ML11216A137

From kanterella
Jump to navigation Jump to search

Yankee Atomic Electric Company Adoption of NAC-MPC System, Amendment 5 Certificate of Compliance and Canister Registration
ML11216A137
Person / Time
Site: Yankee Rowe, Maine Yankee, 07201025
(DPR-003)
Issue date: 07/28/2011
From: Recasha Mitchell
Yankee Atomic Electric Co
To:
Document Control Desk, NRC/FSME, Office of Nuclear Material Safety and Safeguards
References
BYR 2011-018, TAC L23466, TAC L24421
Download: ML11216A137 (3)


Text

YANKEE ATOMIC ELECTRIC COMPANY Telephone (413) 424-5261 CeANKEE 49 Yankee Road, Rowe, Massachusetts 01367 July 28, 2011 BYR 2011-018 UNITED STATES NUCLEAR REGULATORY COMMISSION Attention: Document Control Desk Washington, DC 20555

References:

Subject:

(a)

License No. DPR-3 (Docket Nos.50-029; 72-30; 72-1025)

(b)

NAC-MPC Final Safety Analysis Report, Amendment No. 1, dated February 2002.

(c)

Certificate of Compliance Number 72-1025 for the NAC-MPC System, Amendment No. 1, U. S. Nuclear Regulatory Commission, dated January 23, 2002 (effective November 13, 2001).

(d)

USNRC letter to Yankee Atomic Electric Company, Exemption from 10 CFR 72.212 and 72.214, Docket 72.31 to support the Fuel Loading Campaign at Yankee Nuclear Power Station (YNPS)

(TAC No. L23466) July 30, 2002 (NYR 2002-054).

(e)

USNRC letter to Yankee Atomic Electric Company, Exemption from 10 CFR 72.212 and 72.214 for Dry Fuel Storage Activities, November 14, 2002 (NYR 2003-002).

(f)

Certificate of Compliance Number 72-1025 for the NAC-MPC System, Amendment No. 2, U. S. Nuclear Regulatory Commission, dated May 30, 2002.

(e)

Certificate of Compliance Number 72-1025 for the NAC-MPC System, Amendment No. 3, U. S. Nuclear Regulatory Commission, dated October 1, 2003.

(f)

Certificate of Compliance Number 72-1025 for the NAC-MPCO System, Amendment No. 4, U.S. Nuclear Regulatory Commission, dated October 27, 2004.

(h)

Certificate of Compliance Number 72-1025 for the NAC-MPC System, Amendment No. 5, U.S. Nuclear Regulatory Commission, dated July 24, 2007.

(i)

NAC-MPC Final Safety Analysis Report, Revision 7, Amendment 5, dated January 2008.

(j)

USNRC letter to Yankee Atomic Electric Company, Exemption froml0 CFR 72.212 and 72.214 (TAC L24421) dated July 15, 2010 (NYR 2010-007).

Yankee Atomic Electric Company Adoption of NAC-MPC System, Amendment 5 Certificate of Compliance and Canister Registration T:S

-E*ac

The purpose of this letter is to notify USNRC that all 15 NAC-MPC canisters storing spent nuclear fuel at the Yankee Atomic Electric Company site in Rowe Massachusetts will now be registered to NAC-MPC System Amendment 5.

Yankee Atomic loaded all spent nuclear fuel associated with plant operation into 15 NAC-MPCO canisters under Amendment 1 and 2 including Exemptions of NAC-MPC8 Certificate of Compliance No. 72-1025, references (c, d, e and f). Subsequently, Yankee Atomic registered those 15 canisters with the USNRC to NAC-MPCO through the 15 letters listed in Attachment A. Yankee Atomic requested an exemption from two Technical Specification requirements contained in NAC-MPC Amendment 5 Certificate of Compliance. That request was granted in reference (j).

In accordance with the regulatory guidance provided under 10 CFR 72.212(b)(4), Yankee Atomic Electric Company hereby provides notification that the 15 canisters previously registered to NAC-MPC Amendment 1 and 2 including Exemptions of NAC-MPC Certificate of Compliance No. 72-1025, references (c, d, e and f) will now be registered to the NAC-MPC System, Amendment 5 (reference (h)). Concurrent with this change, the current revision of the Final Safety Analysis Report for the NAC-MPC System will become Revision 7 (reference (i)).

If you have any questions or require additional information concerning this notification, please contact me at (413) 424-5261, extension 303 or bmitchell@3yankees.com.

Sincere<ly/

Robert Mitchell ISFSI Manager C:

W. Norton, Yankee Atomic Electric Company J. Fay, Yankee Atomic Electric Company John Goshen, Project Manager, USNRC W. Dean, Administrator Region I, USNRC J. Joustra, DNMS Branch Chief, Region I, USNRC Mark Roberts, Region I, USNRC

Attachment A - Yankee-Rowe ISFSI Cask Registration Information Docket Numbers: 50-029 and 72-30 CoC No. 1025 (expiration date: 04/10/2020)

Correspondence TSC No.

VCC No.

In-Service Amendment Amendment Notes Date Initially Reconciled (BYR YEAR-xx)

(MPC-TSC-455-xx)

(YR-VCC-xx)

Loaded to:

(Initial Registration)

(mo/day/y)

Under (No. x)

(No. x) 2002-31 01 01 06/26/2002 1

5 3

2002-41 02 02 07/18/2002 1

3 2002-42 03 03 07/27/2002 1

3 2002-45 04 04 08/19/2002 1

35 2002-46 05 05 08/29/2002 1

3 2002-51 06 06 09/12/2002 2

53 2002-62 07 07 11/26/2002 1

3 2002-64 08 08 12/11/2002 1

3 2002-69 09 09 12/19/2002 1

3 2003-02 10 10 01/09/2003 2

53 2003-05 11 13 01/29/2003 2

53 2003-15 12 12 02/08/2003 2

53 2003-17 15 15 02/28/2003 1

3 2003-19 13 16 03/12/2003 2

1,3 2003-40 14 14 05/31/2003 2

1,3 2003-42 16 11 06/21/2003 N/A N/A 2

Notes 1.

NAC-MPC CoC Amendment 1 and 2 including Exemptions 2A and 2B provided the licensing basis for design, fabrication, loading, and initial storage of the NAC-MPC System at Yankee-Rowe.

2.

Contains Greater Than Class C (GTCC) Waste. This TSC is not licensed under I OCFR72.

3.

The Yankee NAC-MPC Canisters were reconciled to NAC-MPC Certificate of Compliance 1025, Amendment 5 and NAC-MPC-FSAR Revision 7.