Followup RAI Questions Related to Exelon Response to RAI Question #7 Attachments:
image001.jpg
- 1. What is the temporary tooling (after which the response states Code Case N-638-4 requires another surface examination)? N-638-4 requires another surface examination after weld-attached thermocouples are removed in paragraph 4a(3).
- 2. Code Case N-638-4 Paragraph 4(a)(4) states that Acceptance criteria for surface and volumetric examination shall be in accordance with Construction Code or Section III. For some of the examinations, the response to RAI 7 references [ASME] Section III, 1992 Edition, while for other examinations, [ASME Code] Section III, 1965 Edition, Summer 1965 Addenda is referenced. Code Case N-416-3 references the ASME Code,Section III, 1992 Edition for NDE methods and acceptance criteria. Explain the logic for referencing the original construction code of record (Section III, 1965 Edition, Summer 1965 Addenda) for some examinations and Section III, 1992 Edition for other examinations
- 3. Confirm that Code Cases N-405-1 and N-416-3 are incorporated in the QCNPS ISI Program.
Hearing Identifier:
NRR_PMDA Email Number:
335 Mail Envelope Properties (1A97AE0578A58B46BC77AA0B5DBD72023BF3D445E1)
Subject:
Followup RAI Questions Related to Exelon Response to RAI Question #7 Sent Date:
4/12/2012 3:40:52 PM Received Date:
4/12/2012 3:40:00 PM From:
Wiebe, Joel Created By:
Joel.Wiebe@nrc.gov Recipients:
"David Gullott" <David.Gullott@ExelonCorp.com>
Tracking Status: None "Joseph Bauer" <Joseph.Bauer@exeloncorp.com>
Tracking Status: None "Mitchel Mathews" <Mitchel.Mathews@exeloncorp.com>
Tracking Status: None Post Office:
HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 1065 4/12/2012 3:40:00 PM image001.jpg 11907 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: