1 NRR-PMDAPEm Resource From:

Lisa.Schofield@exeloncorp.com Sent:

Wednesday, September 28, 2011 3:00 PM To:

Mahoney, Michael Cc:

DiFrancesco, Nicholas Attachments:

Byron B2R16 Tubesheet Maps.pdf In support of tomorrow mornings call to discuss the Byron Unit 2 SG inspection results, attached are tubesheet maps showing the dent locations (new and historical).

Please note that the outline patterns that were added to Figures 3 and 4 are for the purpose of discussion.

If you have any questions prior to tomorrows call, please contact me.

Thank you, Lisa 630-657-2815

                                                                                                    • This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies. This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You. **************************************************

Hearing Identifier:

NRR_PMDA Email Number:

174 Mail Envelope Properties (B89765C774C10B4992D8F5806597A58A5EDA09)

Subject:

Sent Date:

9/28/2011 2:59:30 PM Received Date:

9/28/2011 3:00:25 PM From:

Lisa.Schofield@exeloncorp.com Created By:

Lisa.Schofield@exeloncorp.com Recipients:

"DiFrancesco, Nicholas" <Nicholas.DiFrancesco@nrc.gov>

Tracking Status: None "Mahoney, Michael" <Michael.Mahoney@nrc.gov>

Tracking Status: None Post Office:

cccmsxch13.energy.power.corp Files Size Date & Time MESSAGE 1255 9/28/2011 3:00:25 PM Byron B2R16 Tubesheet Maps.pdf 1126075 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

FIGURE 1: SG - B ALL NEW DENTS AT 03C

FIGURE 2: SG - B ALL DENTS AT 03C FROM 0 TO -1 INCH

FIGURE 3: SG - B ALL NEW DENTS AT 03C

FIGURE 4: SG - B ALL DENTS AT 03C FROM 0 TO -1 INCH