2011 Dresden Nuclear Power Station Initial License Examination Administrative Outline and Operating Test Comments
ML12030A168
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 03/29/2011
From: Bielby M
Operations Branch III
To:
Exelon Generation Co
Shared Package
ML11104A071 List:
References
Download: ML12030A168 (1)


Text

Operating Test Comments Note: There were no Outline Comments JPM Comments

  • SRO-U,-I,RO AN1R NRC: Not discriminating, only requires simple math. Make one of calculations out of spec that requires some required action or notification.

Licensee: Replaced JPM.

AN2R NRC: Not discriminating, majority of steps identified as critical are not because they are verification steps or reading same voltage of 4160. Replace or rewrite to incorporate problem/action, consequences if not done correctly.

Licensee: Made one voltage OOS, must inform US. First 5 steps are not critical.

AN3R NRC: Change cue to read perform calculation verification and ensure paperwork is correct. On DOS 6600-02, Page 9, initial step 11.c.

Licensee: Comments incorporated.

-5 AN4R NRC: Change Data Sheet 1: Sample Activity Results 9.8x 10 ; Total MPC 22%.

Licensee: Comments incorporated.

AN4S NRC: Change cue to: Complete Dos 1500-08. Add steo #5: Recommends to the US that the calculated sample limit exceeds the allowable discharge.

Licensee: Comments incorporated.

AN1S NRC: Unnecessary cueing in the Initiating Cue. Change Initiating Cue to Determine the reportability requirements.

Licensee: Comment incorporated.

AN2S NRC: Fill in Attachment 4.

Licensee: Comments incorporated.

AN3S NRC: On Initiating Cue, delete and identify any Tech Spec requirements., because it is up the applicant to identify the TS requirements. First 3 steps, change verify to determines. Step 4, remove Condition B.

Licensee: Comments incorporated.

SNA NRC: Not alternate path as written. Procedure directs which RWCU isolation valves to close.

Licensee: Revised to simulate low flow on initial SBLC selected, requires operator to select alternate train in addition to identifying failure of RWCU isolation valves to close.

SNB NRC: 1) Step 1, change green light illuminated to directs NLO to verify closed for 2-1402-6B. 2) Why is closing Flow Test Valve critical (water hammer of future starts?)?

Licensee: 1) Comments incorporated. 2) Yes, water hammer is concern.

SNC NRC: Add step between 9 and 10 to read <setpt ramp>, enter value of ~50 to Reactor Pressure.

Licensee: Comments incorporated.

Scenario Comments Scenario ILT-N-1 NRC:

75%, Earthquake Page 8, Add to roll play, breaker is open Page 11, Add to roll play if asked to quantify leak, I cant tell Page 14, change time compression to 6 inches every 5 minutes Licensee: Comments incorporated.

Scenario ILT-N-3 NRC:

5%, Flood Page 9, change bullets for Circ Water temp and >95 degrees from closed to open. Make if steps.

Page 10, Chang 3.5.1 TS typo from condition G to H.

Page 27, Add when directed by SM to resuming startup.

Licensee: Comments incorporated.