Exemption Request for NUHOMS Hd Dry Shielded Canisters Loaded to Incorrect Heat Load Limits Supplemental Information
ML11286A115
Person / Time
Site: Surry, 07200055  
(DPR-032, DPR-037)
Issue date: 09/28/2011
From: Price J
Virginia Electric & Power Co (VEPCO)
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
11-251A
Download: ML11286A115 (13)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 September 28, 2011 Attention: Document Control Desk Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Serial No.:

NL&OS/TJS:

Docket Nos.:

License Nos.:

11-251A RO 50-280/281, 72-55 DPR-32/37 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 EXEMPTION REQUEST FOR NUHOMS HD DRY SHIELDED CANISTERS LOADED TO INCORRECT HEAT LOAD LIMITS SUPPLEMENTAL INFORMATION In a letter dated July 21, 2011 (Serial No.11-251), Virginia Electric and Power Company (Dominion) requested a one-time exemption from the requirements of 10 CFR 72.212(b)(3) and (b)(1 1) for NUHOMS-D HD Dry Shielded Canisters (DSC), Model Number HD-32PTH, with serial numbers DOM-32PTH-001-C, -002-C, -003-C, and -009-C. The exemption is needed to address a non-compliance with the terms and conditions of the Transnuclear, Inc. (TN) Certificate of Compliance (CofC) Number 1030, Amendment 0, at the time of cask loading at Surry Power Station.

The purpose of this letter is to provide supplemental information, as requested by the NRC staff, in support of the exemption request. Attachment 1 contains supplemental environmental information. Attachment 2 provides the ANSYS computer code files on compact disk (CD) used by TN to generate the previously submitted thermal evaluation including a copy of the original proprietary affidavit which bounds the information on the CD. If you have any questions, please contact Mr. Thomas Szymanski at (804) 273-3065.

Sincerely,

\\ice resident - Nuclear Engineering

\\/riia Electric and Power Company COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO VICKI L. HULL Notary Public Commonwealth of Virginia 140542 My Commission Expires May 31. 2014

))

)

The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by J. Alan Price, who is Vice President - Nuclear Engineering, of Virginia Electric and Power Company. He has affirmed before me that he is duly authorized to execute and file the foregoing document in behalf of that Company, and that the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this 00f.I day oof

.,m 2011.

My Commission Expires:

.2'0 /1/.

T/'

A Notary Public 19

Serial No. 11-251A Docket Nos. 50-280/281, 72-55 Page 2 of 3 Attachments:

1. Supplemental Environmental Information
2. ANSYS Files and Proprietary Affidavit Enclosed with this submittal is a CD which contains the Attachment 2 ANSYS Input Files requested, labeled:

Disk 1 of 1 ANSYS Input Files Calculation 10494-174 R-0 Transnuclear Inc. Proprietary Attachment to Dominion Letter 11-251A The enclosed CD contains the following files:

File Number File Name Description File Size Sensitivity 1

DSC.cdw Geometry for 32PTH DSC 140 MB Proprietary 2

10494-174 Rev O.doc TN CaIc. 10494-174, Rev. 0 270 KB Proprietary 3

nDSChf.txt DSC shell temp profile 1.48 MB Proprietary for off-normal conditions 4

DSC-1 15-ReConf.db ANSYS.db file 464 MB Proprietary 5

Heatgen-reconf.mac Heat generation macro 2 KB Proprietary w/ zone 1 at 0.86 kW 6

DSC-1 15-ReConf.mntr ANSYS.mntr file 1 KB Proprietary 7

DSC-1 15-ReConf.osav ANSYS.osav file 41 MB Proprietary 8

Matlnp.MAC Material properties macro 6 KB Proprietary for 32PTH DSC 9

DSC-1 15-ReConf.err ANSYS.err file 2 KB Proprietary 10 DSC-115-ReConf.inp ANSYS.inp file 2 KB Proprietary 11 DSC-115-ReConf.s01 ANSYS.sOl file 10.6 MB Proprietary 12 DSC-115-ReConf.out ANSYS.out file 2.5 MB Proprietary 13 DSC-1 15-ReConf.rth ANSYS.rth file 527 MB Proprietary 14 eccp-ansys-job.txt ANSYS job execution file 134 byte Proprietary Commitments made by this letter: None

