{{#Wiki_filter:I Entetgy IPEO IP-RPT-09-00069 1 REV. 0 I Page 51 ofl92 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IWL-068-003 U3-037284 IPEC00241329 IWL-068-003 U3*037285

IPEC IP-RPT-09-00069 I REV. 0 ~Entergy I Pa2e 52 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/Srd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _--=E!.:.,.1.~68~'_-....!E:::..!I.:...;. 8~8=!...J Component No: VCC-10 Zone No: _0=0:<...4'--__ Drawing No.: ISI-IWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only Date:~--,-l_/_*-_6_;_**_**__r_/_U! Date:__¢~_I--,S,->~<-I"_O,--- Recording Condition RI NRI NI NlA Comments Leaching or chemical attack 0 [g1 0 D 1 Abrasion or erosion degradation D 0 [g1 D Pop outs and voids D [g1 D D 3,4 Scaling D [g1 D D 1 Spalls D [g1 D D 1 Corrosion staining on concrete surfaces D [g1 D D 3 Cracks 0 [g1 D D 1,2 Exposed reinforcing steel 0 0 [g1 0 Deteriorating of concrete coating, if applicable 0 0 0 ~ Excessive corrosion of the exposed embedded metal D D [g1 D surfaces Detached embedment or loose bolts 0 0 [g1 0 Other (bugholes, drop-in ancho~sleeves) 0 [g1 0 0 1,5 IN"'",,,"<on,,,'" p""'"",<:'.- ".-<C 0 ~!",P""JT;'""" ''"""'.J J. Skoniecznlit.l~ Ie.... r Examined By: P. Bowe j~..k:::Y" Date: tZ-I Examined By: Date:t.1, Print/Signature ~evel PrintiSignatute/Le~el Responsible Engineer Review: Acceptable: Yes [g1 No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: VIrNTAGE ~i.JT :tf-4 ~ {P H2'()"l\\ ';"( 6u(l.. 1 c...> Pb. '2..0. /. rd' fI RE Signature: R D;~~t~1t4:et'~'--- Site Level III Review:~~~II~IA,,-,--~~~~~~~_ Date:~~~~~~~~_ PrintJSig~;ture/Level ANI! Review: ~ ;;;4e:r-Print/Signature IPEC00241330

eEnte/ID' IPEO IP*RPT-09-00069 I REV. 0 I Pa2e 53 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORMVT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /Indian Point NO.3 ZONE No: 004 COMPONENT NO. :__---=V-=C;.;::C~--'1;..:;O 1 Minor cracks, scaling and spalling, leaching, discoloration - all minor and all previously identified. ~ 2 Large pattern cracking over 5' x 5' area (previously identified). r;2B 3 1-112" dia. pop-out with rust staining, visible between Fan House and Containment. See 91) photo U3-047281. 4 2" dia. pop-out exposing steel with surface corrosion, visible between Fan House and ~lS Containment. See photo U3-047282. 5 Seven W' diameter drop-in anchor sleeves with no evidence of corrosion, visible between ~1> Fan House and Containment. IPEC00241331

.'IEnteIgY IPEC IP-RPT-09-00069 I REV. 0 I Pae:e 54 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IPEC00241332

IEnll'lg}' IPEO IP-RPT-09-00069 I REV. 0 I Page 55 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IPEC00241333

IPSO IP-RPT-09-00069 I REV. 0 ~Entergy I Page 56 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-31GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1S!/3rd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _-=EI,,-,.:=:;68"'-'_---'E::.<I.:..;.8~8:!...' Component No: VCC-12 Zone No: _O:o:..:O~6,--__ Drawing No.: ISI-IWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only Recording Condition RI NRI NI NlA Comments Leaching or chemical attack Abrasion or erosion degradation Pop outs and voids Scaling Spalls Corrosion staining on concrete surfaces Cracks Exposed reinforcing steel Deteriorating of concrete coating, if applicable Excessive corrosion of the exposed embedded metal surfaces Detached embedment or loose bolts D rzI D D 2 o 0 18I D o rzI 0 0 4 D [8J D 0 1 o 0 [8J D o [8J 0 0 4 D rzI D 0 2 o 0 rzI D DOD [8J o 0 [8J 0 o 0 rzI 0 ,/'7 /...., Oate: I__""_f(~'.J_' Other (bugholes, pipe inserts) 0 [8] 0 0 2,5)3 ~~H"IIh!nS;ppeceCI!'tiohlorntalairErr,e!aSlasmctSrt7CirlS's.r-)~-~_-':_(\\:--.--:,- ~'----- Examined By: P. Bowe(Z "~ Date: ~ Examined By: J. Skonieczny AM.Jrrr:... Date:(.,I-Ib-~ Print/Signature~evel PrintlSignature;Le~1 ~ Responsible Engineer Review: Acceptable: Yes rzI No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: VItNT~be ~l"" *" fJ ~ \\\\ ~Ol"\\. '(\\.(i,.0~C l l>rJ fuE.. Z.O '~a./ (/".) /j"c' RE Signature: R. Drake I ;;r:A!1{f.'t?j~)(j~:j~.£lr:~txjJ PrintlS}¢ature/Level / Site Level III Review:~_--,A!-4-:6-,-~,,--_/ Date:~ ~Sig~::Level ANII Review: ~ ~ oate:_-'~L.F-/;",--,Is:_/"-+h~o,---__ Print/Signature IPEC00241334

