AND TANKS

Dear Mr. Daily:

On March 9, 2012, the U.S. Nuclear Regulatory Commission (NRC) published in the Federal Register (77 FR 14446) a request for public comments on draft license renewal interim staff guidance (LR-ISG) LR-ISG-2011-03, Changes to the Generic Aging Lessons Learned (GALL)

Report Revision 2 Aging Management Program (AMP) XI.M41, Buried and Underground Piping and Tanks. In response, the NRC received comments from your organization on April 13, 2012. The resolution of your comments is documented in Appendix G, Resolution of Public Comments, in the final LR-ISG-2011-03.

Enclosed is a copy of the final LR-ISG-2011-03 and the Federal Register notice announcing the issuance of the LR-ISG-2011-03.

To inform other stakeholders of the issuance of LR-ISG-2011-03, courtesy copies of this letter are being sent to subscribers of an NRC electronic mailing list on general license renewal topics.

Sincerely,

/RA M. Galloway for/

Brian E. Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/encls: Reactor License Renewal Stakeholder Group Listserv

ML12138A294 (package); ML12138A295 (letter); ML12138A296 (ISG);

ML12138A298 (FRN)

OFFICE ME:RAPB:DLR LA:RPB1:DLR PM:RPOB:DLR BC:RAPB:DLR NAME WHolston YEdmonds EGettys RAuluck DATE 6/25/12 7/19/12 5/30/12 7/20/12 OFFICE BC:RPOB:DLR BC:CPNB:DE OGC (NLO)

D:DLR NAME YDiaz-Sanabria TLupold MSpencer BHolian (MGalloway for)

DATE 5/30/12 6/25/12 7/10/12 7/26/12

Letter to Jason Remer et al. from Brian E. Holian dated July 26, 2012

SUBJECT:

FINAL LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2011-03, CHANGES TO THE GENERIC AGING LESSONS LEARNED (GALL) REPORT REVISION 2 AGING MANAGEMENT PROGRAM XI.M41, BURIED AND UNDERGROUND PIPING AND TANKS DISTRIBUTION:

E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRsrg Resource RidsNrrDra Resource RidsNrrDe Resource RidsNrrDss Resource RidsOgcMailCenter Resource RidsOpaMail Resource RidsOcaMailCenter Resource EGettys WHolston YDiaz-Sanabria JRivera,RII AStone, RIII NOKeefe, RIV RConte, RI