U.S. Department of Homeland Security FEMA Region I 99 High St., 5h Floor Boston, MA 02110-2320 0c0FFEMA August 16, 2011 NRC Headquarters Document Control Desk US Nuclear Regulatory Commission Washington, DC 20555-0001

Dear Madam/Sir:

Enclosed find a copy of the Final Report for the Norwich Host Community Reception Center Exercise that was conducted on July 16, 2011.

The State of Connecticut and Local Emergency Response Organizations successfully demonstrated their capabilities to implement their off-site radiological emergency response plans and procedures based on the evaluation of this exercise by the a team of Federal evaluators with final determinations made by the Regional Assistance Committee (RAC) Chairperson. There are no deficiencies, and there are no Areas Requiring Corrective Action as a result of this exercise.

State and local preparedness remains adequate to protect the health and safety of the public living in the vicinity of the Millstone Nuclear Power Station and provides reasonable assurance that appropriate measures can be taken off-site in the event of a radiological emergency.

If you have any questions regarding this matter, please contact Helen LaForge, Millstone Site Specialist, of my staff at (617) 956-7584.

Sincerely, Steve Colman Regional Assistance Committee Chair Enclosure cc: NRC HQ REP Branch Chief NRC HQ REP Project Officer www. fema.gov

Millstone Power Station Norwich Host Community Reception Center Exercise Exercise Date: July 16, 2011 Final Report: August 16, 2011 Radiological Emergency Preparedness Program

  • M Region I

This page intentionally left blank.

FEMA Exercise Report Millstone Power Station Licensee:

Dominion Nuclear Connecticut, Inc.

Exercise Date:

Report Date:

July 16,2011 August 16, 2011 U.S. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY RADIOLOGICAL EMERGENCY PREPAREDNESS REGION I 99 HIGH STREET BOSTON, MASSACHUSETTS 02110

I I

This page intentionally left blank.

TABLE OF CONTENTS PAGE I.

EX EC U TIV E SU M M A R Y................................................................................................

1 II.

IN TR O D U C TIO N......................................................................................................

2 III.

EXERCISE EVALUATION AND RESULTS...........................................................

4 List of Appendices APPENDIX 1 - EXERCISE EVALUATORS..........................................................................

7 APPENDIX 2 - EXTENT OF PLAY........................................................................................

8 APPENDIX 3-EXERCISE SCENARIO...............................................................................

23 i

II I

I I

I I

This page intentionally left blank.

I I

I

I. EXECUTIVE

SUMMARY

On July 16, 2011, the Federal Emergency Management Agency (FEMA), Region I, conducted a Host Community Reception Center Exercise in Norwich, Connecticut. This exercise was conducted at the Host Community Reception Center at the Norwich State Technical High School. The exercise began at the Norwich Police Dispatch, continued at the Norwich Host Community Emergency Operation Center, and then at the Norwich Reception Center.

The purpose of this exercise was to assess the capability of the Norwich Host Community, Emergency Management Response Organizations, Fire Department Personnel, and Volunteers to respond to a radiological incident involving the Millstone Power Station. The exercise was held in accordance with FEMA's policies and guidance concerning the exercise of State and Local Radiological Emergency Response Plans (RERP) and procedures.

FEMA wishes to acknowledge the efforts of the many individuals who participated in this exercise.

Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. Cooperation and teamwork of all the participants was evident during this exercise.

This report contains the final evaluation of the Norwich Host Community Emergency Operation Center and Reception Center Exercise.

The Norwich Host Community, Emergency Management Response Organizations, Fire Department Personnel, and Volunteers successfully demonstrated their knowledge to implement their emergency response plans and procedures. There are no deficiencies. There are no Areas Requiring Corrective Action.

I

I II.

INTRODUCTION On December 7, 1979, the President directed FEMA to assume the lead responsibility for all offsite nuclear planning and response. FEMA's activities are conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351, and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

FEMA Rule 44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation in joint exercises with licensees.

FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

Taking the lead in the review and evaluation of RERPs and procedures developed by State and local goverhlments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments;

  • Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993);

and

  • Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:

I U.S. Department of Commerce U.S. Nuclear Regulatory Commission I

U.S. Environmental Protection Agency U.S. Department of Energy U.S. Department of Health and Human Services I

U.S. Center for Disease Control U.S. Department of Transportation U.S. Department of Agriculture U.S. Department of the Interior U.S. Food and Drug Administration Representatives of these agencies serve on the FEMA Region I Regional Assistance Committee (RAC), which is chaired by FEMA.

23

Formal submission of the RERPs for the Millstone Power Station to FEMA Region I by the State of Connecticut and involved local jurisdictions occurred in 1982. Formal approval of the RERP was granted by FEMA in October 1984, under 44 CFR 350.

The findings presented in this report are based on the evaluations of the federal evaluator team, with final determinations made by the FEMA Region I RAC Chairperson.

The criteria utilized in the FEMA evaluation process are contained in NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980;

  • 67 FR 20580, "FEMA Radiological Emergency Preparedness: Exercise Evaluation Methodology," September 12, 2001 and amended April 25, 2002.

Section III of this report, entitled "Exercise Evaluation and Results," presents detailed information on the demonstration of applicable exercise objectives at each jurisdiction or functional entity evaluated in a jurisdiction-based format.

3

I III. EXERCISE EVALUATION AND RESULTS Participating Agencies City of Norwich (Human Services, Education, Public Utilities, Public Works)

I Norwich City Manager Norwich Office of Emergency Management East Great Plain Fire Department Laurel Hill Fire Department Occum Fire Department Taftville Fire Department Yantic Fire Department Norwich Police Department Uncas Health District American Ambulance Service, Inc.

Norwich Technical High School I

Norwich Community Emergency Response Team (CERT)

American Red Cross, Connecticut Chapter, Area 4 CT Department of Emergency Services & Public Protection, Division ?f Emergency Management i

& Homeland Security CT Department of Energy & Environmental Protection, Radiation Division CT Disaster Behavioral Health Response Network CT Department of Developmental Services Dominion Millstone. Emergency Preparedness Individual Volunteers from Connecticut Towns Federal Emergency Management Agency Contained in this section are the results and findings of the evaluation of the Norwich Host I

Community Reception Center Exercise that was conducted on July 16, 2011. The purpose of the Exercise was to test the capabilities of the reception center staff and the adequacy of the Host Community's Plan to be able to respond to an incident involving the Millstone Power Station.

The following is the status of functional entities evaluated at the Norwich Host Community Emergency Operation Center and Norwich Host Community Reception Center. Please note:

although both facilities were new, staff operated as though there was no change in facility. They were all very focused on the job at hand.

