MONTHYEARML22308A2392022-11-0808 November 2022 Documentation of Approval for Longer Review Period for Limerick Digital Instrumentation and Control License Amendment Requests Acceptance Review ML22034A3932022-02-16016 February 2022 Calendar Year 2021 Security Baseline Completion Memo ML21277A2472021-11-0505 November 2021 Notification of Significant Licensing Action - Proposed Issuance of Order Approving the Transfer of Licenses for Which a Hearing Has Been Requested - Exelon Generation Company, LLC; Et. Al ML18138A3442018-05-22022 May 2018 2018 Limerick Summary of Public Meeting and Attendance List ML17142A2382017-05-25025 May 2017 OEDO-17-00280 - Briefing Package for Drop-In Visit on June 9, 2017, by Senior Management of Exelon Generation Company, LLC with Chairman Svinicki, Commissioner Baran, and Commissioner Burns ML17037B8502017-02-0606 February 2017 08/21/1975 Notice of Meeting with Architect Engineers of Mark II Owners to Discuss Load Combinations and Analytical Techniques for Determining Stresses in Mechanical Components and Structures of Mark II Containments ML16344A2192016-12-12012 December 2016 Safety Evaluation for Limerick, Units 1 and 2, Proposed License Amendment to Revise the Technical Specifications to Address the High-Pressure Coolant Injection Operability Requirement Under Low Reactor Pressure Conditions ML16221A6712016-08-0808 August 2016 Draft Request for Additional Information ML16221A6122016-08-0808 August 2016 Draft Request for Additional Information ML16174A2982016-06-22022 June 2016 Draft Request for Additional Information ML16166A0862016-06-14014 June 2016 Draft Request for Additional Information ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16085A0252016-03-24024 March 2016 Draft Request for Additional Information ML16075A3292016-03-16016 March 2016 OEDO-16-00165 - Briefing Package for Drop-In Visit on March 23, 2016, by Senior Management of Exelon Generation Company, LLC with the NRC Executive Director for Operations ML15202A3782015-07-21021 July 2015 Draft Request for Additional Information ML15028A4502015-01-27027 January 2015 LG-15-014 Verification of Readiness for Supplemental Inspection at Limerick Generating Station ML15035A1122015-01-10010 January 2015 LTR-15-0061 Lewis Cuthbert, President, Alliance for a Clean Environment, ACE, Letter Lessons Learned from Fukushima Related to Limerick Nuclear Plant ML14267A0762014-09-23023 September 2014 Acknowledgement Letter: B. Shank and C. Shank Regarding Limerick Nuclear Power Plant ML14247A6482014-09-10010 September 2014 Supplemental Safety Evaluation Report ML14190A9442014-08-11011 August 2014 Forwarding of Supplement 1 to the Safety Evaluation Report Related to the License Renewal of Limerick Generating Station, Units 1 and 2, Docket Numbers 50-352 and 50-353, to the Advisory Committee on Reactor Safeguards ML14210A5762014-07-29029 July 2014 Draft Request for Additional Information (Tac Nos. MF3198 and MF3199) ML14202A5182014-07-21021 July 2014 Draft Request for Additional Information (Tac Nos. MF3085 and MF3086) ML14055A5322014-03-11011 March 2014 Summary of Telephone Conference Call Held on January 30, 2014. Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick Generating Station, ML14066A0972014-03-0707 March 2014 Draft Request for Additional Information ML14030A0942014-01-29029 January 2014 Draft Request for Additional Information (TAC Nos. MF1399 and MF1400) ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13190A3522013-07-10010 July 2013 Notice of Forthcoming Teleconference with Exelon Generation Company, LLC ML13156A0902013-06-26026 June 2013 Dseis Meeting Summary ML13109A5392013-05-0303 May 2013 5/23/2013 - Meeting Notice: Forthcoming Meeting to Discuss the Draft Supplemental Environmental Impact Statement for the License Renewal of Limerick Generating Station, Units 1 and 2 ML12348A6962012-12-17017 December 2012 1/3/2013 - Notice of Forthcoming Meeting with Exelon Generation Company, LLC, to Discuss Requests for Additional Information Regarding Exelon