  • File created using WinMACCS version 3.4.5 10/29/2009 5:21:35 PM
  • CHNAME - description CHCHNAME001 'CHRONC.IN - IPEC, "New" COMIDA2-Based Food Model'
  • EVACST - daily cost CHEVACST001 46.7
  • RELCST - daily cost due to intermediate CHRELCST001 46.7
  • DUR_INTPHAS, intermediate-phase period DUR_INTPHAS 0.0
  • TMPACT - long term dose period CHTMPACT001 1.58E8
  • DSCRTI - dose criterion for phase CHDSCRTI001 1.0E5
  • DSCRLT - dose criterion for habitation CHDSCRLT001 0.04
  • EXPTIM - long term exposure period CHEXPTIM001 9.45E8
  • CRTOCR - critical organ CHCRTOCR001 L-EDEWBODY
  • LVLDEC - number of decontamination levels CHLVLDEC001 2
  • TIMDEC - time for each level CHTIMDEC001 5.184E6 CHTIMDEC002 1.0368E7
  • DSRFCT - effectiveness of decontamination CHDSRFCT001 3.

CHDSRFCT002 15.

  • CDFRM - farmland decontamination cost CHCDFRM0001 972.

CHCDFRM0002 2160.

  • CDNFRM - nonfarmland decontamination cost CHCDNFRM001 5184.

CHCDNFRM002 13824.

NIA-088

  • FRFDL - fraction farmland cost due labor CHFRFDL0001.3 CHFRFDL0002.35
  • FRNFDL - fraction nonfarmland cost due labor CHFRNFDL001.7 CHFRNFDL002.5
  • TFWKF - fraction time farmland worker CHTFWKF0001.10 CHTFWKF0002.33
  • TFWKNF - fraction time nonfarmland worker CHTFWKNF001.33 CHTFWKNF002.33
  • DLBCST - labor cost decontamination worker CHDLBCST001 60480.
  • DPRATE - depreciation rate applies to improvements CHDPRATE001.20
  • DSRATE - rate of return CHDSRATE001.12
  • POPCST - Per capita removal cost CHPOPCST001 8640.
  • NGWTRM - number weathering terms CHNGWTRM001 2
  • GWCOEF - groundshine coefficient CHGWCOEF001 0.5 CHGWCOEF002 0.5
  • TGWHLF - groundshine half lives CHTGWHLF001 1.6E7 CHTGWHLF002 2.8E9
  • NRWTRM - number resuspension terms CHNRWTRM001 3
  • RWCOEF - resuspension coefficient CHRWCOEF001 1.0E-5 CHRWCOEF002 1.0E-7 CHRWCOEF003 1.0E-9
  • TRWHLF - resuspension half lives NIA-088

CHTRWHLF001 1.6E7 CHTRWHLF002 1.6E8 CHTRWHLF003 1.6E9

  • VALWF - value of farm wealth CHVALWF0001 50071.
  • FRFIM - fraction of farm wealth due improvements CHFRFIM0001 0.25
  • VALWNF - value of nonfarm wealth CHVALWNF001 163631.
  • FRNFIM - fraction nonfarm wealth due improvements CHFRNFIM001 0.8
  • FDPATH, value = OLD, NEW or OFF to use models MACCS food, Comida2 or no food model respectively CHFDPATH001 NEW
  • COMIDA2_INP - use for premade comida2 BIN_FILE001

'f:\\NBixler\\WinMACCS Projects\\IndianPointPalla\\Data\\SAMP_A.BIN'

  • DOSEMILK DOSEMILK001 0.025 DOSEMILK002 0.075
  • DOSEOTHR DOSEOTHR001 0.025 DOSEOTHR002 0.075
  • DOSELONG DOSELONG001 0.005 DOSELONG002 0.015
  • NUMWPI - size of array NAMWPI CHNUMWPI001 4
  • popflg=FILE,NAMWPI, WSHFRI, WSHRTA, WINGF - water ingestion data CHWTRISO001 Sr-89 0.01 0.004 0.

CHWTRISO002 Sr-90 0.01 0.004 0.

CHWTRISO003 Cs-134 0.005 0.001 0.

CHWTRISO004 Cs-137 0.005 0.001 0.

  • KSWTCH - chronc output diagnostic switch CHKSWTCH001 0
  • FRACLD_FILE - popflg=FILE, dummy variable CHFRACLD001 1.0 NIA-088
  • FRCFRM_FILE - popflg = FILE, dummy variable CHFRCFRM001 1.0
  • FRMPRD_FILE - popflg=FILE, dummy variable CHFRMPRD001 0.0
  • DPFRCT_FILE - popflg=FILE, dummy variable CHDPFRCT001 0.0
  • LPROTIN - Inhalation protection factor used in CHRONC CHLPROTIN01 0.41
  • LBRRATE - Breathing rate used in CHRONC CHLBRRATE01 2.66E-04
  • LGSHFAC - groundshine shielding factor used in CHRONC CHLGSHFAC01 0.4
  • NXUM9=0 TYPE9NUMBER 0
  • NXUM9, number of type9 results TYPE9NUMBER 1
  • ORGNAM7, IX1DS9, IX2DS9, CCDF9 - Population Dose TYPE9OUT001 L-EDEWBODY 1 15 NONE
  • NXUM10=0 TYP10NUMBER 0
  • NXUM10, number of type10 results TYP10NUMBER 1
  • I1DS10, I2DS10, CCDF10 - Economic Cost TYP10OUT001 1 15 NONE
  • FLAG11 - Action Distance TYP11FLAG11.FALSE. NONE
  • NUM12=0 TYP12NUMBER 0
  • NUM13=0 TYP13NUMBER 0 NIA-088