A. Norwich Host Community Emergency Operation Center This successful exercise began at the 9-1-1 Emergency Dispatch where the initial exercise telephone call was received and immediately communicated the Norwich Emergency Management Director.

Norwich Host Community staff were notified to report to the Norwich Emergency Operation Center (EOC). The Norwich EOC staff arrived without delay to the Norwich Emergency Operation Center where leadership was evident by the Norwich Emergency Management Director and Norwich Community Officials. Direction and control was maintained exceptionally well by the Norwich 4

I

Emergency Management Director. All EOC sections gave status updates on a regular basis and as new information came in. When the decision was given by the State to activate the Reception Center staff, this was met immediately with clear communication from the Norwich EOC.

The Norwich EOC staff demonstrated their knowledge and referred to plans and procedures to ensure all was in accordance to the Host Community Reception Center Plans and Procedures. This is truly a model EOC.

a.

MET: 1.a.1, 1.b.1, 1.c.1, 1.d.1, 1.e.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAs RESOLVED: NONE

f.

PRIOR ARCAs UNRESOLVED: NONE B. Norwich Host Community Reception Center The Incident Commander and the Reception Center Manager at the Norwich Host Community Reception Center both demonstrated excellent direction and control with excellent communication skills with all Reception Center staff. The initial briefing by the Incident Commander was thorough, setting the stage for a great start. The Reception Center Manager demonstrated excellent management skills throughout the Reception Center and continued throughout the entire exercise.

Excellent leadership.

Each and every member of the Reception Center staff was very knowledgeable and engaged in their position responsibilities. They successfully demonstrated knowledge of their plans and procedures.

The staff was made up of various emergency response entities and volunteer organizations; they worked together exceptionally well and demonstrated excellent teamwork. ALL staff were very proactive at each task at hand throughout the exercise. This was a truly successful Reception Center operation.

a.

MET: I.a.1, 1.b.1, 1.c.1, 1.d.1, 1.e.1, 3.a.1, 3.b.1, 3.d.1, 6.a.1, 6.b.1, 6.c.1

b.

DEFICIENCY: NONE

g.

AREAS REQUIRING CORRECTIVE ACTION: NONE

h.

NOT DEMONSTRATED: NONE

i.

PRIOR ARCAs RESOLVED: NONE 5

j.

PRIOR ARCAs UNRESOLVED: NONE PLANNING ISSUE NO.: 38-11-1.e.1-P-1 CRITERION: Equipment and supplies to support operations. Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations.

I (NUREG-0654, H., J. 1O.a. b. e. f.j. k., 11, K.3.a.)-

CONDITION: Two evacuees came into the Reception Center (RC) by way of the Reception Center i

rear exit door.

POSSIBLE CAUSE: No signage on the outside of the exit door. The person manning the door i

stepped away (which could happen in real life situation.)

REFERENCE:

HCP-5.2, Rev 5/11, Attachment 3, Figure 9; NUREG-0654, H., J.10.a. b. e. f. j. k.,

11, K.3.a.)

EFFECT: Without proper signage, evacuees could inadvertently cause contamination of a clean area.

CORRECTIVE ACTION DEMONSTRATED: Through the direction of the RC Manager, the two evacuees were instructed to stop in place; they followed instructions perfectly. ARC emergency worker was instructed to mop the floor with a maslin covered mop.where the two evacuees had.

walked as a precaution. The radiological officer was instructed to scan the evacuees for radiological contamination. There was no contamination found. All was successfully demonstrated by the RC emergency workers. Immediately following the exercise, an independent initiative was taken to I

create the additional signage and it has since been added to the HC RC supply kit.

i

APPENDIX 1 Norwich Host Community Evaluator Matrix EVALUATION OBSERVER/

AREA CRITERION LOCATION EVALUATOR Norwich HC EOC Helen LaForge Mobilization, Facilities, 1.a.1, 1.b.1, Communications, Direction 1.c.1, 1.d.1,

& Control, Equipment &

1.e.1 Supplies Norwich Reception Helen LaForge Mobilization, Facilities, 1.a. 1, 1.b. 1, Center (RC)

Brian Kennedy (OJT)

Communications, Direction 1.c. 1, 1.d. 1,

& Control, Equipment &

i.e. 1 Supplies Norwich RC Don Carlton Dosimetry Issue & Briefing; 3.a. 1, 6.a. 1 Emergency Worker Dosimeter Norwich RC Bob Swartz Portal Monitoring 6.a. 1 Don Carnton Secondary Monitoring 6.a. 1 Norwich RC Pat Foster Evacuee Monitoring and 3.a. 1, 6.a. 1 Don Carlton Decontamination (female/male respectively)

Norwich RC Melissa Savilonis Evacuee Registration 6.a. 1 Norwich RC Melissa Savilonis Implement KI Decision 3.b. I Norwich RC Barbara Thomas Traffic Control Around 3.d. 1 Reception Area; Vehicle Monitoring and 6.b. 1 Decontamination Norwich Congregate Helen LaForge Temporary Care of 6.c. 1 Care Facilities Evacuees 7

I APPENDIX 2 Extent of Play State of Connecticut & Millstone Station Norwich Host Community Evaluation Area 1 - Emergency Operations Management 3

Sub-element l.a.1. Mobilization.

Criterion 1.a.1: Off-site Response organization use effective procedures to alert, notify, and mobilize emergency personnel and activate facilities in a timely manner. (NUREG-0654, A.4.,

D.3., 4., E.I., 2., H.4)

Intent This sub-element is derived from NUREG-0654 which' provides that OROs Should have the I

capability to alert, notify, and mobilize emergency personnel and to activate and staff emergency facilities.

1EXTENT OF PLAY - GENERAL Responsible OROs should demonstrate the capability to receive notification of an emergency situation from the licensee, verify the notification, and contact, alert, and mobilize key emergency personnel in a timely manner. In addition, responsible OROs should demonstrate the activation of facilities for immediate use by mobilized personnel when they arrive to begin emergency operations.

Activation of facilities should be completed in accordance with the plan and/or procedures. Pre-positioning of emergency personnel is appropriate, in accordance with the extent of play agreement, at those facilities located beyond a normal commuting distance from the individual's duty location or residence. Further, pre-positioning of staff for an out-of-sequence demonstration is appropriate in accordance with the extent of play agreement.

1 All activities must be based on the ORO's plans and procedures, and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1. The Norwich Host Community will be mobilized by phone call or controller message from 3

the State Region 4 Coordinator via 9-1-1 Emergency Dispatch to the Norwich Emergency Management Director.