Physical Security Plans ML1227704332012-10-0101 October 2012 Minutes of the ACRS Plant License Renewal Subcommittee Meeting on September 5, 2012 (Open) ML12139A0612012-06-25025 June 2012 Summary of Telephone Conference Call Held on May 16, 2012, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick Generating Station, Lice ML1210403072012-04-12012 April 2012 Draft Request for Additional Information ML12083A2112012-04-11011 April 2012 Summary of Telephone Conference Call Held on February 23, 2012 Between the U.S. Nuclear Regulatory Commission and Exelon Generating Company, LLC, Concerning Request for Additional Information Pertaining to the Limerickgenerating Station, Li ML1208602902012-03-26026 March 2012 Notice of Forthcoming Public Meeting with Exelon Generation to Discuss Future Fleet Submittal Regarding Licensed Operator Eligibility Requirements ML1135300442011-12-19019 December 2011 Electronic Transmission, Draft Request for Additional Information Regarding Proposed Technical Specification Safety Limit Minimum Critical Power Ratio Changes ML1133402312011-12-12012 December 2011 Request for Additional Information for Limerick Generating Station, Units 1 and 2 License Renewal Application-Scoping and Screening (TAC Nos. ME6555 and ME6556) ML11272A2372011-10-26026 October 2011 Summary of Public Scoping Meetings Related to the Review of the Limerick Generating Station, Units 1 and 2, LRA ML11251A0672011-09-12012 September 2011 Forthcoming Meeting to Discuss the License Renewal Process and Environmental Scoping for Limerick Generating Station, Units 1 and 2, License Renewal Application ML11245A0082011-09-0606 September 2011 09/22/2011 Notice of Forthcoming Meeting to Discuss the License Renewal Process and Environmental Scoping for Limerick Generating Station, Units 1 and 2, License Renewal Application ML1124104422011-08-29029 August 2011 Corrected Transcript for 10 CFR 2.206 Petition Regarding Limerick Scrams - Second Teleconference with Petitioner ML1121606122011-08-0808 August 2011 Memorandum to File: Transcript for 10 CFR 2.206 Petition Regarding Limerick Scrams - Second Teleconference with Petitioner ML1117803082011-06-28028 June 2011 Memo to File Documenting Transcript for 10 CFR 2.206 Petition Regarding Limerick Scrams - Initial Teleconference with Petitioner ML1114403042011-05-24024 May 2011 Summary of Annual Assessment Meeting, Limerick Generating Station, on May 18, 2011 ML1103800542011-03-18018 March 2011 Summary of Telephone Conference Call Held on 1/28/11, Between the USNRC and Exelon Generation Company, LLC, Concerning the Proposed Limerick Generating Station, Units 1 and 2, License Renewal Application ML1105502222011-02-24024 February 2011 Electronic Transmission, Draft Request for Additional Information Regarding Proposed Technical Specification Allowed Outage Time Extensions to Support Residual Heat Removal Service Water (RHRSW) Maintenance ML1103304292011-02-0303 February 2011 Electronic Transmission, Draft Request for Additional Information Regarding Proposed Technical Specification Safety Limit Minimum Critical Power Ratio Changes ML1032004852010-11-16016 November 2010 Electronic Transmission, Draft Request for Additional Information Proposed Technical Specification Changes to High Pressure Coolant Injection Equipment Room Delta Temperature Trip Setpoint ML1032105082010-11-16016 November 2010 Units 1 & 2 - Electronic Transmission, Draft Request for Additional Information Regarding Request to Implement Emergency Action Level Scheme Change to NEI 99-01, Revision 5 2022-02-16
[Table view] Category:Meeting Summary
MONTHYEARML23320A2472023-11-17017 November 2023 Constellation - Summary of November 14, 2023, Public Pre-Application Meeting with Constellation Energy Generation, LLC on Adoption of TSTF-591 ML23263B1062023-09-22022 September 2023 R. E. Ginna Nuclear Power Plant - Constellation - Pre-Application Amse 9/18/2023 Meeting Summary ML23236A5132023-08-31031 August 2023 Summary of Meeting with Constellation Energy Generation, LLC Regarding Digital Modernization License Amendment Request ML23179A0012023-06-28028 June 2023 6/7/2023 - Annual Assessment Meeting for Pa/Md/Ny/Nj Nuclear Power Plants - Meeting Summary ML23156A2472023-06-0909 June 2023 Summary of Meeting with Constellation Energy Generation, LLC Regarding Digital Modernization License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23118A3752023-06-0909 June 2023 Summary of Audit Meeting with Constellation Energy Generation Concerning a Digital Instrumentation and Control Upgrade License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23145A0352023-05-31031 May 2023 Summary of May 17, 2023, Meeting with Constellation Energy Generation, LLC Regarding Digital Modernization License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23132A3082023-05-18018 May 2023 Summary of May 3, 2023, Audit Meeting with Constellation Energy Generation Concerning a Digital Instrumentation and Control Upgrade License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23076A0132023-05-12012 May 2023 March 15, 2023, Summary of Audit Meeting with Constellation Energy Generation Concerning a Digital Instrumentation and Control Upgrade License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23076A1042023-05-12012 May 2023 Summary of Audit Meeting with Constellation Energy Generation Concerning a Digital Instrumentation and Control Upgrade License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23121A0022023-05-12012 May 2023 Summary of March 29, 2023, Audit Meeting with Constellation Energy Generation Concerning a Digital Instrumentation and Control Upgrade License Amendment Request for Limerick Generating Station, Units 1 and 2 ML23076A2802023-03-28028 March 2023 Summary of February 23, 2023, Public Observation Meeting with Constellation Energy Generation, LLC Re. Proposed License Amendment Request to Modify 10 CFR 50.69 License Conditions ML23055A0352023-03-24024 March 2023 Summary of February 23, 2023, with Constellation Energy Generation, LLC on Proposed Changes to Emergency Plans to Revise Emergency Action Levels ML23030A0092023-02-10010 February 2023 January 10, 2023, Summary of Meeting with Constellation Energy Generation, LLC, on Planned Limerick Digital Modernization Project Installation Support License Amendment Request and Exemption Request ML23009A5872023-01-11011 January 2023 Summary of December 15, 2022, Meeting with Constellation Energy Generation, LLC on Potential Compliance with Certain Clauses of IEEE Standard 603-1991 in Limerick Digital Instrumentation and Controls License Amendment Requests ML22327A0192022-12-0606 December 2022 Summary of November 10, 2022, Meeting with Constellation Energy Generation, Lic on Acceptance Review of Limerick Digital Instrumentation and Controls License Amendment Requests ML22227A1112022-08-25025 August 2022 Summary of June 24, 2022, Public Observation Meeting with Constellation Energy Generation, LLC Proposed License Amendment Request to Modify 10 CFR 50.69 License Conditions ML22187A1462022-07-0606 July 2022 Joint Annual Assessment Meeting for Pa/Md/Nj/Ny Nuclear Power Plants - Meeting Summary ML22168A1922022-06-24024 June 2022 Summary of May 3, 2022, Public Observation Meeting with Constellation Energy Generation, LLC Re. Proposed License Amendment Request to Modify 10 CFR 50.69 License Conditions ML22038A0992022-02-23023 February 2022 Summary of January 11, 2022, Public Meeting with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment Request ML22021B2942022-02-0202 February 2022 Summary of December 7, 2021, Public Meeting with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment ML21333A1532021-11-30030 November 2021 Summary of November 16, 2021, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Extend the Inservice Inspection Interval ML21301A1612021-11-15015 November 2021 Summary of June 29, 2021, Public Meeting with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment Request for Limerick Generating Station, Units 1 and 2 ML21294A3692021-11-15015 November 2021 Summary