UNITED STATES NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD


)(

In re:

License Renewal Application Submitted by Entergy Nuclear Indian Point 2, LLC, Entergy Nuclear Indian Point 3, LLC, and Entergy Nuclear Operations, Inc.


)(

Docket Nos. 50-247-LR; 50-286-LR ASLBP No. 07-858-03-LR-BDOI DPR-26, DPR-64 September 30, 2011 DECLARATION OF DR. JORAM HOPENFELD 1.

I have been retained by Riverkeeper, Inc. ("Riverkeeper") as an e)(pert witness in proceedings concerning the application by Entergy Nuclear Operations, Inc. ("Entergy") for the renewal oftwo separate operating licenses for the nuclear power generating facilities located at Indian Point on the east bank ofthe Hudson River in the Village ofBuchanan, Westchester County, New York, for twenty years beyond th~ir current e)(piration dates.

2.

I submit this declaration in support ofthe State ofNew York and Riverkeeper's New Joint Contention NYS-38/RK-TC-5, concerning Entergy's failure to demonstrate that it has all programs that are required to effectively manage the effects of aging of critical components or systems.

3.

My professional and educational qualifications are described in the curriculum vitae appended hereto as Attachment 1. Briefly summarized,*I am an e)(pert in the field relating to nuclear. power plant aging management. I am a mechanical engineer and hold a doctorate in mechanical engineering. I have 45 years ofprofessional e)(perience in the fields ofthermal-hydraulics, material/environment interaction instrumentation, design, project management, and nuclear safety regulation, including 18 years in the employ ofthe u.S. Nuclear Regulatory Commission ("NRC").

4.

My e)(tensive professional e)(perience has afforded me with knowledge and e)(pertise regarding the material degradation phenomenon known as "metal fatigue," that is, the fatigue or "cyclic stress" ofmetal parts due to repeated stresses during plant operation. Most recently, I was a technical consultant and e)(pert witness for the New England Coalition in the Vermont Yankee license renewal proceeding, where I testified at an adjudicatory hearing concerning metal fatigue.

1

5.

I reviewed the April 30, 2007 License Renewal Application ("LRA") submitted by Entergy to renew the operating licenses for Indian Point Units 2 and 3, and assisted Riverkeeper with the preparation of Contention TC-1, which challenged Entergy's aging management plan for addressing metal fatigue at Indian Point during the proposed period of extended operation.

6.

I reviewed Entergy's January 22, 2008 amendment to its original LRA, in which Entergy purported to provide additional information regarding its aging management program for addressing metal fatigue, and assisted Riverkeeper with the preparation ofan amended contention (Riverkeeper Contention TC1-A) to articulate the ongoing deficiencies with Entergy's plan to deal with metal fatigue.

7.

I reviewed Entergy's August 10, 2010 "Notification of Entergy's Submittal Regarding Completion of Commitment 33 for Indian Point Units 2 and 3," NL-10-082, as well as Entergy's revised metal fatigue evaluations dated June 2010, and assisted Riverkeeper with the preparation of a new and amended*contention (New York State 26-B/Riverkeeper TC-1B),

which articulated various deficiencies with Entergy's revised analysis, as well as Entergy's ongoing failure to demonstrate that the affects of metal fatigue would be adequately managed at Indian Point during the proposed period of extended operation.

8.

I have now reviewed NRC Staffs "Request for Additional Information for the Review ofthe Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application," dated February 10, 2011, Entergy's response thereto ("Response to Request for Additional Information (RAI), Aging Management Programs, Indian Point Nuclear Generating Unit Nos. 2 & 3, Docket Nos. 50-247 and 50-286, License Nos. DPR-26 and DPR-64," dated March 28, 2011), and NRC Staffs "Safety Evaluation Report Related to the License Renewal of Indian Point Nuclear Generating Unit Nos. 2 and 3, Supplement 1" dated August 2011 ("SER Supplement 1"), all of which implicate and discuss metal fatigue.. After a review ofthese documents, for the reasons explained more fully below, it remains my professional opinion that Entergy has, to date, failed to demonstrate that the affects ofmetal fatigue will be adequately managed at Indian Point during the proposed period of extended operation.

9.

NRC Staffs February 10, 2011 Request for Additional Information ("RAI")

requested that Entergy "[confirm and justify that the plant-specific locations listed in LRA Tables 4.3-13 and 4.3-14 are bounding for the generic NUREG/CR-6260 components" and

"[c]onflrm and justify that the locations selected for environmentally-assisted fatigue analyses in LRA Tables 4.3-13 and 4.3-14 consist ofthe most limiting locations for the plant (beyond the generic components identified in the NUREG/CR-6260 guidance)." In response, Entergy only indicated that the locations in LRA Tables 4.3-13 and 4.3-14 are the same as those locations provided in NUREG/CR-6260, and, in Commitment 43, promised to determine at some future point in time, though before entering the period of extended operation, whether the NUREG/CR-6260 locations evaluated are the limiting locations for the Indian Point plant configurations.