2. Turnover between the EOC and the Reception Center will be demonstrated.
3. Activation of congregate care facilities will be simulated.
4. Fire Department personnel may be prepositioned at a nearby location.
5. Additional responders from outside the immediate area, to include American Red Cross, may be prepositioned at a nearby location.

Areas Requiring Corrective Action (ARCA)

I NONE 8

Evaluation Area 1 - Emergency Operations Management Sub-element 1.b. 1. Facilities.

Criterion 1.b.l: Facilities are sufficient to support the emergency response. (NUREG-0654, H)

Intent This sub-element is derived from NUREG-0654, which provides that OROs should have facilities to support emergency response.

EXTENT OF PLAY-GENERAL Facilities will only be specifically evaluated for this criterion if they are new or have substantial changes in structure or mission.

Responsible OROs should demonstrate the availability of facilities that support the accomplishment of emergency operations. Some of the areas to be considered are: adequate space, furnishings, lighting, restrooms, ventilation, backup power and/or alternate facility (if required to support operations).

All activities must be based on the ORO's plans and procedures, and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1. The Norwich EOC isa new facility and will be evaluated.
2. Norwich State Technical High School has not been used as a Reception Center in the past and Will be evaluated.

Areas Requiring Corrective Action (ARCA)

NONE 9

Evaluation Area 1 - Emergency Operations Management Sub-element ie. 1. Direction and Control.

Criterion 1.c.1: Key personnel with leadership roles for the Off-Site Response Organization provide direction and control to that part of the overall response effort for which they are responsible. NUREG-0654, A.A.d., 2.a., b.)

Intent This sub-element is derived from NUREG-0654, which provides that the ORO have the capability to control their overall response to an emergency.

EXTENT OF PLAY - GENERAL Leadership personnel should demonstrate the ability to carry out essential functions of the response efforts for example; keeping the staff informed through 'periodic briefings and/or other means, coordinating with other appropriate OROs and ensuring completion of requirements and requests.

All activities associated with direction and control must be performed based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1. The Reception Center Manager will be in command at the Reception Center, and will report to the Fire Department Incident Commander.

Areas Requiring Corrective Action (ARCA)

NONE I

I I

I I

I I

I I

I I

I I

I I

I 10

Evaluation Area 1 - Emergency Operations Management Sub-element 1.d. 1. Communications and Equipment.

Criterion 1.d.l: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations.

Communications capabilities are managed in support of emergency operations. (NUREG-0654, F.1., 2.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs should establish reliable primary and backup communication systems to ensure communications-with key emergency personnel at locations, such as the following: appropriate contiguous governments within the, emergency planning zone (EPZ), Federal emergency response organizations, the licensee and its facilities,, emergency operations centers (EOC), and field teams.

EXTENT, OF PLAY GENERAL OROs will demonstrate: -that a primary, and at least., one backup system, are fully functional. at the beginning of an exercise. If a communications system or-systems are not functional, but exercise performance is not affected, no exercise issue will be assessed.

Communications equipment and procedures for facilities and field units should be used as needed for the transmission and receipt of exercise messages. All facilities and field teams should have the capability to access at least one communication system that is independent of the commercial telephone system. Responsible OROs should demonstrate the -capability to manage the communication systems and ensure that all message traffic is handled without delays that might disrupt the conduct of emergency operations.. OROs should ensure that a coordinated communication link for fixed and mobile medical support facilities exist.

The specific communications capabilities of OROs should be commensurate with that specified in the response plan and/or procedures.

Exercise scenarios could require the failure of a communications system and the use of an alternate system.

All activities associated with the management of communications capabilities must be demonstrated based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1.

Communications checks will be demonstrated throughout the Reception Center, and between Norwich Emergency Management and the Region 4 Office, and between the EOC and the Reception Center.

2.

Immediate correction of performance issues relating to communications and equipment where remediation is possible will be allowed. (That portion of the criterion that deals with performance only. Actual communication equipment cannot be re-demonstrated.)

Areas Requiring Corrective Action (ARCA)

NONE 11

  • r

Evaluation Area 1 - Emergency Operations Management Sub-element 1.e. I. Equipment And Supplies To Support Operations.

Criterion 1.e.l:

Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operations. (NUREG-0654, H., J.10.a.b.e.f.j.k, 11, K.3.a.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs have emergency equipment and supplies adequate to support the emergency response.

I EXTENT OF PLAY - GENERAL Equipment within the facility(ies) should be sufficient and consistent with the role assigned to that i

facility in the ORO's plans and/or procedures in support of emergency operations. Use of maps and displays is encouraged.

All instruments, including air sampling flow meters (field teams only), should be inspected, inventoried, and operationally checked before each use. They should be calibrated in accordance with the manufacturer's recommendations (or at leastannually for the unmodified CDV-700 series or if there are no manufacturer's recommendations for a specific instrument; modified CDV-700 instruments should be calibrated in accordance with the recommendation of the modification manufacturer.). A label indicating such calibration should be on each instrument or verifiable by other means. Note: Field team equipment is evaluated under 4.a. 1; radiologi cal laboratory equipment under 4.c. 1; reception center and emergency worker facilities' equipment is evaluated under 6.a. 1; and ambulance and medical facilities' equipment is evaluated under 6.d. 1.

Sufficient quantities of appropriate direct-reading and permanent record dosimetry and dosimeter chargers should be available for issuance to all categories of emergency workers that could be deployed from that facility. Appropriate direct-reading dosimeters should allow individual(s) to read the administrative reporting limits and maximum exposure limits contained in the ORO's plans and I

procedures.

Dosimeters should be inspected for electrical leakage at least annually and replaced, if necessary.

n CDV-138s, due to their documented history of electrical leakage problems, should be inspected for electrical leakage at least quarterly and replaced if necessary. This leakage testing will be verified during the exercise, through documentation submitted in the Annual Letter of Certification, and/or through a staff assistance visit.

Responsible OROs should demonstrate the capability to maintain inventories of KI sufficient for use 1

by emergency workers, as indicated on rosters; institutionalized individuals, as indicated in capacity lists for facilities; and, where stipulated by the plan and/or procedures, members of the general public (including transients) within the plume pathway EPZ.

I 12I

Sub-element i.e. 1. Equipment And Supplies To Support Operations. (Continued)

Quantities of dosimetry and KI available and storage locations(s) will be confirmed by physical inspection at storage location(s) or through documentation of current inventory submitted during the exercise, provided in the Annual Letter of Certification submission, and/or verified during a Staff Assistance Visit. Available supplies of KI should be within the expiration date indicated on KI bottles or blister packs. As an alternative, the ORO may produce a letter from FEMA indicating that the KI supply remains potent, in accordance with Food and Drug Administration (FDA) guidance.