fa IPSO IP-RPT-09-00069 I REV. 0 -- Entergy I Page 57 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPECI Indian Point NO.3 ZONE No: 006 COMPONENT NO. :__---"V...;::;C...;::;C_-......;1=2 1 Area of light scaling, approximately 5' x 5', between El. 83 and El. 88. (Previously identified) ~& General bugholes, pattern cracking, discoloration, and leaching - all minor and identified

~,

r IJ Sixteen 1" dia. pipe inserts protruding I" from containment surface located under the /t20 equipment hatch. Identified previously in 2001. See photo U3-067284. 4 Three I" pipe inserts previously identified in 2001 with no change. See photo U3-067283. r?r& 5 Two I" locations with minimal coverage over rebar developing rust staining visible from ~9 catwalk leading to ground elevation under equipment hatch. IPEC00241335

I Entetgy IPEO IP-RPT-09-00069 I REV. 0 I Pae.e 58 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IWL-088-001 U3-067283 2001 Inspection Photo IPEC00241336

IPEO IP-RPT-09-00069 I REV. 0 Entergy I Pae:e 59 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IWL*068-006 U3*067284 IPEC00241337 2001 Inspection Photo

IPEC IP-RPT-09-00069 I REV. 0 ~Entergy I Page 60 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT*3/GENERAL VISUAL EXAMINATION Plant: IPEG - Unit 3 Interval Period: 1st/3rd Inspection Inspection Report No.: IP3-09-IWL-001 Component No: VCC-13 Zone No: ....;O~O~1i--__ Drawing No.: ISI-IWL-001

== Description:== _--=E~I...:::8:.:::8_' ---=E"""I.....!.1~O~8' Work Order No: 138856 Equipment Used: Gelestron Giant 20x80 Binoculars Limitations: Accessible areas only g g Recording Condition RI NRI NI N/A Comments Leaching or chemical attack D IZI 0 0 1 Abrasion or erosion degradation 0 D [81 0 Pop outs and voids D D lX'I D Scaling D lX'I D D 1 Spalls D lX'I 0 0 1 Corrosion staining on concrete surfaces D 0 lX'I D Cracks 0 [gI D D 1 Exposed reinforcing steel D D lX'I D Deteriorating of concrete coating, if applicable D D D lX'I Excessive corrosion of the exposed em bedded metal D D lX'I 0 surfaces Detached embedment or loose bolts D 0 lX'I D Other (bugholes) D lX'I D D 2 lNOte: ::iKetCnes or pictures m(Y De 9r~inspeCtion areas anc locations.) J. Skoniecznv(i) It L Date:f..2-16 Examined By: P. Bowe / ~ Date: ~ Examined By: PrintiSi na\\urE~I PrinVSi natuviJLevel -oJ Responsible Engineer Review: Acceptable: Yes lX'I No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: VA,.trnGF. f&tJl -#- 9 V~O'1"\\ ~\\GlJlt \\ 0rJ Th, ZD Date: /.- Date: 4ftS;l!o Site Level III Review:_--,-M~:lA~~~ ~ Date:__~ . ~S~natum/Level ANII Review:~ tf2t2cl: Print/Signature IPEC00241338

AE IPEC IP-RPT-09-00069 I REV. 0 ~ ntergy I Page 61 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /Indian Point NO.3 ZONE No: 001 COMPONENT NO. :__----:.V..;:C..;:C_-...;1=3 1 Minor cracks, leaching, scaling and spalling - all minor and previously identified ~ Numerous bugholes and areas of discoloration (previously identified). I IPEC00241339