of October 6, 2021, Public Observation Meeting with Exelon Generation Company, LLC Proposed License Amendment Request to Modify Emergency Diesel Generator and Emregency Core Cooling System Surveillance Requirements ML21300A2772021-11-0909 November 2021 Summary of October 20, 2021, Pre-Submittal Public Teams Meeting with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment Request ML21294A3792021-10-0606 October 2021 WCAP-17308 Implementation Licensing Amendment Request Pre-Submittal Meeting Presentation, October 6, 2021 ML21237A0412021-08-30030 August 2021 Summary of the July 27, 2021, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Use Case OMN-28, ML21176A0822021-07-0606 July 2021 June 15, 2021, Summary of Meeting with Exelon Generation Company, LLC Vessel Nozzle Repair Related to a Planned Request for an Alternative Related to Reactor Pressure ML21139A1852021-06-22022 June 2021 Summary of Meeting with Exelon Generation Company, LLC Regarding Its Requested Alternative to Eliminate Certain Documentation Requirements for the Replacement of Pressure Retaining Bolting ML21123A1362021-05-13013 May 2021 Summary of March 16, 2021, Public Webinar with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment Request ML21071A1022021-03-24024 March 2021 Summary of the February 23, 2021, Meeting with Exelon Regarding a Future License Amendment Request Related to Implementing an Alternative Categorization Process Under the Requirements of 10 CFR 50.69 ML21011A2822021-01-21021 January 2021 Summary of January 6, 2021, Presubmittal Meeting Between the NRC and Exelon Generation Company, LLC Regarding Licensing Activities to Support the Planned Early Closures of Byron, Unit Nos. 1 and 2 and Dresden, Units 2 and 3 ML20351A2832020-12-18018 December 2020 Summary of Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Exemption to Reduce the Frequency of Updates to Its Inservice Testing and Inspection Programs ML20342A3522020-12-10010 December 2020 Summary of November 13, 2020, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alterantive to Certain Documentation Requirements for the Replacement of Pressure Retaining Bolting (EPID-L-2020-LRM-0102) ML20323A0332020-12-0101 December 2020 Summary of November 4, 2020, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Reduce the Frequency of Updates to Its Inservice Testing and Inspection Programs ML20197A2722020-07-15015 July 2020 2020 Beaver Valley, Calvert Cliffs, Limerick Peach Bottom, Susquehanna Annual Assessment Webinar Summary ML20175A2402020-06-30030 June 2020 Summary of June 12, 2020, Public Telephone Conference with Exelon Generation Company, LLC Regarding Planned Digital Modernization License Amendment Request ML20181A0002020-06-29029 June 2020 Summary of 6/24/20 Meeting with Exelon Generation Company, LLC Regarding Planned Request for Alternative to Supplemental Valve Position Indication Testing Requirements for Braidwood, Calvert Cliffs, Clinton, Limerick, Nine Mile, Peach Botto ML19326A3152019-12-0303 December 2019 Summary of November 18, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Supplemental Valve Position Indication Testing Requirements ML19326C3582019-12-0303 December 2019 Summary of November 20, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Revise the Quality Assurance Program ML19191A1882019-07-0909 July 2019 Joint Annual Assessment Meeting (Webinar) for Pennsylvania Power Plants - Meeting Summary ML19162A0272019-06-21021 June 2019 Summary of June 4, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Extend the Test Interval for Safety Relief Valves ML20108F0902019-04-20020 April 2019 April 15, 2020, Meeting Summary with Exelon Generation Company, LLC Regarding Planned Request to Defer Submittal of Owner'S Activity Report (Braidwood 2,Byron 2,Calvert Cliffs 1, LaSalle 1, Limerick 1, Nine Mile Point 2, Quad 2, R. E. Ginna ML19036A8832019-02-0707 February 2019 Summary of Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Use ASME Code Case N-879 ML18354B1712019-01-0202 January 2019 