1 Davis-BesseNPEm Resource From:
CuadradoDeJesus, Samuel Sent:
Monday, June 20, 2011 5:02 PM To:
'custerc@firstenergycorp.com' Cc:
dorts@firstenergycorp.com
Subject:
FW: Davis Besse - RAI Responses Attachments:
DB SMP RAI Concerns.docx Cliff:
As discussed attached is a summary of some of the issues well like to discuss early next week on a conference call.
From: Lehman, Bryce Sent: Monday, June 20, 2011 4:53 PM To: CuadradoDeJesus, Samuel Cc: Auluck, Rajender; Sheikh, Abdul
Subject:
RE: Davis Besse - RAI Responses
- Samuel, Attached are the issues I would like to discuss with the applicant.
Bryce From: CuadradoDeJesus, Samuel Sent: Monday, June 20, 2011 2:00 PM To: Lehman, Bryce
Subject:
RE: Davis Besse - RAI Responses Hi Bryce:
I spoke with Abdul and Ill be scheduling the teleconference call to be early next week. Abdul will be sending me an e-mail summarizing his concerns on the RAI responses so I can forward them to the applicant and they can be prepared for the teleconference call. Can you do the same for yours?
- Regards, From: Lehman, Bryce Sent: Monday, June 20, 2011 8:01 AM To: Sheikh, Abdul; CuadradoDeJesus, Samuel Cc: Auluck, Rajender; Buford, Angela; Istar, Ata; Dan Naus
Subject:
RE: Davis Besse - RAI Responses I would also like to participate in the call to discuss RAI responses B.2.39-1 and -2.
- Thanks, Bryce From: Sheikh, Abdul Sent: Monday, June 20, 2011 7:36 AM To: CuadradoDeJesus, Samuel Cc: Auluck, Rajender; Buford, Angela; Lehman, Bryce; Istar, Ata; Dan Naus
Subject:
Davis Besse - RAI Responses
2 I will like to have a telephone call with the applicant about RAI B.22-1 thru B.22-4 responses. I think other persons in RASB will also like some clarifications on other structural RAIs.
Can you please arrange a conference call. I will be out of office from Tuesday afternoon thru Thursday this week.
Abdul
Hearing Identifier:
Davis_BesseLicenseRenewal_Saf_NonPublic Email Number:
99 Mail Envelope Properties (Samuel.CuadradoDeJesus@nrc.gov20110620170100)
Subject:
FW: Davis Besse - RAI Responses Sent Date:
6/20/2011 5:01:35 PM Received Date:
6/20/2011 5:01:00 PM From:
CuadradoDeJesus, Samuel Created By:
Samuel.CuadradoDeJesus@nrc.gov Recipients:
"dorts@firstenergycorp.com" <dorts@firstenergycorp.com>
Tracking Status: None
"'custerc@firstenergycorp.com'" <custerc@firstenergycorp.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1759 6/20/2011 5:01:00 PM DB SMP RAI Concerns.docx 25119 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
Davis-Besse SMP RAI Concerns RAI B.2.39-1 Part 1: We need more information on the core bore results and how they concluded there is no concern with the structural integrity. Applicant should be prepared to discuss the report referenced in the RAI response.
Part 2: We need more details in the commitment, specifically what will be done if the applicant cannot stop the leakage or the leakage begins again at a later date (e.g.
core bores, more frequent inspections, etc.).
RAI B.2.39-2 This should be a two-part solution: 1) concrete bores to verify past leakage did not degrade walls, 2) future actions to ensure leakage does not occur again. The applicant addressed part 1; however, they did not adequately address part 2. The applicant should commit to take actions to ensure the leak-chase system remains operable during the PEO (e.g. boroscopic inspections at an technically justifiable interval).