FEMA issues these letters based upon the findings of the certified independent laboratory that performed the analysis at the ORO's request and expense.

At locations where traffic and access control personnel are deployed, appropriate equipment (e.g.,

vehicles, barriers, traffic cones and signs, etc.) should be available or their availability described.

All activities must be based on the ORO's plans and procedures and completed as they would be in an actual emergency, unl'ess noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1. A limited number of supplies (for demonstration purposes only) will be brought to the Reception Center.
2. Immediate correction will be allowed if initially not being able to show proper equipment, supplies, or documentation.

Areas Requiring Corrective Action (ARCA)

NONE 13

Evaluation Area 3 - Protective Action Implementation Sub-element 3.a. 1. Implementation of Emergency Worker Exposure Control.

The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to i

emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart. (NUREG-0654, K.3.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs should have the capability to provide for the following: distribution, use, collection, and processing of direct-reading dosimeters and permanent record dosimeters; provide for direct-reading dosimeters to be read at appropriate frequencies by emergency workers; maintain a radiation dose record for each emergency worker; and provide for establishing a decision chain or authorization procedure for emergency workers to incur radiation exposures in excess of protective action guides, always applying the i

ALARA (As Low As is Reasonably Achievable) principle as appropriate.

EXTENT OF PLAY - GENERAL i

OROs should demonstrate the capability to provide appropriate direct-reading and permanent record dosimetry, dosimetry chargers, and instructions on the use of dosimetry to emergency workers. For evaluation purposes. appropriate direct-reading dosimetry, is defined as dosimetry that allows l

individual(s) to read the administrative reporting limits (that are pre-established at a level low enough to consider subsequent calculation of Total Effective Dose Equivalent) and maximum exposure limits (for those emergency workers involved in life saving activities) contained in the OROs plans and procedures.

Each emergency worker should have the basic knowledge of radiation exposure limits as specified in the ORO's plan and/or procedures.

Procedures to monitor and record dosimeter readings and to manage radiological exposure control should be demonstrated.

During a plume phase exercise, emergency workers should demonstrate the procedures to be followed when administrative exposure limits and turn-back values are reached. The emergency worker should report accumulated exposures during the exercise as indicated in the plans and procedures.

OROs should demonstrate the actions described in the plan and/or procedures by determining whether to replace the worker, to authorize the worker to incur additional exposures or I

to take other actions. If scenario events do not require emergency workers to seek authorizations for additional exposure, evaluators should interview at least two emergency workers, to determine their knowledge of whom to contact in the event authorization is needed and at what exposure levels.

I Emergency workers may use any available resources (e.g. written procedures and/or co-workers) in providing responses.

Although it is desirable for all emergency workers to each have a direct-reading dosimeter, there may be situations where team members will be in close proximity to each other during the entire mission and adequate control of exposure can be affected for all members of the team by one dosimeter worn by the team leader. Emergency workers who are assigned to low exposure rate areas, e.g., at 14 i

Sub-element 3.a. 1. Implementation of Emergency Worker Exposure Control. (Continued) reception centers, counting laboratories, emergency operations centers, and communications centers, may have individual direct-reading dosimeters or they may be monitored by dosimeters strategically placed in the work area. It should be noted that, even in these situations, each team member must still have their own permanent record dosimeter.

Individuals without specific radiological response missions, such as farmers for animal care, essential utility service personnel, or other members of the public who must re-enter an evacuated area following or during the plume passage, should be limited to the lowest radiological exposure commensurate with completing their missions.

All activities must be. based on the ORO's plans and procedures and completed as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECjFIC

1.

Dosimetry packets will be issued to radiological emergency workers only. (Non-radiological emergency workers such as KI issue and registration staff will not be issued dosimetry.).

2.

Radiological emergency worker knowledge will be demonstrated through evaluator interviews.

3.

Immediate correction. of issues relating to exposure control where remediation is possible will be allowed.

Areas Requiring Corrective Action (ARCA)

NONE 15

Evaluation Area 3 - Protective Action Implementation Sub-element 3.b.1 - Implementation of KI Decision Criterion 3.b. 1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals is maintained. (NUREG-0654, E. 7, J. 10. e., f.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs should have the capability to provide radio-protective drugs for emergency workers, institutionalized individuals, and, if in the I

plan and/or procedures, to the general public for whom immediate evacuation may not be feasible, very difficult, or significantly delayed. While it is necessary for OROs to have the capability to provide KI to emergency workers and institutionalized individuals, the provision of KI to the general public is an ORO option, reflected in ORO's plans and procedures. Provisions should include the availability of adequate quantities, storage, and means of the distribution of radioprotective drugs.

EXTENT OF PLAY - GENERAL OROs should demonstrate the capability to make KI available to emergency workers, institutionalized individuals, and, where provided for in the ORO plan and/or procedures, to members of the general public. OROs should demonstrate the capability to accomplish distribution of KI consistent with decisions made. Organizations should have the capability to develop and maintain lists of emergency workers and institutionalized individuals who have ingested KI, including documentation of the date(s) and time(s) they were instructed to ingest KI. The ingestion of KI recommended by the designated ORO health official is voluntary. For evaluation purposes, the I

actual ingestion of KI is not necessary. OROs should demonstrate the capability to formulate and disseminate appropriate instructions on the use of KI for those advised to take it. If a recommendation is made for the general public to take KI, appropriate information should be I

provided to the public by the means of notification specified in the ORO's plan and/or procedures.

Emergency workers should demonstrate the basic knowledge of procedures for the use of KI whether I

or not the scenario drives the use of KI. This can be accomplished by an interview with the evaluator.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

16

I Sub-element 3.b.1 - Implementation of KI Decision (Continued)

I EXTENT OF PLAY - SPECIFIC

1. The supply of general public (evacuee) KI will be available for evaluator inspection, only a representative number of packets will be used for simulated distribution during the evaluated exercise.
2. Reception center staff will demonstrate the process, procedures and equipment for KI distribution and direction to ingest KI through discussion to simulated evacuees at the facility. KI will not be ingested by any drill participants.
3. Immediate correction of issues relating to procedures and distribution of KI where remediation is possible will be allowed.

Area Requiring Corrective Action (ARCA)

NONE 17

Evaluation Area 3 - Protective Action Implementation Sub-element 3.d. 1. Implementation of Traffic and Access Control -TCP/ACP are established.

Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel. (NUREG-0654, J.10.g, j., k.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs have the capability to implement protective action plans, including relocation and restriction of access to evacuated areas. This sub-element focuses on selecting, establishing, and staffing of traffic and access control points and removal of impediments to the flow of evacuation traffic.

EXTENT OF PLAY - GENERAL OROs should demonstrate the capability to select, establish, and staff appropriate traffic and access control points consistent with evacuation/sheltering decisions (for example evacuating, sheltering and relocation), in a timely manner. OROs should demonstrate the capability to provide instructions to traffic :and access control staff on actions to take when modifications in protective action strategies necessitate changes in evacuation patterns or in the area(s) where access is controlled.

Traffic and access control staff should demonstrate accurate knowledge of their roles and responsibilities. This capability may be demonstrated by actual deployment or by interview in accordance with the extent of play agreement.

In instances where OROs lack authority necessary to control access by certain types of traffic (rail, water, and air traffic), they should demonstrate the capability to contact the State or Federal agencies with authority to control access.

All activities must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless specified above or indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1.

Traffic control will be demonstrated by interview. Traffic control points, designated in the plan, will not actually be posted by the police.

2.

Immediate correction of issues relating to traffic access and control points where remediation is possible will be allowed.

'Area Requiring Corrective Action (ARCA)

NONE 18 I

I I

I I

i I

I I

I I

I I

Evaluation Area 6 - Support Operations/Facilities Sub-element 6.a. 1. Monitoring and Decontamination of Evacuees and Emergency Workers and Registration of Evacuees.

Criterion 6.a.l: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers. (NUREG-0654, J.10.h. K.5.b.)

Intent This sub-element is derived from NUREG-0654, which provides that OROs have the capability to implement radiological monitoring and decontamination of evacuees and emergency workers, while minimizing contamination of.the facility, and registration of evacuees at reception centers.

EXTENT OF PLAY -,GENERAL Radiological. monitoring, decontamination,, an registration facilities for evacuees/ emergency workers should be set up. and. demonstrated, as they would,be..in an actual. emergency or as indicated in the extent of play agreement. This would include adequite space for evacuees' vehicles. Expected demonstration should include 1/3 of the monitoring teams/portal monitors required to monitor 20% of the population allocated to the facility within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Prior to using a monitoring instrument(s), the monitor(s) should demonstrate the process of checking:the instrument(s) for proper 6peration'.

Staff responsible for the radiological monitoring of evacuees should demonstrate the capability to attain and sustain a monitoring productivity rate per hour needed to monitor the 20% emergency planning zone (EPZ) population planning base within, about 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. This monitoring productivity rate per hour is the number of evacuees that. can be monitored per. hour by the total complement of monitors using an appropriate monitoring procedure.

A minimum of six individuals per monitoring station should be monitored, using equipment and procedures specified in the plan and/or procedures, to allow demonstration of monitoring, decontamination, and registration capabilities. The monitoring sequences for the first six simulated evacuees per monitoring team will be timed by the evaluators in order to determine whether the twelve-hour requirement can be met.

Monitoring of 'emergency workers does not have to meet the twelve-hour requirement. However, appropriate monitoring procedures should be demonstrated for a minimum of two emergency workers.

Decontamination of evacuees/emergency workers may be simulated and conducted by interview. The availability of provisions for separately showering should be demonstrated or explained. The staff should demonstrate provisions for limiting the spread of contamination. Provisions could include floor coverings, signs and appropriate means (e.g. partitions, roped-off areas) to separate clean from potentially contaminated areas. Provisions should also exist to separate contaminated and uncontaminated individuals, provide changes of clothing for individuals whose clothing is contaminated, and store contaminated clothing and personal belongings to prevent further contamination of evacuees or facilities. In addition, for any individual found to be contaminated, procedures should be discussed concerning the handling of potential contamination of vehicles and personal belongings.

Monitoring personnel should explain the use of action levels for determining the need for decontamination.

They should also explain the procedures for referring evacuees who. cannot be adequately decontaminated for assessment and follow up in accordance with the ORO's plans and procedures.

Contamination of the individual will be determined by controller inject and not simulated with any low-level radiation source.

19

Sub-element 6.a. 1. Monitoring and Decontamination of Evacuees and Emergency Workers and Registration of Evacuees. (Continued)

The capability to register individuals upon completion of the monitoring and decontamination activities should be demonstrated.

The registration activities demonstrated should include the establishment of a registration record for each individual, consisting of the individual's name, address, results of monitoring, and time of decontamination, if any, or as otherwise designated in the plan. Audio recorders, camcorders, or written records are all acceptable means for registration.

EXTENT 1.

OF PLAY - SPECIFIC At least three of the four portal monitors assigned to Norwich will be demonstrated-two for personnel, one for vehicles (one portal monitor is required for personnel, one for vehicles).

2. At least one staff radiological monitor will demonstrate hand-held instrument monitoring techniques for personnel at the Secondary Monitoring Station.
3. If new survey meters are available, they may be used instead of CDV-700s for demonstration / training purposes only - their use will not be formally evaluated.
4. Contamination control measures and decontamination techniques for at least two males and two females will be simulated.

5.

6.

Vehicle monitoring will be demonstrated via portal monitoring, only.

A representative sample of replacement clothing resources will be available for decontaminated individuals in the male and female decontamination areas.

I I

I I

i I

I I

I I

I I

I I

I I

7. Immediate correction of issues relating to monitoring, decontamination and registration where remediation is possible will be allowed.
8. Special Needs decontamination will be demonstrated, but will not be formally evaluated.

Area Requiring Corrective Action (ARCA)

NONE 20

Evaluation Area 6 - Support Operations/Facilities Sub-element 6.b. 1. Monitoring and Decontamination of Evacuee Vehicles and Emergency Worker equipment.

Criterion 6.b. 1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles. (NUREG-0654, K.5.b)

Intent This sub-element is derived from NUREG-0654, which provides that OROs have the capability to implement radiological monitoring and decontamination of emergency worker equipment, including vehicles.

EXTENT OF PLAY - GENERAL The monitoring staff should demonstrate the capability to monitor equipment, including vehicles, for contamination in accordance with the ORO's plans and procedures. Specific attention should be given to equipment, including vehicles, that was in contact with individuals found to be contaminated. The monitoring staff should demonstrate the capability to make decisions on the need for decontamination of equipment including vehicles based on guidance levels and procedures stated in the plan and/or procedures.

