ML112780152

From kanterella
Jump to navigation Jump to search
Forwards LER 79-003/01T-0
Date released: 10/04/2019 Download: ML112780152


Forwards LER 79-003/01T-0
ML19263C990
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 03/15/1979
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19263C990 (1)
LER 79-003/01T-0 on 790301:containment Vent & Purge Isolation Valves Would Not Close During DBA-LOCA.Cause Unknown.Fisher Continential 18 & 20 Inch,Type 9220 Butterfly Valves Opening Is Administratively Controlled
ML112780151
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 03/15/1979
From: Goranson R
Northern States Power Co
To:
NRC/OI/RGN-III/FO
References
Download: ML112780151 (3)