Entergy's reason for requiring additional time was the need to review "design basis ASME Code Class 1 fatigue evaluations."

10.

Entergy's RAI responses unacceptably fail to "confirm and justify" bounding and limiting locations for Indian Point. As I have previously stated (and as asserted in admitted 2

contention New York State 26-B/Riverkeeper TC-1B), it is necessary for Entergy to investigate other components because the Cufen values of several components in LRA Tables 4.3-13 and 4.3-14 exceeded unity. See, e.g., Declaration of Dr. Joram Hopenfeld in Support ofPetitioners State ofNew York and Riverkeeper, Inc.'s New and Revised Contention Concerning Metal Fatigue (September 9, 2010), at ~ 18. Additionally, NUREG-1801, Rev. 2, Generic Aging Lessons Learned (GALL) Report, at page X Ml-2, states that the sample set for fatigue calculations that consider the effects ofthe reactor water environment "should include the locations identified in NUREG/CR-6260 and additionalplant-specific component locations in the reactor coolant pressure boundary ifthey may be more limiting than those considered in NUREG/CR-6260." (emphasis added). Now NRC Staffhas conceded that there may be more limiting components, and that the Cufen values in LRA Tables 4.3-13 and 4.3-14 may not be bounding. NRC Staffs acceptance of Entergy's vague commitments to address these concerns at some point in the future was improper. Like Riverkeeper, the NRC now questions Entergy's claim that LRA Tables 4.3-13 and 4.3-14 (which list the same components as those identified in NUREG/CR-6260) represent limiting conditions for the entire plant. Therefore, according to the guidance of GALL, in order to have an adequate aging management program, Entergy must identify the locations that may be more limiting, and which will be the subject ofthe CUFen calculations, now, and not just articulate a plan to determine such locations later.

11.

Entergy's response that it "will review design basis ASME Code Class 1 fatigue evaluations" is not confirmation or justification that the locations selected for environmentally-assisted fatigue analyses in LRA Tables 4.3-13 and 4.3-14 consist ofthe most limiting locations for the plant. Entergy has, to date, not provided any analysis that would support a conclusion that that the Cufen values in LRA Tables 4.3-13 and 4.3-14 bound all other components at the plant. Entergy has not conducted the analysis that would be required to confirm and justify that the components in LRA Tables 4.3-13 and 4.3-14 are bounding. Nor is this a clearly defined calculation. To the contrary, there are numerous considerations and factors for determining the most limiting locations, and Entergy has demonstrably failed to provide any information about how this analysis will be performed.

12.

Such an analysis would require: assessment of experience at Indian Point as well as other pressurized water reactor (PWR) plants; identification ofall components that are susceptible to thermal fatigue (including but not limited to nozzles, reducers, mixing tees and bends in feed water lines, surge lines, spray lines, and volume control system lines); component screening in light ofthe J;1umerous parameters which are known to effect fatigue life (including the ratios ofthe local heat transfer coefficient the local material conductivity, wall thickness, fluid temperature, delta T, dissolved oxygen levels, flow velocities, number oftransients, magnitude and cycling frequency of surface temperatures and loads, and surface discontinuities). Moreover, thermal striping during stratification should be generally considered as these effect fatigue life. NUREG-1801, Generic Aging Lessons Learned (GALL) Report requires that environmental effects be included in the calculations and it does not exclude thermal striping from such requirements.

13.

This analysis must be performed before a determination is made about license renewal. NRC Staffs acceptance ofEntergy's commitment in SER Supplement 1 to determine 3

whether the NUREG/CR-6260 locations evaluated are the limiting locations for the Indian Point plant configurations at some time in the future is not warranted or acceptable.

14.

In light ofNRC Staffs acceptance of a vague commitment to perform necessary metal fatigue investigation and analyses in the future, Entergy has failed to demonstrate that it has a program to monitor, manage, and correct metal fatigue related degradation sufficient to comply with 10 C.F.R. § 54.21(c), or the regulatory guidance ofNUREG-1801, Generic Aging Lessons Learned (GALL) Report.

4

In acoordancewitb 28 U.S.C. §1746, I declare under penalty ofpetiury that the foregoing is true and correct.

F.1J.ecuted on~ -f. 2t!2,.201]

ATTACHMENT 1 To Declaration of Dr. Joram Hopenfeld in support of State of New York and Riverkeeper's New Joint Contention NYS-38/RK-TC-5 (September 30,2011)

Curriculum Vitae for Dr. Joram (Joe),Hopenfeld 1724 Yale PI., Rookvi])e, MD 20850 Tel: 301 340 1625

.A. Profes.sional Expertise:

a.

