UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 18, 2012 Mr. Barry S. Allen Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Mail Stop A-DB-3080 5501 North State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO.1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING NOTIFICATION OF SIGNIFICANT CHANGE TO SMALL-BREAK LOSS-OF-COOLANT ACCIDENT EMERGENCY CORE COOLING MODEL IN ACCORDANCE WITH 10 CFR 50.46(a)(3)
Dear Mr. Allen:
By letter dated May 27,2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML111510642), FirstEnergy Nuclear Operating Company (FENOC),
submitted a notification of a significant change to the small-break loss-of-coolant accident emergency core cooling model in accordance with paragraph 50.46(a)(3) of Title 10 of the Code of Federal Regulations (10 CFR), for Davis-Besse Nuclear Power Station, Unit 1.
The U.S. Nuclear Regulatory Commission (NRC) staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on December 19, 2011, it was agreed that FENOC would provide a response within 30 days from the date of receipt of this letter.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of
B. Allen
- 2 efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-3867.
/
/
Michael Mahoney, Pr *ect Manager Plant Licensing Bra h 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-346
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1 FIRSTENERGY NUCLEAR OPERATING COMPANY DOCKET NO. 50-346 By letter dated May 27,2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML111510642), FirstEnergy Nuclear Operating Company, the licensee for Davis-Besse Nuclear Power Plant, Unit 1, sent a notice reporting a change or error discovered in an evaluation model or in the application of such a model that affects the peak cladding temperature calculation. This report was submitted pursuant to the requirements of Section 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," of Title 10 of the Code of Federal Regulations (10 CFR 50.46), which requires, in part, that licensees report a change in the evaluation model at least annually. The intent of this requirement is to enable the U.S. Nuclear Regulatory Commission (NRC) staff to establish the safety significance of this change (See Federal Register, Volume 53, No. 180, pp. 35996 36005).
The NRC staff has reviewed the licensee's submittal and determined that the following additional information is required to complete the review:
In Table 1, "10 CFR 50.46 Summary for 2010," it is noted that peak cladding temperatures for Mk-B-HTP fuel in the mixed-core and full-core large-break loss of-coolant accident (LBLOCA) evaluation models are "estimated" per Evaluation Model Revision 0.9. Please clarify why these specific peak cladding temperatures are "estimated" and not "analyzed" similar to the other values in the table.
ENCLOSURE
B. Allen
- 2 efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-3867.
Docket No. 50-346
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL3-2 RlF AGuzzetta, NRRlDSS/SRXB RidsAcrsAcnw_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDorlLpl3-2 Resource RidsNrrDssSrxb Resource RidsNrrLASRohrer Resource RidsNrrPMDavisBesse Resource RidsOgcRp Resource RidsRgn3MailCenter Resource BParks, NRRlDSS/SRXB ADAMS Accession No. ML120170145 Sincerely, IRA!
Michael Mahoney, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation NRR-106 OFFICE LPL3-2/PM LPL3-2/LA LPL3-2/BC LPL3-2/PM NAME MMahoney SRohrer(JBurkhardt for)
JZimmerman MMahoney DATE 1/18/12 1/18/12 1/18/12 1/18/12 OFFICIAL RECORD COpy