Potential Sources of Tritium at IPEC Inspection method Tanks and Pools Unit lFuel Pool MW-42, MW-39, Pool level monitoring, HTO mass balance Unit 2 Fuel Pool Leak collection box, MW-30, Pool level monitoring, Boron Regression Analysis Unit 3 Fuel Pool Tell tale drain system, Pool level monitoring, MW-44, MW-45 Unit2 RWST MW-42, physical inspection Unit3 RWST MW-39, MW-41, physical inspection Unit 2 eves Tanks MW-42, physical inspection Unit 3 eves Tanks MW-42, MW-43, physical inspection Unit 2 Waste Hold-up Tanks MW-42, physical inspection Unit 3 Waste Hold-up Tanks MW-41, MW-43, physical inspection U2 SFP Transfer Canal MH-5 sample, physical inspection Above and below ground Piping Unit 1 Waste Transfer Line Unit 2 and 3 RWST Lines Unit 3 to Unit 2 Blowdown Transfer Line Unit 2 and 3 Vapor Containment (VC) foundation drain Unit 1 foundation drain Unit 1 CSB foundation drain Miscellaneous drains between buildings Building Sumps I PEC00065506 RIV000087 Submitted: December 22, 2011

Unit 2 & 3 P AB Sumps Unit 2 MOB sump Unit 3-Room with the rock, had pipe trench from P AB spilling into area below cable tunnel Unit 2 Transformer Yard - Turbine hall condensate drainage Other Legacy Releases I Spills 50.75(g) records Unit 2 Resin Spill in alleyway next to FSB Unit 2 Blowdown atmospheric release Unit 2 SG Tube Leak Feb 2000 Unit 3 Area between VC, FSB, P AB, (aka Pigeon Pit)

Unit 3 Sewage septic field Unit 3 SG Tube Leak Oct 1989 Unit 3 RWST base of hill contaminated water stream IPEC00065507