Serial No. 11-251A Docket Nos. 50-280/281, 72-55 Page 3 of 3 cc: U. S. Nuclear Regulatory Commission*

Region II Marquis One Tower 245 Peachtree Center Avenue, NE Suite 1200 Atlanta, Georgia 30303-1257 Ms. K. R. Cotton*

NRC Project Manager U. S. Nuclear Regulatory Commission Mail Stop 08 G-9A One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 Mr. R. E. Martin*

NRC Project Manager U. S. Nuclear Regulatory Commission Mail Stop 08 G-9A One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector*

Surry Power Station

  • w/o Attachment 2

Serial No. 11-251A NUHOMS Exemption Request, Page 1 of 6 Attachment I EXEMPTION REQUEST FOR NUHOMS HD DRY SHIELDED CANISTERS LOADED TO INCORRECT HEAT LOAD LIMITS SUPPLEMENTAL ENVIRONMENTAL INFORMATION SURRY POWER STATION - UNITS 1 AND 2 VIRGINIA ELECTRIC AND POWER COMPANY

Serial No. 11-251A NUHOMS Exemption Request, Page 2 of 6 Supplemental Environmental Information Description of the Proposed Action In a letter, dated July 21, 2011 (Serial Number 11-251), Virginia Electric and Power Company (Dominion) requested a one-time exemption from the requirements of 10 CFR 72.212(b)(3) and (b)(11) pursuant to 10 CFR 72.7, for Transnuclear, Inc. NUHOMS HD Dry Shielded Canisters (DSC), Model Number HD-32PTH, with serial numbers DOM-32PTH-001-C, -002-C, -003-C, and -009-C. The regulations require, in part, compliance to the terms and conditions of the Certificate of Compliance (CofC).

Contrary to this requirement, these four DSCs were not loaded in compliance with the decay heat limits in CofC Number 72-1030, Amendment 0, at the time of loading.

The 32PTH DSC is designed for zoned upper loading with respect to decay heat. The four center locations are divided into an upper Zone 1 b and a lower Zone la with the lower Zone la locations allowing a greater decay heat than the upper Zone lb locations. The upper and lower orientation of the Zone I b and Ia locations were reversed when preparing the DSC loading maps for the affected DSCs. As a result of this error, five fuel assemblies were placed in DSC locations where their decay heat at the time of loading slightly exceeded the functional and operational limits established by CofC 1030, Amendment 0 Technical Specification Section 2.1.

The five fuel assemblies are distributed over the four DSCs previously identified. As of March 24, 2011, the date of discovery, the decay heat of these five fuel assemblies had already decreased such that the decay heat limit as stated in the CofC 1030 Technical Specifications had been met.

The decay heat of all fuel assemblies in the affected DSCs have decreased to within the CofC 1030 decay heat limits for those locations. However, loading fuel assemblies outside of location specific CofC 1030 decay heat limits is not allowed. Therefore, Dominion requested an exemption in order to document the acceptability and safety basis for allowing the affected DSCs to remain loaded in their current configuration.

Purpose of Environmental Report The purpose of this assessment is to evaluate the environmental impacts of the proposed exemption request made by Dominion. The information contained in this assessment is intended to aid the NRC staff in performing an environmental assessment.

Serial No. 11-251A NUHOMS Exemption Request, Page 3 of 6 Environmental Impacts of the Proposed Action The Surry Power Station (SPS) Independent Spent Fuel Storage Installation (ISFSI) is a radiologically controlled, Protected Area (PA) with limited access and is located inside the SPS Owner Controlled Area (OCA).

The area considered for potential environmental impact as a result of this exemption request is the area in and surrounding the ISFSI.

