PNNL-20256 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Determining the Best Estimate of Maximum Water Surface Elevation at the Sequoyah Nuclear Plant to Determine the Significance of Tennessee River Watershed's Configuration Modifications and the Impact on Operability SA Breithaupt R Prasad March 2011

PNNL-20256 Determining the Best Estimate of Maximum Water Surface Elevation at the Sequoyah Nuclear Plant to Determine the Significance of Tennessee River Watershed's Configuration Modifications and the Impact on Operability SA Breithaupt R Prasad March 2011 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory Richland, Washington 99352

iii Acronyms and Abbreviations BLN Bellefonte Nuclear Station CEM coastal engineering manual cfs cubic feet per second COLA combined operating license application FL Ft. Loudoun ft feet FSAR Final Safety Analysis Report GIS geographical information system HEC-HMS Hydrologic Engineering Center Hydrologic Modeling System HEC-RAS Hydrologic Engineering Center River Analysis System HMR Hydrometeorological Report in.

inches kcfs thousand cubic feet per second mi miles mi2 square mile mph miles per hour MWSE maximum water surface elevation NRC U.S. Nuclear Regulatory Commission QA quality assurance PMF probable maximum flood PMP probable maximum precipitation PMW probable maximum wind PNNL Pacific Northwest National Laboratory SOCH Simulated Open Channel Hydraulics SQN Sequoyah Nuclear Plant TRM Tennessee River mile TVA Tennessee Valley Authority USACE United States Army Corps of Engineers

v Contents Acronyms and Abbreviations........................................................................................................... iii 1.0 Introduction............................................................................................................................. 1.1 1.1 Task 1.............................................................................................................................. 1.1 1.2 Task 2.............................................................................................................................. 1.2 2.0 Summary of Work Performed................................................................................................. 2.1 2.1 Task 1a............................................................................................................................ 2.1 2.2 Task 1b............................................................................................................................ 2.3 2.3 Task 1c............................................................................................................................ 2.3 2.4 Task 2.............................................................................................................................. 2.8 2.5 PMF Analysis................................................................................................................ 2.10 2.5.1 Modifications Made to the BLN Confirmatory Model...................................... 2.10 2.5.2 PMF Scenarios................................................................................................... 2.15 2.6 Wind-Wave Analysis.................................................................................................... 2.21 3.0 Summary and Conclusions...................................................................................................... 3.1 4.0 References............................................................................................................................... 4.1 Appendix Example Set of Operation Rules from Watts Bar Dam.................................................. A.1

vi Figures 2.1 Tennessee River Watershed Above Guntersville Dam...............................................................

2.2 2.2 Basin-Aggregate Precipitation Depth on the Optimization Set of Subbasins as a Function of Different Centering Locations of the 7,980-mi2 PMP Storm......................................................

2.3 2.3 Sample 9-day or 216-hour Precipitation Event Used as Input in the HEC-HMS Model............

2.4 2.4 HEC-HMS Simulated Discharge Hydrographs at the Outlet of the SQN Basin.........................

2.7 2.5 Site Map with Locations of Dams and the SQN Site..................................................................

2.9 2.6 Rule Curve for Watts Bar Dam as Provided in the TVA White Paper and Compared to the HEC-RAS-Generated Rating Curve Response........................................................................... 2.12 2.7 HEC-RAS Model Rating Curve Responses for Watts Bar and Chickamauga Dams................. 2.13 2.8 Site Map of Chickamauga Reservoir Showing the Locations of the SQN Site, Dallas Bay, and Chickamauga Dam............................................................................................................... 2.14 2.9 Comparison of Rating Curves for the Dallas Bay Overflow from TVA to that Obtained from the HEC-RAS Model.......................................................................................................... 2.15 2.10 Simulated Water-Surface Elevation Response at the Watts Bar and Chickamauga Dams and at the SQN Site............................................................................................................................ 2.19 2.11 Simulated Hydrographs at the Watts Bar and Chickamauga Dams and at the SQN Site........... 2.20 2.12 Maximum PMF Water-Surface Elevation Profile from the HEC-RAS Analysis....................... 2.21 2.13 PNNL Staff Estimated Maximum Wind Fetch for the SQN Site................................................ 2.22 Tables 2.1 Basin-Aggregate 72-Hour Precipitation Depth (in. over the SQN Basin Corresponding to Various PMP Storms in the Tennessee River Watershed...........................................................

2.5 2.2 Selected Locations for Extraction of PMF Discharges for Input to the HEC-RAS Model.........

2.5 2.3 Estimated Peak Discharges below the SQN Site........................................................................

2.6 2.4 Summary of Gate Operational Rules for the Dams Based on the TVA White Paper................. 2.11 2.5 No-Precipitation Loss Model Setup, Characteristic Inputs, and Results for the PNNL Staffs HEC-RAS Model Analysis of the SQN Site............................................................................... 2.17 2.6 With-Precipitation Loss Model Setup, Characteristic Inputs, and Results from the SQN FSAR Analysis and for the HEC-RAS Model Setup for the SQN Site...................................... 2.18 2.7 Flood Operational Rules from TVA for the Mid-March Guides................................................ 2.19 2.8 Comparison of MWSEs at the SQN site for the PMF and Wind-Wave Activity....................... 2.23

1.1 1.0 Introduction During February 2008, the U.S. Nuclear Regulatory Commission (NRC) staff conducted an inspection at the Bellefonte Nuclear Station (BLN) operated by the Tennessee Valley Authority (TVA).

The purpose of the inspection was to verify that quality assurance (QA) processes and procedures were effectively implemented with regard to the Simulated Open Channel Hydraulics (SOCH) model for the BLN combined operating license application (COLA) of Units 3 and 4. The SOCH model was used to calculate the design-basis flood presented in the BLN Safety Analysis Report, Section 2.4.3, "Probable Maximum Flood on Streams and Rivers," and Section 2.4.4, "Potential Dam Failures." However, the verification and validation of the SOCH model and all the design data inputs to the SOCH model, including the supporting FORTRAN programs used as a basis for the BLN COLA, were not available for review.

The NRC staff expressed concern that the significance of the BLN issues on the design basis had not been analyzed at other operating units, one of which is the Sequoyah Nuclear Plant (SQN). NRC staff requested a copy of the BLNs operability/functionality evaluation. The licensee forwarded the original corrective action document (problem evaluation report) and a functionality assessment. The NRC staff identified that the licensee relied on the same QA controls that were not followed at BLN in support of establishing the acceptability of this condition on the operating units.