IPEO IP-RPT*09-00069 I REV. 0 ~ Entetgy I Pae.e 62 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECll0N RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3 rct Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _-=E.:.:.,1......88=-'_-....:E=:I.......:.:10~8::...' Component No: VCC-14 Zone No: _0,.",0""'2=---__ Drawing No.: ISI-iWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only Recording Condition RI NRI NI N/A Comments Leaching or chemical attack D l8J D D 1 Abrasion or erosion degradation D D l8J D Pop outs and voids D D l8J D Scaling D D l8J D Spalis D 0 l8J 0 Corrosion staining on concrete surfaces 0 0 l8J D Cracks D l8J D D 1 Exposed reinforcing steel 0 0 l8J 0 Deteriorating of concrete coating, if applicable D 0 0 l8J Excessive corrosion of the exposed em bedded metal 0 0 l8J 0 surfaces Detached embedment or loose bolts 0 0 l8J D Other (bugholes) D l8J D D 1,2 tl'101e: >:>KeIGlles or pictu ~ n areas ana locallons.) J. Skoniecznv 0..4. k Examined By: P. Bowe~-4 Date: #- Examined By: Date: J--{J. PrintlSigna\\ur~el PrintlSignaturltlLevel Responsible Engineer Review: Acceptable: Yes l8J No 0 (Detailed VT-1 Examination Required Attachment 7.3) Date: /_. ".1 '"~ ( Site Level III Review:__----:.../II~/L.:f\\:....!--~-----Date: ~i~aturellevel ANII Review: ~---__-"if:;&;c'_'=""_=.I__ Date: 4!--'bS;!lo Print/Signature "7 IPEC00241340

A IPEC IP-RPT-09-00069 I REV. 0 ~Entergy I Pa2e 63 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORMVT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC I Indian Point NO.3 ZONE No: 002 COMPONENT NO. :__-.;;V,...:;;:C,-=C_--.,;1:....;.4 ,A Numerous bugholes, leaching and vertical cracking - all minor and previously identified. II;?!> 2 Reddish discoloration in both zones 2 and 3 over an area of roughly 20'x90' (previously ( [.?f> identified). IPEC00241341

IPSO IP*RPT*09-00069 I REV. 0 ~- Entetgy I Page 64 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3rd Inspection Inspection Report No.: IP3~09~IWL~001 EI. 88' - EI. 108' Component No: VCC-15

== Description:== Zone No: _0:::.,:0"",,30....-__ Drawing No.: ISI~IWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only -_-41' g Recording Condition RI NRI NI N1A Comments Leaching or chemical attack 0 ~ 0 0 1 Abrasion or erosion degradation 0 0 18I 0 Pop outs and voids 0 0 ~ 0 Scaling 0 0 ~ 0 Spalls 0 r8J 0 0 1 Corrosion staining on concrete surfaces 0 0 ~ 0 Cracks 0 ~ D D 1 Exposed reinforcing steel 0 0 r8J 0 Deteriorating of concrete coating, if applicable 0 0 0 r8J Excessive corrosion of the exposed embedded metal 0 0 r8J 0 surfaces Detached embedment or loose bolts 0 0 ~ 0 Other (bugholes) 0 r8J 0 0 1,2 (Note: ::;Ketcnes or picturesrroe vClai].:lU.CspectlOn areas ana locations.) J. Skonieczny !J..LJA I.J.. Date:/J-Lb Examined By: P. BoweI~ Date: ~ Examined By: PrintiSignatur'li2'Cevel PrinVSi natur6/Le~ ~ Responsible Engineer Review: Acceptable: Yes r8J No D (Detailed VT-1 Examination Required Attachment 7.3) Comments: V"4JfAr~E \\i'N"'- :it l./ 3: f 4 £RoM he;...gs<: \\ all fa. 2.-0, f IPEC00241342

ItEntergy IPEC IP-RPT-09-00069 I REV. 0 I Page 65 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORMVT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /Indian Point NO.3 ZONE No: 003 COMPONENT NO. :__----:;V..;:;C..;:;C_---=1=5 ~ 1 Numerous bugholes, leaching, spalling, and cracking - all minor and previously identified. 2 Reddish discoloration in both zones 2 and 3 over an area of roughly 20'x90' (previously tfr?; identified). IPEC00241343