As described in the exemption request, Transnuclear, Inc. has performed a thermal analysis that conservatively bounds the as-loaded configurations of the affected DSCs. The analysis concluded that fuel cladding temperatures for the as-loaded 32PTH DSCs were below the fuel cladding temperature limit of 752°F for storage and transfer conditions at the time of loading. The analysis also concluded the DSC fuel compartment and support rail temperatures were bounded by those used in the design basis analysis, indicating there was no detrimental impact on the design basis structural evaluation of the DSC basket.

Furthermore, the DSC internal pressure remained below the design limit, the design basis shielding analysis remained bounding, and the reactivity parameters of the fuel assemblies were not affected. The analysis concluded that the integrity of the DSC and its ability to perform its intended design functions was not compromised due to the mis-load.

The interaction of the DSC with the environment is through the shielding, confinement, and thermal design functions. The shielding design function will continue to limit external dose to levels bounded by the NUHOMS HD Final Safety Analysis Report (FSAR).

The thermal analysis showed that the confinement design functions of the fuel cladding and the DSC structure were not adversely impacted by the as-loaded configurations. Therefore, it can be concluded that all DSC design functions impacting interaction with the environment were unaffected during the time that the as-loaded DSCs did not comply with the CofC 1030 decay heat limits, and were bounded by the NUHOMS HD FSAR evaluations.

Because all fuel assemblies in the affected DSCs met the Technical Specification decay heat limit as of March 24, 2011, it can also be concluded that all DSC design functions impacting interaction with the environment are, and will continue to be, bounded by the NUHOMS HD FSAR evaluations.

Dominion concludes that there are no gaseous, liquid or solid effluents (radiological or non-radiological), radiological exposures (worker or member of the public) or land disturbances associated with the proposed action.

Therefore, approval of the requested exemption to allow the canisters to remain as loaded has no impact on the environment.

Serial No. 11-251A NUHOMS Exemption Request, Page 4 of 6 Adverse Environmental Effects Which Cannot be Avoided Should the Exemption be Approved As noted previously, there are no environmental impacts associated with approval of this exemption.

Therefore, there are no adverse environmental effects which cannot be avoided should the exemption request be approved.

Alternative to the Proposed Action An alternative to the proposed exemption would be to correct the condition by reloading the affected DSCs in compliance with the CofC 1030 decay heat limits. This would involve the following steps:

Retrieve each affected DSC from its respective Horizontal Storage Module (HSM) and transfer back to the spent fuel pool.

" Perform necessary procedures to machine off the outer lid and inner shield plug, and open the DSC.

Unload all fuel assemblies to the spent fuel pool.

Inspect top shield plug, outer lid, and DSC for damage incurred during the machining process.

Inspect DSC basket and repair/replace damaged components as necessary.

Replace the used DSC with a new DSC (if DSC is unable to be reused).

Reload fuel assemblies into the DSC such that the decay heat for all assemblies meet the CofC 1030 decay heat limits.

Perform necessary procedures to close and vacuum dry the DSC.

  • Transfer the DSC back to the ISFSI and re-insert into the HSM.

This alternative would restore the affected DSCs to compliance with CofC 1030.

Environmental Impacts of the Alternatives to the Proposed Action In addition to other undesirable impacts as described in the analysis section below, environmental impacts of the alternative to the proposed action would include both real and potential radiological impacts. These would include the generation of additional radiologically contaminated material during the unloading and loading processes, an increase in personnel exposure during all phases of the unloading and loading processes, and additional opportunities for design basis accidents such as a fuel handling or cask drop event. None of the real or potential environmental impacts associated with the alternative action would be incurred for the proposed action.

Serial No. 11-251A NUHOMS Exemption Request, Page 5 of 6 Analysis Dominion's request for exemption from 10 CFR 72.212(b)(3) and 10 CFR 72.212(b)(11) has no adverse impact to the environment.

Approval of the exemption request would allow maintaining the DSCs in their current state.