The NRC staff are assessing whether the changes to the Tennessee River watershed and operation of associated dams have adversely affected the original site flood protection measures for safety-related and important-to-safety structures, systems, and components in the SQN operating units. NRC contracted with Pacific Northwest National Laboratory (PNNL) to assist the NRC staff in determining a best estimate of the maximum water surface elevation (MWSE) at the TVA's SQN site in order to determine the significance of the Tennessee River watershed's configuration modifications and their impact on the operability determination at both units.

For the review of the BLN COLA, PNNL developed a confirmatory model of the Tennessee River (Breithaupt, et al 2010; the BLN study), which focused on the BLN site, but which also included the SQN site. For the analysis of MWSE at the SQN site, PNNL staff use the confirmatory model from the BLN study. Following the methodology described in the BLN study, Tasks 1 and 2 of the SQN analysis are listed below.

1.1 Task 1 This task uses the existing Hydrologic Engineering Center Hydrologic Modeling System (HEC-HMS) model developed for the BLN study to estimate the discharge hydrograph in the TVA basin upstream of the SQN site for the following two scenarios with the evaluation of the results from those scenarios:

a) A 7,980 mi2 optimally placed probable maximum precipitation (PMP) storm that produces the greatest basin aggregate depth of precipitation upstream of the SQN site. Assume precipitation losses of 0 percent and 10 percent.

1.2 b) A 21,400-mi2 optimally placed PMP storm that produces the greatest basin aggregate depth of precipitation upstream of the SQN site. Assume precipitation losses of 0 percent and 10 percent c) Identify and compare the two discharge hydrographs developed in scenarios a) and b) above.

1.2 Task 2 This task uses the existing Hydrologic Engineering Center River Analysis System (HEC-RAS) model developed for the BLN study to estimate the MWSE (probable maximum flood [PMF] plus coincident wind-waves and run-up) at the SQN site.

2.1 2.0 Summary of Work Performed 2.1 Task 1a Three PMP storm patterns are recommended by Hydrometeorological Report (HMR) 41 (WB 1965) for the Tennessee River watershed. HMR 41 recommends that only one of these storms, 7,980 mi2 in size, be moved along its long axis within the watershed. HMR 41 also recommends that another storm, 21,400 mi2 in size, be centered at two places within the Tennessee River watershedthese two locations are called the upstream and downstream centering of the 21,400-mi2 PMP storms, respectively.

Figure 2.1 shows the Tennessee River watershed upstream of the Guntersville Dam, which encompasses the domain of the confirmatory model developed by PNNL for the BLN study. Two sets of subbasins are shownthe first set contains all subbasins outlined in red and the second set contains all subbasins outlined in green. In the BLN study, the location of the 7,980-mi2 PMP storm was optimized such that the basin-aggregate precipitation falling on the first set of subbasins was maximized. The first set of subbasins consists of those that are located upstream of Fort Loudoun and Tellico Dams. The objective in the BLN study was to maximize the precipitation falling in the Tennessee River watershed upstream of Fort Loudoun and Tellico Dams. This assumes the possibility of failure of Ft. Loudoun and Tellico Dams. In the present study, the second set of subbasins is included in the analysis because the objective now is to maximize the basin-aggregate precipitation falling upstream of the SQN site. The two sets of subbasins used in the optimization consist of 30 individual subbasins and are referred to as the optimization set of subbasins for the rest of this report.

HMR 41 recommends that the 7,980-mi2 PMP storm can be moved along its long axis of the Tennessee River basin. In a geographical information system (GIS) analysis, PNNL staff placed the center of the 7,980-mi2 PMP storm at 13 different, equally-spaced positions along the long axis of the storm. For each of the 7,980-mi2 PMP storm centerings, basin-aggregate precipitation depths for all subbasins in the optimization set of subbasins were calculated. The 7,980-mi2 PMP storm centering that resulted in maximum aggregate precipitation over the optimization set of subbasins remained unchanged from that used in the BLN study.

Figure 2.2 shows the effects of moving the 7,980-mi2 PMP storm along its long axis. The plot shows the aggregate precipitation depths on the optimization set of subbasins with the PMP storm centered at the 13 different locations. For the BLN study, it was determined that position 8 was the optimal location for the 7,980-mi2 PMP storm, with a basin-aggregate 72-hour PMP depth of 16.98 in. over the optimization set of subbasins.

The drainage area for estimation the PMF hydrographs at the SQN site consists of 41 subbasins:

those numbered 1-27, 33-43, 44A, 44B, and 45 (see Figure 2.1). This drainage area is referred to as the SQN Basin for the rest of this report. The basin-aggregate precipitation depth over the SQN Basin for the optimized location (position 8) of the 7,980-mi2 PMP storm is determined to be 16.0 in. The corresponding basin-aggregate precipitation depth with a 10-percent precipitation loss is determined to be 14.4 in.

2.2 Figure 2.1. Tennessee River Watershed Above Guntersville Dam. The part of the watershed above SQN includes all subbasins above Chickamauga Dam. The subbasins outlined in red were previously used to optimize the location of the 7,980-mi2 PMP storm for the BLN study. In the present study, the subbasins outlined in green were also used to optimize the location of the 7,980-mi2 PMP storm.

2.3 Figure 2.2. Basin-Aggregate Precipitation Depth on the Optimization Set of Subbasins as a Function of Different Centering Locations of the 7,980-mi2 PMP Storm 2.2 Task 1b Because the recommended location of the 21,400-mi2 PMP storm is fixed at one of two alternate locations, PNNL staff calculated the basin-aggregate precipitation depth using the same GIS analysis approach described above.

For the upstream centering of the 21,400-mi2 PMP storm, the basin-aggregate precipitation depth over the SQN Basin is determined to be 15.4 in., and the corresponding basin-aggregate precipitation depth with a 10-percent loss is determined to be 13.9 in.

For the downstream centering of the 21,400-mi2 PMP storm, the basin-aggregate precipitation depth over the SQN Basin is determined to be 16.4 in., and the corresponding basin-aggregate precipitation depth with a 10-percent loss is determined to be 14.8 in.

2.3 Task 1c PNNL staff used the HEC-HMS model developed for the BLN study to estimate the runoff and discharge hydrographs for the SQN Basin. The input for each subbasin included a 9-day or 216-hour PMP precipitation that includes a sequence of a 3-day storm equivalent to a 40 percent PMP depth, a 3-

2.4 day dry period (no precipitation), and a 3-day PMP storm. A sample 216-hour PMP storm is shown in Figure 2.3.

Figure 2.3. Sample 9-day or 216-hour Precipitation Event Used as Input in the HEC-HMS Model PNNL staff used peaked Snyder unit hydrographs identical to those used in the BLN study as the rainfall-runoff transformation for the subbasins. The analysis used two precipitation loss scenarios. For the first scenario, PNNL staff assumed no rainfall losses. In the HEC-HMS model, PNNL staff implemented this approach by specifying no initial loss and a continuing loss rate of zero inches per hour.

This loss scenario would maximize the runoff from the PMP storm and therefore would result in a higher water-surface elevation in the streams.

For the second scenario, PNNL staff used a 10-percent precipitation loss rate, assuming the loss rate to be uniform across all subbasins in the SQN Basin and an initial precipitation loss of zero. The estimated total rainfall loss for each subbasin was 10-percent of its total PMP depth. Because the HEC-HMS model allows for a precipitation loss only during periods with non-zero rainfall, the loss rate for each subbasin was estimated by equally distributing the total precipitation loss estimated above among all non-zero precipitation time periods.

PNNL staff ran the HEC-HMS model to compute the discharge hydrographs for all subbasins of the SQN Basin for the six scenarios (three PMP storm patterns multiplied by the two precipitation loss

2.5 scenarios) listed in Table 2.1. The model routed tributary hydrographs in the same manner used for the BLN study, that is, by lag-time routing. PNNL staff extracted hydrographs at selected locations within the SQN Basin from the HEC-HMS output for the Task 2 analysis. PNNL staff extracted hydrographs at the locations listed in Table 2.2.

Table 2.1. Basin-Aggregate 72-Hour Precipitation Depth (in.) over the SQN Basin Corresponding to Various PMP Storms in the Tennessee River Watershed Precipitation Loss Scenario 7,980-mi2 PMP Storm 21,400-mi2 Upstream-Centered PMP Storm 21,400-mi2 Downstream-Centered PMP Storm No Loss 16.0 15.4 16.4 10-Percent Loss 14.4 13.9 14.8 Table 2.2. Selected Locations for Extraction of PMF Discharges for Input to the HEC-RAS Model HEC-RAS TRM or River Station HEC-RAS Model (Reach Name)

Subbasin Flow HEC-HMS Model TRM 654.55 TN-R-Loudoun-1 Flow from subbasins 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, and 16 Junction 5 River station (637)

Little River Flow from subbasin 17 Subbasin-17 River station (601)

Tellico River Flow from subbasins 19, 20, 21, 22, and 23 Reach-18 TRM 607.89 and TRM 639.8 TN-R-Loudoun-1 and TN-R-Loudoun-2 Flow from subbasin 18 Subbasin-18 River stations (599.6, 600.2, and 600.6)

Tellico River Flow from subbasin 24 Subbasin-24 TRM 570.05 and TRM 582.96 TN-R-Wattsbar1 Flow from subbasin 25 Subbasin-25 River station (567.2)

Clinch River 1 Flow from subbasins 26, 27, and 33 Reach-38 River station (566.8)

Emory River Flow from subbasin 35 Subbasin-35 River station (566.96)

Clinch River1 Flow from subbasin 34 Subbasin-34 River station (566.56)

Clinch River2 Flow from subbasin 36 Subbasin-36 River stations (533 and 545.2)

White Creek and Piney River Flow from subbasin 37 Subbasin-37 River station (500.5)

Hiwassee Flow from subbasins 38, 39, 40, 41, 42, 43, and 44A Junction 27 River station (500.24)

Hiwassee Flow from subbasin 44B Subbasin-44B TRM (473.05, 485.61, and 512.26)

TN-R-Wattsbar4, TN-R-Chicka2, and TN-R-Chicka3 Flow from subbasin 45 Subbasin-45 TRM = Tennessee River mile Figure 2.4 shows the hydrographs for the six PMP storms and precipitation loss scenarios at the outlet of the SQN Basin (the outlet of subbasin 45, see Figure 2.1 and Table 2.2), which is equivalent to discharge from Chickamauga Reservoir. The SQN site is located approximately 7 mi northeast of this location. Therefore, the discharges near the SQN site would be slightly different from those shown in Figure 2.3. For the purpose of MWSE evaluation, PNNL staff computed the discharges at the SQN site from the HEC-RAS analysis presented in Task 2, which includes the effects of dams and other structures.

2.6 Table 2.3 shows the estimated peak discharges from Task 1 at the outlet of the SQN Basin. The maximum peak discharge of 2,624,376 cfs, among the six scenarios, came from the 21,400-mi2, downstream-centered PMP storm for the no-loss case 190 hours0.0022 days <br />0.0528 hours <br />3.141534e-4 weeks <br />7.2295e-5 months <br /> after the start of the 216-hour PMP storm.

Table 2.3. Estimated HEC-HMS Peak Discharges (cfs) below the SQN Site Precipitation Loss Scenario 7,980-mi2 PMP Storm 21,400-mi2 Upstream-Centered PMP Storm 21,400-mi2 Downstream-Centered PMP Storm No Loss 2,478,135 2,411,360 2,624,376 10-Percent Loss 2,359,363 2,291,909 2,502,431

2.7 Figure 2.4. HEC-HMS Simulated Discharge Hydrographs at the Outlet of the SQN Basin

2.8 2.4 Task 2 The purpose of Task 2 is to estimate the MWSE at the SQN during the PMF. To this end, PNNL staff used the existing HEC-RAS model from the BLN study for the modeling analysis at the SQN site.

The HEC-RAS model includes the following dams on the main Tennessee River (Figure 2.5):

  • Ft. Loudoun
  • Tellico
  • Watts Bar
  • Chickamauga
  • Nickajack
  • Guntersville
  • Wheeler Wheeler Dam and Reservoir were included in the HEC-RAS model to account for tailwater effects that could influence discharge from Guntersville Dam. The SQN site is located on Chickamauga Reservoir approximately 12 mi north of Chattanooga, Tennessee (Figure 2.5). In addition to the dams, other structures included in the HEC-RAS model are the lateral dikes near Tellico and Watts Bar Dams and an overflow from Dallas Bay in Chickamauga Reservoir. The Dallas Bay overflow is included as lateral weir in the HEC-RAS model, though the configuration of the overflow is uncertain.

Task 1 examined the PMP storm patterns with the objective of determining the critical pattern for the SQN site. The 21,400-mi2 downstream PMP storm produced the maximum basin-aggregated depth upstream of the SQN site of 16.4 in. (assuming no-precipitation loss). For the 7,980-mi2-PMP storm, the selection is complicated by the possibility of breaching and failure of dams upstream of the SQN site, including Ft. Loudoun, Tellico, and Watts Bar Dams. Hence, it was necessary to consider the following two centering positions for the 7,980-mi2 PMP storm.

  • Position 8 (at -83.1297degrees latitude and 36.2125 degrees longitude), which produces the greatest PMP depth upstream of Ft. Loudoun-Tellico Dams, with a depth of 16.4 in.
  • Position 6 (at -83.4788 degrees latitude and 36.0447 degrees longitude), which produces the greatest PMP depth upstream of the SQN site, with a depth of 16.0 in.

For Task 1, PNNL staff produced discharge hydrographs from the HEC-HMS hydrologic model using the selected PMP storms. PNNL staff input these hydrographs to the HEC-RAS model. The input hydrographs consists of the antecedent storm, a dry period, and the main PMF storm. For the purposes of the HEC-RAS model analysis, the hydrographs were extended to include a steady inflow before the antecedent storm and after the main PMF storm. The extension prior to the antecedent storm allowed the development of a relatively steady flow (and initial reservoir elevation) in the HEC-RAS model prior to the storm events. The extension after the main PMP storm allowed the system to recover, so that the final

2.9 Figure 2.5. Site Map with Locations of Dams and the SQN Site (labeled as Sequoyah)

Fort Loudoun Tellico Watts Bar Chickamauga Nickajack Guntersville Dam Included in HEC-RAS

2.10 result was used as the restart condition providing smooth initial conditions. Therefore, the startup was a two-step process: 1) generate a restart file using the specified boundary inflows and the coarsely specified initial inflows to produce an initial model run, and 2) use the restart file to specify the initial conditions. This approach produces relatively smooth water-surface gradients and eliminates the spurious variations in flow and elevation that otherwise occur at the outset of the HEC-RAS model analysis stemming from coarsely specified initial conditions.

2.5 PMF Analysis For the PMF analysis of the SQN site, PNNL staff modified HEC-RAS model for the current study based on recommendations from the BLN study, particularly regarding the gate operations during flooding. During the present study for the SQN site, PNNL staff also found that the overflow from Chickamauga Reservoir via the Dallas Bay overflow was an important factor in controlling the MWSE at the SQN site. The following sub-sections discuss the modifications to the HEC-RAS model.

2.5.1 Modifications Made to the BLN Confirmatory Model The confirmatory model developed during the BLN study included simple rules for operation of the dams that either maintained the gates completely open or nearly closed. This approach provided a means of checking the range of possible outcomes at the BLN site, but it did not provide a plausible scenario of the gate operations specified by TVA for actual floods. Consequently, PNNL staff added gate rules to the input data set of the HEC-RAS model for the SQN study.

During the course of the analysis, PNNL staff found that the rating curve of the overflow from Chickamauga Reservoir at Dallas Bay was different in the model from the BLN study than reported in TVA calculation packages. PNNL staff modified the HEC-RAS inputs representing this overflow to reflect the information provided by in the calculation packages.

2.5.1.1 Gate Operational Rules To incorporate dam gate operations (rules) during flooding, PNNL staff obtained the gate operations from the TVA (2008; the White Paper) and the TVA Flood Operational Guides (TVA 2009g) with supplemental data obtained from other available TVA calculation packages, including the following:

  • Ft. Loudoun Dam rating curve (TVA 2009a)
  • Tellico Dam rating curve (TVA 2009b)
  • Watts Bar Dam rating curve (TVA 2009c)
  • Chickamauga Dam rating curve (TVA 2009d)
  • Nickajack Dam rating curve (TVA 2009e)
  • Guntersville Dam rating curve (TVA 2009f)
  • Flood Operational Guides (TVA 2009g)

In addition to a Fixed Rule set, the White Paper also refers to Improved Fixed Rules for operation during flooding; however, those rules were not available in either the White Paper or in the calculation packages provided by TVA. Therefore, the PNNL-staff analysis relies on the Fixed Rules.

2.11 Operational rules generally specify targeted water-surface elevations that are held while the flow is in a specified range. Then as the flood event proceeds, the rules specify how to vary the reservoir elevation up to a specified flow. If the reservoir elevation exceeds the upper limit of the rules, as occurs under the PMF conditions, the rule holds the gates fully open, with the possibility that the dam may be overtopped.

The rules also specify a recovery path to lower the reservoir pool elevation following a flood event; although in this analysis PNNL staff assumed that the recovery rules are encapsulated in the flood response rules. Table 2.4 summarizes the Fixed Rules obtained from the White Paper used in the PNNL staffs analysis.

Table 2.4. Summary of Gate Operational Rules for the Dams Based on the TVA White Paper (TVA 2008). The rules are composed of flow ranges and the target elevations for those ranges.

Ft. Loudoun Dam includes intermediate targets. For the purpose of this analysis, reservoir-recovery following a flood smaller than the PMF is included in the rules. Nickajack Dam is a run-of-the-river reservoir, so the rule is simply to maintain the elevation.

Dam Flow Ranges and Target Elevations Pre-Flood Intermediate Rising Limb of Flood Post Flood Ft. Loudoun

<50 kcfs 807 ft

>50 kcfs and <60 kcfs 810 ft

>60 kcfs 815 ft After maximum PMF 807 ft Tellico

<390 kcfs at FL Gates fully closed NA

>390 kcfs at FL Gates fully open

>390 kcfs at FL Gates fully open Watts Bar

<110 kcfs 735 ft NA

>110 kcfs 745 ft After maximum PMF 735 ft Chickamauga

<155 kcfs 675 ft NA

>155 kcfs 685.44 ft After maximum PMF 675 ft Nickajack 632.5 ft 632.5 ft 632.5 ft 632.5 ft Guntersville

<225 kcfs 593 ft NA

>225 kcfs 595.44 ft After maximum PMF 593 ft FL = Ft. Loudoun; NA = Not available.