Summary of December 19, 2018, Meeting with Exelon Generation Company, LLC Regarding the Use of Boiling Water Reactor Vessel and Internals Project Guidelines ML18325A1712018-11-28028 November 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Planned Fleet License Amendment Request to Revise Technical Specifications for High Radiation Areas ML18297A1722018-10-26026 October 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Planned License Amendment Request to Adopt TSTF-427 ML18138A3442018-05-22022 May 2018 2018 Limerick Summary of Public Meeting and Attendance List ML18120A1772018-05-0101 May 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Draft Guidance for Emergency Response Organization Staffing ML18110A0122018-04-25025 April 2018 April 12, 2018, Summary of Meeting with Exelon Generation Company, Limerick, Units 1 and 2 - Regarding Their License Amendment Application for 10.CFR.50.69 Risk Informed Categorization of Structures Systems and Components. 2023-09-22
[Table view] |
Text
\.\:.p..R REGU/ _ UNITED STATES
",+,," "'ce,°'l l" NUCLEAR REGULATORY COMMISSION t:! ("> WASHINGTON, D.C. 20555..0001
<< 0
\ii~
~ ~
J April 11, 2012
" J ~o
LICENSEE: Exelon Generation Company, LLC FACILITY: Limerick Generating Station SUB,JECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON FEBRUARY 23,2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE LIMERICK GENERATING STATION, LICENSE RENEWAL APPLICATION The US. Nuclear Regulatory Commission (NRC or the staff) and representatives of Exelon Generation Company, LLC held a telephone conference call on February 23,2012, to discuss and clarify the staff's requests for additional information (RAls) concerning the Limerick Generating Station license renewal application. The telephone conference call was useful in clarifying the intent of the staff's RAls.
Enclosure 1 provides a listing of the participants and Enclosure 2 contains a listing of the RAls discussed with the applicant, including a brief description on the status of the items The applicant had an opportunity to comment on this summary.
Leslie Perkins, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353 Enclosures.
As stated cc w/encls: Listserv
TELEPHONE CONFERENCE CALL LIMERICK GENERATING STATION LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS FEBRUARY 23,2012 PARTICIPANTS AFFILIATIONS Leslie Perkins U.S. Nuclear Regulatory Commission (NRC)
Michelle Moser NRC Briana Balsam NRC Kevin Folk NRC Ann Miracle Pacific Northwest National Laboratory (PNNL)
James Becker PNNL Nancy Ranek Exelon Generation Company, LLC. (Exelon)
Chris Wilson Exelon AI Fulvio Exelon Robert Tarr Exelon ENCLOSURE 1
REQUESTS FOR ADDITIONAL INFORMATION LICENSE RENEWAL APPLICATION FEBRUARY 23,2012 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Exelon Generation Company, LLC (Exelon) held a telephone conference call on February 23,2012, to discuss and clarify the following requests for additional information (RAls) concerning the license renewal application (LRA).
Aquatic Ecology
- 1. Possum Hollow Creek is downstream of the Limerick Generating Station (LGS) power block. Provide any sampling or monitoring reports for aquatic species and benthos from Possum Hollow Creek.
2, LGS withdraws cooling water from the Schuylkill River at the Schuylkill River pumphouse, The through screen intake velocity can influence impingement rates. Describe the through screen intake velocity for the Schuylkill River pumphouse, Discussion: The applicant requested that the staff confirm that the staff was requesting a write-up of the verbal descriptions of screen intake velocity for the Schuylkill River, as provided by URS at the Surface Water Hydrology Interview during the environmental audit. The staff confirmed that they were requesting a write-up of the verbal description provided during the Environmental Audit.
3, Provide a description of screen clearing and maintenance activities and frequency at the Schuylkill Pumphouse, the Perkiomen Pumphouse, and Point Pleasant Pumping Station.
