  • File created using WinMACCS version 3.4.5 10/29/2009 5:21:34 PM
  • DCF_FILE - Identifies the DCF file to be used for the MACCS calculation DCF_FILE001

'f:\\NBixler\\WinMACCS Projects\\IndianPointPalla\\Data\\DOSDATA.INP'

  • EANAM1 - Identifies the EARLY calculation MIEANAM1001 'EARLY.IN, IPEC INPUT FROM THE EVACUATION TIME ESTIMATES'
  • ENDAT2 - control flag allowing execution of ATMOS and EARLY without CHRONC MIENDAT2001.FALSE.
  • IPLUME - dispersion code option MIIPLUME001 2
  • NUMFIN - number of fine-grid subdivisions used by model MINUMFIN001 7
  • IPRINT - amount of output desired MIIPRINT001 0
  • POPFLG - is population uniform or defined by Site Data File.

PDPOPFLG001 FILE

  • ORGNAM_DOSFAC, ORGFLG_DOSFAC - list of organs to be included in the calculations using DOSFAC DCF file MIORGDEF001 A-SKIN.TRUE.

MIORGDEF002 'A-RED MARR'.TRUE.

MIORGDEF003 A-LUNGS

.TRUE.

MIORGDEF004 A-THYROIDH

.TRUE.

MIORGDEF005 A-STOMACH

.TRUE.

MIORGDEF006 'A-LOWER LI'

.FALSE.

MIORGDEF007 L-EDEWBODY.TRUE.

MIORGDEF008 'L-RED MARR'.TRUE.

MIORGDEF009 'L-BONE SUR'

.TRUE.

MIORGDEF010 L-BREAST

.TRUE.

MIORGDEF011 L-LUNGS

.TRUE.

MIORGDEF012 L-THYROID

.TRUE.

MIORGDEF013 'L-LOWER LI'

.TRUE.

MIORGDEF014 'L-BLAD WAL'

.TRUE.

MIORGDEF015 L-LIVER.FALSE.

MIORGDEF016 L-THYROIDH

.TRUE.

  • RISCAT - Output relative contribution of each weather category bins MIRISCAT001

.FALSE.

  • OVRRID - Flag indicating if Wind Rose defaults from ATMOS are to be overridden MIOVRRID001.FALSE.

NIA-089

  • CSFACT - Cloudshine shielding factor SECSFACT001 1.

SECSFACT002 0.75 SECSFACT003 0.6

  • PROTIN - Inhalation protection factor SEPROTIN001 1.

SEPROTIN002 0.41 SEPROTIN003 0.33

  • BRRATE - Breathing rates SEBRRATE001 2.66E-4 SEBRRATE002 2.66E-4 SEBRRATE003 2.66E-4
  • SKPFAC - skin protection factors SESKPFAC001 1.0 SESKPFAC002 0.41 SESKPFAC003 0.33
  • GSHFAC - groundshine shielding factors SEGSHFAC001 0.5 SEGSHFAC002 0.4 SEGSHFAC003 0.2
  • RESCON - Initial value for emergency-phase resuspension concentration factor.

SERESCON001 1.E-4

  • RESHAF - Emergency-phase resuspension concentration coefficient weathering half-life.

SERESHAF001 1.82E5

  • EANAM2 - Name of emergency response scenario EZEANAM2001 'NO EVACUATION, RELOCATION MODELS APPLY EVERYWHE'
  • WTNAME - type of weighting factor to be used in generating weighted sum of results EZWTNAME001 PEOPLE
  • WTFRAC - weighting fraction applied to results of emergency response scenario EZWTFRAC001 1.00
  • LASMOV2 (used for no evacuation), always 0 EZLASMOV001 0
  • ENDEMP - duration of the emergency-phase period, seconds SRENDEMP001 604800.
  • CRIORG - critical organ for relocation decisions during emergency-phase period SRCRIORG001 L-EDEWBODY NIA-089
  • TIMHOT - hot-spot relocation action time, seconds after plume arrival SRTIMHOT001 43200.
  • TIMNRM - Normal Relocation Time (Seconds from Plume Arrival)

SRTIMNRM001 86400.

  • DOSHOT - Hot-Spot Relocation Dose Threshold (Sieverts)

SRDOSHOT001 0.5

  • DOSNRM - Normal Relocation Dose Threshold (Sieverts)

SRDOSNRM001 0.25

  • NUMEFA - Number of Early Fatality Effects EFNUMEFA001 2
  • ORGNAM2, EFFACA, EFFACB, EFFTHR Early Fatality Effects - target organ, alpha factor and beta factor for hazard function, and threshold dose (Sieverts)

EFATAGRP001 'A-RED MARR' 3.8 5.0 1.5 EFATAGRP002 A-LUNGS 10.0 7.0 5.0

  • NUMEIN - Number of Early Injury Effects EINUMEIN001 7
  • ORGNAM3, EINAME, EISUSC, EITHRE, EIFACA, EIFACB Early Injury Effects - name, target organ, affected population fract, threshold dose, alpha factor, beta factor.

EINJUGRP001 'PRODROMAL VOMIT' A-STOMACH

1.

.5

2.
3.

EINJUGRP002 DIARRHEA A-STOMACH

1.
1.
3.

2.5 EINJUGRP003 PNEUMONITIS A-LUNGS

1.
5.
10.
7.

