Lr Hearing - Teleconference Summary from Call Held January 12, 2012 Re Indian Point License Renewal Application
ML12020A081
Person / Time
Site: Indian Point  
Issue date: 01/20/2012
From:
Office of Nuclear Reactor Regulation
To:
Division of License Renewal
References
Download: ML12020A081 (7)


Text

1 IPRenewal NPEmails From:

Kuntz, Robert Sent:

Friday, January 20, 2012 10:09 AM To:

rwalpol@entergy.com Cc:

IPRenewal NPEmails

Subject:

Teleconference summary from call held January 12, 2012 RE Indian Point License Renewal Application Attachments:

Telecon Summary 1-12-12 RVI.docx

Bob, Attached is a teleconference summary from the call held January 12, 2012 pertaining to the Indian Point license renewal application. This is being forwarded to you to ensure that the comments attributed to Entergy have been properly captured. If Entergy would like to provide comments on the attached please do so by January 25, 2012.

Robert Kuntz Sr. Project Manager NRR/ADRO/DLR/RPB1 (301) 415-3733 robert.kuntz@nrc.gov

Hearing Identifier:

IndianPointUnits2and3NonPublic_EX Email Number:

3220 Mail Envelope Properties (94A2A4408AC65F42AC084527534CF41673EFBD0C90)

Subject:

Teleconference summary from call held January 12, 2012 RE Indian Point License Renewal Application Sent Date:

1/20/2012 10:09:14 AM Received Date:

1/20/2012 10:09:16 AM From:

Kuntz, Robert Created By:

Robert.Kuntz@nrc.gov Recipients:

"IPRenewal NPEmails" <IPRenewal.NPEmails@nrc.gov>

Tracking Status: None "rwalpol@entergy.com" <rwalpol@entergy.com>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 463 1/20/2012 10:09:16 AM Telecon Summary 1-12-12 RVI.docx 30242 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

LICENSEE:

Entergy Nuclear Operations, Inc.

FACILITY:

Indian Point Nuclear Generating Station, Units 2 and 3

SUBJECT:

SUMMARY

OF CONFERENCE CALL HELD ON JANUARY 12, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING THE REACTOR VESSEL INTERNALS PROGRAM AT INDIAN POINT NUCLEAR GENERATING STATION, UNITS 2 AND 3 Representatives of the U.S. Nuclear Regulatory Commission (NRC or the staff), and representatives of Entergy Nuclear Operations, Inc., (Entergy or the applicant), held a conference call on January 12, 2012, to discuss the applicants aging management activities for the reactor vessel internals (RVI) at Indian Point (IP) Nuclear Generating Station, Units 2 and 3.

These activities consist of the RVI Program, which was submitted to the NRC as part of License Renewal Application Amendment 9 by letter dated July 14, 2010, and the RVI Inspection Plan, which was submitted to the NRC by letter dated September 28, 2011.

By letter dated August 22, 2011, the applicant stated, Following issuance of MRP-227-A, Entergy will review the inspection plan to determine the need for revision, and will modify the inspection plan to include the necessary revisions, if any. MRP-227-A was issued by the Electric Power Research Institute (EPRI) in December 2011. Therefore, the staff inquired if the applicant was aware that MRP-227-A was issued, whether the applicant had reviewed MRP-227-A, and when the applicant planned to address any differences between MRP-227-A and IPs RVI Program and RVI Inspection Plan. The applicant indicated that it was in the process of reviewing MRP-227-A and would notify the staff of its plan and schedule to address any necessary revisions to its RVI Program and RVI Inspection Plan based on the issuance of MRP-227-A. With respect to two plant-specific action items for which the information was not provided in the IP RVI Inspection Plan, both of which require plant specific acceptance criteria or analyses for particular components, the applicant indicated that the Pressurized Water Reactor Owners Group (PWROG) is in the process of developing generic guidance for developing the criteria or analyses for these items, and that Entergy would defer providing the response for these items until the PWROG completes its generic work.

Subsequent to the teleconference, Entergy contacted the IP license renewal project manager and indicated that Entergy would submit a letter by February 27, 2012, that would provide necessary revisions to the IP RVI Program and RVI Inspection Plan based on the issuance of MRP-227-A.

The applicant had an opportunity to comment on this summary.

Robert F. Kuntz, Sr. Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286

Enclosure:

List of Participants cc w/encl: Listserv

ML11215A056

  • concurrence via e-mail OFFICE LA: DLR/RPB1*

PM: DLR/RPB1 BC: RPB1:DLR LA: DLR/RPB1 PM: DLR/RPB1 NAME RKuntz DMorey RKuntz DATE Letter to Entergy Nuclear Operations, Inc. from Robert F. Kuntz dated January XX, 2012

SUBJECT:

SUMMARY

OF CONFERENCE CALL HELD ON JANUARY 12, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING THE REACTOR VESSEL INTERNALS PROGRAM AT INDIAN POINT NUCLEAR GENERATING STATION, UNITS 2 AND 3 DISTRIBUTION:

HARD COPY:

DLR R/F E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDraAfpb Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource AStuyvenberg GMeyer, RI RAuluck RConte, RI BPham JBoska DPelton DScrenci, RI OPA MKowal NSheehan, RI OPA DJackson, RI PCataldo, RI BMizuno, OGC NMcNamara, RI STurk, OGC BWelling, RI SBurnell, OPA OAvegbusi, RI DMcIntyre, OPA MCatts, RI EDacus, OCA MHalter, RI

ENCLOSURE TELEPHONE CONFERENCE CALL INDIAN POINT NUCLEAR GENERATING STATION, UNIT NUMBERS 2 AND 3 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS JANUARY 12, 2012 PARTICIPANTS:

AFFILIATIONS:

Robert F. Kuntz U.S. Nuclear Regulatory Commission (NRC)

Bo Pham NRC Allen Hiser NRC Jeffery Poehler NRC Alan Cox Entergy Nuclear Operations, Inc. (Entergy)

Bob Walpole Entergy Roger Waters Entergy John Curry Entergy Nelson Azevedo Entergy Bob Dolansky Entergy