Text
Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 May 10, 2012 Ms. Dana Waits State of Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6 th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534
Dear Ms. Waits:
SEQUOYAH NUCLEAR PLANT - DISCHARGE MONITORING REPORT FOR APRIL 2012 Enclosed is the April 2012 Discharge Monitoring Report for Sequoyah Nuclear Plant. If you have any questions or need additional information, please contact Brad Love at (423) 843-6714 of Sequoyah's Environmental staff.
In a letter to Mr. Vojin Janjid dated December 21, 2011 Sequoyah notified TDEC of upcoming activities for the installation of pilings into bedrock to support a crane during the Unit 2 Cycle 18 refueling outage scheduled to begin in October 2012. This project is on going and to date there has been zero discharge of process water. Sequoyah will continue to update TDEC on this process and report any discharges and associated monitoring in future DMR's.
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
- Si n e Ire 3XQ President Sequoyah Nuclear Plant Enclosures cc (Enclosures):
Chattanooga Environmental Field Office U.S. Nuclear Regulatory Commission Division of Water Pollution Control Attn: Document Control Desk State Office Building, Suite 550 Washington, DC 20555 540 McCallie Avenue Chattanooga, Tennessee 37402-2013
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000
.-.LNTEROFFICE OPS-SN-SQN).
SODDY_- DAISY TN 37384 Faciiy TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
S TN0026450 1I 101 G
[ PERMIT NUMBER I DISCHARGE NUMBER[
MONITORING PERIOD YEARI MO I DAY I
YEAR MO DAY From 12 104 1011 To l 12 04 I 30 MAJOR Form Approved.
(SUBR 01)
OMB No. 2040-0 F - FINAL DIFFUSER DISCHARGE EFFLUENT NO DISCHARGE NOTE: Read instructions before completinq this form.
004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.
SAMPLE 33.8 04 0
30 /30 RCORDR CENTIGRADE MEASUREMENT 00010 1
0 PERMIT Req. Mon.
DEG.C.
CONTI CALCTD-EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS TEMPERATURE, WATER DEG.
SAMPLE 22.2 04 0
30/30 MODELD CENTIGRADE MEASUREMENT 00010 Z
0 PERMIT 30.5 DEG. C.
-CONTI CALCTD REQUIREMENT.,
INSTREAM MONITORING R
rDAILY MX NUOUS TEMP. DIFF. BETWEEN SAMP. &
SAMPLE 3
04 0
30 /30 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1
S PERMIT DEG.C.
CONT CALCTD EFFLUENT GROSS REQUIREMENT 3-.
D.....
CONTI CAL.TD FLOW, IN CONDUIT OR THRU SAMPLE 1718 03 0
30 / 30 RCORDR TREATMENT PLANT MEASUREMENT 50050 1
0 PERMIT Req Mon.
MGD CONTI RCORDR EFFLUENT GROSS R:.:DAILY MAX-
.NUOUS CHLORINE, TOTAL RESIDUAL SAMPLE 0.022 0.059 19 0
26/30 GRAB MEASUREMENT 50060 1
0 PERMIT.0.1 0.1
'MIL FIVEPER 'CALCTD EFFLUENT GROSS REQUIREMENT M A MWEEK MO "G DAWEEK TEMPERATURE - C, RATE OF SAMPLE 0
620 30 /30 CALCTD CHANGE MEASUREMENT 82234 1
0 PERMIT 2
DEG CONTI*CA"CTD 2,.
DEG
,********.COT" CALCTD EFFLUENT GROSS REQUIREMENT DAILYMX CIHR NUOUS'_.....
SAMPLE MEASUREMENT REQUIREMENT' NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE
-direction or supervision in accordance with a system designed to assure that qualified person el I
John T. Carlin properly gather and evaluate the information submitted. Bqsed on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the 8
(
ice President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 05 09 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIAT.URE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.
FI51CER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CD COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
No closed mode operation. Veliger monitoring data is included as an attachment. Spectrus CT1300 treatment began on 4/30/12 (max. calc. conc. was 0.037mg/L--limit 0.050mg/L).
EPA Form 3320-1 (REV 3/99)
Previous editions may be used Page 1 of 1
Mean#
of NOTES: %
Meana# of Water Mean# of Water Sample Date ZMCm3
% Settlers Temp. ('C)
Sample Date Asiatic Temp. ('C)
LOCATION SUB LOCATION Gravid Asiatic COLLECTED BY Clams0m3 Clam 01/03/2012 14 100 26 01/03/2012 0
26 1-25-545 PKS 01/10/2012 01/17/2011 01/24/2012 01/31/2012 02/07/2012 02/14/2012 02/21/2012 02/28/2012 03/06/2012 03/13/2012 03/20/2012 03/27/2012 04/03/2012 04/10/2012 04/18/2012 0
0 0
0 0
0 0
0 0
0 0
1623 229 79 326 0
0 0
0 0
0 0
0 0
0 0
1.3 0
20 5
9 10 13 17.6 12 8.3 26.5 11.1 11.7 13 14.6 17.2 18 22 18.8 01/10/2011 01/17/2011 01/24/2012 01/31/2012 02/07/2012 02/14/2012 02/21/2012 02/28/2011 03/06/2012 03/13/2012 03/20/2012 03/27/2012 04/03/2012 04/10/2012 04/18/2012 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
9 10
.13 17.6 12 8.3 26.5 11.1 11.7 13 14.6 17.2 18 22 18.8 RCW 1 -ISV-24-1234 1-25-545 1-25-545 1-25-545 1-24-1234 1-25-545 1 -ISV-24-1234 1 -ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 1-ISV-24-1234 WBE PB WDT CR BB WE CR WBE WBE WBE WBE WBE PB PB MJW
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN.)