Appendix A provides an example set of operational rules used in the HEC-RAS analysis for Watts Bar Dam. For the HEC-RAS analysis, the rules define the gate operations (opening or closing) prior to and after the maximum elevation for the PMF event. This approach simplified the inclusion of recovery of the reservoir following the main flood event. Figure 2.6 shows an example rule curve from the White Paper for Watts Bar Dam, with a comparison of the headwater-discharge rating curve from the HEC-RAS model. In general, there is good agreement between the curves. Note that the TVA rule curve is a specification, and not output from the analysis documented in the SQN Final Safety Analysis Report (FSAR), while the HEC-RAS model uses the specifications given in Table 2.4 and produces the output seen in Figure 2.6.

Figure 2.7 shows the headwater and tailwater rating curves for Watts Bar and Chickamauga Dams from the HEC-RAS analysis. The headwater rating curve for Chickamauga Dam shows a loop at the higher flows indicating the tailwater elevations affect the discharge from the dam and the consequently the water-surface elevations upstream of the dam. Watts Bar Dam does not show a similar looped headwater rating curve, indicating that tailwater elevations do not affect the discharge.

2.12 TVA White Paper Rule Curve HEC-RAS Rating Curve Response Figure 2.6. Rule Curve for Watts Bar Dam as Provided in the TVA White Paper (TVA 2008) and Compared to the HEC-RAS-Generated Rating Curve Response 734 736 738 740 742 744 746 748 0

100000 200000 300000 400000 500000 600000 700000 Elevation (ft)

Discharge (cfs)

2.13 Watts Bar Dam Chickamauga Dam Figure 2.7. HEC-RAS Model Rating Curve Responses for Watts Bar and Chickamauga Dams. The plots illustrate whether there is an effect from the tailwater on headwater discharge, which produces a loop-rating curve. No effect on headwater discharge occurs for Watts Bar Dam, while Chickamauga Dam does show an interaction especially at the largest flows.

670 680 690 700 710 720 730 740 750 760 770 0

200000 400000 600000 800000 1000000 1200000 1400000 Elevation (ft)

Discharge (cfs)

Headwater Tailwater 630 640 650 660 670 680 690 700 710 720 730 0

200000 400000 600000 800000 1000000 1200000 1400000 Elevation (ft)

Discharge (cfs)

Headwater Tailwater

2.14 2.5.1.2 Dallas Bay Overflow Rating Curve Dallas Bay is located on Chickamauga Reservoir approximately 4 mi downstream of the SQN site.

According to the TVA (2009d), the minimum elevation for the Dallas Bay rating curves is 698 ft. When water-surface elevations exceed this minimum value, Dallas Bay will overflow into the Lick Branch and the North Fork Chickamauga Creek (Figure 2.8). During an overflow event from Dallas Bay, the overflow discharge joins the main river downstream of Chickamauga Dam at the confluence of the North Fork Chickamauga Creek and the Tennessee River.

TVA (2009d) provides a cross section of the Dallas Bay overflow and the headwater-discharge curve.

PNNL staff incorporated the TVA cross section into the HEC-RAS model by using it to define a lateral weir that represents the overflow configuration. To match the headwater-discharge curve reported by TVA (2009d), PNNL staff adjusted the lateral weir coefficient (Cd), determined that a value of 0.7 provided the closest match (Figure 2.9), and used this value for all subsequent analyses. Because of the close proximity of the Dallas Bay overflow section to the SQN site, the characteristic of the overflow could produce a pronounced effect on MWSE at the SQN site.

Figure 2.8. Site Map of Chickamauga Reservoir Showing the Locations of the SQN Site, Dallas Bay, and Chickamauga Dam

2.15 Figure 2.9. Comparison of Rating Curves for the Dallas Bay Overflow from TVA (2009d) to that Obtained from the HEC-RAS Model. A discharge coefficient of 0.7 for the HEC-RAS lateral weir representing the overflow structure was found to provide a reasonable agreement with the TVA rating curve data.

2.5.2 PMF Scenarios PNNL staff examined several scenarios during the PMF analysis at the SQN site including the following:

  • 7,980-mi2-PMP storm versus 21,400-mi2-PMP storm
  • No-precipitation loss versus 10-percent global precipitation loss
  • Recent dam safety modifications (no sandbaskets versus with sandbaskets)

The first comparison comes from the Task 1 results. The second comparison is included because the SQN FSAR reports an average 11 percent precipitation loss. The third comparison is included to consider the recent safety modifications to Ft. Loudoun, Tellico, and Watts Bar Dams.

For these scenarios, the potential for dam failure was included only for dams upstream of the SQN site, that is, Ft. Loudoun, Tellico, and Watts Bar Dams. At downstream dams, Chickamauga, Nickajack, and Guntersville Dams were set not to fail when overtopped, which would produce greater backwater effects than if failure occurred. This approach provides a conservative estimate of PMF water-surface elevation at the SQN site.

0 50000 100000 150000 200000 250000 300000 670 680 690 700 710 720 730 Discharge from Dallas Bay (cfs)

Headwater Elevation (ft)

TVA Rating Curve HEC-RAS Cd=0.7

2.16 Table 2.5 and Table 2.6 provide the HEC-RAS model setup, inputs, and results for MWSE and discharge, as available from the SQN FSAR analysis and from the staffs HEC-RAS model setup.

Table 2.5 provides information for the no-precipitation-loss scenarios, while Table 2.6 provides information for precipitation-loss scenarios.

The SQN FSAR states that the 21,400-mi2 downstream pattern was critical for the analysis of the PMF at the SQN site. The SQN FSAR also states that the Ft. Loudoun, Tellico, and Watts Bar Dams would safely pass the PMF, suggesting that these dams did not overtop and fail in the SQN FSAR analysis. The corresponding scenario that PNNL staff compared with the SQN FSAR results is the 21,400-mi2 downstream pattern, 10-percent global precipitation loss, and no sandbaskets (corresponding to Table 2.6, column 5). This scenario was chosen for its similarity to the FSAR analysis.

Table 2.6 indicates that the PNNL staffs HEC-RAS analysis produced a failure of Tellico Dam during the main PMF, while the SQN FSAR analysis apparently did not include failure of any of the dams. The PNNL staffs analysis produced a maximum discharge at the SQN site of 1,466,769 cfs, which is larger than the 1,236,000 cfs reported in the SQN FSAR. However, the maximum elevation at the SQN site from the PNNL staffs HEC-RAS analysis was 718.08 ft compared with the reported SQN FSAR result of 719.6 ft. The PNNL staffs analysis had a flow concurrent with the maximum elevation of 1,444,553 cfs. The maximum flow occurred prior to the MWSE due to the dynamic properties of the flood wave, which produces a looped rating curve during flooding (NOAA 1998). As an additional comparison, the corresponding no-precipitation-loss scenario for the 21,400-mi2 downstream-centered PMP storm with no sandbaskets (Table 2.5, column 5) produced a maximum PMF discharge of 1,851,597 cfs and a maximum elevation of 722.64 ft.

