NIA-101.txt
- File created using WinMACCS version 3.4.5 10/29/2009 5:21:34 PM
- DCF_FILE - Identifies the DCF file to be used for the MACCS calculation DCF_FILE001
'f:\\NBixler\\WinMACCS Projects\\IndianPointPalla\\Data\\DOSDATA.INP'
- EANAM1 - Identifies the EARLY calculation MIEANAM1001
'EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES'
- ENDAT2 - control flag allowing execution of ATMOS and EARLY without CHRONC MIENDAT2001
.FALSE.
- IPLUME - dispersion code option MIIPLUME001 2
- NUMFIN - number of fine-grid subdivisions used by model MINUMFIN001 7
- IPRINT - amount of output desired MIIPRINT001 0
- POPFLG - is population uniform or defined by Site Data File.
PDPOPFLG001 FILE
- ORGNAM_DOSFAC, ORGFLG_DOSFAC - list of organs to be included in the calculations using DOSFAC DCF file MIORGDEF001 A-SKIN
.TRUE.
MIORGDEF002
'A-RED MARR'
.TRUE.
MIORGDEF003 A-LUNGS.TRUE.
MIORGDEF004 A-THYROIDH
.TRUE.
MIORGDEF005 A-STOMACH
.TRUE.
MIORGDEF006
'A-LOWER LI'
.FALSE.
MIORGDEF007 L-EDEWBODY
.TRUE.
MIORGDEF008
'L-RED MARR'
.TRUE.
MIORGDEF009
'L-BONE SUR'
.TRUE.
MIORGDEF010 L-BREAST
.TRUE.
MIORGDEF011 L-LUNGS.TRUE.
MIORGDEF012 L-THYROID
.TRUE.
MIORGDEF013
'L-LOWER LI'
.TRUE.
MIORGDEF014
'L-BLAD WAL'
.TRUE.
MIORGDEF015 L-LIVER.FALSE.
MIORGDEF016 L-THYROIDH
.TRUE.
- RISCAT - Output relative contribution of each weather category bins MIRISCAT001
.FALSE.
- OVRRID - Flag indicating if Wind Rose defaults from ATMOS are to be overridden MIOVRRID001
.FALSE.
- CSFACT - Cloudshine shielding factor SECSFACT001 1.
SECSFACT002 0.75 SECSFACT003 0.6
- PROTIN - Inhalation protection factor SEPROTIN001 1.
SEPROTIN002 0.41 SEPROTIN003 0.33
- BRRATE - Breathing rates SEBRRATE001 2.66E-4 SEBRRATE002 2.66E-4 SEBRRATE003 2.66E-4 Page 1
NIA-101.txt
- SKPFAC - skin protection factors SESKPFAC001 1.0 SESKPFAC002 0.41 SESKPFAC003 0.33
- GSHFAC - groundshine shielding factors SEGSHFAC001 0.5 SEGSHFAC002 0.4 SEGSHFAC003 0.2
- RESCON - Initial value for emergency-phase resuspension concentration factor.
SERESCON001 1.E-4
- RESHAF - Emergency-phase resuspension concentration coefficient weathering half-life.
SERESHAF001 1.82E5
- EANAM2 - Name of emergency response scenario EZEANAM2001
'NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE'
- WTNAME - type of weighting factor to be used in generating weighted sum of results EZWTNAME001 PEOPLE
- WTFRAC - weighting fraction applied to results of emergency response scenario EZWTFRAC001 1.00
- LASMOV2 (used for no evacuation), always 0 EZLASMOV001 0
- ENDEMP - duration of the emergency-phase period, seconds SRENDEMP001 604800.
- CRIORG - critical organ for relocation decisions during emergency-phase period SRCRIORG001 L-EDEWBODY
- TIMHOT - hot-spot relocation action time, seconds after plume arrival SRTIMHOT001 43200.
- TIMNRM - Normal Relocation Time (Seconds from Plume Arrival)
SRTIMNRM001 86400.
- DOSHOT - Hot-Spot Relocation Dose Threshold (Sieverts)
SRDOSHOT001 0.5
- DOSNRM - Normal Relocation Dose Threshold (Sieverts)
SRDOSNRM001 0.25
- NUMEFA - Number of Early Fatality Effects EFNUMEFA001 2
- ORGNAM2, EFFACA, EFFACB, EFFTHR Early Fatality Effects - target organ, alpha factor and beta factor for hazard function, and threshold dose (Sieverts)
EFATAGRP001
'A-RED MARR' 3.8 5.0 1.5 EFATAGRP002 A-LUNGS 10.0 7.0 5.0
- NUMEIN - Number of Early Injury Effects EINUMEIN001 7
- ORGNAM3, EINAME, EISUSC, EITHRE, EIFACA, EIFACB Early Injury Effects - name, target organ, affected population fract, threshold dose, alpha factor, beta factor.
EINJUGRP001
'PRODROMAL VOMIT' A-STOMACH 1.
.5 2.
3.
EINJUGRP002 DIARRHEA A-STOMACH 1.
1.
3.
2.5 EINJUGRP003 PNEUMONITIS A-LUNGS 1.
5.
10.
7.
Page 2
NIA-101.txt EINJUGRP004
'SKIN ERYTHEMA' A-SKIN 1.
3.
6.
5.
EINJUGRP005 TRANSEPIDERMAL A-SKIN 1.
10.
20.
5.
EINJUGRP006 THYROIDITIS A-THYROIDH 1.
40.
240.
2.
EINJUGRP007 HYPOTHYROIDISM A-THYROIDH 1.
2.
60.
1.3
- NUMACA - number of latent cancer effects LCNUMACA001 7
- ACTHRE - dose threshold for linear dose response, Sieverts LCACTHRE001 0.0
- DDTHRE - dose threshold for applying dose-dependent reduction factor, DDREFA LCDDTHRE001 0.2
- ACNAME, ORGNAM4, ACSUSC, DOSEFA, DOSEFB, CFRISK, CIRISK, DDREFA - Latent Cancer Effects Parameters LCANCERS001 LEUKEMIA
'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002 BONE
'L-BONE SUR' 1.0 1.0 0.0 9.00E-4 0.0 2.0 LCANCERS003 BREAST L-BREAST 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 LCANCERS004 LUNG L-LUNGS 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005 THYROID L-THYROIDH 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006 GI
'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007 OTHER L-EDEWBODY 1.0 1.0 0.0 2.76E-2 0.0 2.0
- NUM1=0 TYPE1NUMBER 0
- NUM1 - Number of results of type 1 TYPE1NUMBER 4
- NAME1, I1DIS1, I2DIS1, CCDF1 - Health-Effect Cases TYPE1OUT001
'ERL FAT/TOTAL' 1 15 NONE TYPE1OUT002
'CAN FAT/TOTAL' 1 15 NONE TYPE1OUT003
'CAN FAT/TOTAL' 1 11 NONE TYPE1OUT004
'ERL FAT/TOTAL' 1 11 NONE
- NUM2=0 TYPE2NUMBER 0
- NUM3=0 TYPE3NUMBER 0
- NUM4=0 TYPE4NUMBER 0
- NUM4 - Number of results of type 4 TYPE4NUMBER 3
- I1DIS4, NAME4, CCDF4 - Average Individual Risk TYPE4OUT001 1
'ERL FAT/TOTAL' NONE TYPE4OUT002 2
'ERL FAT/TOTAL' NONE TYPE4OUT003 3
'ERL FAT/TOTAL' NONE
- NUM5 =0 TYPE5NUMBER 0
- NUM5 - Number of results of type 5 TYPE5NUMBER 1
- NAME5, I1DIS5, CCDF5 - Population Dose TYPE5OUT001 L-EDEWBODY 1
15 NONE Page 3
NIA-101.txt
- NUM6 =0 TYPE6NUMBER 0
- NUM7=0 TYPE7NUMBER 0
- NUM8=0 TYPE8NUMBER 0
- NUM8 - Number of results of type 8 TYPE8NUMBER 2
- NAME8, I1DIS8, I2DIS8, CCDF8 - Population-Weighted Risk TYPE8OUT001
'ERL FAT/TOTAL' 1 3
NONE TYPE8OUT002
'CAN FAT/TOTAL' 1 11 NONE
- NUMA=0 TYPEANUMBER 0
- NUMB =0 TYPEBNUMBER 0
- NUMB - Number of results of type B TYPEBNUMBER 20
- NAMEB, IRAD_B, IANG_B, CCDFB - Peak Dose at an (r, theta) Location TYPEBOUT001 L-EDEWBODY 1
1 NONE TYPEBOUT002 L-EDEWBODY 2
1 NONE TYPEBOUT003 L-EDEWBODY 3
1 NONE TYPEBOUT004 L-EDEWBODY 4
1 NONE TYPEBOUT005 L-EDEWBODY 5
1 NONE TYPEBOUT006 L-EDEWBODY 6
1 NONE TYPEBOUT007 L-EDEWBODY 7
1 NONE TYPEBOUT008 L-EDEWBODY 8
1 NONE TYPEBOUT009 L-EDEWBODY 9
1 NONE TYPEBOUT010 L-EDEWBODY 10 1
NONE TYPEBOUT011 L-EDEWBODY 1
9 NONE TYPEBOUT012 L-EDEWBODY 2
9 NONE TYPEBOUT013 L-EDEWBODY 3
9 NONE TYPEBOUT014 L-EDEWBODY 4
9 NONE TYPEBOUT015 L-EDEWBODY 5
9 NONE TYPEBOUT016 L-EDEWBODY 6
9 NONE TYPEBOUT017 L-EDEWBODY 7
9 NONE TYPEBOUT018 L-EDEWBODY 8
9 NONE TYPEBOUT019 L-EDEWBODY 9
9 NONE TYPEBOUT020 L-EDEWBODY 10 9
NONE
- NUMC=0 TYPECNUMBER 0
- NUMD = 0 TYPEDNUMBER 0
- DOSMOD, dose model, LNT, AT or PL LCDOSMOD001 LNT
- KIMODL, KI model EZKIMODL001 NOKI
- EFFACY, KI Ingestion EZEFFACY001 0.
- POPFRAC, KI Ingestion Page 4
NIA-101.txt EZPOPFRC001 0.
Page 5