Discussion: The applicant stated the Exelon does not own or operate the Point Pleasant Pumping Station and does not conduct the activities of screen clearing and maintenance at that facility. The applicant requested that the NRC clarify that the staff expects Exelon to provide requested information for Point Pleasant Pumping Station. The staff understood that Exelon did not own or operate the Point Pleasant Pumping Station and clarified that the staff would like Exelon to provide requested information for Point Pleasant Pumping Station if the information is available. The staff agreed to revise the RAI for clarity. The RAI has been revised to read as follows:
Provide a description of screen clearing and maintenance activities and frequency at the Schuylkill Pumphouse and the Perkiomen Pumphouse, which are owned and operated by Exelon. If available, provide a description of the screen clearing and maintenance activities and frequency at the Point Pleasant Pumping Station, which is not owned by Exelon.
- 4. Zebra mussels are a non-native species that may occur within the waterbodies from which LGS withdraws. Describe zebra mussel monitoring and survey efforts, and discuss whether LGS staff has identified zebra mussels in any of the water bodies associated with the makeup water system of LGS.
Discussion: The applicant did not have any questions regarding Items 1 and 4.
ENCLOSURE 2
References Requested for Docketing at the Limerick Generating Station Environmental Site Audit November 7-10, 2011
~-~~--------=-~----,:----,:--=----=:---::-:------------~----~~--~
~ ~ ~ Meteorology and Air Quality m m m m _ _ _--/
fA Title V Operating Permit, TVOP-46-00038, Issued December 7,2009 and Revised
~ February 17, 2019._ __
lB. Title V Compliance Certification RE?ports (2006-2010) mm _________
~ ____ ~ ~~~~~~~~~___ Aq uatic Ecology ~ ~ ~ mm" A. NAI (Normandeau Associates, Inc.). 2010a. East Branch Perkiomen Creek Aquatic Biology Assessment XIII, 2008 Monitoring Period. Prepared for Exelon Nuclear, Limerick Generating
______S!§.~.QD.~ay .____ . _~ _ _ .
- B. NAI (Normandeau Associates, Inc.). 2010b. East Branch Perkiomen Creek Aquatic Biology Assessment XIV, 2009 Monitoring Period. Prepared for Exelon Nuclear, Limerick Generating Station.
C. NAI (Normandeau Associates, Inc.). 2010c. Fish and Benthic Macroinvertebrate Community Composition in the Schuylkill River in the Vicinity of Limerick Generating Station During NAI (Normandeau Associates, Inc.). 2010d. Letter from Normandeau Associates, Inc. to Exelon Nuclear via email. Zebra mussel/Asiatic clam Survey. November. PECO (Philadelphia Electric Company). 1984. Environmental Report - Operating License Stage.
Limerick Generating Station Units 1&2. 5 vols.
E. RMC (RMC Environmental Services). 1984. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1979-1983. Prepared for Philadelphia Elect~ic Company. 9...cc,--to_b.:..e:...r_.____~~~~_
- F. RMC (RMC Environmental Services). 1985. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1984. Prepared for Philadelphia mJ~le~!ric ~2..n:!l2§'Qy:J2me(:;~rn..bE?r. _
G. RMC (RMC Environmental Services). 1986. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1985. Prepared for Philadelphia
_.__ Electric
~~~ _ _ _ _- - - '_ _ _L . _ _ ~ __........ _ _ _ _
~ ~~_~~... _ _* _ _~_._~ ......._ _ ~~_m _ _ _ _~_~_ *** mm*
H. RMC (RMC Environmental Services). 1987. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1986. Prepared for Philadelphia Electric Company. November. ________.. . . . _~_m_~_
L RMC (RMC Environmental Services). 1988. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1987. Prepared for Philadelphia r __ . ---=Ec-c'~tric Company. September. _ _ _ _..._
J. RMC (RMC Environmental Services). 1989. Progress Report, Non-Radiological Environmental Monitoring for Limerick Generating Station 1988. Prepared for Philadelphia Electric
~~'-- _ _~ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ m _ _m _ _ _. . _ _ _ m _
K. Describe any aquatic surveys conducted at the Bradshaw Reservoir, the Wadesville Mine Pool and discharge channel, Bedminster Water ProceSSing Facility, and the Still Creek I
Reservoir. For example, submit for docketing the response to information need (AQ-2 from the Audit Information 1\.1;:>,::>,,<:::
L. Describe the frequency that water is withdrawn from the Schuylkill River compared to other sources. For example, submit for docketing the response to information need (AQ-3 from the Audit Information Needs.