Because of the uncertainty about the actual operational rules used in the FSAR analysis, PNNL staff examined an alternative operational guide set (TVA 2009g) that uses slightly different target elevations and ranges of discharges to evaluate the sensitivity to operations. Table 2.7 summarizes the rules. This alternative rule set includes an additional intermediate rule for Chickamauga Dam. Use of this alternative rule set produced a maximum elevation of 718.18 ft (with a concurrent flow of 1,447,585 cfs) and a maximum flow of 1,469,177 cfs. This is slightly larger than estimated using the White Paper operational guide, which was 718.08 ft. The alternative rule set produced a failure of Tellico Dam but not of any other dams. Hence, the HEC-RAS model appears to be somewhat insensitive to the operational rules, at least within the set of available operational rules.

Figure 2.10 presents the water-surface elevation response for the whole analysis period (antecedent and PMF) at the Watts Bar and Chickamauga Dams and the SQN site (HEC-RAS station 485.61) for the 10-percent precipitation-loss scenarios. The Watts Bar and Chickamauga Dams are upstream and downstream of the SQN site, respectively. All the locations in Figure 2.10 responded to the PMF in a similar manner due to the very high discharges during the event, with the water-surface elevations exceeding the tops of the gates and overtopping portions of the dams. At Watts Bar Dam, the water-surface response during the antecedent storm is simply an increase to 745 ft, which is held until the PMF produces the large increases in the water-surface elevation. In contrast, the water surface at Chickamauga Dam shows a response to the antecedent storm that PNNL staff attribute to the influence of the tailwater on discharge. The water-surface elevations are slightly higher at the SQN site than at Chickamauga Dam and have a relatively smooth variation during the analysis period.

2.17 Table 2.5. No-Precipitation Loss Model Setup, Characteristic Inputs, and Results for the PNNL Staffs HEC-RAS Model Analysis of the SQN Site. Note there was no analysis reported in the SQN FSAR with a zero precipitation loss. The shaded column indicates that scenario is compared to those in Table 2.6.

Source of Analysis Scenarios (1)

(2)

(3)

(4)

(5)

SQN FSAR PNNL PNNL PNNL PNNL Dam Safety Measures SQN FSAR has no analysis available with no-precipitation loss Sandbaskets(a)

Sandbaskets(a)

No sandbaskets(a)

No sandbaskets(a)

Date of Analysis October 2010 October 2010 October 2010 October 2010 Critical Storm Pattern 7,980 mi2 position 6 21,400 mi2 downstream 7,980 mi2 position 6 &8(b) 21,400 mi2 downstream Configuration of Dallas Bay Overflow to Lick Branch TVA Calculation Package 0006 TVA Calculation Package 0006 TVA Calculation Package 0006 TVA Calculation Package 0006 Gate Discharge Coefficient 3.0/0.8 3.0/0.8 3.0/0.8 3.0/0.8 Dams Breached None None Ft. Loudoun (positions 6 & 8)

Tellico Ft. Loudoun(c)

Watts Bar Maximum PMF Flow at SQN 1,408,621 cfs 1,577,763 cfs 1,531,474 cfs/

1,470,536 cfs 1,851,597 cfs Maximum PMF Elevation at SQN(d) 717.50 ft 719.70 ft 719.04 ft/718.24 ft 722.64 ft (a) Sandbaskets installed during 2009 on earthen embankments of Ft. Loudoun, Tellico, and Watts Bar Dams.

(b) Position 8 was included for the 7,980-mi2 case in which one of the upstream dams breaches, because it includes greater precipitation upstream of the Ft.

Loudoun-Tellico Dams than for the position 6 case.

(c) Breach formation time set to 1.15 hour1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> for model stability. Other dams were set to a 1-hour breach formation time.

(d) Elevation at the cross section located just upstream of the SQN site at station 485.61.

2.18 Table 2.6 With-Precipitation Loss Model Setup, Characteristic Inputs, and Results from the SQN FSAR Analysis and for the HEC-RAS Model Setup for the SQN Site. Shaded columns indicate which scenarios are compared with the one in Table 2.5. The wind-wave effects on maximum elevation are included from the SQN FSAR analysis and the HEC-RAS model.

Source of Analysis Scenarios (1)

(2)

(3)

(4)

(5)

SQN FSAR PNNL PNNL PNNL PNNL Dam Safety Measures Prior to 2008 Sandbaskets(a)

Sandbaskets(a)

No sandbaskets(a)

No sandbaskets(a)

Date of Analysis Prior to 2008 October 2010 October 2010 October 2010 October 2010 Critical Storm Pattern 21,400 mi2 downstream 7,980 mi2 position 6 21,400 mi2 downstream 7,980 mi2 position 6 21,400 mi2 downstream Configuration of Dallas Bay Overflow to Lick Branch Unknown TVA Calculation Package 0006 TVA Calculation Package 0006 TVA Calculation Package 0006 TVA Calculation Package 0006 Gate Discharge Coefficient Unknown 3.0/0.8 3.0/0.8 3.0/0.8 3.0/0.8 Precipitation Losses 11 percent 10 percent global 10 percent global 10 percent global 10 percent global Dams Breached None None None None Tellico Maximum PMF Flow at SQN 1,236,000 cfs 1,321,763 cfs 1,416,729 cfs 1,321,763 cfs 1,466,769 cfs Maximum PMF Elevation at SQN 719.6 ft 716.12 ft(b) 717.46 ft(b) 716.12 ft(b) 718.08 ft(b)

(a) Sandbaskets installed on earthen embankments of Ft. Loudoun, Tellico, and Watts Bar Dams (2009).

(b) Elevation at the cross section located just upstream of the SQN site at station 485.61.