SODDY - DAISY TN 37384 Facili.ty TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
TN0026450 101 T PERMIT NUMB7ER7
ýDI1SCHARGE NUMBER]
MONITORING PERIOD YEAR IMO I DAY From 12 04 01 To j 12 04 30 MAJOR Form Approved.
(SUBR 01)
OMB No. 2040-0 F - FINAL BIOMONITORING FOR OUTFALL 101 EFFLUENT NO DISCHARGE El]
NOTE: Read instructions before completing this form.
004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF "rYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE Monitoring 23 CERIODAPHNIA MEASUREMENT Not Required TRP3B 1
0 PERMIT 432 PERCENT SEMI COMPOS EFFLUENT GROSS MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE Monitoring
- 23 PIMEPHALES MEASUREMENT Not Required TRP6C 1
0 PERMIT 43.2 PERCENT SEMI COMPOS EFFLUENT GROSS REQUIREMENT MIMINUM ANNUAL SAMPLE MEASUREMENT PERMIT '
REQUIREMENT".
SAMPLE MEASUREMENT PERMIT REQUIREMENT" SAMPLE MEASUREMENT PERMIT'
-REQUIREMENT.
SAMPLE MEASUREMENT PERMIT; REQUIREMENT".,
SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personr el John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the e
- kaSite Vice President information, the information submitted is, to the best of my knowledge and belief, true, acdurate, 423 843-7001 12 05 09 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, IGN OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.
OFIER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED I
CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Toxicity was not sampled in April 2012.
EPA Form 3320-1 (REV 3199)
Previous editions may be used Page 1 of 1
PERMIITEE NAME/ADDRESS (include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 INTEROFFICE OPS-5N-SQN.)
SODDY-DAISY_ TN 37384 Faciliy TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
TN0026450 i
103 G PERMIT NUMBER DISCHARGE NUMBER]
MONITORING PERIOD MO DAY I YEAR MO DAY From [ 12 1 04 I01 1 To 1 12 04 1 30 MAJOR Form Approved.
(SUBR 01)
OMB No. 2040-01 F - FINAL LOW VOL. WASTE TREATMENT POND EFFLUENT NO DISCHARGE NOTE: Read instructions before completinq this form.
004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE 7
8 12 0
15/30 GRAB MEASUREMENT 00400 1
0 PERMIT 6..
-9 SU THREE/
GRAB REQUIREMENT EFFLUENT GROSSR EN MINIMUM MAXIMUM
- WEEK, SOLIDS, TOTAL SUSPENDED SAMPLE 9
10 19 0
2 / 30 GRAB MEASUREMENT 00530 1
0 PERMIT 30" 1I00 MG/L TWICE/
GRAB EFFLUENT GROSS REQUIREMENT.MO G
DAILY MX MONTH OIL AND GREASE SAMPLE
<6
<6 19 0
2 / 30 GRAB MEASUREMENT 00556 1
0 PERMIT
- 2.
-MGIL TWICE/
GRAB EFFLUENT GROSS
~REQUIREMENT
.1
_20MLTICI GA
-FLUN MO AVG '
DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE 1.127 1.268 030 30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050 1
0
- PERMIT,
.,ReciWon..
Roq Mon MGD SEE RCORDR EFFLUENT GROSS OAG DIYM ERMIT A' SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT' NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE
-direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the it ice President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 05 09 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, OF PRINCIPAL EXECUTIVE TYPED O including the possibility of fine and imprisonment for knowing violations.
O ICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED
_CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference aft attachments here)
EPA Form 3320-1 (REV 3199)
Previous editions may be used Page 1 of 1
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000,
..I-NTEROFFICE OPS.5.N-SQ.N).
SODDY.-
D.AISY-TN. 37384 Fac!W_
TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY-NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) MAJOR DISCHARGE MONITORING REPORT (DMR)
(SUBR 01)
TN0026450 110 G F - FINAL PERMIT NUMBER DISCHARGE NUMBER RECYCLED COOLING WATER MONITORING PERIOD
]
EFFLUENT Form Approved.