IPSO IP-RPT-09-00069 I REV. 0 ~ Entergy I Pa~e 66 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3rd Inspection Inspection Report No.: IP3-09-IWL-001 Component No: VGC-16 Zone No: _0",",0~4,---__ Drawing No.: ISI-IWL-001

== Description:== __E=I,,-"=88=<.,.'_-...."E=I:.....1-,-,0...,,8:....' Equipment Used: Celestron Giant 20x80 Binoculars Work Order No: 138856 Limitations: Accessible areas only Recording Condition RI NRI NI N/A Comments Leaching or chemical attack 0 [8J 0 0 1 Abrasion or erosion degradation 0 0 r8l 0 Pop outs and voids 0 0 [8J 0 Scaling 0 [8J 0 0 1 Spalls 0 [8J 0 0 1 Corrosion staining on concrete surfaces 0 0 [8J 0 Cracks 0 [8J 0 0 1 Exposed reinforcing steel 0 0 [8J 0 Deteriorating of concrete coating, if applicable 0 0 0 [8J Excessive corrosion of the exposed embedded metal 0 0 [8J 0 surfaces Detached embedment or loose bolts 0 0 [8J 0 Other 0 0 [8J 0 /"\\ (Note; oKetCnes or pictures ~ oe .~I~nspectlon areas anc locations.) J. Skoniecznv.G.t..i..,k Date: IJ. Examined By: P. Bowe/~] Date: ~Examined By: PrintiSigna~ur~1 Print/Signatur6lLevei Responsible Engineer Review: Acceptable:' Yes [8J No 0 (Detailed VT-1 Examination ReqUired Attachment 7.3) Comments: VJ\\,Jrk'f. ~,oJ"- ':It 4 ~ lP foM. f\\(,,0@. \\ 0"'> J'6 20 Date:__4;L-T-t.:.....)S---./PIt'-"o"---_~ .07 ( ,I (); {-. VI/I'I 'r .M i' -'-/' RE Signature: R. Drake 1(\\(,51'L.~£k"V,",*.:i&; il...fJI'V"*\\ PrinVSign~;I1?e/Level / ,~.." Site Level III Review:__/_/--'-N.c....L../_A=--- Print/Signature/Level ANII Review: ~ t~ Print/Signature Date: (- '7-- ['6 Date: IPEC00241344

A IPEC IP*RPT-09-00069 I REV. 0 ~Entergy I Page 67 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORMVT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3/GENERAL VISUAL EXAMINATION STATION/UNIT: lPEC / Indian Point No.3 ZONE No: 004 COMPONENT NO. :__.......:.V~C~C_-...:1~6 1 Minor cracks due to shrinkage, leaching, scaling and spalling - all minor and previously identified. q IPEC00241345

A IPEO IP-RPT-09-00069 I REV. 0 ~Entergy I Pa~e 68 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3rd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _---=ECU-1.....8""8_'----=E~1..,..,.1-"'0:><.8' Component No: VCC-17 Zone No: _0....0~5~__ Drawing No.: ISI-1WL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only g g Recording Condition RI NRI NI NlA Comments Leaching or chemical attack 0 [gJ 0 0 1 Abrasion or erosion degradation 0 0 r2l 0 Pop outs and voids 0 0 [gJ 0 Scaling 0 [gI 0 0 1 Spalls 0 [gJ 0 0 1 Corrosion staining on concrete surfaces 0 0 [gJ 0 Cracks 0 [gI 0 0 1 Exposed reinforcing steel 0 0 18I 0 Deteriorating of concrete coating, if applicable 0 0 0 [gJ Excessive corrosion of the exposed embedded metal 0 0 18I 0 surfaces Detached embedment or loose bolts 0 0 [gI 0 Other (bugholes) 0 18I 0 0 1 (Note; ;:iKetcnes or pictures mruu to Clarity Inspection areas and locations.) J. Skoniecznv,{),.LIt.. ~ Date: Examined By: P. Bowe ~~ -Date: l~ Examined By:

J..-

Print/Si naturiYLcevel PrinVSi naturMLevel ......J' Responsible Engineer Review: Acceptable: Yes 18I No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: Vwn.r:.£ el,Jl -4\\' 1 f#l'\\ f\\(i,ut<:£ I tS.J ?G. z.o Date:_-,-/_*-_-_.-'-'1_-_-(_.-'-6 /c;,;"?£/,." > /.!) ./ RE Signature: R. D;~~~~~~;r~~.s. }ii(tc~L!%(>'"< Site Level III Review: '"fA. Date:~ ~~:~vel = ANII Review: ~ ~ Date;_--.-.1.4j'--j!t~.:-/Sj:::c..(r-/;--'-I-"O'----__ Print'Signature IPEC00241346