The area to be used for monitoring and decontamination should be set up as it would be in an actual emergency, with 'all route markings, instrumentation, record keeping and contamination control measures in place. Monitoring procedures should be demonstrated for a minimum of one vehicle. It is generally not necessary to monitor the entire surface of vehicles. However, the capability to monitor areas such as air intake systems, radiator grills, bumpers, wheel wells, tires, and door handles should be demonstrated. Interior surfaces of vehicles that were in contact with individuals found to be contaminated should also be checked.

Decontamination capabilities, and provisions for vehicles and equipment that cannot be decontaminated, may be simulated and conducted by interview. All activities associated with this criterion must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC

1. Per the ORO plan, decontamination of evacuee vehicles is not an emergency function.

Contaminated vehicles will be segregated for later decontamination.

2. Decontamination capabilities and provisions for vehicles and equipment will be demonstrated by discussion.
3. No vehicle interiors will be monitored.
4. Immediate correction of issues relating to monitoring and decontamination of evacuees and emergency workers and equipment will be allowed.

Areas Requiring Corrective Action (ARCA)

None 21

I Evaluation Area 6 - Support Operations/Facilities Sub-element 6.c. 1 Temporary Care of Evacuees Criterion 6.c. 1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines (found in MASS CARE-Preparedness Operations, ARC 3031). Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities. (NUREG-0654, J. 10.h.

12.)

Intent I

This sub-element is derived from NUREG-0654, which provides that OROs demonstrate the capability to establish relocation centers in host areas. Congregate care is normally provided in support of OROs by the American Red Cross under existing letters of agreement.

EXTENT OF PLAY - GENERAL Under this criterion, demonstration of congregate care centers may be conducted' out of sequence with the exercise scenario. The evaluator should conduct a walk-through of the center to determine, through observation and inquiries, that the services and accommodations are consistent with ARC 3031 In this simulation, it is not necessary to set up operations, as they would be in an actual emergency.

Alternatively, capabilities may be demonstrated by setting up stations for various services and providing those services to simulated evacuees.

Given the substantial differences between I

demonstration and simulation of this criterion, exercise demonstration expectations should'be clearly specified in extent-of-play agreements.

Congregate care staff should also demonstrate the capability to ensure that evacuees have been monitored for contamination, have been decontaminated as appropriate, and have been registered before entering the facility. This capability may be determined through an interview process.

If operations at the center are demonstrated, material that would be difficult or expensive to transport (e.g., cots, blankets, sundries, and large-scale food supplies) need not be physically available at the facility(ies). However, availability of such items should be verified by providing the evaluator a list of sources with locations and estimates of quantities.

All activities associated with this criterion must be based on the ORO's plans and procedures and completed, as they would be in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

EXTENT OF PLAY - SPECIFIC 1, Activation of congregate care facilities will be simulated on the day of the exercise.

Areas Requiring Corrective Action (ARCA)

None 22

APPENDIX 3 NORWICH HOST COMMUNITY Millstone Exercise Scenario/Timeline 23

0745 Dispatch Center l.a.l Mobilization MESSAGE #1 (Initial Notification)

DEMHS Region 4 Control Cell To Norwich Dispatch/EMD DEMHS Region 4 Office-'

Message from a simulated DEMHS Region 4 Coordinator (control cell) to notify Norwich Host Community via telephone call of declared Site Area Emenrgency.

Norwich Dispatch receives call, takes message and makes notification calls per their procedure.

0800-0815 l.a. I Dispatch Norwich Dispatcher makes call to EMD/designee. EMD Center authorizes "call-out" of EOC staff.

Mobilization 0815-0900 No Evaluation EOC Staff begins to arrive at EOC.

0830 -0900 f.d.I EOC MESSAGE #2 Fol

" Following EOC activation, communication checks are conducted Commniction an with simulated Region 4 Office (controller cell).

Communications and

~~EOC Controller "hsi rl"wl e

d:I omnctos Equipment To "Ti sadil ii eused during al radiocomnatns Norwich EOC 0900 I.c.l EOC MESSAGE #3 The simulated Region 4 Coordinator (controller) provides update D

ainformation on the declared General Emergency at Millstone Direction and Control DEMHS Region 4 directing Norwich Host Community EOC Director to prepare the Control Cell Reception Center to receive evacuees.from the designated EPZ To towns.

Norwich.EOC.

The total 20% population count used for Groton City (10,000 total) and Groton Town (29,900) in the plan is 7,980 for planning purposes and sheltering.

L.b. I EOC Primary Displays in the EOC consist of Emergency Classification Facilities Level table, Shelter status Board, Evacuation NMlap, Local Traffic Map and Shift Sign-in Board.

24

=

=

=

=

=

1 1-

=

=

=

M

=

=

M M

=

M

=

M

=

m m

M m

APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION 0900TII EOC The EMD requests the Norwich Dispatcher to "tone-out" Norwich Fire Departments to activate the Reception Center at Norwich Technicai'High School.

0900-1000 3.d.

  • EOC MESSAGE #4 The Norwich Police Dept. is responsible for the town's Traffic Traffic Control BOGC ontroller Control from entry point to Reception Center.

To Implementation of traffic control including Traffic Control points (No Evaluation)

Norwich Police and potential impediments to traffic flow as they exist on the day Department of the drill will be conducted by discussion at the EOC.

0915 EOC MESSAGE #5 EMD/Director is notified by Region 4 Coordinator (Controller Region 4 Control Cell message) that the EPZ public is being advised to take KI tablets.

To I Norwich EOC Director "1

TheRed Cross and Education Department EOC representatives discuss plan for opening shelters.

These will be posted on the EOC shelter board.

EOC determines shelter needs for population expected. ARC representative and EOC Director may determine order of shelter opening based on availability, location and capacity of each facility.

EOC Red Cross calls out for Red Cross representatives to staff the Reception Center to assist with shelter assignment.

(Shelters will not be staffed for this demonstration.)

Red Cross prepares shelter management roster/plan.

At least one representative assists registration staff 25

APPROX.

EVAL.

LOCATION CONTROLLER ;

SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION with information on shelter availability at the reception center.

RECEPTION Reception Center Activation CENTER Norwich OEM and F;Ds distribute equipment and supplies to (Norwich reception center.

Technical H.S.)

Norwich (Taftville) F.D. also provides radio equipment and will provide traffic control at the vehicle monitoring and parking area only.

I.c. I The Incident Commander will be a ranking Taftville Direction and Control FD Officer and will maintain communications and contact between Reception Center locations and the Norwich EOC. The IC will be assisted by a Norwich OEM Officer designated as the Reception Center Manager. Once the command center.is established at the Reception Center, the Norwich EOC will cease to be the primary command center.

0915 -0930 I.e. I RECEPTION Following their briefing, Norwich OEM and FDs will begin to Equip and Supplies CENTER set-up,,the Reception Center.