This action is supported by the Transnuclear, Inc. analysis referenced in the exemption request, which verified the as-loaded canisters have continued to perform all design functions and meet all FSAR design limits from the time of initial loading. The analysis also showed that the non-conforming decay heat values did not result in any structural damage to the DSC which would degrade the design functions for current and future operation. Therefore, because the decay heat of all affected assemblies now meets the CofC 1030 decay heat limits and the DSC design function has been shown to not have been adversely affected, there is no technical reason to require unloading and reloading the affected DSCs as described in the alternative to the proposed action.

The proposed action would not result in adverse impact to the environment, additional expenditures, or other uncertainties or risks associated with the alternative to the proposed action as discussed below.

An alternative to the proposed exemption would be to correct the condition by unloading and reloading the affected DSCs in compliance with the CofC 1030 decay heat limits. The general steps that would be performed to complete the unloading and reloading processes were discussed previously. These steps would introduce additional opportunities for design basis accidents such as a fuel handling or cask drop event, which could increase the risk of an environmental impact due to the release of radioactive material. These steps would also increase the amount of radiologically contaminated material generated due to additional unloading and loading operations. This includes the used DSC, which would have to be disposed of properly. Additional DSC unloading and loading would increase personnel radiation exposure by an estimated 250 mRem per affected DSC. This estimate is based on Dominion's previous experience for personnel exposure during all phases of the loading process.

The alternative to the proposed exemption would also result in considerable costs to Dominion and its rate payers.

The "per DSC" costs include an estimated $150,000 dollars for unloading, $150,000 dollars for reloading,

$1,000,000 dollars for the purchase of a new DSC, and $200,000 dollars to dispose of the old DSC. These costs are estimates based on Dominion's past DSC procurements and labor rates associated with loading processes.

Past operating experience at another power plant describes an event in which the top shield plug of a loaded 32P DSC had to be removed via a machining process due to a misalignment. Because neither the top shield plug nor the DSC shell were damaged during the machining process, the existing top shield plug was able to be welded back into place.

Serial No. 11-251A NUHOMS Exemption Request, Page 6 of 6 It is possible that the affected DSCs could be reused if no damage is incurred as a result of the alternative action. Damaged components would be evaluated and replaced if necessary. Because of the uncertainty in this process, and the lack of previous experience in unloading DSCs, the Dominion cost estimate assumes all affected DSCs will require replacement.

As a result of this environmental assessment, Dominion concludes that the proposed action, which will allow maintaining the affected DSCs in their current storage configuration, is in the public interest in that it avoids the adverse environmental, radiological, and financial effects associated with the alternative to the proposed action.

Status of Compliance Neither the proposed action as described in this environmental assessment nor the alternative to the proposed action require any additional Federal permits, licenses, approvals, or other entitlements.

Serial No. 11-251A NUHOMS Exemption Request, Page 1 of 2 EXEMPTION REQUEST FOR NUHOMS HD DRY SHIELDED CANISTERS LOADED TO INCORRECT HEAT LOAD LIMITS TRANSNUCLEAR, INC. CALCULATION NO. 10494-174 ANSYS FILES AND PROPRIETARY AFFIDAVIT SURRY POWER STATION - UNITS I AND 2 VIRGINIA ELECTRIC AND POWER COMPANY

Serial No. 11-251A NUHOMS Exemption Request, Page 2 of 2 On July 21, 2011, Dominion submitted an exemption request to the NRC for NUHOMS Dry Shielded Canisters (DSC) loaded to incorrect heat load limits at Surry Power Station (Serial No.11-251). Included in that submittal were Transnuclear, Inc. (TN) Calculation 10494-174, "Effect of the Reversed Loading Patterns on the Thermal Performance of 32PTH DSC", and a TN affidavit requesting withholding of the calculation from public disclosure on the basis that the calculation is proprietary.

Please find included a compact disk with the ANSYS files required to run the thermal analyses presented in TN Calculation 10494-174. As TN considers the ANSYS files part of the original calculation, the proprietary status requested for the calculation extends to the ANSYS files supplied as supplemental information.

A copy of the original Affidavit for TN Calculation 10494-174 is attached.

