SEntergy Enteray Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Tel (914) 788-2055 Fred Dacimo Vice President License Renewal NL-09-079 June 12, 2009 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

SUBJECT:

REFERENCES:

Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event Indian Point Nuclear Generating Unit Nos. 2 & 3 Docket Nos. 50-247 and 50-286 License Nos. DPR-26 and DPR-64

1. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Nos. 2 and 3, License Renewal Application - Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event

Dear Sir or Madam:

Entergy Nuclear Operations, Inc is providing, in Attachment I, the additional information requested in the referenced letter pertaining to NRC review of the License Renewal Application for Indian Point 2 and Indian Point 3. The additional information provided in this transmittal addresses staff questions regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event. Attachment 2 consists of Revision 9 to the list of regulatory commitments.

If you have any questions, or require additional information, please contact Mr. Robert Walpole at 914-734-6710.

I declare under penalty of perjury that the foregoing is true and correct. Executed on Sincerely, kiz~

ENT000403 Submitted: May 9, 2012

NL-09-079 Page 2 of 2 FRD/dmt

Attachment:

1.

Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event

2.

List of Regulatory Commitments, Revision 9 cc:

Mr. Samuel J. Collins, Regional Administrator, NRC Region I Mr. Sherwin E. Turk, NRC Office of General Counsel, Special Counsel Ms. Kimberly Green, NRC Safety Project Manager Mr. Kenneth Chang, NRC Branch Chief, Engineering Review Branch I Mr. John Boska, NRR Senior Project Manager Mr. Paul Eddy, New York State Department of Public Service NRC Resident Inspector's Office Mr. Francis J. Murray, President and CEO, NYSERDA

ATTACHMENT 1 TO NL-09-079 Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 & 3 DOCKET NOS. 50-247 AND 50-286

Attachment I NL-09-079 Page 22 of 51 Table 3.4.2-5-3-1P2 Circulating Water System (CIRC)

Intended Aging Effect Aging Management NUREG0 Table I Copntt y e

nMteildevrnmn Requiring 1801 Vol. 2Noe Component Type Function Management Programs Item Item Pressure Change of Periodic Surveillance 408 Expansion int boundary Elastomer Air -outdoor (ext) material and Preventive G

properties Maintenance P eNe VILI.E-1 3.4.1-11 408 Piping boundary Carbon steel Soil (ext)

Loss of material Buried Piping And Tanks (S-01)

C aInspection Pressure NeiNe VIII.H-8 3.4.1-28 408 Piping boundary Carbon steel Air outdoor (ext)

Loss ofme External Surfaces S

A Noe VIII.G-36 3.4.1-8 408 Piping Pressure Carbon steel Raw water (int)

NOe Periodic Surveillance (S-12)

E boundary Loss of material and Preventive Maintenance Pressure Nee eA VJII.H-8 3.4.1-28 408 Pump casing boundary Carbon steel Air-outdoor (ext)

Loss of material Axternaq N41e VIII.G-36 3.4.1-8 498 Pump casing Pressure Carbon steel Raw water (int)

Nene Periodic Surveillance (S-12 E

boundary Loss of material and Preventive Maintenance Pressure Periodic Surveillance VIII.G-36 3.4.1-8 408 Pump casing boundary Carbon steel Raw water (ext)

Loss of material and Preventive (S-12)

E Maintenance