IPEC IP-RPT-09-00069 I REV. 0 ~Entergy I Pal!e 69 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSEAVICE INSPECTION RECORD OF VT - 3/GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC / Indian Point NO.3 ZONE No; 005 COMPONENT NO. :__----::V....::::C:..::::::C~-""'"'1~7 Numerous bugholes, vertical and joint cracks, leaching, scaling and spalling - all minor and previously identified. The majority of this component is inaccessible. IPEC00241347

A IPSO IP-RPT-09-00069 I REV. 0 -===-.Entergy I Page 70 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-31GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3rd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _-=E:.:..1.=88:=..'_-....:E=I......1..:..:0..,,8~' Component No: VCC-18 Zone No: _O~O~6~ Drawing No.: ISHWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only Recording Condition RI NRI NI N/A Comments Leaching or chemical attack 0 [8J 0 0 2 Abrasion or erosion degradation 0 [8J 0 0 2 Pop outs and voids 0 [8J 0 0 3 Scaling 0 [8J 0 0 2 Spa11s 0 [8J 0 0 2 Corrosion staining on concrete surfaces 0 [8J 0 0 1,3 Cracks 0 [8J 0 0 2 Exposed reinforcing. steel [8J 0 0 0 1 Deteriorating of concrete coating, if applicable 0 0 0 [8J Excessive corrosion of the exposed embedded metal [8J 0 0 0 1 surfaces Detached embedment or loose bolts 0 0 [8J 0 Other (bugholes, exposed miscellaneous steel) 0 [8J 0 0 2,4,5 (Note: ::iKetenes or picturesz::roe atIr~c'arlry Inspection areas anc lOcations.) J. SkoniecznvQ,,4,. It.:... Date:lJ.- Examined By: P. Bowe / ~ ~ Date: J~ Examined By: PrintiSignatlue \\.'eVe1 PrintlSignaturMevel ~ Responsible Engineer Review: Acceptable:* Yes [8J No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: JaUTPff,;.C ?t" *..r...... -:IfB 11l r~"", fI~. \\ tit,) \\'="~. 2.0 / /" RE Signalure: R. D;~~:§~;f~dl1 Vf1dp{t~!~ Date: /,~ 'lic Site Level III ReView:' ,.;/A Date: ~i9':'tureJLevel ANII Review: ~ ~ Date:_~rh~/,.!-:/.s=-I+d-'--'1-0~-- Print/Signature 7 IPEC00241348

IPEC IP-RPT-09-00069 I REV. 0 ~Entergy I Pae:e 71 ofl92 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /Indian Point No.3 ZONE No: 006 COMPONENT NO. :__---:.V..::::C..::::C_-~1~8 Exposed metal tip, roughly 1-1/2" dia., flush to concrete surface with a 5' long rust streak at El. 95. r# 1 Update: Condition was found to be the same since the previous inspection and then coated in 2009 to prevent further corrosion. See photo U3-067281 and indication #1 of Attachment 8.5 for before and after photo. Minor pattern cracking, leaching, scaling (less than 4" diameter area), bugholes, roughly ~6 2 5'x5' area of discoloration, joint spalling and areas with abrasion - all minor and previously identified. Small pop outs with rust and staining (previously identified). ~ Exposed embedded steel plate, approximately 2" x 4", with surface rust and staining at E1. ~1ft 4

98. Area coated in 2009 to prevent future corrosion. See indication #3 of Attachment 8.5 for befor~....~~~...~fter photos.