A AR EVA Mr. Cary Laroe E-31109 Supervisor, Nuclear Engineering TN Project 10494 Dominion, Nuclear Analysis and Fuel June 21, 2011 500 Dominion Blvd Glen Allen, VA 23060

Subject:

Affidavit for TN Calculation 10494-174

Reference:

1. Dominion Master Services Agreement: 46017934
2. Dominion Release No.: 7010848
3. TN Calculation 10494-174 Attachments: Affidavit Pursuant to 10 CFR 2.390 Dear Mr. Laroe Please find attached an Affidavit concerning the proprietary nature of TN Calculation 10494-174 (Ref 3). TN recognizes that Dominion Resources will be using Ref 3 as an appendix to the following exemption letter:

For Surry:

Letter Serial No.11-251 Virginia Electric and Power Company Surry Power Station Units 1 and 2 Exemption Request for NUHOMS HD Dry Shielded Canisters Loaded to Incorrect Heat Load Limits For North Anna:

Letter Serial No.11-262 Virginia Electric and Power Company North Anna Power Station Units 1 and 2 Exemption Request for NUHOMS HD Dry Shielded Canisters Loaded to Incorrect Heat Load Limits Please attach the affidavit to the cover of the calculation (Ref 3) whenever submitting the document to the NRC as part of the aforementioned letter(s). Reference 3 is intended for Dominion use and is not intended for public dissemination.

If you have any questions, please feel free to contact me at (410) 910-6949 or Ken.Boone@AREVA.com.

Best Regards, Kenneth R. Boone Sr. Project Manger Cc:

R. Robins TRANSNUCLEAR INC.

7135 Minstrel Way Suite 300

  • Columbia, MD 21045 Tel: 410-910-6900 Fax: 410-910-6902 www.transnuclear.com

AFFIDAVIT PURSUANT TO 10 CFR 2.390 Transnuclear, Inc.

State of Maryland County of Howard I, Jayant Bondre, depose and say that I am a Vice President of Transnuclear, Inc., duly authorized to execute this affidavit, and have reviewed or caused to have reviewed the information which is identified as proprietary and referenced in the paragraph immediately below. I am submitting this affidavit in conformance with the provisions of 10 CFR 2.390 of the Commission's regulations for withholding this information.

The information for which proprietary treatment is sought is listed below:

TN Calculation 10494-174 Rev 0: Effect of Reversed Loading Patterns on the thermal Performance of 32PTH DSC.

This document has been appropriately designated as proprietary.

I have personal knowledge of the criteria and procedures utilized by Transnuclear, Inc. in designating information as a trade secret, privileged or as confidential commercial or financial information.

Pursuant to the provisions of paragraph (b) (4) of Section 2.390 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure, included in the above referenced document, should be withheld.

1)

The information sought to be withheld from public disclosure involves details and analyses related to Transnuclear, Inc.'s design for the NUHOMS 32PTH Dry Shielded Canister, which are owned and have been held in confidence by Transnuclear, Inc.

2)

The information is of a type customarily held in confidence by Transnuclear, Inc. and not customarily disclosed to the public. Transnuclear, Inc. has a rational basis for determining the types of information customarily held in confidence by it.

3)

Public disclosure of the information is likely to cause substantial harm to the competitive position of Transnuclear, Inc. because the information consists of details and analyses related to Transnuclear, Inc.'s design for the NUHOMS 32PTH Dry Shielded Canister, the application of which provide a competitive economic advantage. The availability of such information to competitors would enable them to modify their product to better compete with Transnuclear, Inc., take marketing or other actions to improve their product's position or impair the position of Transnuclear, Inc.'s product, and avoid developing similar data and analyses in support of their processes, methods or apparatus.

Further the deponent sayeth not.

Jeyn Bondr Vice President, Transnuclear, Inc.

0%

Subscribed and swom to me before this 21t day of June, 2011.

axy Public Lauren McKee NOTARY PUBLIC My Commission Expires Anne Arugdel County, Maryland 4'4' N~

jo My Com-mi-ssio-nfx-pires 2/12/2015 186a4,.sI,0" Page 1 of 1