I M. Describe the intake velocity, traveling screens, and any other operational procedures or structural designs that limits impingement and entrainment at the Point Pleasant Pumping l ____ Station on the [?ela\l'y'§lre giver QI'~ at the PLJmping stations on the Bradshaw Reservoir,S_t_il_1__
ENCLOSURE 2
2
~-~->'"---
Creek Reservoir, or Wadesville Mine Pool. For example, submit for docketing the response to information need from the Audit N. Describe any impingement or entrainment conducted at the Pumphouse, Perkiomen Pumphouse, or at the intakes on the Delaware River. For example, submit for f--~d~o-,c_kE?!ing the response to information need (AQ-6 from the Audit Information Needs). mm _ _ '
O. Describe the extent of a thermal plume as a result of discharges to the Schuykill River. For example, submit for docketing the response to information need (AQ-7 from the Audit P. In the ER, stated that three species of concern were identified in the Pennsylvania Natural Diversity Index (PNDI) search for LGS license renewal. However, it was unclear which three species LGS identified and where the species would occur on the LGS site and at the Bradshaw Reservoir. Please state these species (AQ-8 from the Audit Information Q. In addition, discuss the potential location the PNDI species concern on the LGS site and at the Bradshaw Reservoir and Pumphouse, as discussed on Page 2-44 of the ER
~ __ 1~9:!Lfr.om thE? AudJUnfo!!:r!~!i()n.J*::J~~(t~L_____ ._. ___.________~ ___ _
___ ___ m m _ n d ___________ ~ H.Y.!i.~~logy ~n~~~ _ _ _ _ ********* ~_ ** _ m '~""_n.~m~_
I A Submit the last 5-years of monthly records for site groundwater production at all four site supply wells with outage periods identified.
2006 H dro eolo ic Investi ations Re ort.
Provide a summary of the results of groundwater monitoring performed for tritium, strontium 90, and gamma-emitting radionuclides since 2006 (i.e., groundwater protection program NPDES permit renewal application for PA0051926 (minus Appendix A and B) and the administrative letter received from PA DEP.
and Cultural Resources A Submit the references called out in Section 2.10 of the ER for archaeological surveys and the architectural and historical analYSis of the Fricks Lock Historic District (CR-2 from the Audit Information Needs). Docketing should follow guidelines from NRC regarding sensitive cultural resources location information. When submitting cultural resources information, do
__~ncluge maps or coordin~tes of site 10cationil'1formation._._~ ___
B. Submit the 1983 letter from the SHPO/PHMC. This letter contains the SHPO findings regarding the determination of impacts to cultural resources from construction and operation of T-lines (CR-3 from the Audit Information Needs). Docketing should follow guidelines from NRC regarding sensitive cultural resources location information. When submitting cultural
. resources inform?tion, do not include maps orc:;oordinates of site locationinformation. _ _
C. Submit the list and description of the type of cultural resources that occur on the LGS site as a result of the CRGIS query (CR-4 from the Audit Information Needs). Docketing should follow guidelines from NRC regarding sensitive cultural resources location information.
When submitting cultural resources information, do not include maps or coordinates of site location information.
D. Submit a summary of the cultural resources management plan to NRC. This summary should contain the table of contents, a brief overview, and a description of how and when the management plan will be implemented (CR-7 from the Audit Information Needs).
Docketing should follow guidelines from NRC regarding sensitive cultural resources location information. When submitting cultural resources information, do not include maps or coordinates of site location information.
'--_~ _ _ _ _ _ _. . ._~. __* _ _ _ _ _ _ _ _ _ _ ~_. __
- _ _ _ . ._ _ _ _ _ _ _ _ _ _ _ m m _ _ _ _. ._ _ . ._ _ __________ ~ _ _ _ _ _ _ _ _. . . . ._ . ____ *
- 3 Terrestrial A. Biodiversity Evaluation of Possum Hollow Run (completed under the direction of Exelon's B.