Nuclear Safety and Licensing (design basis/severe accidents)

b. Thermal/llydraulics (Transient Boiling, Jet Mixing, Reentry Heat transfer, molten metal/coolant interactions, pool fires, computer code developments)
c. MaterialslEn:vironment Interaction (colTosion, erosi()n~ stress corrosion, fatigue,.

cavitation, fouling)

,d. Radioactivity Transport (10 CFR Part 100 )

e.

Industrial Instrumentation and Environmental Monitoring.

B. Current Position

  • CEO,.NQverOo, Inc
c. Education - Engineering-University of California at Los Angeles: BS 1960, MS 1962, Ph.D 1967.

D. Summary ofWork Experience

1. Nuclear Plant Related Exp~rience I have 45 years ofexperience in industry and govenunent primarily in the areas ofthetmal hydraulics~

.materials, corrosion~ radioactivity transport~ instrumentation, PWR steam generator transient testing and accident,analysis. I have managed major in~emational programs on steam generator performance during steam generator tube ruptures. steam line and feed line breaks. Following a decade ofstudies and several Advisory Committee on Reactor Safety hearings, the Nuclear Regulatory Commission, ("NRC")

adopted my.poSition regarding the safety consequences ofoperating with degraded steam* g~nerator

tubes.

In 2001 the NRC initiated a major program on the effects ofsteam gene~ator tube degradation on plant safety ('see NRC website). I have consulted to law finns,and citizen groups regarding Steam Generators, Thermal Hydraulics, CotTosion, and Material Fatigue in cormection with license renewals and a power upgrades.

,1. NOD Nuelear Related Experience I am the owner and the CEO ofa small Maryland company, Nov~rfIo~ Noverflo is developing advanced '

fiber optic sensors for the oil & gas and the environmental moriitoring industries. In 2004 Noverflo has completed a three year program which was sponsored by the u.s. Department ofEnergy. The prograIn produced a new system for automatic tank gauging, which will be presented at the 2006 National, Petrochemicals and Refiners Association Maintenance Conference.

In 1994-1996 NQverflo has developed and commercialized a shutoffvalve for fuel tanks to comply with new EPA regulations.

E. BriefElttploymeDt History A. Recent Consulting

1. Winston & Strawn, 14'00 L St. Washington D.C 2001 Provided 8S$istance in connection with*the February 2000 steam generator event at Indian Point.
2. C..I0 Research and Education Foundation, Inc. 44Merrimac St. Newburyport, MA 2002-2003 Provided assistance in the preparation ofa 2.206 petition to the NRC and other matters in connection with steam generator problems at the Seabrook Station
3. California Earth Corps (Sabrina D. Venskus, Attorney at LaW,. Santa Monica~ CA) 2005

Provided testimony to the Public UtiIity Commission ofthe State ofCalifornia on behalfofCalifornia Earth Corps in* connection with the San Onofre steam generator replacement project.

4*. New E_gl.ad CoalitioD (Raymond'Shadis, Edgecomb, Maine 04556) 2005-2006

.Technical consultant and expert witness in connection with Vermont Yankee*power upr_e and life extension hearings before the Atomics Safety and Licensing Board. Prepare contentions and ~estify *before the Board.

B. Industry and Government Employment 1962-197I -Corrosion testing ofmaterials for the design and opemtion ofliquid metal cooled nuclear reactors. 'Modeling Tr~sient Boiling in water and sodium. Mc;>deling Sodium"Fires. Modeling destruction ofSNAP fuel rods on reentry into the earth atmosphere. Atomics International, Can03a Park,.Calif.

1911-1973-Participated in the resolution ofdesign issues as related to material" behavior in the Breeder rea~tor environment Atomic' Energy Commission 1973 ~ 1978 'Project Manager for the safety evaluation and testing ofsteam generators.for liquid metal reactors. Managed the development ofthermal-hydraulic computer codes such as COBRA.

ERDA/Department ofEnergy. Responsible for testing material compatibility and cavitation damage in sodium. D~velopment *ofacoustic leak ~etection systems for sodium/water reactions..

1978.- 1982 Project M'anager for the development ofmaterials and instrumentation for high temperature steam generators for fossil plants. Responsible for the resolution ofissues relating to.

corrosion/erosion and NOx ISOx emissions, Department ofEnergy.

1982 - 2001.Program manager for the resolution.ofvarious, thermal hydraulics,.material corrosion and safety issues primarily in relation to PWR steam generators. Nuclear Regulatory Commission.