2.19 Table 2.7. Flood Operational Rules from TVA (2009g) for the Mid-March Guides Dam Flow Ranges and Target Elevations Pre-Flood Intermediate Rising Limb of Flood Post-Flood Ft. Loudoun

<50 kcfs 808 ft

>50 kcfs and <98.75 kcfs 813 ft

>98.75 kcfs 817 ft After maximum PMF 808 ft Tellico

<815 ft 0 kcfs

>815 ft and <817 30 kcfs

>817 Gates fully open After maximum PMF 815 ft Watts Bar

<45 kcfs 736 ft

>45 kcfs and <80 kcfs 741 ft

>80 kcfs 747 ft After maximum PMF 736 ft Chickamauga

<45 kcfs 676 ft (1) >45 kcfs and <85 kcfs 679 ft (2) >85 kcfs and <145 kcfs 685.44 ft

>145 kcfs 687 ft After maximum PMF 676 ft Nickajack 632.5 ft 632.5 ft 632.5 ft 632.5 ft Guntersville

<50 kcfs 593.3 ft

>50 kcfs and <200 kcfs 595.35 ft

>200 kcfs 596 ft After maximum PMF 593.3 ft Figure 2.10. Simulated Water-Surface Elevation Response at the Watts Bar and Chickamauga Dams and at the SQN Site. Results are from the HEC-RAS scenario for the 21,400-mi2 downstream pattern, 10-percent precipitation loss, and no sandbaskets (Scenario 5 of Table 2.6).

660 680 700 720 740 760 780 3/1 3/8 3/15 3/22 3/29 Elevation (ft)

Date Watts Bar Dam Chickamauga Dam SQN Site

2.20 Figure 2.11 presents the hydrographs for the whole analysis period (antecedent and PMF) at the Watts Bar and Chickamauga Dams and the SQN site (HEC-RAS station 485.61) for the 10-percent precipitation-loss scenarios. During the PMF period, the SQN station has the greatest discharge because it received additional flow entering Chickamauga Reservoir downstream of Watts Bar Dam and the loss of flow via Dallas Bay occurred downstream of the SQN station and upstream of Chickamauga Dam.

Rapid changes in gate openings following the antecedent and PMF events caused the transient variations in discharge following the antecedent and PMF periods. For Watts Bar Dam, the spike in flow during the antecedent event occurred because of the holding of water until the water-surface elevation reached 745 ft, after which the gates rapidly opened. For Chickamauga Dam, PNNL staff attributed the drop in flow during the antecedent storm to the influence of the tailwater on discharge.

Figure 2.11.

Simulated Hydrographs at the Watts Bar and Chickamauga Dams and at the SQN Site.

Results are from the HEC-RAS scenario for the 21,400-mi2 downstream pattern, 10-percent precipitation loss, and no sandbaskets (Scenario 5 of Table 2.6). Note the maximum discharge at the SQN site is greater than at the Watts Bar and Chickamauga Dams because of additional inflows upstream of the SQN site and outflow from Dallas Bay downstream of the SQN site. Transient shocks in the flow following the antecedent and PMF periods are due to rapid changes in the gate openings.

Figure 2.12 presents the MWSE profile for the PMF with the locations indicated for the main dams along the Tennessee River, Dallas Bay, and the SQN site. The tailwater effect at Chickamauga Dam appears as a relatively small change in elevation from upstream to downstream of the dam. (Dams downstream of Chickamauga Dam also had tailwater effects on discharge.)

0 200000 400000 600000 800000 1000000 1200000 1400000 1600000 3/1 3/8 3/15 3/22 3/29 Flow (cfs)

Date Watts Bar Dam Chickamauga Dam SQN Site

2.21 Figure 2.12.

Maximum PMF Water-Surface Elevation Profile from the HEC-RAS Analysis. Results are from the HEC-RAS scenario for the 21,400-mi2 downstream pattern, 10-percent precipitation loss, and no sandbaskets (Scenario 5 of Table 2.6).

2.6 Wind-Wave Analysis PNNL staff estimated wind-wave activity at the SQN site by combining the PMF stillwater elevation with the estimated effect of the probable maximum wind (PMW). An important input for this analysis is the maximum fetch length along which the wind blows towards the site (Figure 2.13). The SQN FSAR reports the maximum fetch as 1.7 mi; however, Figure 2.13 shows that the fetch distance along a similar line is 4.1 mi. This is an apparent error in measurement of the fetch length in the SQN FSAR. The SQN FSAR reports that the estimated increase in MWSE due to wind-wave activity is 2.8 ft. Therefore, the combined PMF and wind-wave induced water-surface elevation is 722.4 ft.

PNNL staff conducted a wind-wave analysis based on the U.S. Army Corps of Engineers (USACEs) coastal engineering manual (CEM) using the CEM 2.0 PE software (USACE 2006) and the PNNL-staff-determined values of the fetch length and wind speed. PNNL staff estimated a 2-year wind speed of 50 mph based on guidance provided by the American Nuclear Society (ANS 1992). Using the 4.1-mi fetch, PNNL staff computed the wave runup to be 2.71 ft, and the wave setup to be 0.08 ft, for a total increase of 2.79 ft. Combined with the PMF stillwater elevation of 718.08 ft from the PNNL staffs PMF scenario most similar to the SQN FSAR scenario, the PMW produces a maximum elevation of 720.87 ft (Table 2.8). For the no-precipitation-loss scenario, the maximum elevation including wind-wave effects is 725.5 ft (Table 2.8).

0 100 200 300 400 400 500 600 700 800 900 Main Channel Distance (mi)

Elevation (ft)

Legend WS Max WS Ground Ft. Loudoun Dam Chickamauga Dam Watts Bar Dam Dallas Bay Nickajack Dam Guntersville Dam Sequoyah Nuclear Plant

2.22 Figure 2.13. PNNL Staff Estimated Maximum Wind Fetch for the SQN Site

2.23 Table 2.8. Comparison of MWSEs at the SQN site for the PMF and Wind-Wave Activity Analysis Source of Analysis SQN FSAR PNNL Staff PNNL Staff Precipitation Loss 11 percent (average) 0 percent 10 percent (global)

Maximum PMF Elevation 719.6 ft 722.64 ft 718.08 ft Maximum Elevation Including Wind-Wave Activity 722.4 ft 725.5 ft 720.9 ft

3.1 3.0 Summary and Conclusions The Task 1 analysis determined that the 21,400-mi2 downstream centered PMP storm was the critical pattern for the SQN site. For the 7,980-mi2 PMP storm pattern, both the positions 6 and 8 were found to be critical depending on the assumption of upstream dam failure. Assuming the failure of Ft. Loudoun and Tellico Dams, position 8 (-83.1297degrees latitude and 36.2125 degrees longitude) was the critical 7,980-mi2-PMP storm; while with no dam failure position 6 (-83.4788 degrees latitude and 36.0447 degrees longitude) was the critical 7,980-mi2-PMP storm. Discharge hydrographs for the three patterns were produced for each of the precipitation-loss scenarios (zero loss and 10-percent loss) giving six sets of hydrographs.