Two small exposed metal inserts with minimal rust and staining between E1. 93'-0" and E1. ~~ 5 98'-0". See indication #2 of Attachment 8.5 for before and after photos. IPEC00241349

IEnfelgy IPSO JP-RPT-09-00069 I REV. 0 I Pal!:e 72 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IWL-088-006 2001 Inspection Photos IPEC00241350

IAE IPSO IP-RPT-09-00069 I REV. 0 ~. ntetgy I Pa2e 73 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1sl/3rd Inspection Inspection Report No.: IP3-09*IWL*001 E1. 108' - EI. 128' Component No: VCC-19

== Description:== Zone No: ....;O~O"""1i.--__ Drawing No.: ISI-IWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars limitations: Accessible areas only g g Recording Condition RI NRI NI N/A Comments Leaching or chemical attack D ~ D D 1 Abrasion or erosion degradation D D 18I D Pop outs and voids D D ~ D Scaling D ~ D D 1 Spalls D ~ D D 1,2 Corrosion staining on concrete surfaces D D [8J D Cracks D ~ D D 1 Exposed reinforcing steel D D [8J D Deteriorating of concrete coating, if applicable D D D [8J Excessive corrosion of the exposed embedded metal D D [8J D surfaces Detached embedment or loose bolts D D [8J D Other (bugholes) D [8J D D 1,2 (NOte: ::iKelCnes or pictures ~ ..-t!! l~speCllon areas anc locations.) J. Skonieczny~ k Examined By: P. Bowe~4 \\,..?) Date: I~ Examined By: Date" J-16 PrintlSi nature'1Level PrintlSi naturU/Level -J Responsible Engineer Review: Acceptable: Yes [8J No D (Detailed VT-1 Examination Required Attachment 7.3) Comments: Ja...mt.&(; ~ 1r.J'l '"" 9 J 10, ~ \\ \\ 'feD""

fiG, btJ P(;, -2.0

'0 ,f~ l~- /-- (' () Date:_..:....------i:f RE Signature: R. Drake I )1ii;i6:t~j('ft1~t~l .*",ii-'" i

./. ;;,

Printf.Sigf1atu re/Lev~:", Site Level III Review: AIfA Date:~ ~i~/Level ANII Review:~ ~ Date:_-,~,---+£..L.-.:::.S:::"/~;;o....cO=---__ Print'Signature IPEC00241351

A IPSO IP-RPT-09-00069 I REV. 0 -:::-Entergy I Page 74 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /lndian Point NO.3 ZONE No: 001 COMPONENT NO. :__---"V....;::;C....;::;C_-......;1=9 fI9 1 Pattern cracking, numerous bugholes, leaching, scaling and spalling - all minor and previously identified. 2 Area of exposed aggregate due to joint spalls and areas of discoloration - all minor and r?j$ previously identified. IPEC00241352

IPEC JP.RPT-09-00069 I REV. 0 ~Entergy I Pa~e 75 of 192 JP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECll0N ReCORD OFVT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3 rd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== __......::::.E:.:.,.I...:,.1O:::..:8~'_-...!;E:.l;I.=-1~2:.l;i8~' Component No: VCC*20 Zone No: _O~O=2~ Drawing No.: ISI*IWL*001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only 9 g Recording Condition RI NRI NI NlA Comments Leaching or chem ical attack D l8J D D 1 Abrasion or erosion degradation D D [81 D Pop outs and voids D D l8J D Scaling 0 0 l8J 0 Spalls 0 l8J 0 0 2,4 Corrosion staining on concrete surfaces 0 0 l8J 0 Cracks 0 l8J D D 1 Exposed reinforcing steel l8J D D D 2 Deteriorating of concrete coating, if applicable D D D l8J Excessive corrosion of the exposed em bedded metal D D l8J D surfaces Detached embedment or loose bolts D D l8J 0 Other (bugholes) D l8J D 0 1,3 (Note: oKelcnes or PIC1ures3)~ ~v 10 Clarity InspeCtion areas anc locations.) J. Skonieczny~: Date: 11-/, Examined By: P. Bowe ~h -Date:i.Examined By: Print/Si nature'ICevel Print/Si natur Level 5 Responsible Engineer Review: Acceptable: Yes l8J No 0 (Detailed VT-1 Examination Required Attachment 7.3) Comments: VAtiftr6( ~lrJi -it I ~J 2. ft,ol\\<\\. ~\\'" I \\ dJJ?l.. 2.0 .......,/14 11< RE Signature: R. Drake /-,L-/*\\.,~c:;. .,/""~,,,,,,:.fr,",,,~,,,,-I;-=-'t'-,=-J"7-=-))"9'----.,L~_"---"-_-'----_ Date:__----"- PrintlSi.9mifure/LeveJ// Site Level III ReView:_'_/_--,N~h",-,A,-----"_' Date: ~ig~.,ur:!LeVel ANII Review: ~ ~ Date: 412-J/;~/'_"5"'_/Th_'_IO''--- Print/Signature I IPEC00241353

