ML12037A180
| ML12037A180 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 08/31/2011 |
| From: | Martin R Office of Nuclear Reactor Regulation |
| To: | Meena Khanna, Clifford Munson, George Wilson Office of New Reactors, Office of Nuclear Reactor Regulation |
| References | |
| FOIA/PA-2011-0357 | |
| Download: ML12037A180 (2) | |
Text
From:
Martin. Robert To:
Munson. Clifford; Khanna. Meena; Wilson. Georoe Cc:
Boyle. Patrick
Subject:
RE: Info Request re: North Anna and Earthquakes Date:
Wednesday, August 31, 2011 2:21:39 PM Also Perry NUREG-0887, Supplement -9, says the Perry EQ exceeded the design spectra at high frequencies for the OBE and the SSE. Etc, etc.
From: Munson, Clifford Sent: Wednesday, August 31, 2011 1:03 PM To: Martin, Robert
Subject:
RE: Info Request re: North Anna and Earthquakes Great thanks.
From: Martin, Robert Sent: Wednesday, August 31, 2011 12:33 PM To: Munson, Clifford; Wilson, George; Karas, Rebecca; Kammerer, Annie; Manoly, Kamal; Kulesa, Gloria; Khanna, Meena; Thomas, George; Chokshi, Nilesh
Subject:
RE: Info Request re: North Anna and Earthquakes ML040970068 (March 29, 2004) says horizontal free field for the San Simeon EQ was.05 so it doesn't look like that came anywhere near Diablo's 3 EQ criteria.
From: Munson, Clifford Sent: Wednesday, August 31, 2011 11:51 AM To: Wilson, George; Karas, Rebecca; Kammerer, Annie; Manoly, Kamal; Martin, Robert; Kulesa, Gloria; Khanna, Meena; Thomas, George; Chokshi, Nilesh
Subject:
RE: Info Request re: North Anna and Earthquakes I spoke with Goutam Bagchi who has been with the NRC for many years and the only OBE exceedance other than Perry and NAnna may have been Diablo Canyon (from the San Simeon earthquake?). We need to check this because I am not sure that it exceeded their OBE. Goutam believes the incident at Fermi was some damage from a tornado and not an earthquake.
Nilesh do you know more details?
Cliff From: Wilson, George Sent: Wednesday, August 31, 2011 11:24 AM To: Karas, Rebecca; Munson, Clifford; Kammerer, Annie; Manoly, Kamal; Martin, Robert; Kulesa, Gloria; Khanna, Meena; Thomas, George
Subject:
FW: Info Request re: North Anna and Earthquakes Importance: High Please assist and gather the data and answer the questions below. What plants have exceeded OBE and What plants have exceeded SSE, this information is needed by COB today. I greatly appreciate your help and support in this issue. Please send the data to me.
From: Bowman, Gregory t/L O Sent:-Wednesday,-August_31,-201 1* 11:01-AM_
To: Wilson, George; Khanna, Meena
Subject:
FW: Info Request re: North Anna and Earthquakes Importance: High George and Meena, Bill Dean (who's acting for Marty this week) sent the e-mail below to Jack and Eric. The Chairman asked that we confirm which plants have experienced earthquakes exceeding the SSE (the e-mail below says OBE - I could be wrong, but I think he meant SSE - if we know both, that would be good for me to pass along, too). I need to share whatever we have with OPA and the Commission offices before the end of the day, so if you can get back to me before then, I would appreciate it.
Greg From: Dean, Bill \\\\..
Sent: Wednesday, August 31, 2011 8:47 AM To: Grobe, Jack; Leeds, Eric Cc: Virgilio, Martin; Bowman, Gregory; Merzke, Daniel
Subject:
Info Request re: North Anna and Earthquakes As we discussed this morning, we need to develop some technically oriented Q and A that can help our public affairs people properly address some of the questions that they are getting. On a nearer term basis, Bill B. just came from the Chairman's office with a question the Chairman would like us to get a straight answer to all the commissioners/OPA" how many sites have exceeded OBE in the past" - I believe it is only Perry, but some are saying FERMI as well. Do we have this information definitively, and if so, can we work with the OEDO staff to get this info walked around to the Commission offices and OPA today? Thanks.
Bill