EINJUGRP004 'SKIN ERYTHEMA' A-SKIN 1.

3.
6.
5.

EINJUGRP005 TRANSEPIDERMAL A-SKIN 1.

10.
20.
5.

EINJUGRP006 THYROIDITIS A-THYROIDH

1.
40.

240.

2.

EINJUGRP007 HYPOTHYROIDISM A-THYROIDH

1.
2.
60.

1.3

  • NUMACA - number of latent cancer effects LCNUMACA001 7
  • ACTHRE - dose threshold for linear dose response, Sieverts LCACTHRE001 0.0
  • DDTHRE - dose threshold for applying dose-dependent reduction factor, DDREFA LCDDTHRE001 0.2
  • ACNAME, ORGNAM4, ACSUSC, DOSEFA, DOSEFB, CFRISK, CIRISK, DDREFA - Latent Cancer Effects Parameters LCANCERS001 LEUKEMIA

'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002 BONE 'L-BONE SUR' 1.0 1.0 0.0 9.00E-4 0.0 2.0 LCANCERS003 BREAST L-BREAST 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 NIA-089

LCANCERS004 LUNG L-LUNGS 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005 THYROID L-THYROIDH 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006 GI

'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007 OTHER L-EDEWBODY 1.0 1.0 0.0 2.76E-2 0.0 2.0

  • NUM1=0 TYPE1NUMBER 0
  • NUM1 - Number of results of type 1 TYPE1NUMBER 4
  • NAME1, I1DIS1, I2DIS1, CCDF1 - Health-Effect Cases TYPE1OUT001 'ERL FAT/TOTAL' 1

15 NONE TYPE1OUT002 'CAN FAT/TOTAL' 1

15 NONE TYPE1OUT003 'CAN FAT/TOTAL' 1

11 NONE TYPE1OUT004 'ERL FAT/TOTAL' 1

11 NONE

  • NUM2=0 TYPE2NUMBER 0
  • NUM3=0 TYPE3NUMBER 0
  • NUM4=0 TYPE4NUMBER 0
  • NUM4 - Number of results of type 4 TYPE4NUMBER 3
  • I1DIS4, NAME4, CCDF4 - Average Individual Risk TYPE4OUT001 1

'ERL FAT/TOTAL' NONE TYPE4OUT002 2

'ERL FAT/TOTAL' NONE TYPE4OUT003 3

'ERL FAT/TOTAL' NONE

  • NUM5 =0 TYPE5NUMBER 0
  • NUM5 - Number of results of type 5 TYPE5NUMBER 1
  • NAME5, I1DIS5, CCDF5 - Population Dose TYPE5OUT001 L-EDEWBODY 1 15 NONE
  • NUM6 =0 TYPE6NUMBER 0
  • NUM7=0 TYPE7NUMBER 0 NIA-089
  • NUM8=0 TYPE8NUMBER 0
  • NUM8 - Number of results of type 8 TYPE8NUMBER 2
  • NAME8, I1DIS8, I2DIS8, CCDF8 - Population-Weighted Risk TYPE8OUT001 'ERL FAT/TOTAL' 1

3 NONE TYPE8OUT002 'CAN FAT/TOTAL' 1

11 NONE

  • NUMA=0 TYPEANUMBER 0
  • NUMB =0 TYPEBNUMBER 0
  • NUMB - Number of results of type B TYPEBNUMBER 20
  • NAMEB, IRAD_B, IANG_B, CCDFB - Peak Dose at an (r, theta) Location TYPEBOUT001 L-EDEWBODY 1 1

NONE TYPEBOUT002 L-EDEWBODY 2 1

NONE TYPEBOUT003 L-EDEWBODY 3 1

NONE TYPEBOUT004 L-EDEWBODY 4 1

NONE TYPEBOUT005 L-EDEWBODY 5 1

NONE TYPEBOUT006 L-EDEWBODY 6 1

NONE TYPEBOUT007 L-EDEWBODY 7 1

NONE TYPEBOUT008 L-EDEWBODY 8 1

NONE TYPEBOUT009 L-EDEWBODY 9 1

NONE TYPEBOUT010 L-EDEWBODY 10 1

NONE TYPEBOUT011 L-EDEWBODY 1 9

NONE TYPEBOUT012 L-EDEWBODY 2 9

NONE TYPEBOUT013 L-EDEWBODY 3 9

NONE TYPEBOUT014 L-EDEWBODY 4 9

NONE TYPEBOUT015 L-EDEWBODY 5 9

NONE TYPEBOUT016 L-EDEWBODY 6 9

NONE TYPEBOUT017 L-EDEWBODY 7 9

NONE TYPEBOUT018 L-EDEWBODY 8 9

NONE TYPEBOUT019 L-EDEWBODY 9 9

NONE TYPEBOUT020 L-EDEWBODY 10 9

NONE

  • NUMC=0 TYPECNUMBER 0
  • NUMD = 0 TYPEDNUMBER 0 NIA-089
  • DOSMOD, dose model, LNT, AT or PL LCDOSMOD001 LNT
  • KIMODL, KI model EZKIMODL001 NOKI
  • EFFACY, KI Ingestion EZEFFACY001
0.
  • POPFRAC, KI Ingestion EZPOPFRC001 0.

NIA-089