f Enteigy IPEC IP-RPT-09-00069 I REV. 0 I Paee 76 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 FORMVT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3/GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC / Indian Point NO.3 ZONE No: 002 COMPONENT NO. :__---=V-=C;.:C;,.....-.:;:.2=-O f:9 1 Numerous bugholes, leaching and vertical cracking - all minor and previously identified. 2 Minor spalls, approximately 1-3" long and less than 1ft!" wide, some exposing small areas of 2J rebar (previously identified). See photo U3-021211. 3 Reddish discoloration in both zones 2 and 3 over an area of roughly 20'x90' (previously .~ identified). 4 Concrete separated indicating potential future spall of 6" x 3" area at El. 113'. See photo ( ~ U3-027223. IPEC00241354

I Entetgy IPEO IP-RPT-09-00069 I REV. 0 I Pag:e 77 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IPEC00241355

I Entelgy IPEO IP-RPT-09-00069 I REV. 0 I Pa!!e 78 of 192 IP3 ASME Section XI, IWL Concrete Containment Inspection for 2009 IPEC00241356

fa IPEC Ip*RPT*09*00069 I REV. 0 -===-Entergy I Page 79 of 192 IP3 ASME Section XI~ IWL Concrete Containment Inspection for 2009 CONTAINMENT INSERVICE INSPECTION RECORD OF VT-3/GENERAL VISUAL EXAMINATION Plant: IPEC - Unit 3 Interval Period: 1st/3 rd Inspection Inspection Report No.: IP3-09-IWL-001

== Description:== _---=.E!.:.,.I.....!..10~8:!...'_-...!:E=l.I.:....1~2::.108~' Component No: VCC-21 Zone No: -'0""'0:.:3'"--__ Drawing No.: ISI-IWL-001 Work Order No: 138856 Equipment Used: Celestron Giant 20x80 Binoculars Limitations: Accessible areas only g g Recording Condition RI NRI NI N/A Comments Leaching or chemical attack D [gl D D 1 Abrasion or erosion degradation D D [gl D Pop outs and voids D [gl D D 3 Scaling D D [gl D Spalls D [gl D D 1 ~2~3 Corrosion staining on concrete surfaces D [gl D D 2,3 Cracks D [gl D D 1 Exposed reinforcing steel [gl D D D 2 Deteriorating of concrete coating, if applicable D D D [gl Excessive corrosion of the exposed embedded metal D D [gl D surfaces Detached embedment or loose bolts D D [gl D Other (bugholes) D [gl D D 1,4 (NOte: ::;KetCnes or pictures may to clamy inspection areas ana locations.) J. Skonieczny/1AL k" Date: lJ.. Examined By: P. Bowef~~ Date: jt..bp{o~ Examined By: Print/Si naiure}Level PrintiSi natunULevei ~ Responsible Engineer Review: Acceptable: Yes [gl No D (Detailed VT-1 Examination Required Attachment 7.3) Comments: VkrJTMt ~luT:tt-1. J > I c:;- f="ilbM.. J(\\b, \\ DIY R;, 'z.t;; Site Level III Review: ....::..A/7;,'-!..~-'---- Date: ~ignrture/Level ANII Review: ~--/~Date: ¢~~O Print/Signature IPEC00241357

A E IPSO IP-RPT-09-00069 I REV. 0 ~ ntergy I Paee 80 of 192 IP3 ASME Section XI. IWL Concrete Containment Inspection for 2009 FORM VT-3C CONTAINMENT INSERVICE INSPECTION RECORD OF VT - 3 /GENERAL VISUAL EXAMINATION STATION/UNIT: IPEC /Indian Point No.3 ZONE No; 003 COMPONENT NO. :__----.:V-=C-=C_-..:2:..:,1 f"', ~ 1 Numerous bugholes, leaching, spalling and cracking - all minor and previously identified. 7" long x Y.!" wide exposed steelbar With rust and staining due to spalling at EL 118 (previously identified). Update: The exposed metal was identified not to be reinforcing bar ',?B and has been coated for future protection against water intrusion and corrosion. See photo U3-037226 and indication #15 of Attachment8.5 for before and after photos. Partial spall, less than 3" diameter, with surrounding minor pop outs, W' diameter, with ~\\? visible rust (previously identified). Reddish discoloration in both zones 2 and 3 over an area of roughly 20'x90' (previously ~ identified). IPEC00241358}}