C. Exelon. 1979-1983. Limerick Generating Station Non-radiological Environmental
.---.~~-~--~ ....._ ,
D. Exelon. 1984. Limerick Generating Station Non-radiological Environmental 1985. Limerick Generating Station Non-radiological Environmental F. 1986. Limerick Generating Station Non-radiological Environmental G. Exelon Generation. 2010. Limerick Generating Station Wildlife Management 086.
H. Wildlife Habitat Council (WHC). 2006. Site Assessment and Wildlife Management o ortunities. 100 pp. LGS-R-278.
In relation to reference WHC (2006) above, please provide the following for the indicated Wildlife at Work Projects:
- a. Bird and bat project summary sheets, including location maps, data sheets, and notes
- b. Frog project summary sheet
- c. Documented Environmental Evaluation Walkdown/Assessment (for frog fence
___. __~._.. replacemenJl(Report AR 01183~9_9..L)~~__~~
.l* J. Submit for docketing the text responses to site audit information needs TE-1, TE-2, TE-3, TE-4, TE-6, TE-7, TE-8, and TE-9. These information needs can be found in NRC's
_~_gIlIJJrgnmental AudiL~-Je_~c!§ List dated Noverl1~~.!_:tL~QJJJ_M!:-Jl~86~3}QL Discussion: The applicant requested that the NRC confirm that, for Hydrology Item D in the table of request for documents, the staff is requesting Exelon to provide the LGS National Pollutant Discharge Elimination System (NPDES) permit renewal application with a copy of Appendix C but not copies of Appendixes A and B. The staff clarified that Exelon does not need to provide a copy of Appendix A, B, or C. The Hydrology Item D in the table of requested documents (reproduced above) has been revised to read as follows:
NPDES permit renewal application for PA0051926 (minus Appendices A, B, and C) and the administrative completeness letter received for PA DEP.
Discussion: The applicant requested that the NRC clarify whether the staff is requesting only excerpts provided at the audit, or the entire reports for Terrestrial Ecology Items C, D, E, and F in the table of requested documents (reproduced above). The staff clarified that only the excerpts provided at the audit are being requested.
April 11, 2012 LICENSEE: Exelon Generation Company, LLC FACILITY: Limerick Generating Station SUB~IECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON FEBRUARY 23, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE LlIVIERICK GENERATING STATION, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Exelon Generation Company, LLC held a telephone conference call on February 23, 2012, to discuss and clarify the staff's requests for additional information (RAls) concerning the Limerick Generating Station license renewal application. The telephone conference call was useful in clarifying the intent of the staff's RAls. provides a listing of the participants and Enclosure 2 contains a listing of the RAls discussed with the applicant, including a brief description on the status of the items.
The applicant had an opportunity to comment on this summary.
IRA!
Leslie Perkins, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353
Enclosures:
As stated cc w/encls: Listserv DISTRIBUTION: See next page ADAMS Accession No.: ML12083A211 *concurred via email R* PM:RPB2:DLR 2:DLR PM:RPB2:DLR NAME IKing LPerkins LPerkins DATE 4/4/12 4/10/12 4/10/12 4/11/12 OFFICIAL RECORD COpy
Memorandum to Exelon Generation Company, LLC, From L, Perkins dated April 11, 2012
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON FEBRUARY 23,2012, BETWEEN THE U,S. NUCLEAR REGULATORY COMMISSION AND EXELON GENERATION COMPANY, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE LIMERICK GENERATING STATION, LICENSE RENEWAL APPLICATION DISTRIBUTION:
HARD COPY:
DLR RF HARD COPY:
DLR RF E-MAIL:
PUBLIC [or NON-PUBLIC, if appropriate]
RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRpob Resource RidsNrrPMLimerick Resource RidsOgcMailCenter Resource RKuntz DMorey LPerkins MSmith,OGC RConte, RI MModes, RI GDiPaolo, RI NSieller, RI