3.a. I Dosimetry is prepared and dosimetry paperwork is initiated for, local Reception Center radiological Dosimetry emergency workers only. A PRD and 0-5R Self-reading dosimeters are issued. (The 0-200 R Dosimeter contained within the packet is not issued to

  • .host emergency workers petr procedure.)

3.d.I*

A Dosimetry briefing is provided to all Emergency workers Dosimetry Briefing during the dosimetry issue process. Female workers will be 26

=

M--

=I

=--

=----

M M

M M M M M M

M m

M M

M M

M APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION briefed on special limits for declared pregnant females.

The Radiological Officer will provide guidance as needed with radiological issues.

0945 - 1045 L.d. 1 RECEPTION Communication: Radio checks are conducted Comm. and Equip CENTER/

between Reception Center Manager and the Norwich EOC EOC. Communications checks at Reception Center between the Reception Center Manager and remote locations throughout RC are also conducted.

(Radio communications should begin and end with "This is a drill.")

0945 - 1045 6.a. 1*

RECEPTION Preparation of CDV-700 survey meters. Survey meters (CDV-CENTER 700) are operationally checked for issue to monitoring staff ready Mon/Decon.

Norwich for use. Hand surveys will be demonstrated at the Secondary Register Workers and Technical Monitoring area and Decontamination Areas. If newer meters are Evacuees High School available, they may be demonstrated, but will not be evaluated.

6.a. 1 RECEPTION PersonnelPortaI Monitors: Two portal monitors will be set up CENTER in the gymnasium and operationally checked with a 1 micro-curie MonlDecon.

check source. (These are staggered to prevent exiting evacuees Register Workers and from crossing paths to Secondary Monitoring or Registration Evacuees pathways.)

0945-1045 6.b.l*

RECEPTION Vehicle Monitoring/Decon.: One vehicle portal will be set up CENTER per diagram in High School parking lot.

Mon/Decon/

Clean and contaminated parking areas are shown in the vehicle Monitoring Equipment monitoring area diagram.

and Vehicles Vehicle/Equipment Decon. will take place by discussion only.

27

APPROX.'

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element.

PLAYER TION

.j,..

6.a.1*

A Secondary Monitoring Area will be established for manual Mon/Decon survey prior to decontamination or release to Registration.

Register Workers and Evacuees 0945 - 1045 RECEPTION Separate Decontamination Areas will be set up for CENTER 6.a. I

  • males and females within separate athletic locker rooms. Each has local-and full body decontamination M'on/Decon areas, i.e. hands, face and full body showers if Register Workers and necessary.

Evacuees Temporary clothing is issued as needed. A representative sample of temporary replacement clothing will be available at each decontamination area.

Special Needs Decontamination Area may be set up for demonstration purposes, but will not be evaluated.

6.a.I*

RECEPTION Local EPZ town/State Emergency Workers:

CENTERE n

Mon/Decon Emergency -workers who come to the host community are identified at the Portal Monitoring or Secondary Register Workers and Monitoring stations. These workers will have been Evacuees issued their own dosimetry. (Workers who alarm portal return their dosimetry to the designated contaminated side of the dosimetry issue table for monitoring, otherwise it is returned to clean side.)

6.a.l*

RECEPTION Post-Decontamination monitoring is located just past the CENTER decontamination areas prior to individuals exiting the Mon/Decon decontamination areas to go to registration. Personnel 28 M

=-

M m

M M--- M--- M M

MM

=

M

=

=

mm

=

M

=

=

=

=

=

n EVAL.

AREA Sub element CONTROLLER SCENARIO EVENT MESSAGE -to PLAYER rmonitoring.fornms, are c0i pleted and evacuees receive a green wrist band (if clean) and copy of personnel monitoring form prior to being directed t6 &he registration area.

Escorts are stationed just outside each decon area to assist in directing evacuees to the registration area.

Register Workers and Evacuees 0945-1045 RECEPTION CENTER 3.b.l*

Implement KI The RegistrationCoordinator will direct Registration and Ki Issue areas arid report to the Reception Center Manager.

The Norwich Human Services and Uncas Health District will be dispatched to set up KI Triage, KI Issue and Registration in the cafeteria of the Norwich Tech HS.

Uncas'Health District staff will have the responsibility of preparing for the issue of KI. A bin of KI tablets will be available for distribution, but will not actually be issued. (Candy may be substituted for actual tablets.)

0945 - 1045 6.a.l*

RECEPTION Nonvich Human Services will direct Evacuee Mon/Decon Registration with possible assistance from CERT volunteers for.directing traffic. Registration is Register Workers and conducted via face-to-face interview using written Evacuees-forms.

Norwich OEM will provide the means for data entry of information friom the forms using laptop computers.

RECEPTION The Red Cross will assist evacuees with shelter CENTER assignment as needed.

1000-1100 1.c.I RECEPTION Reception Center Manager Direction and Control CENTER nce Reception Center stations report their readiness S

EOC to the Reception Center Manager, the Reception Center Manager notifies the EOC that the Reception 29

APPROX.

EVAL.

LOCATION

'CONTROLLER SCENARIO EVENT TIME OF AREA M ESSAGE'to DEMONSTRA Sub element

-PLAYER TION

-Center is fully operational.

The EOC (or mobile command center) will continue to receive updates on status of Reception Center operations and reportthis information to the Region 4 Coordinator, once Reception Center is operational.

1100 RECEPTION When the Reception Center is ready to receive CENTER evacuees and EOC has been notified, the actual demonstration with will begin as evacuees arrive.

The Lead Controller will notify the evacuees to proceed by vehicle to Reception Center via the parking lot entrance identified in set up diagrams.

Volunteer evacueesmwill be provided identification packets for this purpose.

RECEPTION CENTER DEMONSTRATION PHASE/withbEOC minimally staffed.:

RECEPTION MESSAGE #6 Vehicle Monitoring 1100 6.a. I*, 6.b. I*

CENTER All arriving vehicles (marked as Evacuee Vehicles) will be Vehicle Controller directed throughthe portal monitor, logged if contaminated, Vehicle Monitoring &

To

?marked and, directed to park in a designated "clean" or Decontamination Vehicle Monitor Lead "contaminated" area as appropriate. (Vehicles may be those coming in from the EOC as well as volunteer evacuees.) Each vehicle driver will be given a "Host Community - Reception Traffic Control

,Center" information sheet.

