May 9, 2012 Mr. Peter Kolb NASA Decommissioning Program Manager NASA Plum Brook Station 6100 Columbus Avenue, Sandusky, Ohio 44870
SUBJECT:
NASA RESPONSE TO U.S. NUCLEAR REGULATORY COMMISSION STAFF COMMENTS ON FINAL STATUS SURVEY REPORT ATTACHMENTS FOR THE PLUM BROOK REACTOR FACILITY
Dear Mr. Kolb:
On February 2, 2012, National Aeronautics and Space Administration (NASA) submitted responses (ML12034A139) to U.S. Nuclear Regulatory Commission (NRC) comments (ML113570421) on Final Status Survey Report (FSSR), Attachments 7, 8, 9, 10, 11 and 13.
NASAs comment response also resulted in revisions to some FSSR attachments (ML121000153 and ML12020A096).
NRC has reviewed NASAs comment responses and FSSR revisions, as noted above, and has determined that NASA has adequately addressed NRCs comments. At this time, NRC has no further comments on these FSSR Attachments.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS).
ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
If you have any questions concerning the above, please contact Chad Glenn at (301) 415-6722 or via email at Chad.Glenn@nrc.gov.
Sincerely,
/RA/
Paul Michalak, Chief Materials Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs License No.: TR-3 and R-93 Docket No.: 50-30 and 50-185 cc: See next page
Mr. Peter Kolb NASA Decommissioning Program Manager NASA Plum Brook Station 6100 Columbus Avenue, Sandusky, Ohio 44870
SUBJECT:
NASA RESPONSE TO U.S. NUCLEAR REGULATORY COMMISSION STAFF COMMENTS ON FINAL STATUS SURVEY REPORT ATTACHMENTS FOR THE PLUM BROOK REACTOR FACILITY
Dear Mr. Kolb:
On February 2, 2012, National Aeronautics and Space Administration (NASA) submitted responses (ML12034A139) to U.S. Nuclear Regulatory Commission (NRC) comments (ML113570421) on Final Status Survey Report (FSSR), Attachments 7, 8, 9, 10, 11 and 13.
NASAs comment response also resulted in revisions to some FSSR attachments (ML121000153 and ML12020A096).
NRC has reviewed NASAs comment responses and FSSR revisions, as noted above, and has determined that NASA has adequately addressed NRCs comments. At this time, NRC has no further comments on these FSSR Attachments.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS).
ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
If you have any questions concerning the above, please contact Chad Glenn at (301) 415-6722 or via email at Chad.Glenn@nrc.gov.
Sincerely, Paul Michalak, Chief Materials Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs License No.: TR-3 and R-93 Docket No.: 50-30 and 50-185 cc: See next page ML121240702 OFC DWMEP DWMEP DWMEP NAME CGlenn SAchten PMichalak DATE 5/8/12 5/8/12 5/9/12 OFFICIAL RECORD COPY
National Aeronautics and Space Administration Service List - Chad Glenn, Project Manager cc:
Ohio Department of Health ATTN: Radiological Health Program Director P.O. Box 118 Columbus, OH 43216 Ohio Environmental Protection Agency Division of Planning Environmental Assessment Section P.O. Box 1049 Columbus, OH 43216 Mike Rubadue Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43216