Publications

In addition to numerous reports, 1have published 15 papers in peer-reviewed tecbnic81 journals in the areas ofthermal-hydraulics, corros.onl erosion, steam generator dose releases during accidents, steam explosio~s, sensors and ECM machining.

Peer Reviewe~

~'NewFiber Optic Based-Teclmology for Automatic Tank Gauging", Sensors,December 2006 2.

"Distributed Fiber Optic Sensors for Leak Detection In Landfill~", Proceeding ofSPIE Vol 3541 (1998) 3.

'~Continuous Automatic DetectioD.ofPipe Wall Thinning"~ ASME Proceedings ofthe 9th, International Conference on Offshore Mechanics and Arctic Engineering. Feb. 1990 4

Comments on "Assessment ofSteam ~xplosion Induced Cootaimnent Failures" Lettert~.the Editor, Nuclear Science and Engineering, Vol. 103, Sept. 1989 6.

"ExperienCe and Modeling ofRadioactivity Transport Following Steam Generator Tube Rupture", Nuclear Safety, 26,286, 1985 7.

"Simplified Correl~tions forthe-_Predictions ofNox Emissions from Power Plants~'. AlAA JoUrnal ofEnergy) Nov.-Dece) 1919 8.

"Grain Boundary Grooving ofType 3Q4 Stainless Steel in Armco Iron Due to Liquid Sodium Corrosion", Corrosion, 27, No.11, 428,.1971 9.

"Corrosion-of.Type 316-Stainless Steel with Surface Heat Flux in 1200 Flowing Sodium",

-Nuclear Engineering and Desigi1~ 12; 167-169, 1970 10.

."PredictiQn ofthe One Dimensional Cutting Gap in Electrochemical Machining", ASME Transaction, J. ofEngineering for Industry, pI00 (1969) 11.

"Electrochemical M~chining~ Prediction and Correlation ofProcess Variables", ASME Transactions, J. ofEngineering for Industryt 88:455-461, (1966) 12.

"Laminar Two-Phase Boundary Layers in Subcooled Liquid-s", J. ofApplied Mathematics and Physics (ZAMP), 15,.388*399 (1964)

13.

"Onset ofStabJe Film Boiling and the Foam Limit", Intemationalj. of~eat Transfer and.Mass Transfer, 6; 987-989 (1963) ) (co-author) 14

Operating Conditions ofBubble Chamber Liquids", The Review ofScientific Instruments, 34~

30S-309.(1963);co-author 15.

"Similar Solutions ofthe Turbulent Free Convention Boundary'Layer for an Electrically Conducting Fluid in'the Presen~e ofa Magnetic Field,"AJAA J. 1:718-719 (1965)

Not Peer Reviewed (Recent Publications Only)

I.

New Fiber Optic Based Technology for Aut~maticTank Gauging ( ATG), NPRA -.2006 Reliability and Maintenance Conference, May 2'3-26, San Antonio, TX

2. Automatic Tank Gauging: ANew Level of Accuracy; A New Device Promises Greater

. Aceuraey for Custody Tran.sfer by Combining Fiber. Optic Sensing with a Pressure.

Sensors Magazine, 12/01/06 3.

PlastieOptical Fiben Sensors Cor Industrial Process Controls and Environmental Monitoring, POF World West 2007, Ju~e 25-27. 2007 List ofPatents 1.

Au~omatic Shut-OffValve for Liquid Storage Tanks, S,~22,41.S

2. Method and Apparatus for Detecting the Presence ofFluids, 5,200,615

. 3. Sensors For Detecting Leaks~ 5,187,366

4. Method for Monitoring Thinning ofWalls and Piping Components 4,922,74
5. Method for Monitoring Thinning ofPipe Walls, 4,779,453 6.

Looped Fiber Optic Sensor for the Detection ofSubstances (5,828,798)

7. Coated Fiber Optic Sensor for. The Detection ofSubstances (5,982,959)
8. Method arid Apparatus for Analyzing Infonnation of'Sensors Provided Over Multiple

.Waveguides (6,870,607)

Honors 1.

Engineer ofDistinction - Published by Engineers Joint Council 2.' American men and Women in Science 3.

The Blackwall Award for Machine. Tools 4.

Member Sigma-Xi Professional Activities I.

Reviewed papers for the ASME Journal and the Journal of$ensors and Actuators 2.

Taught a c)ass on Diesel Engines at Montgomery College, Rockville, MD.

3'.

Served as a member ofa Railroad Committee that deveJopmenta standard for locomotive Fueling 4.

Funded and sponsored research and development work at the Engineering Department ofthe University ofVirginia. The research produced a novel method ~fmeasuring pipe wall thinning from erosion/corrosion