1100 - 1200 6.b. 1*

RECEPTION At least two vehicles will be designated "contaminated" by M6n/Decon CENTER controller inject.

e E n Clean vehicles may be tagged/marked later if notified that the Register Equipment occupants were determined to be contaminated.

and Vehicles 30 m=

u-

=

M m=

mmm

=

m m

m m

=

nM-m

=

=

n

=

n-

=

=

m APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION I

I 1100- 1200 6.a.l

  • RECEPTION MESSAGE #7 Personnel Monitoring Mon/Decon/Regist.

CENTER Portal Monitor Controller All individuals (except Evaluators,, Controllers, Workers and Evacuees To Observers) entering the facility will be monitored..

Portal Monitor Emergency workers and special needs individuals, Aftenda -nts including parents with children may be given higher priority during monitoring.

Individuals wh6 alarm a portal monitor are directed to secondary monitoring for a whole-body hand survey with a CDV-700 survey meter.

. I Individuals who do not alarm the portal monitor receive a green wrist band as proof of monitoring, and are directed to registration via clean pathway.

RECEPTION A green wrist band 'on the hand from CENTER 0 p6ftalfm~nitoring, secondary monitoring or post decon monitoring indicates the individual is "clean" and can proceed to registration (green bingo marker is available as a backup).

1100- 1200 6.b. 1 RECEPTION MESSAGE #8 At least two individuals (one female, one male) will be Mon/Decon/Register CENTER Contingency "contaminated" per controller message. At least two of the contaminated individuals will be evacuated EPZ Emergency Equipment and Workers who will also be wearing dosilnetry issued prior to Vehicles Portal Controller to entering the Reception Center.

Portal Attendants The Emergency workers' dosimetry is removed, bagged and Contingency.message returned to the Dosimetry Issue/Return desk to be read and (capture dosimetry recorded prior to the emergency worker leaving the reception before it gets to center. A copy of the completed forn should be returned to the secondary monitoring) emergency worker.

31

APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION 1100- 1200 6.a. 1 RECEPTION MESSAGE #9 Vehicle Monitoring is notified of potential internal contamination CENTER Contingency of a vehicle (previously monitored as clean) so that it can be Mon/Decon/Register Secondary Monitoring tagged/marked for interior monitoring later e*,en if parked in a Workers and Evacuees Controller designated clean parking area. (Interior monitoring will not be 6.b. I*

to demonstrated.)

Mon/Decon/Register Secondary Monitor Monitoring results will be provided by the controller.

Equipment and Vehicles 6.a. l*

RECEPTION MESSAGE #10 As Convenient Portal Monitoring (pre-staged) demonstration: This Portal Monitor demonstration f-vill take place after the "normal" evacuees have Register Workers and Controller gone through.

Evacuees To The Controller will direct six individuals through each portal Portal Monitor monitor, one portal ata time for evaluation purposes. A Attendants controller and evaluator must be present for this portion of the demdnstration.

Portal monitor attendants shouldprovide clear direction for entering and exiting the monitors and ensure that step-offto clean areas. are maintained. Controller should also time the walkthrough and record results. Populationsjbr each host are maintained in the HCP-4.6, Attachment 2.

1100- 1200 MESSAGE #11 Personnel Monitoring Forms are initiated at Secondary Secondary Monitor Monitoring to indicate the location and contamination levels for Controller action in the Decontamination areas.

ToSecondaryMoir

..To S rMonitor However, if secondary monitoring indicates no contamination, individual will receive a green bracelet and will be directed via clean pathway to Registration.

32

/----

m m

I--

m

m=

mn

=

=

=

=

=

=

m=

m n n

m

=

m APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER:....

TION Monitoring results will be provided by the controller.

6.a. I

  • RECEPTION Male/Female Decontamination Areas 11!00 - 1200MESG#2 Mon/Decon/Register CENTER MESSAGE #12 Decontamination staff review Personnel Monitoring Decon Area Controllers Workers and Evacuees Forms and advise/assist with decontamination via STo discussion.

Post-Decon Monitors

m If minimal local contamination is detected, nearby bathroom sinks may be utilized. Simple instructions may be posted over sink with an attendant nearby to assist and direct individuals to Post Decontamination Monitoring'.

If decontamination is successful at this point, individuals will receive a green wrist bracelet and will be directed to the Registration Area with a copy of their Personnel Monitoring Form. Monitoring results will be'provided by the controller.

If full shower is recommended, decontamination procedures will be described verbally. (All decontamination will be simulated.)

Temporary representative "coverings" will be available for demonstration.

Final monitoring results will be provided by the controller.

NOTE: Evacuees must exit decontamination areas 33

APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION through the clean path to registration. A traffic flow assistant should be stationed post decon to direct people to the doorway leading into the cafeteria.

3.b.

  • RECEPTION KI ISSUE Implement KI CENTER All volunteer evacuees will be directed to the Registration Area for processing in the cafeteria.
1. At KI Triage, evacuees will be asked if they have taken KI prior to arrival.
2. If YES, evacuees will be directed to Registration.
3. If NO, evacuees will be directed to KI Issue.

1100 - 1200 6.a. I RECEPTION Volunteer evacuees are interviewed/registered by registrars at the CENTER registration area.

Mon/Decon/Register Workers and Evacuees A green wrist band on the hand or completed Personnel Monitoring Form is proof of "non-contamination" and previously monitored/clean evacuees.

Registration isctompleted on hand-written forms by registrars.

Before leaying evacuees are also provided with decontamination advisory information either verbally or on a printed card.

A computer software program may be used to process information from the written form to create a database of information.

34 1M1 M-M----- M-M M

M

-1

=

M-m m

M

=-

=-

=

=-

=

M APPROX.

EVAL.

LOCATION CONTROLLER SCENARIO EVENT TIME OF AREA MESSAGE to DEMONSTRA Sub element PLAYER TION An 'infornnation area is located near the registration area to post messages given to registrars for reunification of family members.

RED CROSS Shelter infonnati6n and water are provided by Red Cross staff following registration. Evacuees will be directed to the Exit or Assistance Area the waiting area..

1200- 1230 RECEPTION MESSAGE #13 Exercise Termination CENTER When. all Reception Center objectives have been demonstrated to Lead Controller the satisfaction of evaluators, a controller message is issued to the To Reception Center Manager that Reception Center

-a Reepio.Cntr The Exercise is terminated. (The RC Mgr may choose to break SManager down areas as they complete their mission and return dosimetry and meters while other areas are still completing their activities.)

Play ends and all areas are returned to normal condition.

LL 1230 - 1300 RECEPTION Controllers collect all Players-will be directed to return their areas to a nornmal condition CENTER paperwork and provide and report to a specified area for their comments and lunch.