OMB No. 2040-0004 IFYomA I YEARM DAY From El 2 I04 01 1 To°1 12 0 4 1 30 ATTN: Brad Love PARAMETER NO DISCHARGE LjJ
- NOTE: Read instructions before completing this form.
FREQUENCY SAMPLE OF TYPE QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF.,
ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS TEMPERATURE, WATER DEG.
SAMPLE 4**
0 CENTIGRADE MEASUREMENT 00010 1
0 PERMIT
- REPORT DEG C
-CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX
.UoUS TEMPERATURE, WATER DEG.
SAMPLE 04 CENTIGRADE MEASUREMENT 00010 Z
0 PERMIT 30.5 DEG C
'CONTIN -CALCTD INSTREAM MONITORING REQUIREMENT DAILYMX uous TEMP. DIFF. BETWEEN SAMP. &
SAMPLE 04 UPSTRM DEG.C MEASUREMENT 00016 1
0 PERMIT 5
DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX U
.OiUS FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1
0 PERMIT
'Req. Mon.
MGD a CONTIN RCORDR EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS.
CHLORINE, TOTAL RESIDUAL SAMPLE
- 19 MEASUREMENT 50060 1
0
<-PERMIT-'
- 0.1 0.1 MG/L.
Five'per" ALCTD EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILY MX Week TEMPERATURE - C, RATE OF SAMPLE 04 CHANGE MEASUREMENT 04 82234 1
0 PERMIT 2
DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that quatlfied personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the S
o President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 05 09 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIG NAfI.Rt OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.
OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
No Discharge this Period EPA Form 3320-11 (REV 3/99)
Previous editions may be used Page 1 of 1
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN.)_
SODDY_- DAISY TN 37384 Facility.
TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
TN0026450 I
110 T PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD SYEARI MO I DAY I YEAR MOI DAY Fromu 12 04 101 1T 12 04 30-1 MAJOR Form Approved.
(SUBR 01)
OMB No. 2040-0004 F - FINAL RECYCLED COOLING WATER EFFLUENT NO DISCHARGE J...
NOTE: Read instructions before completinq this form.
PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS 1C25 STATRE 7DAY CHR SAMPLE 23 CERIODAPHNIA MEASUREMENT 23 TRP3B 1
0 0
P 43.2I PECNSMI C
POS
'REQUIREMENT.
EFFLUENT GROSS VALUE REQUIREMENT MINIMUM rANNUIAL IC25 STATRE 7DAY CHR SAMPLE 3**
2 PIMEPHALES MEASUREMENT TRP6C 1
0 0
PERMIT 432.2 PERCENT SEMI TCOMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL SAMPLE MEASUREMENT PERMIT MREQUIREMENT SAMPLE MEASUREMENT PERMIT REAUIREMENT SAMPLE MEASUREMENT P~ERMIT2:..
REQUIREMENT<c SAMPLE MEASUREMENT PERMIT.
~REQUIREMENT~
SAMPLE MEASUREMENT
,PERMIT-
~REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my
/>/i TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 05 09 Sequoyah Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIGNAItE'OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.
OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTEDCODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
No Discharge this Period EPA Form 3320-1 (REV 3199)
Previous editions may be used Page 1 of 1
PERMIT-EE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000
.(I-NTEROFFICE OPS-5N-SQN)
SODDY-DAISY TN 37384 Facity
"-TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) MAJOR DISCHARGE MONITORING REPORT (DMR)
(SUBR 01)
TN0026450 118 G I F-FINAL PERMIT NUMBERB DISCHARGE NUMBERl WASTEWATER & STORM WATER MONITORING PERIOD I
EFFLUENT Form Approved.
OMB No. 2040-0004 IYEAR I MO I DAY I YEAR I MO DAY From 12 T04 01 T To12 4J 30 NO DISCHARGE j
]...
NOTE: Read instructions before completinci this form.
PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)
SAMPLE MEASUREMENT 19 00300 1
0 PERMIT 2
MGIL
-TWICE/
GRAB EFFLUENT GROSS REQUIREMENT MINIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 19 MEASUREMENT 19 00530 1
0 PERMIT 100 MGIL
-TWICE/
GRAB EFFLUENT GROSS REQUIREMENT DAILY MX
'WEEK SOLIDS, SETTLEABLE SAMPLE 2*
MEASUREMENT 25 00545 1
0 PERMIT MLIL ONCE/
GRAB EFFLUENT GROSS REQUIREMENT'
_° DAILY MX'
'MONTH FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1
0 PERMIT Req. Mon.
Req. Mon.,'
MGD ONCE/
.ESTIMA EFFLUENT GROSS MO A G
)DAILY-M C
SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT., -
SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE dlirection or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the ite Vice President Sequoyah Site Vice President information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 12 05 09 and complete. I am aware that there are significant penalties for submitting false information,
ýI dURE OF PRINCIPAL EXECUTIVE ncluding the possibility of fine and imprisonment for knowing violations.
-OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED nCODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.
EPA Form 3320-1 (REV 3199)
Previous editions may be used Page 1 of I