ML120370531

From kanterella
Jump to navigation Jump to search

Email Correction to the January 4, 2012 SE for Request for Alternative to ASME IWE-5221 Regarding Post-Repair Testing of Steel Containment Vessel Opening
ML120370531
Person / Time
Site: Waterford 
(NPF-038)
Issue date: 01/23/2012
From: Sharon Bennett
Entergy Operations
To: Kalyanam N
Plant Licensing Branch IV
Kalyanam N, NRR/DLPM, 415-1480
Shared Package
ML120370522 List:
References
TAC ME6795
Download: ML120370531 (1)


Text

From:

BENNETT, STEVE A [sbenne2@entergy.com]

Sent:

Monday, January 23, 2012 3:16 PM To:

Kalyanam, Kaly Cc:

STEELMAN, WILLIAM J

Subject:

Correction to NRC Safety Evaluation for Waterford Containment SCV Hatch Repair Attachments:

Page Correction to NRC SE on W-3 IWE-5521.pdf; Notes for Corrections to NRC SE of 1-4-12.doc

Kaly, The NRC issued a Safety Evaluation dated January 4, 2012 for the Waterford ASME Code Alternative to IWE-5521. However, in review of the SE there are several statements that do not represent the Waterford steel containment hatch design or Code Alternative Request. I am providing a markup of the SE pages as well as an explanation of the concerns. Entergy believes that these statements should be revised to allow Entergy to appropriately use the Code relief. Let me know if you have any questions.

Thanks Steve A Bennett Office: 479-858-4683 Cell: 479-970-5875