The Task 2 analysis used the HEC-RAS model previously developed for BLN study. The Task 2 analysis approach was to make a comparison using a model setup similar to that used by the TVA in the SQN FSAR, though other scenarios examined include the recent dam safety modifications and no-precipitation loss. PNNL staff modified the previously developed HEC-RAS model from the BLN study to account for operational rules at the TVA dams. During the course of the analysis, PNNL staff found that the influence of overflow from Dallas Bay in Chickamauga Reservoir on water levels at the SQN site was significant. Consequently, the available cross section and rating curve representing the Dallas Bay overflow section were included in the HEC-RAS model.

PNNL staff examined several scenarios that considered safety modifications made to the dams in 2009, in which TVA installed sandbaskets on earthen embankment portions of three dams (Ft. Loudoun, Tellico, and Watts Bar). The scenarios also considered precipitation losses and the PMP storm, with the discharge hydrographs obtained from Task 1. The primary scenario that PNNL staff used for comparison with the SQN FSAR results is the one for the 21,400-mi2 downstream pattern, a 10-percent global precipitation loss, and no sandbaskets. PNNL staff also considered the corresponding scenario with no-precipitation loss to evaluate a more conservative assumption of runoff generation. Wind-wave effects on PMF stillwater elevation were also estimated.

PNNL staff found in their analysis that the maximum PMF stillwater elevations were as follows:

10-percent precipitation loss = 718.1 ft no-precipitation loss = 722.6 ft The SQN FSAR reported a maximum PMF elevation of 719.6 ft.

Including the wind-wind effects on the maximum elevation, PNNL staff findings were as follows:

10-percent precipitation loss = 720.9 ft no-precipitation loss = 725.5 ft The SQN FSAR reported a maximum elevation of 722.4 ft.

4.1 4.0 References American Nuclear Society (ANS). 1992. Determining Design Basis Flooding at Power Reactor Sites -

An American National Standard. ANS/ANSI-2.8-1992. La Grange Park, Illinois.

Breithaupt, S., R. Prasad, J. Staeheli, C. Lee, T. Kim, and R. Labiosa. 2010. Bellefonte Units 3 and 4, Development of Confirmatory Model of the Tennessee River. PNNL-19698. Pacific Northwest National Laboratory, Richland, Washington.

U.S. Department of Commerce, Weather Bureau. (WB). 1965. Hydrometeorological Report (HMR) No.

41, Probable Maximum and TVA Precipitation over the Tennessee River Basin above Chattanooga.

Washington, DC.

National Oceanic and Atmospheric Administration (NOAA). 1998. Enhancements of River Forecasts Using Dynamic Hydraulic Flow Routing. Accessed November 19, 2010.

http://www.nws.noaa.gov/oh/hrl/papers/ams/ams98-5.htm.

Tennessee Valley Authority (TVA). 2008. Bellefonte Nuclear Plant White Paper - Hydrologic Analysis, Revision I. July 25, 2008. Nuclear Regulatory Commission Accession Number ML0821101451.

Tennessee Valley Authority (TVA). 2009a. Bellefonte Nuclear Plant, Ft. Loudoun Dam Rating Curve.

Calculation Package CDQ000020080009, Revision 0.

Tennessee Valley Authority (TVA). 2009b. Bellefonte Nuclear Plant, Tellico Dam Rating Curve.

Calculation Package CDQ000020080018, Revision 0.

Tennessee Valley Authority (TVA). 2009c. Bellefonte Nuclear Plant, Watts Bar Dam Rating Curve.

Calculation Package CDQ000020080020, Revision 0.

Tennessee Valley Authority (TVA). 2009d. Bellefonte Nuclear Plant, Chickamauga Dam Rating Curve.

Calculation Package CDQ000020080006, Revision 0.

Tennessee Valley Authority (TVA). 2009e. Bellefonte Nuclear Plant, Nickajack Dam Rating Curve.

Calculation Package CDQ000020080014, Revision 0.

Tennessee Valley Authority (TVA). 2009f. Bellefonte Nuclear Plant, Guntersville Dam Rating Curve.

Calculation Package CDQ000020080011, Revision 0.

Tennessee Valley Authority (TVA). 2009g. Bellefonte Nuclear Plant, Flood Operational Guides.

Calculation Package CDQ000020080050, Revision 0.

U.S. Army Corps of Engineers (USACE). 2006. U.S. Army Corps of Engineers Coastal Engineering Manual, Engineering Manual 1110-2-1100 (Part II). Vicksburg, Mississippi.

Appendix Example Set of Operation Rules from Watts Bar Dam

A.1 Appendix Example Set of Operation Rules from Watts Bar Dam A.1 Definitions:

'Current Simulation Hour' = Hour of Simulation (at beginning of the each time step)

'Current Watts Bar Elevation' = Water Surface Elevation (at station 530.06 upstream of Watts Bar Dam at the current time step)

'Current Watts Bar Gate Opening' = Dam Gate Opening (at station 530, Watts Bar Dam station, at the current time step)

'Current Flow' = River Flow (at station 530.06 upstream of Watts Bar Dam at the current time step)

A.2 Rule Set (called for each time step of the simulation):

If ('Current Simulation Hour' 354, the hour of the PMF maximum at Watts Bar Dam), then If ('Current Flow' < 110,000 cfs) And ('Current Watts Bar Elev' < 736 ft) Then If ('Current Watts Bar Elevation' 735 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' - 0.1 ft Else If (' Current Watts Bar Elevation ' > 735 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' + 0.1 ft End If Else If ('Current Flow' > 110,000 cfs) Then If ('Current Watts Bar Elevation' 745 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' - 0.1 ft Else If ('Current Watts Bar Elevation' > 745 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' + 0.1 ft End If End If If ('Current Simulation Hour' > 354, the hour of the PMF maximum at Watts Bar Dam) Then If ('Current Watts Bar Elevation' 735 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' - 0.5 ft (an incremental change of 0.5 ft is used to reduce an undershoot)

Else If ('Current Watts Bar Elevation' > 735 ft) Then Gate Opening = 'Current Watts Bar Gate Opening' + 0.5 ft (an incremental change of 0.5 ft is used to reduce an undershoot)

End If End If